Wall Boilers
CHAFFOTEAUX Gas Boiler Chaffoteaux Urbia Green Ebus2 30 Eu Methane Condensing Complete Kit For Smoke Exhaust -New Erp
Overview CHAFFOTEAUX URBIA GREEN Ebus2 30 EU CONDENSING BOILER Cod. 3310408 COMPLETE WITH FUME EXHAUST KIT - NEW ErP 2015: Wall-mounted condensing boilers with 4 liter mini-accumulator. Technical specifications Product code: 3310408 Energy label specifications according to the European ErP directive Class A heating energy efficiency Sanitary energy efficiency Class A Withdrawal profiles: XL Characteristics of heating/sanitary exercises: Rated heat output max/min (Hi) Qn:ÿ28/3,0ÿkW Useful heating power80§ C/ 60§ C max/minÿ27.4/2.9ÿkW Useful heating power50§ C/ 30§ C max/minÿ29,7/3,1ÿkW Sanitary nominal thermal power max/min (60/80§C) PCI:ÿ30/ 6,5ÿkW Efficiency at nominal heat input:ÿ97.7% Efficiency 30% of nominal heat input:ÿ108.8% Energy efficiency stars: (dir 92/42/CEE) **** Capacity of the expansion vessel: 8 lt Maximum system water capacity: 100/300 litres Sanitary comfort stars(EN13203): *** Port. specific in healthcare (10 min. with T= 30øC): 14.9 l/min Hot water flow rate at T 25§ C: 16.8 l/min Degrees of protection for the electrical system:ÿIPX5D Nox class: 5 Dimensions hxwxd: mmÿ745 x 440 x 445ÿ; 45kg METHANE power supply or Features list URBIA GREEN Ebus2 EU Urbia Green is the ideal solution for all homes where the best performance is required. It is a concentration of advantages in terms of sanitary comfort with reduced dimensions and consumption. Thanks to condensing technology and integration with solar systems, it maximizes energy savings and the 4-litre sanitary reserve satisfies the needs of the most demanding users. Sanitary comfort Mini-accumulintegrated in 316L stainless steel of 4 liters. Domestic hot water performance ***, maximum level unexpected by the EN 13203 standard. Flow rate from 14.6 to 19.3 l/min with T = 25§C. DHW production controlled by a modulating turbine to respond to needs without waiting times and at a constant temperature, even when extractions are very low. DHW programmer to control the tank heating time slots Eco-Delta System: DHW load system with 4 liter reserve to further improve the comfort of DHW production and new ecological functions which allow you to save energy in DHW mode. Heating comfort Efficiencyfinal 108% with energy savingsfinal 35%. 4-star combustion efficiency according to the EN 92/42 standard. SRA function, automatic boiler regulation system according to heating requirements. Modulation wide range, from 10% to 100% of the maximum power. Reduced polluting emissions, NOx class 5. Pressure sensor of the heating circuit with visualization on LCD display. High efficiency circulator with continuous modulation to improve acoustic comfort and reduce energy consumption. Differentiated climatic thermoregulation of 2 circuits, according to the room and/or outside temperature. Arrangement for integration into a heating system via the newÿEbus2 communication protocolÿ(boilers, solar, system management modules, modulating thermoregulation accessories). Multifunction LCD display with display: history, self-diagnosis, operating temperature. Filling taps integrated in the boiler. Convenience of installation use Compatible with Expert Control: intuitive system manager for the management of 3 circuits, according to the room and/or outside temperature for greater comfort and greater energy savings. New intuitive electrical connections. Easier start-up: automatic purge function and directly accessible combustion adjustment. Save energy and respect the environment Final 25% energy savings in combination with Expert Control and the SRA function. Final 35% energy savings combine and Expert Control, the SRA function, the external probe and the radiant floor. 40% reduction in CO2 emissions**. ERP extension From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy intensive sectors: construction For placing on the European market, the directive on ÿeco-designÿ(ErP notcome®ÿEnergy Related Productsÿ¯) imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres As in the household appliances sector, the energy labelingÿof products, with a capacity of less than 70 kW, will give consumers simple, recognizable information which allows them to make comparisonsÿon the performance and energy consumption of the product they wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. The information indicated on the energy labelÿwill allow professionals to recommend the right productÿÿindividuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015, the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. The company that supplies the product on the market is required to equip its system devices with the following documentation: product energy label;ÿ product data sheet;ÿ system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices;ÿ technical data sheet of the system with the parts relating to the products and the system already completed. First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device/system to the public. Therefore, even professionals such as plumbers, installers, designers can fall into this category. All bound to ensure that: all appliances and/systems having their respective labels and making sure they are clearly visible;ÿ all appliances and/systems must always be accompanied by the obligatory technical data sheets;ÿ every type of advertising material, technical promotional material which shows energy data and price indications, contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and the production of hot water will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP): The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL There are different labels depending on the type of appliance. Those with efficiency classes A, A+ and A++ certify products with the highest performance. Furthermore, two different classifications are foreseen for domestic heating and for hot water production services, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the end customer can make his choice in the most aware way possible. SYSTEM LABEL In addition to the product label, the system label is also providedÿin cases where a series of appliances combined with each other is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label so as to inform the end user in the best possible way. Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.260,00
CHAFFOTEAUX Gas Boiler Chaffoteaux Urbia Green Link 35 Eu Integrated Wi-Fi Complete With Fume Exhaust Kit - New Erp
Technical features Product code: 3310502 Energy label specifications according to the European ErP directive Class A heating energy efficiency Sanitary energy efficiency Class A Withdrawal profile: XL Characteristics of heating/DHW operation: Nominal heat output max/min heating (Hi) 31/3.5 Useful heating power 80º C/ 60º C max/min 30.3/3.4 kW Efficiency at 30% of nominal power (47 Hi return) 97.8% Maximum heating pressure/safety valve setting 3/3.0 bar Capacity of the expansion tank 8 l Performance Stars **** Sanitary max/min rated thermal power (60/80ºC) PCI 34.5/ 7 kW Sanitary specific flow rate in compliance with EN 625 at Δt 30ºC 16,5 l/m Hot water flow rate at ∆T 25º C l/m 19.3 NOx class 5 Electrical protection degree IP X5D Dimensions: HxWxD 745 x 440 x 375; 46 kgs General characteristics URBIA GREEN LINK EU Reliable, designed to guarantee the best performance with minimum consumption and easy to manage, even remotely with your smartphone: Urbia Green Link by Chaffoteaux is the latest novelty in the field of efficient heating. Not a simple condensing boiler but a real advanced package that combines the efficiency of the new Urbia Green EU with the connectivity kit that allows the control and management of the entire system. A solution that reduces consumption by up to 40% * and obtains the advantageous tax deductions of 65% , envisaged for the purchase and installation costs of home automation systems and therefore concerning the cost of the boiler but also that of accessories and labour. In this way, just over two years are enough to recover the investment linked to the new heating system. The brain of the Chaffoteaux system is represented by the Expert Control Link chronothermostat, powered directly by the boiler and connectable to the Wi-Fi network to activate the assistance and remote control functions. It is thus possible to manage the switching on and off and the regulation of the main functions with the dedicated Chaffolink App but also to activate a remote assistance service for scheduled maintenance, remote repairs and real-time notification of any problems. In the event of a malfunction, the technician who will work on the boiler will always know the real problem in advance and the time needed to solve it, thus avoiding unnecessary site visits. The monitoring of daily, weekly and monthly consumption - from Expert Control or directly from the App - also allows you to check how much energy is used for heating and how much for domestic hot water, thus optimizing boiler management. Among the pluses of Chaffoteaux technology: the 4-litre micro-accumulator , which makes hot water immediately available, a constant report of energy consumption and the SRA function for automatic regulation of boiler parameters based on environmental conditions. Chaffoteaux Urbia Green Link is available in versions with 25 and 35 kW condensing boiler. > HEALTH COMFORT Integrated mini-accumulator in 316L stainless steel of 4 liters. Domestic hot water performance ***, maximum level foreseen by the EN 13203 standard. Flow rate from 14.6 to 19.3 l/min with ΔT = 25ºC. DHW production controlled by a modulating turbine to respond to needs without waiting times and at a constant temperature, even when extractions are very limited. DHW programmer to control the tank heating time slots Eco-Delta System: DHW filling system with 4-litre reserve to further improve the comfort of DHW production and new ecological functions which allow energy savings in DHW mode. > MAXIMUM COMFORT IN HEATING Through the free APP and the connectivity service you can constantly monitor the room temperature and manage the boiler parameters. Efficiency up to 108% with energy savings up to 35%. 4-star combustion efficiency according to EN 92/42 standard. Wide modulation range, from 10% to 100% of the maximum power. Reduced polluting emissions, NOx class 5. Heating circuit pressure sensor with visualization on LCD display. SRA function, automatic boiler regulation system according to heating requirements. Differentiated climatic thermoregulation of 2 circuits, according to the ambient and/or external temperature. Arrangement for integration into a heating system via the new Ebus 2 communication protocol (boilers, solar, system management modules and modulating thermoregulation accessories). Multifunction LCD display with display: history, self-diagnosis, operating temperature. High efficiency circulator with continuous modulation to improve acoustic comfort and reduce energy consumption. > COMFORT OF USE AND INSTALLATION Standard Expert Control : intuitive system manager for the management of 3 circuits, according to the room and/or outside temperature for greater comfort and greater energy savings. New intuitive electrical connections. Easier starting: automatic purge function and directly accessible combustion regulation. > CONSCIOUS CONSUMPTION, ENERGY SAVING AND RESPECT FOR THE ENVIRONMENT Weekly, monthly and yearly analysis on your smartphone . Up to 25% energy savings in combination with Expert Control and the SRA function. Up to 35% energy savings by combining Expert Control, the SRA function, the external probe and the radiant floor. All ready for Energy Labeling What is it about? From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy-intensive sectors: construction For placing on the European market, the eco-design directive ( ErP known as « Energy Related Products ») imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres As in the household appliances sector, the energy labeling of products with a capacity of less than 70 kW will give consumers simple, recognizable information that allows for comparisons on the performance and energy consumption of the product you wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. Is it about me too? YES, it affects everyone: professionals and end users The information indicated on the energy label will allow professionals to recommend the right product and individuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015, the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. Supplier responsibility The company that supplies the product on the market is required to equip its devices or systems with the following documentation: product energy label; technical product sheet; system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices; technical data sheet of the system with the parts relating to the product or system already completed. Dealer Responsibility First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device and/or system to the public. Therefore even professionals such as plumbers, installers or planners can fall into this category. Everyone is required to ensure that: all appliances and/or systems have their respective labels and make sure that they are clearly visible; all devices and/or systems are always accompanied by the mandatory technical data sheets; any type of advertising, promotional or technical material showing energy data or price indications contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and hot water production will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP) : The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL Depending on the type of device, there are different labels. Those with efficiency classes A, A+ and A++ certify the products with the highest performance. Furthermore, two different classifications are envisaged for domestic heating and for the hot water production service, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the final customer can make his choice in the most informed way possible. SYSTEM LABEL In addition to the product label, the system label is also provided if a series of matched appliances is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label in order to inform the end user in the best possible way. Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.273,00
CHAFFOTEAUX Gas Boiler Chaffoteaux Inoa Green Ebus2 29 Eu LPG Condensing Complete With Smoke Kit - New Erp
CHAFFOTEAUX INOA GREEN Ebus2 29 EU CONDENSING BOILER Product code: 3310478 Energy label specifications according to the European ErP directive Class A heating energy efficiency Sanitary energy efficiency Class A Withdrawal profile: XL Characteristics of heating/DHW operation: Nominal heat input in heating/DHW max/min (Hi): 29/6 kW Max/min heating thermal power (80°C-60°C): 28.4/5.8 kW DHW max/min thermal power: 28.4/5.8 kW Efficiency at nominal heat input: 97.7% Efficiency at 30% of the nominal heat input: 108% Energy efficiency stars: (dir 92/42/EEC) **** Expansion vessel capacity: 8 l Sanitary comfort stars (EN13203): ** Port. specific in healthcare (10 min. with ΔT= 30°C): 13.2 l/min Hot water flow rate at ∆T 25º C: 16.3 l/min Electrical system protection degree: IPX5D Extremely compact dimensions hxwxd: mm 745x400x315 ; 27kg LPG power supply INOA GREEN Ebus2 EU The new compact condensing boiler with aluminum alloy condensing exchanger and with all the necessary requirements to achieve the required standards in terms of energy saving. Operation only methane. Sanitary comfort Sanitary heat exchanger in stainless steel. Domestic water performance: stars **. Flow rate 13.1 litres/minute with ΔT = 25ºC. (24kW) Heating comfort Efficiency up to 108% with energy savings up to 35%. 4-star combustion efficiency in compliance with the EN92/42 standard. Modulation range from 25% to 100% of maximum power. Condensing exchanger in aluminum alloy. Reduced polluting emissions, NOx class 5. High efficiency circulator with continuous modulation to improve acoustic comfort and reduce energy consumption. Arrangement for integration into a heating system via Ebus 2 communication protocol (boilers, solar, system management modules and modulating thermoregulation accessories). Possibility of managing single-temperature and multi-temperature zones only via Expert Control. Self-diagnosis system by code. LCD display. Comfort of use and installation Possibility of connection with external probe. Compatible with Expert Control, modulating accessories and on/ff. Easier starting: automatic purge function and directly accessible combustion regulation. Energy saving and respect for the environment Up to 20% energy savings in combination with chronothermostat and external probe. 40% reduction in CO 2 emissions **. Product Warranty All products for sale on our site are new and packed. The warranty on this item is 2
€776,00
Ferroli Ferroli Bluehelix K 50 25 Kw LPG Condensing Gas Boiler Complete With Fume Exhaust Kit - New Erp
FERROLI BLUEHELIX K 50 25 Kw CONDENSING BOILER COMPLETE WITH FUME EXHAUST KIT - NEW ErP Characteristics: Seasonal space heating energy efficiency class A Water heating energy efficiency class A Declared load profile XL Heat Capacity (PCI) Min / Max Heating: 5.8 / 25.0 Thermal power 80°C-60°C: 5.7 / 24.5 Useful thermal efficiency 80°C-60°C Pmax % / Pmin %: 98.0 / 97.8 Emission class Nox class 5 Boiler capacity 50 litres Domestic hot water production Δt 30°C l/10 min 175 Sanitary Manufacturing (EN 13203) ★★★ Heating working pressure Max bar 3 DHW working pressure Max bar 9 Empty weight kg 50 Dimensions HxWxD: 800 x 600 x 420 Power supply: METHANE Certified operation also with LPG using a special kit to be requested from the Authorized Assistance Centre CHARACTERISTICS Boiler body with the new patented primary exchanger in thick AISI 316 TI stainless steel Production of domestic hot water with 50-litre stainless steel domestic hot water storage tank Total premix burner in stainless steel Electronic flame modulation both in heating and DHW Digital control panel Can be combined with the modulating remote timer control Low consumption modulating heating pump (Erp Ready - Class A) Refined design and compact size Casing painted in white by anaphoresis with epoxy powders 3-star certified comfort in sanitary manufacturing according to EN 13203 Sliding temperature operation via optional external probe Digital flame control with three re-ignition attempts in case of operation due to lack of flame detection (methane model) Arrangement for recirculation attachments Standard by-pass Place of installation: also for outdoors in a partially protected place up to - 5 ° C as standard TANGIBLE FACTS max consumption standard non-modulating circulator: 0.085 kW max consumption new high efficiency circulator: 0.04 kW Degree days 2500 (average climate zone E) Energy cost: €0.19/kWh * Hypothetical annual expenditure at max standard circulator speed: €40.375 Hypothetical annual expenditure at max speed of high efficiency circulator: €11.4 Therefore, with the replacement of standard boilers with Bluehelix K 50, in line with the new ERP regulations, electricity savings of around 30% can be estimated. In reality, the savings will be even greater, since these are modulating circulators, which at minimum power can reach consumption of up to just 3 W. The low-consumption circulator installed in the Bluehelix K 50 has a variable flow rate, with ΔT control. The advantages o ered are many, including: System start-up from cold: faster start-up with full control of the thermal load on the components Long-lasting maintenance of the temperature equilibrium conditions, once the set point has been reached Better operation in limit conditions (e.g. at minimum power), reduction of on-oFF states Reactivity to variations in the thermal load, an appreciable quality in multi-zone systems ..ROBUST Others are the merits attributable to the circulator chosen for Bluehelix K 50: The PWM signal (pulse width modulation) to the circulator allows extremely rapid intervention times to complete an advanced and complete electronic platform. This results in a drastic reduction of the ON-OFF events of the burner and the circulator. Electronic control of the drive torque at start up with consequent reduction of the risk of blocking. The routine anti-seize cycle is in any case carried out every 24 hours of inactivity. Self-protection function in case of overheating Less noise All this translates into greater longevity not only of the circulator, but also of the components subject to wear and tear from frequent on-off cycles. COMFORT AND SAFETY The designers have thought of a series of functions capable of guaranteeing the quality of the domestic water, the best delivery of power to the heating system combined with a longer life for the appliance. SLIDING TEMPERATURE OPERATION With the installation of the “external probe” kit it is possible to operate the boiler in sliding temperature. This means that without using the system temperature adjustment keys, the boiler will self-regulate according to the variations in external temperatures. All this translates into energy savings while ensuring maximum comfort for the user. ANTI-LEGIONELLA FUNCTION In order to keep the storage cylinder in suitable hygienic-sanitary conditions, the product electronics are able to keep it at a temperature of 65°C at programmable time intervals from one to seven days. ANTI-BLOCK FUNCTION In order to avoid blockage and consequent damage to the heating circulator and the three-way diverter valve, after a set period of inactivity, the boiler electronics activate operation for a few seconds. ANTIFREEZE FUNCTION In the event that the temperature in the boiler drops to 5°C, the burner automatically turns on and the circulator is activated in order to protect the appliance from damage caused by frost. This function is active with the boiler powered by the gas circuit and under electrical voltage. ECONOMY/COMFORT FUNCTION By activating the appropriate key, heating/temperature maintenance can be excluded by the user (Economy). This makes it possible to reduce fuel consumption during periods of non-use of domestic water Product Guarantee All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.394,00
CHAFFOTEAUX Gas Boiler Chaffoteaux Urbia Green Ebus2 35 Eu LPG Condensing Complete Kit For Smoke Exhaust -New Erp
Overview CHAFFOTEAUX URBIA GREEN Ebus2 35 EU CONDENSING BOILER Cod. 3310409 COMPLETE WITH FUME EXHAUST KIT -NEW ErP 2015: Wall mounted condensing boilers with 4 liter mini-accumulator. Technical specifications Product code: 3310409 Energy label specifications according to the European ErP directive Class A heating energy efficiency Sanitary energy efficiency Class A Withdrawal profiles: XL Characteristics of heating/sanitary exercises: Nominal heat output max/min (Hi) Qn:ÿ31/3,5ÿkW Useful heating power80§ C/ 60§ C max/minÿ30.3/3.4ÿkW Useful heating power50§ C/ 30§ C max/minÿ33/3,6ÿkW Sanitary nominal thermal power max/min (60/80§C) PCI:ÿ34.5/ 7ÿkW Efficiency at nominal heat input:ÿ97.7% Efficiency 30% of nominal heat input:ÿ108.7% Energy efficiency stars: (dir 92/42/CEE) **** Capacity of the expansion vessel: 8 lt Maximum system water capacity: 100/300 litres Sanitary comfort stars(EN13203): *** Port. specific in healthcare (10 min. with T= 30øC): 16.5 l/min Hot water flow rate at T 25§ C: 19.3 l/min Degrees of protection for the electrical system:ÿIPX5D Nox class: 5 Dimensions hxwxd: mmÿ745 x 440 x 445ÿ; 46kg LPG fuel supply or Features list URBIA GREEN Ebus2 EU Urbia Green is the ideal solution for all homes where the best performance is required. It is a concentration of advantages in terms of sanitary comfort with reduced dimensions and consumption. Thanks to condensing technology and integration with solar systems, it maximizes energy savings and the 4-litre sanitary reserve satisfies the needs of the most demanding users. Sanitary comfort Mini-accumulintegrated in 316L stainless steel of 4 liters. Domestic hot water performance ***, maximum level not foreseen by the EN 13203 standard. Flow rate from 14.6 to 19.3 l/min with T = 25§C. DHW production controlled by a modulating turbine to respond to needs without waiting times and at a constant temperature, even when extractions are very low. DHW programmer to control the tank heating time slots Eco-Delta System: DHW load system with 4 liter reserve to further improve the comfort of DHW production and new ecological functions which allow you to save energy in DHW mode. Heating comfort Efficiencyfinal 108% with energy savingsfinal 35%. 4-star combustion efficiency according to the EN 92/42 standard. SRA function, automatic boiler regulation system according to heating requirements. Modulation wide range, from 10% to 100% of the maximum power. Reduced polluting emissions, NOx class 5. Pressure sensor of the heating circuit with visualization on LCD display. High efficiency circulator with continuous modulation to improve acoustic comfort and reduce energy consumption. Differentiated climatic thermoregulation of 2 circuits, according to the room and/or outside temperature. Arrangement for integration into a heating system via the newÿEbus2 communication protocolÿ(boilers, solar, system management modules, modulating thermoregulation accessories). Multifunction LCD display with display: history, self-diagnosis, operating temperature. Filling taps integrated in the boiler. Convenience of installation use Compatible with Expert Control: intuitive system manager for the management of 3 circuits, according to the room and/or outside temperature for greater comfort and greater energy savings. New intuitive electrical connections. Easier start-up: automatic purge function and directly accessible combustion adjustment. Save energy and respect the environment Final 25% energy savings in combination with Expert Control and the SRA function. Final 35% energy savings combine and Expert Control, the SRA function, the external probe and the radiant floor. 40% reduction in CO2 emissions**. ERP extension From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy intensive sectors: construction For placing on the European market, the directive on ÿeco-designÿ(ErP notcome®ÿEnergy Related Productsÿ¯) imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres As in the household appliances sector, the energy labelingÿof products, with a capacity of less than 70 kW, will give consumers simple, recognizable information which allows them to make comparisonsÿon the performance and energy consumption of the product they wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. The information indicated on the energy labelÿwill allow professionals to recommend the right productÿÿindividuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015, the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. The company that supplies the product on the market is required to equip its system devices with the following documentation: product energy label;ÿ product data sheet;ÿ system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices;ÿ technical data sheet of the system with the parts relating to the products and the system already completed. First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device/system to the public. Therefore, even professionals such as plumbers, installers, designers can fall into this category. All bound to ensure that: all appliances and/systems having their respective labels and making sure they are clearly visible;ÿ all appliances and/systems must always be accompanied by the obligatory technical data sheets;ÿ every type of advertising material, technical promotional material which shows energy data and price indications, contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and the production of hot water will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP): The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL There are different labels depending on the type of appliance. Those with efficiency classes A, A+ and A++ certify products with the highest performance. Furthermore, two different classifications are foreseen for domestic heating and for hot water production services, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the end customer can make his choice in the most aware way possible. SYSTEM LABEL In addition to the product label, the system label is also providedÿin cases where a series of appliances combined with each other is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label so as to inform the end user in the best possible way. Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.243,00
Ferroli Ferroli Bluehelix Tech 35c Methane Condensing Gas Boiler Complete With Kit For Fume Exhaust -Erp
Overview FERROLI BLUEHELIX TECH 35C CONDENSING BOILER COMPLETE WITH FUME EXHAUST KIT - NEW ErP 2015: Wall-mounted condensing, premixed, sealed chamber boilers with instantaneous domestic hot water production with double exchanger. IN THE ABSENCE OF THE PRODUCT, THE NEW MODEL BLUEHELIX RRT C 34 WILL BE SUPPLIED, which can be viewed at this link: https://www.climaconvenienza.it/it/caldaia-a-gas-ferroli-bluehelix-tech-rrt-34c-metano-o-gpl-completa-di-kit-scarico-fumi-new/ Technical specifications Energy label specifications according to the European ErP directive Class A heating energy efficiency Sanitaryware energy efficiencyprofilXXL Class A Characteristics of heating/sanitary exercises: Sealed chamber condensing boiler Thermal input (PCI)ÿMax Heating: 32 kW Thermal capacity (PCI)ÿMax DHW: 34.8 kW Heating power 80øC-60øCÿMax Heating:ÿ31.4 kW Thermal power 80øC-60øCÿMax Sanitary:ÿ34.1 kW Thermal efficiencyÿ80øC-60øC: 98% Useful thermal efficiencyÿ50øC-30øC: 106.1% Efficiency termicuseÿCaricridott30%: 108.8% Domestic hot water productionÿt 30øC: 16.3 l/min Domestic hot water productionÿt 25øC: 19.5 l/min Energy certification (92/42 EEC): **** Degrees of protection: IPX5D Extremely compact dimensions (hxlxp): 600 x 400 x 320 mm; 31kg Power supply: METHANE Features list BLUE HELIX TECH Wall-mounted condensing boilers, premixed sealed chamber with instantaneous sanitary production New series of compact wall-mounted condensing boilers with instantaneous domestic hot water production. Designed to guarantee maximum energy efficiency in heating and in the supply of domestic hot water, thanks to the new bivalent exchanger patented in AISI 316 TI stainless steel. This new exchanger integrates the heating circuit and the production of domestic hot water in a single element, pushing the phenomenon of condensation to the maximum. Built to be installed outdoors in partially protected places and equipped with electronics capable of integrating with a solar panel system. The range: Range made up of two models, respectively 27 and 35 kW, running on methane, LPG, propane air. Strengths: Boiler body with patented high performance primary heat exchanger in AISI 316 TI stainless steel Instantaneous production of domestic hot water with a dedicated plate domestic hot water exchanger Total premix burner in stainless steel Digital control panel Electronic flame modulation in both heating and DHW Can be combined with the modulating remote timer control Large graphic multifunction display with backlighting for easy and correct setting of the parameters Standard by-passÿ Refined design compact size Casing painted white by anaphoresis with epoxy powders Advantages : ÿECOÿfunctionin sanitaryware for greaterÿsavingÿin the period of low use of hot water 3-star certified comfort in sanitary production according to EN 13203 Sliding temperature operationÿby means of an optional external probe Low-consumption modulating heating circulator (Erp Ready - Class A):ÿRegulation 622/2012 requires that all boilers placed on the market from 1 August 2015 be equipped with a low-consumption circulator, otherwise defined as class A. This is a decision that starts from consideration of the enormous energy expenditure of the pumps and circulators installed in the various applications. In practice, or by analyzing the impact of the low-consumption circulator integrated in the boiler, this reduces the total electricity consumption of the generator by 30%. Digital flame monitor with three re-ignition attempts in the event of blockage due to lack of flame detection (methane model) Predisposition for solar systems:ÿpredisposed for the production of domestic hot water combined with solar panel systems Place of installation:ÿalso for outdoorsin a partially protected place up to -5øC as standard and up to -15øC with the aid of the optional antifreeze heater kit Operation certified also with propane airÿ (50% air - 50% G31) by means of a specific transformation to be requested from the Authorized Assistance Center Appliance belonging to class 5, the most ecological required by European standards (UNI EN 297 NOX and 483) Products that fall under the tax benefits provided for by the Finance Law in force Functions: ECO-COMFORT function: In COMFORT mode, thanks to the particular system for maintaining the temperature of the heat exchanger, the delivery of domestic hot water becomes even more rapid and comfortable. In ECO mode, the production of domestic hot water takes place according to traditional standards. Sliding temperature operation:ÿWith the installation of the kit or External probe? possible to operate the boiler in sliding temperature. This means that without acting on the system temperature adjustment keys, the boiler will self-regulate according to the variations in external temperatures. All this translates into energy savings while guaranteeing maximum comfort for the user. Antifreeze function: In the event that the temperature in the boiler drops to 5°C, the burner automatically lights up and the circulator is activated in order to protect the appliance from damage caused by freezing. This function is active with the boiler powered by the gas circuit and electrical undervoltage. Sun Easy function: BLUEHELIX TECH has been designed to be easily inserted in systems made with the most recent technologies. The SUN EASY system, standard on the boiler, makes use of electronics that simplify the combination with both natural and forced circulation solar panels. By means of a post sensor on the sanitary circuit, it continuously checks the temperature of the water coming from the solar panels, foreseeing the ignition of the burner only when the latter drops to the level necessary to guarantee optimal comfort for the user. Tangible facts: Regulation 622/2012 provides that all boilers placed on the market from August 1, 2015 be equipped with a low-consumption circulator, otherwise defined as class A. This is a decision that starts from the consideration of the enormous energy expenditure of the pumps and circulators installed in the various applications. In practice, or by analyzing the impact of the low-consumption circulator integrated in the boiler, this reduces the total electricity consumption of the generator by 30%. consumption max. standard non-modulating circulator:ÿ0.085 kWÿ consumption max. new high efficiency circulator:ÿ0.04 kWÿ Degree daysÿ2500ÿ(average climate zone E)ÿ Energy cost:ÿ0.19 ??¶/kWhÿ Hypothetical annual expenditure at max standard circulator speed:ÿ40.375 ??¶ÿ Hypothetical annual expenditure max speed high efficiency circulator:ÿ11.4 ??¶ÿ Therefore, with the replacement of standard boilers with Bluehelix Pro, in line with the new ERP regulations, electricity savings of around 30% can be estimated. In reality, the savings will be even greater, since these are modulating circulators, which at minimum power can reach consumption of up to just 3 W ERP extension The new European regulations for heat generatorsÿ The 4 ErP Regulations on: ÿEcodesignÿ (minimum efficiency limits) and Energy Labeling (information energy label) are mandatory European provisions automatically in force from 26 September 2015 simultaneously in the 28 EU countries and in all EEA countries (European Economic Areas: Liechtenstein, Switzerland, Norway, Iceland). The Regulations (or EU Regulation? nr.: 811/2013, 812/2013, 813/2013 and 814/2013) are already published by the EU and are legal provisions which leave no legislative power (of modification/variation of delayed adoption) to the EU Member States, in so far as they do not require any national law of adoption, but come into force automatically or per se? throughout Europe.ÿ From 26th September 2015, boilers, heat pumps, tanks/boilers, water heating systems or non-ErP compliant systems will not be able to leave the factories and warehouses of MANUFACTURERS (nor from the warehouses of IMPORTERS from outside the EU), except for products for which it has already been carried out the placing on the market or the transfer of formal ownership (before 26 September) to the first customer/distributor of the commercial chain. The date which is the date on which the finished product was first placed on the market. In practice, by virtue of the new Regulations, manufacturers in the EU area and importers from outside the EU will be obliged to offer for sale only highly efficient products and systems, both for space heating and for the preparation of domestic hot water. Will the end customer be able to find latest generation products immediately on the market? which will be compulsorily accompanied by the ENERGY LABEL and compliant with the MINIMUM LIMITS calculated according to strict European standards which for the first time for these new products or ErP? considers all types of direct and indirect consumption of appliances, e.g. gas consumption and electricity consumption in a boiler.ÿ New ErP efficiency limits (and noise for heat pumps only) will apply to heating systems (boilers and heat pumps) up to 400 kW, to instantaneous gas and electric water heater systems up to 400 kW, to DHW tanks up to 2,000 kW lt. All new products and systems must be of very high efficiency, with the sole exception of tipB1x boilers (open chamber with natural draft) which will have a special derogation and may still be manufactured and sold exclusively to be installed in REPLACEMENTS on COLLECTIVE FLUES . Heat pumps will have to comply with new minimum limits for noise emissions, while for boilers the noise value will have to be indicated (without limit constraints). Furthermore, even the circulators mounted on board all the products must comply with new minimum efficiency standards (very high efficiency), based on the specific EU Regulations (nr. 641/2009 and nr. 622/2012). To make the most of all the possibilities offered by the energy label, will it be possible to predict and declare their use in a system right from the product conception and development stage? with other devices (e.g. regulation and control), thus proposing a globally more efficient whole, e.g. eg. through the use of renewable sources (solar thermal, geothermal aerothermal energy, biomass). Even the so-called or standard products? today the best sellers - i.e. boilers for gas heating - will undergo a forced evolution towards technology with heat recovery from fumes (condensing boiler). We remind you that condensing boilers can recover the heat from the fumes in most of the existing systems, even those with radiators, with the use of thermostatic valves now available in various models (also programmable individually on different times), due to their different conception of design incorporating substantial improvements over previous or standard boilers? such as the new highly efficient modulating circulators and the combustion control volume in the new premix burners. Subsequently, for products sold by manufacturers and importers from outside the EU after 26 September 2018, more stringent limits for NOx emissions will come into force Theÿ20/20/20 climate-energy package?ÿsets ambitious targets for the reduction of greenhouse gas emissions, energy consumption as well as the increase in the use of renewable energies, corresponding to a percentage of 20% to be reached by 2020. In this context , the regulationeuropeErP (Energy Related Products) introduces an energy classification also for hot water generators for space heating and domestic hot water purposes. This classification translates into an ÿenergy labelÿ which must necessarily accompany all the products affected by the Regulation, introduced on the market from 26 September 2015. The labeling constitutes an easy guide for the consumer, who can choose - through standardized and objective indications - the most efficient product. In this way, the choice will be the most sparing in terms of consumption for the benefit of the user, but also the most virtuous for energy balances and consequently, for the environment. The most significant parameters indicated on the label are the seasonal efficiency index in heating and efficiency in the eventual production of domestic hot water, according to a scale which in the casdel prodottsingolcaldaia ranges from A to G*. Furthermore, for combined boilers, a load profile is indicated corresponding to the domestic hot water flow rate of the appliances measured in a series of sample samples, thus guaranteeing the declared sanitary efficiency. This index is identified with a letter/?size? (S, M,¶ÝXXL). Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€895,00
IMMERGAS Immergas Nike Star 24 Kw LPG Gas Boiler With Open Chamber
IMMERGAS NIKE STAR 24 Kw LPG GAS BOILER WITH OPEN CHAMBER Technical features Product code: 3.025588 Characteristics: Class C heating energy efficiency Sanitary Energy Efficiency Class B Sanitary load profile: XL Maximum nominal heat input in DHW/heating kW (kcal/h) 25.9 (22,279) Minimum nominal heat input in DHW kW (kcal/h) 8.1 (6,968) Minimum nominal heat input in heating kW (kcal/h) 10.7 (9,212) Maximum useful heat output in DHW/heating kW (kcal/h) 23.6 (20,296) Minimum useful heat output in domestic hot water kW (kcal/h) 7.0 (6,020) Minimum useful heat output in heating kW (kcal/h) 9.5 (8,170) DHW circuit minimum dynamic pressure bar 0.3 Nominal heating expansion vessel capacity (total) liters 6.0 (4.2) Electrical protection degree IP X4D Dimensions H x W x D: 781 x 440 x 240. Power supply: LPG NIKE STAR Conventional, instantaneous wall-mounted boiler. Extremely compact, it is ideal for replacing old boilers in the presence of branched collective flues. COMPACTNESS AND VERSATILITY The extreme compactness (only 24 cm deep) allows installation even in environments with limited and limited spaces. RAPIDITY OF DOMESTIC HOT WATER DELIVERY Thanks to the bithermal type exchanger, which integrates both circuits for heating and the production of domestic water inside, hot water is almost immediate. COMBINATION WITH MINI CRD The boiler electronics allow the combination (for systems with a single zone) with Mini Digital Remote Control (MINI CRD), which integrates the remote control and climatic thermoregulation functions of the appliance. OPTIONAL CONNECTION UNIT The pipes connecting the boilers to the system are available as an optional kit (code 3.015229). IDEAL FOR CONNECTION TO EXISTING BRANCHED COLLECTIVE FLUES NIKE STAR 24 ErP complies with the thermal efficiency value (at 30% of the load) provided for by Article 4, paragraph 7 of Presidential Decree 59/09 for cases of mere replacement of the boiler, with connection with branched collective flues (ccr). Product Guarantee The warranty on this item is 24 months from the date of purchase.
€428,00
Riello Riello Family Ar 25 Kis Methane Condensing Boiler Complete With Smoke Kit -New Erp
RIELLO FAMILY AR 25 KIS METHANE CONDENSING BOILER COMPLETE WITH FUME KIT - NEW ErP Technical characteristics Product code: 20100508 Energy label specifications according to the European ErP directive Class B heating energy efficiency Sanitary energy efficiency profile XL Class A Characteristics of heating/DHW operation: Furnace thermal power (heating) min-max: 8.5÷25.0 kW Useful thermal power (sanitary) min-max: 8.5÷25.0 kW Energy efficiency (92/42/EEC) **** Useful efficiency at Pn* (50°C-30°C): 96.2% Profit return 30% (47th return): 95.3% Sealed chamber, forced draught Quantity of hot water with Δt 25°C: 14.3 l/min Minimum domestic water flow rate: 2 l/min Dimensions (hxlxp) mm 845 x 400 x 332 ; 42 kgs Electrical protection degree: IP X5D NOx class: 2 Power supply: METHANE FAMILY AR Yield **** Combined models for heating and domestic hot water production Family AR is the new generation condensing boiler specifically designed to operate with high temperatures (80°C delivery and 60°C return) and therefore in radiator systems. Family AR contains Altaresa condensing technology in the aesthetics and in the special Family functions. Family AR has an Air/Gas combustion (patented): thanks to the modulating fan, the mixture of air and gas is kept optimal and constant over the entire power range, always maintaining high efficiency. Thanks to the treated aluminum post-exchanger, very high yields up to 102.9% are obtained. The climatic regulation is managed directly by the boiler control unit, via the external probe (accessory), it allows the temperature of the heating system to be suitably adapted to the external climatic conditions. The equipment is completed by anti-freeze systems (down to -3°C), circulator anti-blocking systems, three-way valve, Wellness button and rapid button which reduces the waiting times for domestic hot water. Family AR is available with powers of 25, 29 and 35 kW. Characteristics: Technology, ease of control and management: • Memory key: activates machine intelligence. - sanitary: hot water always ready and without waste, according to the usage habits of the family. - in heating: reduction of home heating times. • Wellness key: maintains hot water delivery at the ideal temperature for the shower (40°C customizable +/- 5°C). • Touch&Go function: directly from the tap, it activates pre-heating for just one water draw. • Intelligent system filling: allows you to fill the system in complete autonomy. Air/gas combustion (patented): optimal mixture of gas and air to obtain high and constant efficiency over the entire power range with efficiency up to 102.9%. Condensing exchanger located downstream of the fan for further recovery of the heat contained in the exhaust fumes. Advantages for installation: Efficiency ★★★★ according to Dir. 92/42/CEE. Low consumption circulator (IEE≤0.20) Climatic regulation managed directly by the boiler control unit Special Family functions: Wellness key, Memory key, Touch&Go function Intelligent system filling Assembly template, hydraulic fittings, power supply cable supplied. Product Guarantee All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.359,00
RINNAI Amami 29 Plus LPG Rinnai Condensing Gas Boiler Complete With Smoke Kit
Overview RINNAI CONDENSING BOILER AMAMI 29 PLUS LPG COMPLETE WITH FUME KIT: Combined premix gas condensing boilers. Technical specifications Model: Love me 29 PLUS Code: A245Cÿ Heating nominal heat input: 22.5 kW DHW nominal heat input: 28.9 kW Energy efficiency marking 92/42 EEC:ÿ **** Efficiency at full loadÿ(80ø/60ø):ÿ98% Return profit to partial loadÿ30%: 109.9% Sealed chamber, forced draft Nominal power modulation:ÿ(Tm/Tr=80/60øC) Heating kWÿ4.4 -22.1 Nominal power modulation:ÿ(Tm/Tr=36/30øC) Heating kW 4.9 - 24 Pollution class marking:ÿNox EN 483 5 G20 gas consumption at 1,013 mbar and 15øC:ÿ(Sanitary) mü/h 2.38 (3.06) Maximum absorbed electrical power: 75 Wÿ Electric power absorbed at partial load: 28 W Heating/sanitary water content: 3.3/0.7 l Expansion tank content: 8 lt DHW delivery (T=38øC): 10.5 l/min DHW delivery (T=25øC): 16.1 l/min Maximum working temperature: 85øC Dimensions (hxlxp) mm 650 x 500 x 395 ; 37Kg Electrical Protection Degrees:ÿIPX4D Power supply: LPG Features list CONDENSATION the environmentally friendly and energy saving technology.ÿCondensing boilers are clean and efficient: even the water vapor contained in the combustion products is used to generate heat. By making the most of the condensate, the energy to produce the desired heat is less, with the advantage of saving energy. In fact, condensing boilers reduce consumption by a final 30% and polluting emissions (NOx and CO2) by a final 70%, respecting the 'traditional' ones. LOVE ME and LOVE ME PLUS Love me Oshima a Japanese tropical island: the new collection of condensing boilersÿRinnai is inspired by her. Love me because I'm perfect. It heats your home and, while doing so, it respects the environment with the lowest polluting emissions. And let us save money, ensuring a constant return for my entire life. Love me because I am at the forefront of technology, designed to be truly capable of improving your daily comfort. Love me because I will be able to surprise you, with all the domestic hot water you need. Instant type condensing gas heat generator for heating and domestic hot water production, complete with electronic display with regulation and self-diagnosis function, which can be combined with a digital remote control. LOVE ME: A stainless steel heartÿThe heartÿ of allÿRinnai boilers, the heat exchanger, in stainless steel. This, in combination with the inverted flame ceramic burner, guarantees the highest efficiency of all the boilers on the market (109.9% according to EN 677). All Rinnai Amami shima appliances have advanced electronics and the ability to modulate from very low powers such as to guarantee a constant operating curve, avoiding overheating and cooling of the premises. The production of DHW, in all models, is abundant and immediate, to safeguard comfort and save energy. The structure of Rinnai boilers is sound-absorbing, designed to minimize the sound impact on the house: measured in decibels, the noise produced by the boiler is the same as you can hear in a library. Energy classification: 4 STARS /4 ACS Rating: 3 STARS /3 Furthermore, the 2 AMAMI PLUS models are also equipped with a chronothermostat and external climatic probe as standard. Warranty All products for sale on our site are new and packed. The guarantee on this article is 24 months from the date of purchase.
€1.904,00
VAILLANT Vaillant Ecotec Plus Condensing Boiler Vmi 306/5-5 With Kettle Complete With Fume Kit - Erp LPG
ATTENTION THE BOILER IS BORN WITH METHANE AND IS ADJUSTABLE TO LPG. FOR INFO, CONTACT THE AUTHORIZED AREA ASSISTANCE CENTER IN ADVANCE NB: In the absence of the product, the new VMI 30 model will be shipped Product name VAILLANT ecoTEC PLUS CONDENSING BOILER VMI 306/5-5 with boiler COMPLETE WITH FUME KIT - ErP LPG Technical features ErP energy class (Heating and DHW): class A Sanitary load profile - XL For heating and domestic hot water production Forced draft sealed chamber Nominal thermal power in sanitary kW 30 DHW nominal heat input kW 30.6 Performance stars (according to Dir. 92/42CEE) - **** Consumption at nominal power Natural gas m3 /h 3.2 Expansion vessel capacity 10 l Maximum water content in the system l 180 Storage tank setting temperature °C 35 - 65 Boiler nominal volume l 20 Minimum water flow l/min 1.5 Hot water withdrawal capacity (ΔT = 30K) l/10min 180 Domestic hot water comfort stars (prEN 13203) - *** Dimensions (hxpxl) mm 720x553x440; 57kg Power supply V/Hz 230/50 Total electric power W 100 Sound power dBA 50 IP degree of protection IP X4 D NOx class - 5 Version: CNG (0010019530) General characteristics Vaillant condensing boiler With the strategic plan 20/20/20, Europe has the objective of producing 20% less CO2, using 20% more renewable energy and consuming 20% less primary energy. All this by 2020. To achieve these objectives, the EU has issued the ErP Directive (energy related products) which specifies the minimum eco-design requirements for equipment that uses energy, including energy efficiency. The world of heating will also be affected by this revolutionary change. In fact, from 2015 the energy efficiency of boilers will be based on new performance indexes that will take into account seasonal performance. Among the most significant changes to the new methodology for measuring seasonal efficiency are the introduction of different nominal temperatures, operation also at partial loads and in standby mode. The new methodology will make it possible to evaluate the performance of a boiler in real conditions, based on the level of efficiency calculated over an entire year. ecoTEC PLUS with boiler Little space and a large family? ecoTEC plus with built-in wall-mounted boiler is the boiler designed to satisfy a high demand for hot water when spaces do not allow for the installation of external boilers. The VMW ecoTEC plus with actoSTOR CL 20 S integrable storage tank are available in power ratings of: 30 and 34 kW. This stratification boiler is a real hot water reserve that can be installed very easily and quickly directly between the wall and the boiler. An exceptional solution that ensures the quantity of water needed is always available and without sudden changes in temperature. The boiler system with storage tank is very simple to assemble: first install the actoSTOR CL wall-mounted storage tank and the related pipes supplied for domestic water, then hang the ecoTEC plus VMW wall-mounted boiler on the storage tank. The dimensions are very small 70cm high, 44cm wide and 55cm deep. The stratification storage tank guarantees the same performance as a storage tank with a 60-litre coil but with considerably reduced spaces. The combination with ecoTEC plus allows you to exclude the storage tank functionality by making the boiler work instantaneously; this allows a considerable saving on gas consumption. New electronics and a very high efficiency pump make ecoTEC plus the wall-mounted condensing boiler that consumes less on the European market. ecoTEC plus is compatible with all Vaillant components and accessories already on the market. The new design is simple and intuitive. Characteristics: ErP: class A Boiler with integrable storage tank Power modulation 1:8 10l expansion vessel High efficiency modulating pump (class A) Primary heat exchanger in steel High efficiency in the production of hot water up to 199 liters in the first 10' High DHW comfort Compact stratification storage **** Heating efficiency ELGA combustion system Product Guarantee All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€2.212,00
Ariston Ariston Clas Evo 24 Cf Eu Gpl Boiler - New Erp
ARISTON CLAS EVO 24 CF EU BOILER Product code: 3300730 (gpl) Energy label specifications according to the European ErP directive Class C heating energy efficiency Sanitary energy efficiency profile XL Class B Characteristics of heating/DHW operation: For heating and domestic hot water production Open chamber with natural draft Nominal heat input in heating max/min kW 25.8/11 Max/min heating thermal power (80°C-60°C) kW 23.7/9.9 Efficiency at nominal heat input % 91.9 Efficiency at 30% of nominal flow rate % 91.2 Performance stars (dir. 92/42/EEC) ★★★ Heating max/min temperature °C 35/ 85 Max/min domestic hot water temperature°C 36/60 Specific flow rate in DHW (10 min. with ∆T=30°C) litres/min 12.2 Quantity of hot water ∆T=25°C litres/min 14.2 Quantity of hot water ∆T=35°C litres/min 10.2 Supply voltage/frequency V/Hz 230/50 Total absorbed electric power W 61 Degrees of protection of the electrical system IP X4D Dimensions (H x W x D) mm 770/400/315 LPG power supply Evo class Conventional compact wall-mounted boiler with auto function The Clas Evo wall-mounted boiler is Ariston's solution for home comfort; it stands out for its innovative and captivating design and for its small size that makes it suitable for any type of furniture. It is available in the heating and domestic hot water production version in 2 powers: 24 and 28 kW (open chamber) Characteristics: Backlit multifunction LCD screen Continuous modulation high efficiency circulator Arrangement for multi-zone and multi-temperature thermoregulation Arrangement for solar system management Car function and comfort Aluminum finned primary exchanger Arrangement for integration with system configuration through the new Bus Bridgnet® communication protocol Cold water inlet and heating return filters Convenience function: The Comfort function speeds up the delivery of domestic hot water, reducing waiting times down to just 5”. This service can be customized by choosing between two modes of use: COMFORT PLUS (hot water immediately ready every time the tap is opened in just 5 seconds) COMFORT (hot water ready for 30 minutes after the last withdrawal so as not to give up savings) car function: It is truly possible to combine maximum comfort with reduced consumption, thanks to the intelligent management logic of the new boilers and the new technology that governs them. By activating the AUTO function, the Ariston boiler chooses the best operating mode based on the environmental conditions, the connected external devices and the required performance. Impossible to compare this ability to interpret and respond to external stimuli with what has been achieved so far. AUTO does not fear comparisons High efficiency circulator with continuous modulation: It allows automatic adaptation of the power based on the temperature of the system, guaranteeing boiler performance and reducing electricity consumption. Optimization of thermal efficiency. Optimization of comfort with constant temperature. Maximum silence. Product Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€606,00
Ferroli Ferroli Bluehelix Tech 25c Methane Condensing Boiler Complete With Smoke Exhaust Kit
IN THE ABSENCE OF THE PRODUCT, THE NEW MODEL BLUEHELIX RRT C 24 WILL BE SUPPLIED. IT CAN BE VIEWED AT THIS LINK: https://www.climaconviene.it/it/caldaia-a-gas-ferroli-bluehelix-tech-rrt-24c-metano-o-gpl-completa-di-kit-scarico-fumi-new/ Technical features Model : Bluehelix Tech 25C Power supply: methane Energy rating Heating energy efficiency class: A DHW energy efficiency class: A Space heating energy efficiency : ηs 94 % Thermal range Minimum : 5.8 kW Maximum heating : 25.0 kW Maximum DHW : 27.5 kW Thermal power 60°C ~ 80°C Minimum : 5.7 kW Maximum heating : 24.5 kW Maximum DHW : 27.0 kW Thermal power 30°C ~ 50°C Minimum : 6.2 kW Maximum heating : 26.5 kW Useful efficiency 60°C ~ 80°C Minimum : 97.8% Maximum : 98.0 % Useful efficiency 30°C ~ 50°C Minimum : 106.1% Maximum : 107.5% Load reduced 30% : 108.8% Domestic hot water production ∆t 25°C : 15.5 l/min ∆t 30°C : 12.9 l/min Heating operating pressure Minimum : 0.8 bar Maximum : 3 bars Dimensions and weight Dimensions (HxWxD): 600x400x320 mm Empty weight: 28.0 kg Bluehelix Tech Wall mounted condensing, instantaneous or heating only boilers Efficiency, rationality and sturdiness. Recognized The range of generators is equipped with the new AISI 316 TI stainless steel exchanger. Designed and built according to the new ErP directives for eco-compatible design and labelling, Bluehelix Tech is at the top of its category. Bluehelix Tech achieves one of the highest energy efficiency of space heating in its category: ηs 94% . Furthermore, when combined with the external probe and the Romeo remote timer control, it reaches system energy class A+. Components The exchanger Ferroli has directed its research and design towards an exchanger that is simple and robust in its structure, using first-rate materials The exchanger consists of a simple spiral, without joints or welds. The generous section of the pipes allows a free, wide passage of the system fluid. The serpentine shape contrasts the deposit of impurities. The tube bundle is unique, without further parallel circuits. Since it is not a collector type exchanger, it is impossible for air bubbles to remain in the meanders of the circuits. Furthermore, any chemical washing of the boiler will take place effectively, as there is no possibility that the descaler pump pushes through a free circuit rather than a clogged one The tube that makes up the Bluehelix Tech exchanger is made of AISI 316 Ti stainless steel. It is a so-called austenitic alloy, particularly resistant to corrosion, enriched with the addition of titanium. it is also a material that allows for the creation of an extremely smooth surface, therefore less susceptible to encrusting agents and deposits The circulator distribution in class A Regulation 622/2012 provides that all boilers placed on the market from 1 August 2015 are equipped with a low-consumption circulator, otherwise defined as "class A". It is a decision that starts from the consideration of the enormous energy expenditure of the pumps and circulators installed in the various applications. In practice, i.e. by analyzing the impact of the low-consumption circulator integrated in the boiler, it reduces up to 30% of the total electricity consumption of the generator Self-adaptive The low-consumption circulator installed in the Bluehelix Tech has a variable flow rate, with ΔT control. The advantages offered are many, including: Cold system start-up: faster start-up with full control of the thermal load on the components Long-lasting maintenance of the temperature equilibrium conditions, once the set point has been reached Better operation in limit conditions, for example at minimum power, reduction of on-off states Reactivity to variations in the thermal load, an appreciable quality in multi-zone systems Robust Others are the merits attributable to the circulator chosen for Bluehelix Tech: The PWM signal (pulse width modulation) to the circulator allows extremely rapid intervention times to complete an advanced and complete electronic platform. This results in a drastic reduction of the ON-OFF events of the burner and the circulator. Electronic control of the drive torque at start up with consequent reduction of the risk of blocking. The routine anti-seize cycle is in any case carried out every 24 hours of inactivity. Self-protection function in case of overheating. Less noise Boiler control Control panel and functions The BLUEHELIX TECH control and management electronics allow the user to customize the operation of the appliance in order to manage the environmental comfort according to one's needs. The key control panel and the simple LCD display make the programming operations for the production of hot water, both for domestic hot water and for heating, extremely easy and intuitive. The remote control ROMEO Chronocontrol The BLUEHELIX TECH control and management electronics allow the user to customize the operation of the appliance in order to manage the environmental comfort according to one's needs. The key control panel and the simple LCD display make the programming operations for the production of hot water, both for domestic hot water and for heating, extremely easy and intuitive. With ROMEO you can: Adjust the heating and DHW temperatures Know the operating status of the boiler View the temperatures inside and outside the house Restart the boiler in case of temporary lockout Program the daily or weekly environmental comfort Activate/deactivate the heating function via the telephone The ROMEO modulating function allows boiler output to be modulated as the set room temperature value is reached. This improves the quality of comfort by eliminating heat peaks with consequent energy savings Guarantee : All the products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€833,00