icon Chiller heat pumps | CaldaieMurali

Chiller heat pumps

Our chiller heat pumps represent the innovative energy solution for efficient heating and cooling of rooms. Check it out and discover the benefits today!

206 products


  • immagine-1-ferroli-pompa-di-calore-reversibile-aria-acqua-inverter-ferroli-omnia-s-3.2-12-monofase-r-32-con-comando-incluso

    Ferroli Air-Water Reversible Heat Pump Inverter Ferroli Omnia S 3.2 12 Single-Phase R-32 With Control Included

    ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS   FREE FIRST START-UP Technical features Model : OMNIA S 3.2 12 Product code : 0XHKCSWA Command included Optional accessories Unpainted built-in cabinet 016092X0 Painted built-in cabinet 016093X0 Optional accessories Unpainted built-in cabinet 016092X0 Painted built-in cabinet 016093X0 Energy efficiency Energy class in heating at 35° C: A+++ Energy class in heating at 55° C: A++ SCOP heating with water set at 35 °C : 4.81 SEER cooling with water set at 7 °C: 4.89 Performance   Heating Useful power in heating with water set at 35° C: 12.1 kW Useful power in heating with water set at 45° C: 12.3 kW Useful power in heating with water set at 55° C: 11.9 kW Absorbed power with water set at 35° C: 2.44 kW Absorbed power with water set at 45° C: 3.32 kW Absorbed power with water set at 55° C: 3.90 kW Water flow rate with water set at 35° C : 2081 l/h Water flow rate with water set at 45° C : 2116 /h Water flow rate with water set at 55° C : 1279 l/h Cooling down Useful power in cooling with water set at 7 °C: 11.5 kW Useful power in cooling with water set at 18 °C: 12.0 kW Absorbed power with water set at 7° C: 4.18 kW Absorbed power with water set at 18° C: 3.04 kW Water flow rate with water set at 7° C : 1978 l/h Water flow rate with water set at 18° C : 2064 l/h External unit technical data Compressor type : Twin Rotary DC Number of compressors : 1 Number of cooling circuits: 1 Type of fans : DC axial Number of fans : 1 Sound power level in heating : 56 ~ 65 dB(A) Sound power level in cooling : 56 ~ 65 dB(A) Liquid pipe diameter : 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Maximum piping length: 30 m Maximum pipe height difference: 20 m Indoor unit technical data Exchanger type : Brazed stainless steel plates Expansion vessel volume: 10 litres Water safety valve setting: 3 bar Minimum system water content: 40 litres System piping diameter: 1" gas F DHW piping diameter: 3/4" gas F Liquid pipe diameter : 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Electrical data Power supply (V,Hz, Ø) : 220~240/50/1 Refrigerant gas : R32 Dimensions and weight External unit dimensions (WxHxD): 1118x865x523 mm Outdoor unit weight: 96.0 Kg Internal unit dimensions (WxHxD): 422x702x320 mm 5 years without worries Ferroli OMNIA S 3.2 Reversible heat pumps for split installation with DC inverter compressor Quietness, efficiency and design OMNIA S 3.2 is the new range of split heat pumps Full Inverter R32 by Ferroli. The range includes an Outdoor Unit with the heart of the refrigerant circuit, from the compressor to the fan with the air side exchanger, which is connected to the refrigerant gas pipes towards the Indoor Unit. The Indoor Unit, on the other hand, contains the heart of the hydraulic circuit of the generator with all the main pre-installed components, such as the high-efficiency circulator and the expansion vessel, to safely allow quick and practical installation The split installation of OMNIA S 3.2 , with only the gas pipes between the outdoor and indoor unit, is synonymous with security against any freezing problem, even at the coldest temperatures (down to -25°C) and in the absence of electricity. All units meet the most extreme winter and summer air conditioning requirements, they can in fact produce hot water up to 65°C , which makes them suitable for practically all heating systems, whether radiant, fan coil or radiator, including the production of domestic hot water (DHW), via an external boiler The new conception Full Inverter by Ferroli uses DC inverter modulations on the 3 main energy-intensive components of the machine, i.e. compressor, fan and pump. This allows you to modulate the power supplied by finely tracking the thermal load and allowing the user very high efficiencies and important energy savings . Also, the concept Full Inverter by Ferroli guarantees sound levels among the lowest on the market, avoiding sudden changes in the network and guaranteeing a longer useful life for the components. Indoor and outdoor unit of OMNIA 3.2 The Outdoor Unit contains the heart of the refrigerant circuit, while the Internal Unit the heart of the hydraulic circuit. They are connected to each other by pipes R32 ecological refrigerant gas , which has allowed us to combine high efficiency with a reduced environmental impact. Thanks to his GWP of 675 , about a third of the GWP of R410a, helps reduce CO2 equivalent emissions, the main causes of global warming The heat pumps use the Outdoor Unit to extract heat from the air outside the home and convey it to the water in your system, via an exchanger in the Indoor Unit. That's exactly why they manage to get such high efficiencies , exploiting so renewable the energy already present in the air outside the home The new conception Full Inverter by Ferroli then does the rest, tracking the thermal loads precisely and without waste (modulating the compressor, pump and fan), manages to achieve even greater efficiencies, guaranteeing important savings in bills , without stress on the components and with very low sound levels OMNIA S 3.2 it can be used both as the sole generator of the system and integrated with other sources such as a Ferroli boiler The control system The user interface has been equipped with capsense technology with 2.8” graphic display, which allows the user to interact with the product easily and extremely simply Modbus protocol It can be interfaced to BMS/BACS automation and management systems Heating and cooling Full Inverter modulation finely follows the desired setpoints, with the possibility of setting heating and cooling climatic curves, further optimizing consumption for the user Domestic hot water production When the DHW temperature probe calls the machine, it automatically switches to the domestic hot water tank with dedicated DHW set point. 3-way diverter valve supplied as standard Smart Grid input from photovoltaic and grid Digital Smart Grid inputs for the management of an input from the photovoltaic system and from the electricity grid. These allow you to optimize consumption and bill costs DHW tank electrical resistance The DHW electrical integration serves as integration, anti-legionella or reserve source in the event of an anomaly Fast DHW Priority to DHW production to bring the storage tank to the set point in the shortest possible time Anti-legionella function Allows you to set anti-legionella weekly cycles Silent mode Reduces the frequency of the compressor and the speed of the fan, so as to significantly reduce noise. Programmable on time slots ON/OFF From external contact. Activation and deactivation via an external contact, for example from a zone thermostat Hot / cold From external contacts. Summer/winter switching signal from outside, for example from the zone thermostat ECO function Dedicated setpoint for " Eco " operation. Settable with daily time band Anti-freeze protection Heat pump operation with circulator ON and possible electric booster Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €4.901,00

  • immagine-1-ferroli-pompa-di-calore-reversibile-aria-acqua-inverter-ferroli-omnia-s-3.2-08-r-32-con-comando-incluso

    Ferroli Air-Water Reversible Heat Pump Inverter Ferroli Omnia S 3.2 08 R-32 With Control Included

    ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS   FREE FIRST START-UP Technical features Model : OMNIA S 3.2 08 Product code : 0XHK8SWA Command included Optional accessories Unpainted built-in cabinet 016092X0 Painted built-in cabinet 016093X0 Optional accessories Unpainted built-in cabinet 016092X0 Painted built-in cabinet 016093X0 Energy efficiency Energy class in heating at 35° C: A+++ Energy class in heating at 55° C: A++ SCOP heating with water set at 35 °C : 5.21 SEER cooling with water set at 7 °C: 5.83 Performance   Heating Useful power in heating with water set at 35° C: 8.40 kW Useful power in heating with water set at 45° C: 8.30 kW Useful power in heating with water set at 55° C: 7.50 kW Absorbed power with water set at 35° C: 1.63 kW Absorbed power with water set at 45° C: 2.16 kW Absorbed power with water set at 55° C: 2.36 kW Water flow rate with water set at 35° C : 1445 l/h Water flow rate with water set at 45° C : 1428 /h Water flow rate with water set at 55° C : 806 l/h Cooling down Useful power in cooling with water set at 7 °C: 7.45 kW Useful power in cooling with water set at 18 °C: 8.30 kW Absorbed power with water set at 7° C: 2.22 kW Absorbed power with water set at 18° C: 1.64 kW Water flow rate with water set at 7° C : 1281 l/h Water flow rate with water set at 18° C : 1428 l/h External unit technical data Compressor type : Twin Rotary DC Number of compressors : 1 Number of cooling circuits: 1 Type of fans : DC axial Number of fans : 1 Sound power level in heating : 55 ~ 61 dB(A) Sound power level in cooling : 54 ~ 61 dB(A) Liquid pipe diameter : 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Maximum piping length: 30 m Maximum pipe height difference: 20 m Indoor unit technical data Exchanger type : Brazed stainless steel plates Expansion vessel volume: 10 litres Water safety valve setting: 3 bar Minimum water content: 40 litres System piping diameter: 1" gas F DHW piping diameter: 3/4" gas F Liquid pipe diameter : 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Electrical data Power supply (V,Hz, Ø) : 220~240/50/1 Refrigerant gas : R32 Dimensions and weight External unit dimensions (WxHxD): 1118x865x523 mm Outdoor unit weight: 77.0 Kg Internal unit dimensions (WxHxD): 422x702x320 mm 5 years without worries Ferroli OMNIA S 3.2 Reversible heat pumps for split installation with DC inverter compressor Quietness, efficiency and design OMNIA S 3.2 is the new range of split heat pumps Full Inverter R32 by Ferroli. The range includes an Outdoor Unit with the heart of the refrigerant circuit, from the compressor to the fan with the air side exchanger, which is connected to the refrigerant gas pipes towards the Indoor Unit. The Indoor Unit, on the other hand, contains the heart of the hydraulic circuit of the generator with all the main pre-installed components, such as the high-efficiency circulator and the expansion vessel, to safely allow quick and practical installation The split installation of OMNIA S 3.2 , with only the gas pipes between the outdoor and indoor unit, is synonymous with security against any freezing problem, even at the coldest temperatures (down to -25°C) and in the absence of electricity. All units meet the most extreme winter and summer air conditioning requirements, they can in fact produce hot water up to 65°C , which makes them suitable for practically all heating systems, whether radiant, fan coil or radiator, including the production of domestic hot water (DHW), via an external boiler The new conception Full Inverter by Ferroli uses DC inverter modulations on the 3 main energy-intensive components of the machine, i.e. compressor, fan and pump. This allows you to modulate the power supplied by finely tracking the thermal load and allowing the user very high efficiencies and important energy savings . Also, the concept Full Inverter by Ferroli guarantees sound levels among the lowest on the market, avoiding sudden changes in the network and guaranteeing a longer useful life for the components. Indoor and outdoor unit of OMNIA 3.2 The Outdoor Unit contains the heart of the refrigerant circuit, while the Internal Unit the heart of the hydraulic circuit. They are connected to each other by pipes R32 ecological refrigerant gas , which has allowed us to combine high efficiency with a reduced environmental impact. Thanks to his GWP of 675 , about a third of the GWP of R410a, helps reduce CO2 equivalent emissions, the main causes of global warming The heat pumps use the Outdoor Unit to extract heat from the air outside the home and convey it to the water in your system, via an exchanger in the Indoor Unit. That's exactly why they manage to get such high efficiencies , exploiting so renewable the energy already present in the air outside the home The new conception Full Inverter by Ferroli then does the rest, tracking the thermal loads precisely and without waste (modulating the compressor, pump and fan), manages to achieve even greater efficiencies, guaranteeing important savings in bills , without stress on the components and with very low sound levels OMNIA S 3.2 it can be used both as the sole generator of the system and integrated with other sources such as a Ferroli boiler The control system The user interface has been equipped with capsense technology with 2.8” graphic display, which allows the user to interact with the product easily and extremely simply Modbus protocol It can be interfaced to BMS/BACS automation and management systems Heating and cooling Full Inverter modulation finely follows the desired setpoints, with the possibility of setting heating and cooling climatic curves, further optimizing consumption for the user Domestic hot water production When the DHW temperature probe calls the machine, it automatically switches to the domestic hot water tank with dedicated DHW set point. 3-way diverter valve supplied as standard Smart Grid input from photovoltaic and grid Digital Smart Grid inputs for the management of an input from the photovoltaic system and from the electricity grid. These allow you to optimize consumption and bill costs DHW tank electrical resistance The DHW electrical integration serves as integration, anti-legionella or reserve source in the event of an anomaly Fast DHW Priority to DHW production to bring the storage tank to the set point in the shortest possible time Anti-legionella function Allows you to set anti-legionella weekly cycles Silent mode Reduces the frequency of the compressor and the speed of the fan, so as to significantly reduce noise. Programmable on time slots ON/OFF From external contact. Activation and deactivation via an external contact, for example from a zone thermostat Hot / cold From external contacts. Summer/winter switching signal from outside, for example from the zone thermostat ECO function Dedicated setpoint for " Eco " operation. Settable with daily time band Anti-freeze protection Heat pump operation with circulator ON and possible electric booster Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €3.700,00

  • immagine-1-ferroli-pompa-di-calore-reversibile-aria-acqua-inverter-ferroli-omnia-s-3.2-04-r-32-con-comando-incluso

    Ferroli Air-Water Reversible Heat Pump Inverter Ferroli Omnia S 3.2 04 R-32 With Control Included

    ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS   FREE FIRST START-UP Technical features Model : OMNIA S 3.2 04 Product code : 0XHK4SWA Command included Optional accessories Unpainted built-in cabinet 016092X0 Painted built-in cabinet 016093X0 Energy efficiency Energy class in heating at 35° C: A+++ Energy class in heating at 55° C: A++ SCOP heating with water set at 35 °C : 4.85 SEER cooling with water set at 7 °C: 4.99 Performance   Heating Useful power in heating with water set at 35° C: 4.20 kW Useful power in heating with water set at 45° C: 4.30 kW Useful power in heating with water set at 55° C: 4.40 kW Absorbed power with water set at 35° C: 0.82 kW Absorbed power with water set at 45° C: 1.13 kW Absorbed power with water set at 55° C: 1.49 kW Water flow rate with water set at 35° C : 722 l/h Water flow rate with water set at 45° C : 740 l/h Water flow rate with water set at 55° C : 473 l/h Cooling down Useful power in cooling with water set at 7 °C: 4.70 kW Useful power in cooling with water set at 18 °C: 4.50 kW Absorbed power with water set at 7° C: 1.36 kW Absorbed power with water set at 18° C: 0.82 kW Water flow rate with water set at 7° C : 808 l/h Water flow rate with water set at 18° C : 774 l/h External unit technical data Compressor type : Twin Rotary DC Number of compressors : 1 Number of cooling circuits: 1 Type of fans : DC axial Number of fans : 1 Sound power level in heating : 53 ~ 60 dB(A) Sound power level in cooling : 52 ~ 60 dB(A) Liquid piping diameter : 6.35 mm (1/4") Gas pipe diameter: 15.88 (5/8") Maximum piping length: 30 m Maximum pipe height difference: 20 m Indoor unit technical data Exchanger type : Brazed stainless steel plates Expansion vessel volume: 10 litres Water safety valve setting: 3 bar Minimum system water content: 40 litres System piping diameter: 1" gas F DHW piping diameter: 3/4" gas F Liquid pipe diameter : 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Electrical data Power supply (V,Hz, Ø) : 220~240/50/1 Refrigerant gas : R32 Dimensions and weight External unit dimensions (WxHxD): 1008x712x426 mm Outdoor unit weight: 58.0 Kg Internal unit dimensions (WxHxD): 422x702x320 mm 5 years without worries Ferroli OMNIA S 3.2 Reversible heat pumps for split installation with DC inverter compressor Quietness, efficiency and design OMNIA S 3.2 is the new range of split heat pumps Full Inverter R32 by Ferroli. The range includes an Outdoor Unit with the heart of the refrigerant circuit, from the compressor to the fan with the air side exchanger, which is connected to the refrigerant gas pipes towards the Indoor Unit. The Indoor Unit, on the other hand, contains the heart of the hydraulic circuit of the generator with all the main pre-installed components, such as the high-efficiency circulator and the expansion vessel, to safely allow quick and practical installation The split installation of OMNIA S 3.2 , with only the gas pipes between the outdoor and indoor unit, is synonymous with security against any freezing problem, even at the coldest temperatures (down to -25°C) and in the absence of electricity. All units meet the most extreme winter and summer air conditioning requirements, they can in fact produce hot water up to 65°C , which makes them suitable for practically all heating systems, whether radiant, fan coil or radiator, including the production of domestic hot water (DHW), via an external boiler The new conception Full Inverter by Ferroli uses DC inverter modulations on the 3 main energy-intensive components of the machine, i.e. compressor, fan and pump. This allows you to modulate the power supplied by finely tracking the thermal load and allowing the user very high efficiencies and important energy savings . Also, the concept Full Inverter by Ferroli guarantees sound levels among the lowest on the market, avoiding sudden changes in the network and guaranteeing a longer useful life for the components. Indoor and outdoor unit of OMNIA 3.2 The Outdoor Unit contains the heart of the refrigerant circuit, while the Internal Unit the heart of the hydraulic circuit. They are connected to each other by pipes R32 ecological refrigerant gas , which has allowed us to combine high efficiency with a reduced environmental impact. Thanks to his GWP of 675 , about a third of the GWP of R410a, helps reduce CO2 equivalent emissions, the main causes of global warming The heat pumps use the Outdoor Unit to extract heat from the air outside the home and convey it to the water in your system, via an exchanger in the Indoor Unit. That's exactly why they manage to get such high efficiencies , exploiting so renewable the energy already present in the air outside the home The new conception Full Inverter by Ferroli then does the rest, tracking the thermal loads precisely and without waste (modulating the compressor, pump and fan), manages to achieve even greater efficiencies, guaranteeing important savings in bills , without stress on the components and with very low sound levels OMNIA S 3.2 it can be used both as the sole generator of the system and integrated with other sources such as a Ferroli boiler The control system The user interface has been equipped with capsense technology with 2.8” graphic display, which allows the user to interact with the product easily and extremely simply Modbus protocol It can be interfaced to BMS/BACS automation and management systems Heating and cooling Full Inverter modulation finely follows the desired setpoints, with the possibility of setting heating and cooling climatic curves, further optimizing consumption for the user Domestic hot water production When the DHW temperature probe calls the machine, it automatically switches to the domestic hot water tank with dedicated DHW set point. 3-way diverter valve supplied as standard Smart Grid input from photovoltaic and grid Digital Smart Grid inputs for the management of an input from the photovoltaic system and from the electricity grid. These allow you to optimize consumption and bill costs DHW tank electrical resistance The DHW electrical integration serves as integration, anti-legionella or reserve source in the event of an anomaly Fast DHW Priority to DHW production to bring the storage tank to the set point in the shortest possible time Anti-legionella function Allows you to set anti-legionella weekly cycles Silent mode Reduces the frequency of the compressor and the speed of the fan, so as to significantly reduce noise. Programmable on time slots ON/OFF From external contact. Activation and deactivation via an external contact, for example from a zone thermostat Hot / cold From external contacts. Summer/winter switching signal from outside, for example from the zone thermostat ECO function Dedicated setpoint for " Eco " operation. Settable with daily time band Anti-freeze protection Heat pump operation with circulator ON and possible electric booster Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €3.275,00

  • immagine-1-ferroli-pompa-di-calore-reversibile-ferroli-omnia-m-3.2-da-16-kw-2cp000gf-monofase-per-installazione-esterna-con-compressore-dc-inverter-r-32-wi-fi-con-comando-incluso

    Ferroli Ferroli Omnia M 3.2 16 Kw 2cp000gf Single-Phase Reversible Heat Pump For Outdoor Installation With R-32 Dc Inverter Compressor Wi-Fi With Control Included

    ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS   FREE FIRST START-UP Technical features Model : OMNIA M 3.2 16 Product code : 2CP000GF Command included Energy efficiency Energy class in heating at 35° C: A+++ Energy class in heating at 55° C: A+++ SCOP heating with water set at 35 °C : 4.62 SCOP heating with water set at 45 °C : 3.41 SEER cooling with water set at 7 °C: 4.69 SEER cooling with water set at 18 °C: 6.75 Performance   Heating Useful power in heating with water set at 35° C: 15.9 kW Useful power in heating with water set at 45° C: 16.0 kW Useful power in heating with water set at 55°C: 16.0 kW Absorbed power with water set at 35° C: 3.53 kW Absorbed power with water set at 45° C: 4.57 kW Absorbed power with water set at 55° C: 5.61 kW Water flow rate with water set at 35° C : 2735 l/h Water flow rate with water set at 45° C : 2752 l/h Water flow rate with water set at 55° C : 1720 l/h Cooling down Useful power in cooling with water set at 7 °C: 14.0 kW Useful power in cooling with water set at 18 °C: 13.6 kW Absorbed power with water set at 7° C: 5.60 kW Absorbed power with water set at 18° C: 3.77 kW Water flow rate with water set at 7° C : 2408 l/h Water flow rate with water set at 18° C : 2339 l/h Technical data Compressor type : Twin Rotary DC Number of compressors : 1 Number of cooling circuits: 1 Type of fans : DC axial Number of fans : 1 Expansion vessel volume: 5 litres Water safety valve setting: 3 bar Minimum system water content: 25 litres Sound power level in heating : 56 ~ 69 dB(A) Sound power level in cooling : 56 ~ 69 dB(A) Electrical data Power supply (V,Hz, Ø) : 220~240/50/1 Refrigerant gas : R32 Maximum absorbed current: 27A Installation data Delivery pipe diameter: 1 ¼” M Return pipe diameter: 1 ¼” M Dimensions and weight Dimensions (WxHxD): 1385x865x526 mm Weight : 129Kg 5 years without worries Ferroli OMNIA M 3.2 Reversible heat pumps for outdoor installation with DC inverter compressor A heat pump with silent and ecological efficiency This series of air-to-water heat pumps with low environmental impact ecological gas R32 satisfies the winter and summer air conditioning needs of residential and commercial systems of small and medium power. All the units are suitable for outdoor installation and being able to produce water up to 65°C they can be used in radiant systems, fan coils, radiators and for the indirect production of DHW domestic hot water via an optional external boiler The units are characterized by the use of a DC inverter compressor which allows the power supplied to be modulated and are complete with a hydronic kit made up of all the essential components for quick and safe installation. The units are characterized by high energy efficiency and low sound levels which allow them to be used as a single generator serving the system or integrated with other energy sources such as electric support heaters or boilers All units are supplied as standard with a DHW tank water temperature probe and with an external air temperature probe, already installed on the unit, to carry out climatic regulation in heating and cooling. All units are carefully built and individually tested in the factory. The installation requires only the electrical and hydraulic connections. In a system it is possible to connect a maximum of 6 units in cascade; one of them will be “MASTER” while the others will be “SLAVE” units. Refrigerant circuit Contained inside the unit to facilitate maintenance operations, it is equipped with a compressor with a Twin rotary type DC Inverter motor to guarantee greater dynamic balancing and reduce vibrations. It is placed on rubber anti-vibration mounts and wrapped in a double layer of sound-absorbing material to reduce noise. The compressor is also equipped with a crankcase oil heater. The circuit is completed by a brazed stainless steel plate heat exchanger complete with antifreeze heater, axial fans with brushless DC motor complete with safety grilles, finned coil with anti-corrosion treatment made up of copper pipes and aluminum fins. All units are equipped with variable speed control of the fans which allows operation with low outside temperatures in cooling and high outside temperatures in heating Hydraulic circuit Contained inside the unit to facilitate maintenance operations, it is equipped as standard with a low-consumption circulator with brushless DC motor, water flow switch, automatic air vent, water pressure gauge, expansion tank, safety valve, Y-shaped water filter The plate heat exchanger and all the hydraulic circuit pipes are thermally insulated to prevent the formation of condensate and reduce heat loss Air source The benefits offered by this technology Aerothermal energy is the energy of the future. Ferroli aerothermal heat pumps use clean technology capable of obtaining up to 79% of the energy supplied for home comfort from the outside air. Ferroli aerothermal heat pumps are designed to provide cooling in summer, heating in winter and/or domestic hot water throughout the year. These latest generation heat pumps with inverter technology and the use of an ecological gas such as R32 do not produce heat from the combustion of a fuel but, simply with minimal energy consumption, exploit the energy in the air and transfer it to the inside the house Greater efficiency The OMNIA M 3.2 monobloc range has energy class A++ for the production of water at 55ºC and A+++ for the water produced at 35°C Compact outdoor unit. More space available Thanks to the adoption of a compact and small-sized unit, especially for the more powerful models, OMNIA M 3.2 can be easily placed outside the house, guaranteeing more available space inside Quick and easy installation Being a packaged unit, installation costs and times are significantly reduced. The interconnection of the refrigerant between the units is not necessary, as the entire refrigerant circuit is contained in the equipment, it is not even necessary to make a connection to bring the fuel, nor to create a flue gas evacuation duct. In addition, the device includes all the plumbing elements necessary for correct and quick connection to the plumbing and DHW heating system. Ideal combination with low temperature systems The OMNIA M 3.2 range can be easily installed in combination with low temperature systems, connecting fan coils, radiators, underfloor heating, to obtain maximum energy efficiency and maximum domestic comfort Easy integration with an existing boiler OMNIA M 3.2 can be combined and integrated with any boiler in the system. The control of the device, based on the external temperature and the required operating conditions, optimizes the production of heat for heating and DHW, using the device with the best efficiency Production of hot water at 65°C with low external temperature The OMNIA M 3.2 range is able to supply hot water at 60°C with an external temperature down to -15°C and at 40°C with an external temperature down to -25°C, without any type of support/accessory. With cold but positive temperatures OMNIA M 3.2 can produce hot water up to 65°C Protection against freezing of hydraulic components without the need to add glycol If low outside temperatures are detected, the circulation pump and the electric antifreeze heater of the plate heat exchanger are activated, thus preventing freezing of the hydraulic components. There is therefore no need to add glycol to the system Control system Operating principle The general control system allows monitoring of all the functions of the inverter system and of the correct functioning of the compressor. It also incorporates regulation algorithms using predefined climatic curves that can be selected by the customer, the management of a DHW circuit, the setting of time slots for noise reduction during the night, alarm signaling, pump block prevention and integration with external heat generators. The user interface consists of a wired remote controller which allows the management of: Management of 2 distinct zones, direct + mixed The unit is able to manage the pumps of both zones and for the mixed in addition the mixing valve and water delivery temperature probe Photovoltaic and Smart Grid management The management of a photovoltaic system and of the "intelligent grid" function is ensured by 2 digital inputs on the PCB with specific operating logics Heating and cooling system The unit activates in hot or cold mode, works by modulating the frequency of the compressor to keep the water temperature produced at the setpoint value set via the controller Domestic hot water production The unit activates in heating mode to maintain the temperature of a DHW tank at the set point value. A 3-way diverter valve is required (not supplied) and a temperature probe, supplied as standard, to be inserted in a well of the DHW boiler. Additional energy sources These sources can be activated in Integration or replacement of the heat pump during heating service or for DHW production and in case the heat pump does not work. Cascade management of several units Possibility of managing up to 6 units in cascade even with different powers with a single controller connected to the Master. In the event of an anomaly in one "Slave", the others can function normally DHW tank electric resistance It is possible to manage a possible integration and/or reserve electric resistance and for the anti-legionella function Fast DHW Function that can be activated manually which allows you to give priority to domestic hot water by bringing the DHW tank to the set point in the shortest possible time Anti-legionella function Weekly anti-legionella cycles can be set. The heat pump must be integrated with a DHW boiler electric heater or boiler Silenced mode 2 levels of silence are possible which, if active, according to an hourly programming, involve a reduction in the maximum frequency of the compressor and in the speed of the fan to reduce the noise emitted perhaps during the night and the power absorbed by the unit ON/OFF The unit can be switched on and off via an external contact. It can be operated from the controller keyboard Hot/Cold The unit can be switched on and off in cold and hot mode via 2 external contacts ECO Possibility of defining time slots and related setpoint for ECO modes in hot and cold mode Weekly programming Allows differentiated time programming for each day of the week by defining the working mode and setpoint for each band Anti-freeze protection Guaranteed up to an external air temperature of -20°C thanks to the heat pump itself operating in hot mode, to the standard anti-freeze electrical resistance and to the electric booster if installed. Remote control of the unit via APP Available for iOS and Android Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €3.821,00

  • immagine-1-ferroli-pompa-di-calore-reversibile-ferroli-omnia-m-3.2-da-14-kw-2cp000if-trifase-per-installazione-esterna-con-compressore-dc-inverter-r-32-wi-fi-con-comando-incluso

    Ferroli Ferroli Omnia M 3.2 14 Kw 2cp000if Three-Phase Reversible Heat Pump For Outdoor Installation With R-32 Dc Inverter Compressor Wi-Fi With Control Included

    ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS   FREE FIRST START-UP Technical features Model : OMNIA M 3.2 14-T Product code : 2CP000IF Command included Energy efficiency Energy class in heating at 35° C: A+++ Energy class in heating at 55° C: A+++ SCOP heating with water set at 35 °C : 4.72 SCOP heating with water set at 45 °C : 3.47 SEER cooling with water set at 7 °C: 4.83 SEER cooling with water set at 18 °C: 6.85 Performance   Heating Useful power in heating with water set at 35° C: 14.5 kW Useful power in heating with water set at 45° C: 14.1 kW Useful power in heating with water set at 55° C: 13.8 kW Absorbed power with water set at 35° C: 3.15 kW Absorbed power with water set at 45° C: 3.92 kW Absorbed power with water set at 55° C: 4.68 kW Water flow rate with water set at 35° C : 2494 l/h Water flow rate with water set at 45° C : 2425 l/h Water flow rate with water set at 55° C : 1484 l/h Cooling down Useful power in cooling with water set at 7 °C: 12.4 kW Useful power in cooling with water set at 18 °C: 12.9 kW Absorbed power with water set at 7° C: 4.96 kW Absorbed power with water set at 18° C: 3.49 kW Water flow rate with water set at 7° C : 2133 l/h Water flow rate with water set at 18° C : 2219 l/h Technical data Compressor type : Twin Rotary DC Number of compressors : 1 Number of cooling circuits: 1 Type of fans : DC axial Number of fans : 1 Expansion vessel volume: 5 litres Water safety valve setting: 3 bar Minimum system water content: 25 litres Sound power level in heating : 56 ~ 65 dB(A) Sound power level in cooling : 56 ~ 65 dB(A) Electrical data Power supply (V,Hz, Ø) : 380~415/50/3 Refrigerant gas : R32 Maximum absorbed current: 11A Installation data Delivery pipe diameter: 1 ¼” M Return pipe diameter: 1 ¼” M Dimensions and weight Dimensions (WxHxD): 1385x865x526 mm Weight : 144Kg 5 years without worries Ferroli OMNIA M 3.2 Reversible heat pumps for outdoor installation with DC inverter compressor A heat pump with silent and ecological efficiency This series of air-to-water heat pumps with low environmental impact ecological gas R32 satisfies the winter and summer air conditioning needs of residential and commercial systems of small and medium power. All the units are suitable for outdoor installation and being able to produce water up to 65°C they can be used in radiant systems, fan coils, radiators and for the indirect production of DHW domestic hot water via an optional external boiler The units are characterized by the use of a DC inverter compressor which allows the power supplied to be modulated and are complete with a hydronic kit made up of all the essential components for quick and safe installation. The units are characterized by high energy efficiency and low sound levels which allow them to be used as a single generator serving the system or integrated with other energy sources such as electric support heaters or boilers All units are supplied as standard with a DHW tank water temperature probe and with an external air temperature probe, already installed on the unit, to carry out climatic regulation in heating and cooling. All units are carefully built and individually tested in the factory. The installation requires only the electrical and hydraulic connections. In a system it is possible to connect a maximum of 6 units in cascade; one of them will be “MASTER” while the others will be “SLAVE” units. Refrigerant circuit Contained inside the unit to facilitate maintenance operations, it is equipped with a compressor with a Twin rotary type DC Inverter motor to guarantee greater dynamic balancing and reduce vibrations. It is placed on rubber anti-vibration mounts and wrapped in a double layer of sound-absorbing material to reduce noise. The compressor is also equipped with a crankcase oil heater. The circuit is completed by a brazed stainless steel plate heat exchanger complete with antifreeze heater, axial fans with brushless DC motor complete with safety grilles, finned coil with anti-corrosion treatment made up of copper pipes and aluminum fins. All units are equipped with variable speed control of the fans which allows operation with low outside temperatures in cooling and high outside temperatures in heating Hydraulic circuit Contained inside the unit to facilitate maintenance operations, it is equipped as standard with a low-consumption circulator with brushless DC motor, water flow switch, automatic air vent, water pressure gauge, expansion tank, safety valve, Y-shaped water filter The plate heat exchanger and all the hydraulic circuit pipes are thermally insulated to prevent the formation of condensate and reduce heat loss Air source The benefits offered by this technology Aerothermal energy is the energy of the future. Ferroli aerothermal heat pumps use clean technology capable of obtaining up to 79% of the energy supplied for home comfort from the outside air. Ferroli aerothermal heat pumps are designed to provide cooling in summer, heating in winter and/or domestic hot water throughout the year. These latest generation heat pumps with inverter technology and the use of an ecological gas such as R32 do not produce heat from the combustion of a fuel but, simply with minimal energy consumption, exploit the energy in the air and transfer it to the inside the house Greater efficiency The OMNIA M 3.2 monobloc range has energy class A++ for the production of water at 55ºC and A+++ for the water produced at 35°C Compact outdoor unit. More space available Thanks to the adoption of a compact and small-sized unit, especially for the more powerful models, OMNIA M 3.2 can be easily placed outside the house, guaranteeing more available space inside Quick and easy installation Being a packaged unit, installation costs and times are significantly reduced. The interconnection of the refrigerant between the units is not necessary, as the entire refrigerant circuit is contained in the equipment, it is not even necessary to make a connection to bring the fuel, nor to create a flue gas evacuation duct. In addition, the device includes all the plumbing elements necessary for correct and quick connection to the plumbing and DHW heating system. Ideal combination with low temperature systems The OMNIA M 3.2 range can be easily installed in combination with low temperature systems, connecting fan coils, radiators, underfloor heating, to obtain maximum energy efficiency and maximum domestic comfort Easy integration with an existing boiler OMNIA M 3.2 can be combined and integrated with any boiler in the system. The control of the device, based on the external temperature and the required operating conditions, optimizes the production of heat for heating and DHW, using the device with the best efficiency Production of hot water at 65°C with low external temperature The OMNIA M 3.2 range is able to supply hot water at 60°C with an external temperature down to -15°C and at 40°C with an external temperature down to -25°C, without any type of support/accessory. With cold but positive temperatures OMNIA M 3.2 can produce hot water up to 65°C Protection against freezing of hydraulic components without the need to add glycol If low outside temperatures are detected, the circulation pump and the electric antifreeze heater of the plate heat exchanger are activated, thus preventing freezing of the hydraulic components. There is therefore no need to add glycol to the system Control system Operating principle The general control system allows monitoring of all the functions of the inverter system and of the correct functioning of the compressor. It also incorporates regulation algorithms using predefined climatic curves that can be selected by the customer, the management of a DHW circuit, the setting of time slots for noise reduction during the night, alarm signaling, pump block prevention and integration with external heat generators. The user interface consists of a wired remote controller which allows the management of: Management of 2 distinct zones, direct + mixed The unit is able to manage the pumps of both zones and for the mixed in addition the mixing valve and water delivery temperature probe Photovoltaic and Smart Grid management The management of a photovoltaic system and of the "intelligent grid" function is ensured by 2 digital inputs on the PCB with specific operating logics Heating and cooling system The unit activates in hot or cold mode, works by modulating the frequency of the compressor to keep the water temperature produced at the setpoint value set via the controller Domestic hot water production The unit activates in heating mode to maintain the temperature of a DHW tank at the set point value. A 3-way diverter valve is required (not supplied) and a temperature probe, supplied as standard, to be inserted in a well of the DHW boiler. Additional energy sources These sources can be activated in Integration or replacement of the heat pump during heating service or for DHW production and in case the heat pump does not work. Cascade management of several units Possibility of managing up to 6 units in cascade even with different powers with a single controller connected to the Master. In the event of an anomaly in one "Slave", the others can function normally DHW tank electric resistance It is possible to manage a possible integration and/or reserve electric resistance and for the anti-legionella function Fast DHW Function that can be activated manually which allows you to give priority to domestic hot water by bringing the DHW tank to the set point in the shortest possible time Anti-legionella function Weekly anti-legionella cycles can be set. The heat pump must be integrated with a DHW boiler electric heater or boiler Silenced mode 2 levels of silence are possible which, if active, according to an hourly programming, involve a reduction in the maximum frequency of the compressor and in the speed of the fan to reduce the noise emitted perhaps during the night and the power absorbed by the unit ON/OFF The unit can be switched on and off via an external contact. It can be operated from the controller keyboard Hot/Cold The unit can be switched on and off in cold and hot mode via 2 external contacts ECO Possibility of defining time slots and related setpoint for ECO modes in hot and cold mode Weekly programming Allows differentiated time programming for each day of the week by defining the working mode and setpoint for each band Anti-freeze protection Guaranteed up to an external air temperature of -20°C thanks to the heat pump itself operating in hot mode, to the standard anti-freeze electrical resistance and to the electric booster if installed. Remote control of the unit via APP Available for iOS and Android Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €4.580,00

  • Sale -38%Last stock! immagine-1-baxi-offerta-pompa-di-calore-aria-acqua-monoblocco-inverter-baxi-auriga-5m-r-32-monofase-a7794318-completo-di-comando-novita

    BAXI Offer Baxi Auriga 5m R-32 Single-Phase Air-Water Monobloc Inverter A7794318 Complete With Control - New

    ATTENTION ! OFFER VALID UNTIL STOCKS LAST FIRST START UP INCLUDED! Technical features Thermal power (air +7°C (bs) / +6°C (bu) and delivery temperature of +35°C - EN 14511): 4.65 kW COP: 5.00 Cooling capacity (air +35°C (bs) and delivery temperature +7°C - EN 14511): 4.60 kW EER: 2.98 SEER: 4.71 R32 refrigerant charge: 2.00 kg Number/type of compressors: 1/rotary DC inverter Number of fans: 1 Nominal water flow (winter operation): 0.80 m³/h Circulation pump useful head: 55 kPa Inlet/outlet hydraulic connections: 1” male / 1” male Power supply voltage: 230V 1P+N+T Power supply frequency: 50Hz Overall dimensions H x W x D: 945mm x 1210mm x 402mm Weight: 92kg Sound power: 61dB(A) Sound pressure at 1 meter in free field on a reflective surface: 48.8 dB(A) BAXI AURIGA Inverter Monobloc Air-Water Heat Pumps Baxi introduces Auriga , the range of inverter packaged air-to-water heat pumps with single-phase and three-phase power supply. The range is characterized by the ease and simplicity of installation . Furthermore, the increased head of the on-board circulator allows the unit to be installed in large-scale systems, to cover greater distances from the heating plant or to install the unit directly to serve the fan coils. The range is wide and consists of 8 models from 4 to 16 kW, single-phase and three-phase versions Wide range of powers from 4 to 16 kW to satisfy all system requirements: heating, cooling and DHW production Easy to install in various living contexts, the increased head pump allows you to cope with greater pressure drops such as large systems or directly serving the fan coils STANDARD complete hydraulic equipment circulation pump, flow switch, expansion tank, safety valve, pressure gauge and “Y” filter Remote control panel control of system functions, programming and parameter verification. Furthermore, the connection via Modbus allows integration with BMS systems ErP Energy Labeling the labeling regulation (EU Regulation 2017/1369) requires the labeling of products according to a decreasing energy scale that goes from A+++ to D (in heating) and from A+ to F (in sanitary). The 5M/7M/9M models achieve an efficiency of A+++ in low temperature heating Components > Twin rotary DC inverter compressor : complete with internal thermal protection and crankcase heater, it is mounted on vibration dampers and wrapped around an insulating cap to reduce the transmission of noise and vibrations due to operation > Water-refrigerant exchanger : with brazed plates in AISI 316 steel with external anti-condensation insulation in expanded polypropylene and antifreeze resistance to prevent the formation of ice in the exchanger > Air-refrigerant exchanger : finned aluminum coil with hydrophilic treatment to facilitate the outflow of the condensate, mechanically expanded copper pipes with internal shaping to increase the heat exchange Furthermore, the optimized circuitry reduces the formation of ice in the coil during heat pump operation > Fan : axial fan directly coupled to the high efficiency brushless DC variable speed motor. The fan is installed on aerodynamic nozzles and safety grilles > Refrigerant circuit : made of pickled copper, it includes the electronic expansion valve, drier filters, high and low pressure switches, pressure transducer, cycle inversion valves, liquid receiver and separator, refrigerant injection valve on the suction side > Hydraulic circuit : in addition to the brazed plate heat exchanger, the unit includes the high head circulator, the expansion vessel, the safety valve, the flow switch, the pressure gauge and the air vent valve and the metal mesh Y-filter (assembly by the installer) > Electrical panel : includes fuse protection of the main internal components; the terminal block is divided into a power section for supplying the unit and a control terminal block for connecting auxiliary inputs and outputs and connection to the control panel Main Features BAXI AURIGA Maximum energy efficiency Monobloc system for the production of heating, cooling and DHW Wide operating range, with external air down to -25°C in heating, up to 46°C in cooling DHW system management: production up to 60°C, storage tank temperature management, DHW recirculation pump and solar thermal integration Suitable for integration with radiant terminals, fan coils and mixed systems Integrated management with various plant systems: boiler integration, solar integration, management of diverter valves and secondary circuit pump Single-phase and three-phase power supply Compressor with DC inverter technology with high modulation range Modbus network connection Low GWP R32 refrigerant Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €3.900,00€2.399,00

  • immagine-1-beretta-pompa-di-calore-idronica-aria-acqua-beretta-hydro-unit-m-010-monofase-r-32-20191953

    BERETTA Air-Water Hydronic Heat Pump Beretta Hydro Unit M 010 Single-Phase R-32 20191953

    ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS   FREE FIRST START-UP Technical features Model : HYDRO UNIT M 010 Product code : 20191953 Optional REC10MH control Energy efficiency Energy class in heating at 35° C: A+++ Energy class in heating at 55° C: A++ Heating COP with water set at 35°C: 4.95 Heating COP with water set at 45°C: 3.75 Heating COP with water set at 55°C: 3.10 EER cooling with water set at 7°C: 3.25 EER cooling with water set at 18°C: 4.55 Performance   Heating Useful power in heating with water set at 35° C: 10.00 kW Useful power in heating with water set at 45° C: 10.00 kW Useful power in heating with water set at 55° C: 9.50 kW Absorbed power with water set at 35° C: 2.02 kW Absorbed power with water set at 45° C: 2.67 kW Absorbed power with water set at 55° C: 3.06 kW Cooling down Useful power in cooling with water set at 7 °C: 8.20 kW Useful power in cooling with water set at 18 °C: 9.90 kW Absorbed power with water set at 7° C: 2.52 kW Absorbed power with water set at 18° C: 2.18 kW Technical data Hydronic circuit maximum operating pressure: 3 bar Maximum absorbed power: 0.043 kW System expansion tank: 8 litres Sound data Sound power : 60 dB(A) Sound pressure : 50.5 dB(A) Electrical data Power supply (V,Hz, Ø) : 220~240/50/1 Refrigerant gas : R32 Dimensions and weight Dimensions (LxHxP): 1385x945x526 mm Empty weight: 121.0 kg Beretta HYDRO UNIT M Inverter Monoblock Air-Water Hydronic Heat Pumps These units are used for both heating and cooling applications as well as domestic hot water tanks. They can be combined with fan coil units, underfloor heating applications, low temperature high efficiency radiators, domestic hot water tanks and solar kits, all of which are field powered. A wired controller is supplied with the unit. The backup heater, available as an accessory, can increase the heating capacity in cold outside temperatures. The backup heater also serves as a backup in the event of a malfunction and as a freeze protection of the outdoor water pipes during the winter. Efficiency and sustainability The heat pumps of the HYDRO UNIT M series use R32 as the refrigerant gas, a gas with a lower Global Warming Potential than the traditional gases used. The design of a new sealed circuit for fluorinated gases, the use of R32, reduced load volumes, lower CO2 emissions and increased energy efficiency are the characteristics that differentiate HYDRO UNIT M and increase its sustainability environmental. Quietness The low noise level is guaranteed by the construction features used and can be further reduced thanks to the silent mode programming, available to the customer Antifreeze function The HYDRO UNIT M heat pump is foreseen for outdoor installation and equipped with the ANTIFREEZE function for the protection of the entire hydraulic circuit. This customer-programmable function activates automatically whenever the water temperature in the system drops below a pre-set value, ensuring the protection of the entire system Better performance The ten models available offer powers from 4 kW to 16 kW , with fast response to requests and reduced energy consumption which guarantee energy class A+++ up to 35°C and A++ up to 55°C HP KEYMARK Certified The design meets the requirements of the voluntary European HP KEYMARK certification Easy and flexible Installing HYDRO UNIT M is easy thanks to the hydronic kit that comes with the monobloc and which contains all the essential components. HYDRO UNIT M is flexible thanks to its ability to respond quickly to the real needs of the environments to be served Functional elements Beretta Hydro Unit M Inverter Control Board Maximizes power under critical load conditions and provides stability and efficiency at part loads AISI 316 steel plate heat exchanger : protected with closed cell anti-condensation insulation, it offers high heat exchange efficiency Control board Operating parameters constantly analyzes the ambient temperature and the water temperature to activate the different components and meet the demand Hydronic module Including low consumption circulator, expansion vessel, automatic vent valve and safety valve Electronic expansion valve Optimizes the flow of the refrigerant fluid in every situation Twin rotary compressor Inverter System design including DC twin rotary compressor, fan motor and pump ensures precise motor speed control for the right power needed to perfectly match actual load and save energy Fan Special design of the blade and its edge that allows optimizing the flow surface, improving efficiency and reducing fan noise Heat exchange coil With extended surface and aluminum fins Install more Hydro Unit M HYDRO UNIT M offers the possibility of connecting up to six units to each other for the heating, cooling and domestic hot water needs of small condominiums and light commercial contexts. Each of the units responds individually to the demands of the environment in which it is installed Easily manage the plant Advanced remote control This module, present in every HYDRO UNIT M installation, has a multilingual display and allows you to: Manage up to six units connected in cascade Activate the programmed functions such as the Antifreeze function and the Vacation function, for the serenity of the family REC10MH management module Designed for full-electric and hybrid applications, this module is installed inside the home and allows the user to easily manage the entire system. If the system is equipped with a Hybrid distribution system, REC10MH allows you to manage the multi-zone system to optimize the operation of the system. The module is equipped with a color display and a multilingual menu USB Each HYDRO UNIT M is equipped with a USB port to connect the USB flash memory to update the unit firmware Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €3.100,00

  • immagine-1-beretta-pompa-di-calore-idronica-aria-acqua-beretta-hydro-unit-m-004-monofase-r-32-20191950

    BERETTA Air-Water Hydronic Heat Pump Beretta Hydro Unit M 004 Single-Phase R-32 20191950

    ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS   FREE FIRST START-UP Technical features Model : HYDRO UNIT M 004 Product Code: 20191950 Optional REC10MH control Energy efficiency Energy class in heating at 35° C: A+++ Energy class in heating at 55° C: A++ Heating COP with water set at 35°C: 5.10 Heating COP with water set at 45°C: 3.80 Heating COP with water set at 55°C: 2.95 EER cooling with water set at 7°C: 3.45 EER cooling with water set at 18°C: 5.50 Performance   Heating Useful power in heating with water set at 35° C: 4.20 kW Useful power in heating with water set at 45° C: 4.30 kW Useful power in heating with water set at 55° C: 4.40 kW Cooling down Useful power in cooling with water set at 7 °C: 4.70 kW Useful power in cooling with water set at 18 °C: 4.50 kW Technical data Sound power : 55 dB(A) Sound pressure : 45 dB(A) Electrical data Power supply (V,Hz, Ø) : 220~240/50/1 Refrigerant gas : R32 Dimensions and weight Dimensions (LxHxP): 1295x792x429 mm Empty weight: 98.0 kg Beretta HYDRO UNIT M Inverter Monoblock Air-Water Hydronic Heat Pumps These units are used for both heating and cooling applications as well as domestic hot water tanks. They can be combined with fan coil units, underfloor heating applications, low temperature high efficiency radiators, domestic hot water tanks and solar kits, all of which are field powered. A wired controller is supplied with the unit. The backup heater, available as an accessory, can increase the heating capacity in cold outside temperatures. The backup heater also serves as a backup in the event of a malfunction and as a freeze protection of the outdoor water pipes during the winter. Efficiency and sustainability The heat pumps of the HYDRO UNIT M series use R32 as the refrigerant gas, a gas with a lower Global Warming Potential than the traditional gases used. The design of a new sealed circuit for fluorinated gases, the use of R32, reduced load volumes, lower CO2 emissions and increased energy efficiency are the characteristics that differentiate HYDRO UNIT M and increase its sustainability environmental. Quietness The low noise level is guaranteed by the construction features used and can be further reduced thanks to the silent mode programming, available to the customer Antifreeze function The HYDRO UNIT M heat pump is foreseen for outdoor installation and equipped with the ANTIFREEZE function for the protection of the entire hydraulic circuit. This customer-programmable function activates automatically whenever the water temperature in the system drops below a pre-set value, ensuring the protection of the entire system Better performance The ten models available offer powers from 4 kW to 16 kW , with fast response to requests and reduced energy consumption which guarantee energy class A+++ up to 35°C and A++ up to 55°C HP KEYMARK certified The design meets the requirements of the voluntary European HP KEYMARK certification Easy and flexible Installing HYDRO UNIT M is easy thanks to the hydronic kit that comes with the monobloc and which contains all the essential components. HYDRO UNIT M is flexible thanks to its ability to respond quickly to the real needs of the environments to be served Functional elements Beretta Hydro Unit M Inverter Control Board Maximizes power under critical load conditions and provides stability and efficiency at part loads AISI 316 steel plate heat exchanger : protected with closed cell anti-condensation insulation, it offers high heat exchange efficiency Control board Operating parameters constantly analyzes the ambient temperature and the water temperature to activate the different components and meet the demand Hydronic module Including low consumption circulator, expansion vessel, automatic vent valve and safety valve Electronic expansion valve Optimizes the flow of the refrigerant fluid in every situation Twin rotary compressor Inverter System design including DC twin rotary compressor, fan motor and pump ensures precise motor speed control for the right power needed to perfectly match actual load and save energy Fan Special design of the blade and its edge that allows optimizing the flow surface, improving efficiency and reducing fan noise Heat exchange coil With extended surface and aluminum fins Install more Hydro Unit M HYDRO UNIT M offers the possibility of connecting up to six units to each other for the heating, cooling and domestic hot water needs of small condominiums and light commercial contexts. Each of the units responds individually to the demands of the environment in which it is installed Easily manage the plant Advanced remote control This module, present in every HYDRO UNIT M installation, has a multilingual display and allows you to: Manage up to six units connected in cascade Activate the programmed functions such as the Antifreeze function and the Vacation function, for the serenity of the family REC10MH management module Designed for full-electric and hybrid applications, this module is installed inside the home and allows the user to easily manage the entire system. If the system is equipped with a Hybrid distribution system, REC10MH allows you to manage the multi-zone system to optimize the operation of the system. The module is equipped with a color display and a multilingual menu USB Each HYDRO UNIT M is equipped with a USB port to connect the USB flash memory to update the unit firmware Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €2.550,00

  • immagine-1-baxi-pompa-di-calore-aria-acqua-monoblocco-inverter-baxi-auriga-12t-a-r-32-trifase-a7794578-con-pannello-di-comando-remoto-incluso-novita

    BAXI Air-Water Heat Pump Monoblock Inverter Baxi Auriga 12t-A R-32 Three-Phase A7794578 With Remote Control Panel Included - New

    ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS FIRST START UP INCLUDED! Technical features Model : Auriga 12T-A Product code : A7794578 Remote Control Panel A7799122 Heating with low temperature application External air temperature 7°C - 87% RH Water temperature 30/35°C Nonimal thermal power: 12.10 kW Absorbed electrical power: 2.44 kW COP: 4.95 External air temperature 7°C - 87% RH Water temperature 35°C Normal thermal power: 10.00 kW Absorbed electrical power: 3.33 kW COP : 3.00 Heating with medium temperature application External air temperature 7°C - 87% RH Water temperature 45°C Nonimal thermal power: 12.30 kW Absorbed electrical power: 3.32 kW COP: 3.70 External air temperature 7°C - 87% RH Water temperature 55°C Nonimal thermal power: 11.90 kW Absorbed electrical power: 3.90 kW COP: 3.05 Cooling External air temperature 35°C - Water temperature 18°C Nonimal cooling capacity: 12.00 kW Absorbed electrical power: 3.04 kW EER: 3.95 External air temperature 35°C - Water temperature 7°C Nonimal cooling capacity: 11.50 kW Absorbed electrical power: 4.18 kW EER: 2.75 Energy efficiency Seasonal low-temperature space heating energy efficiency : 189% Seasonal space heating energy efficiency at medium temperature : 135% Low temperature seasonal energy efficiency class: A+++ Seasonal energy efficiency class at medium temperature: A++ Performance Exchanger water flow rate: 2.09 m 3 /h Available pump head: 60 kPa Sound power level : 65 dB(A) Sound pressure level : 53 dB(A) Electrical data Power supply (V,Hz, Ø) : 380~415/50/3 Refrigerant gas : R32 Operating limits Heating External air temperature : -25°C ~ 35°C Introduced water temperature : 12°C~ 65°C Cooling down External air temperature : -5°C ~ 43°C Introduced water temperature : 5°C ~ 25°C Installation data Plumbing pipe diameter: 1'' 1/4 Dimensions and weight Dimensions (HxWxD): 865x1385x488 mm Empty weight: 160 Kg BAXI AURIGA Inverter Monobloc Air-Water Heat Pumps introducing the new Auriga . The range is characterized by the ease and simplicity of installation, as well as for reliability and excellent performance . Furthermore, the high head of the circulator, fitted as STANDARD inside the unit, allows installation in large-sized systems, to cover greater distances from the boiler room or to install the unit directly at the service of the fan coils. The range expands and consists of well 8 models from 4 to 16 kW, single-phase and three-phase versions Wide range of powers from 4 to 16 kW to satisfy all system requirements: heating, cooling and DHW production. The power range is made up of the following sizes: 4, 6, 8, 10, 12 and 16 kW. Cascade Thanks to the new operating logics it is possible to install up to 6 units in cascade. By exploiting the modularity and redundancy of the generators, the system efficiently satisfies the requests of all plants. Complete hydraulic equipment as standard High head circulation pump, flow switch, expansion vessel (8L), safety valve, pressure gauge and "Y" strainer Remote control panel Control of system functions, programming and parameter verification. Furthermore, the possibility of connection via Modbus allows integration with BM systems Operating range Wide operating range, with operating temperatures in heating up to 65 °C ErP Energy Labeling The labeling regulation (EU Regulation 2017/1369) requires the labeling of products according to a decreasing energy scale that goes from A+++ to D (in heating) and from A+ to F (in sanitary). All models of the range (4M-A / 6M-A / 8M-A / 10M-A / 12M-A / 12T-A / 16M-A / 16T-A) reach an efficiency equal to A+++ in low temperature heating Components Twin rotary DC inverter compressor Complete with internal thermal protection and crankcase heater, mounted on anti-vibration rubbers and wound on an insulating hood to reduce the transmission of noise and vibrations due to operation Water-refrigerant exchanger With brazed plates in AISI 316 steel with external anti-condensation insulation in expanded polypropylene and anti-freeze resistance to prevent the formation of ice in the exchanger Air-refrigerant exchanger Aluminum finned coil with hydrophilic treatment to facilitate the flow of condensate, mechanically expanded copper pipes with internal shaping to increase heat exchange. Furthermore, the optimized circuitry reduces the formation of ice in the coil during heat pump operation Fan directly coupled to the high efficiency brushless DC variable speed motor. The fan is installed on aerodynamic nozzles and safety grilles Refrigerant circuit Made of pickled copper, it includes the electronic expansion valve, drier filters, high and low pressure switches, pressure transducer, cycle inversion valves, liquid receiver and separator, refrigerant injection valve on the suction side Hydraulic circuit In addition to the brazed plate heat exchanger, the unit includes the high head circulator, the expansion tank, the safety valve, the flow switch, the pressure gauge, the air vent valve and the metal mesh Y strainer (assembly by the installer) Electrical panel Includes fuse protection of the main internal components; the terminal board is divided into a power section for unit power supply and a control terminal board for connecting auxiliary inputs and outputs and connection to the control panel Main features Baxi Auriga Maximum energy efficiency Monobloc system for the production of heating, cooling and DHW Wide operating range, with external air down to -25°C in heating, up to 43°C in cooling DHW system management: production up to 65°C, storage tank temperature management, DHW recirculation pump and solar thermal integration Suitable for integration with radiant terminals, fan coils and mixed systems Integrated management with various plant systems: boiler integration, solar integration, management of diverter valves and secondary circuit pump Intelligent defrosting thanks to simultaneous monitoring of room temperature, coolant temperature, product water temperature and operating regime Compressor with DC inverter technology with high modulation range Modbus network connection low GWP refrigerant R32 Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €4.399,00

  • immagine-1-baxi-pompa-di-calore-aria-acqua-monoblocco-inverter-baxi-auriga-10m-a-r-32-monofase-a7794573-con-pannello-di-comando-remoto-incluso-novita

    BAXI Air-Water Heat Pump Monoblock Inverter Baxi Auriga 10m-A R-32 Single-Phase A7794573 With Remote Control Panel Included - New

    ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS FIRST START UP INCLUDED! Technical features Model : Auriga 10M-A Product code : A7794573 Remote Control Panel A7799122 Heating with low temperature application External air temperature 7°C - 87% RH Water temperature 30/35°C Nonimal thermal power: 10.00 kW Absorbed electrical power: 2.02 kW COP: 4.95 External air temperature 7°C - 87% RH Water temperature 35°C Thermal power: 8.00 kW Absorbed electrical power: 2.62 kW COP: 3.05 Heating with medium temperature application External air temperature 7°C - 87% RH Water temperature 45°C Nonimal thermal power: 10.00 kW Absorbed electrical power: 2.67 kW COP: 3.75 External air temperature 7°C - 87% RH Water temperature 55°C Nonimal thermal power: 9.50 kW Absorbed electrical power: 3.06 kW COP: 3.10 Cooling External air temperature 35°C - Water temperature 18°C Normal cooling capacity: 9.90 kW Absorbed electrical power: 2.18 kW EER: 4.55 External air temperature 35°C - Water temperature 7°C Normal cooling capacity: 8.20 kW Absorbed electrical power: 2.52 kW EER: 3.25 Energy efficiency Seasonal low-temperature space heating energy efficiency : 205% Seasonal space heating energy efficiency at medium temperature : 137% Low temperature seasonal energy efficiency class: A+++ Seasonal energy efficiency class at medium temperature: A++ Performance Exchanger water flow rate: 1.73 m 3 /h Available pump head: 70 kPa Sound power level : 60 dB(A) Sound pressure level : 50.5 dB(A) Electrical data Power supply (V,Hz, Ø) : 220~240/50/1 Refrigerant gas : R32 Operating limits Heating External air temperature : -25°C ~ 35°C Introduced water temperature : 12°C~ 65°C Cooling down External air temperature : -5°C ~ 43°C Introduced water temperature : 5°C ~ 25°C Installation data Plumbing pipe diameter: 1'' 1/4 Dimensions and weight Dimensions (HxWxD): 865x1385x488 mm Empty weight: 121 Kg BAXI AURIGA Inverter Monobloc Air-Water Heat Pumps introducing the new Auriga . The range is characterized by the ease and simplicity of installation, as well as for reliability and excellent performance . Furthermore, the high head of the circulator, fitted as STANDARD inside the unit, allows installation in large-sized systems, to cover greater distances from the boiler room or to install the unit directly at the service of the fan coils. The range expands and consists of well 8 models from 4 to 16 kW, single-phase and three-phase versions Wide range of powers from 4 to 16 kW to satisfy all system requirements: heating, cooling and DHW production. The power range is made up of the following sizes: 4, 6, 8, 10, 12 and 16 kW. Cascade Thanks to the new operating logics it is possible to install up to 6 units in cascade. By exploiting the modularity and redundancy of the generators, the system efficiently satisfies the requests of all plants. Complete hydraulic equipment as standard High head circulation pump, flow switch, expansion vessel (8L), safety valve, pressure gauge and "Y" strainer Remote control panel Control of system functions, programming and parameter verification. Furthermore, the possibility of connection via Modbus allows integration with BM systems Operating range Wide operating range, with operating temperatures in heating up to 65 °C ErP Energy Labeling The labeling regulation (EU Regulation 2017/1369) requires the labeling of products according to a decreasing energy scale that goes from A+++ to D (in heating) and from A+ to F (in sanitary). All models of the range (4M-A / 6M-A / 8M-A / 10M-A / 12M-A / 12T-A / 16M-A / 16T-A) reach an efficiency equal to A+++ in low temperature heating Components Twin rotary DC inverter compressor Complete with internal thermal protection and crankcase heater, mounted on anti-vibration rubbers and wound on an insulating hood to reduce the transmission of noise and vibrations due to operation Water-refrigerant exchanger With brazed plates in AISI 316 steel with external anti-condensation insulation in expanded polypropylene and anti-freeze resistance to prevent the formation of ice in the exchanger Air-refrigerant exchanger Aluminum finned coil with hydrophilic treatment to facilitate the flow of condensate, mechanically expanded copper pipes with internal shaping to increase heat exchange. Furthermore, the optimized circuitry reduces the formation of ice in the coil during heat pump operation Fan directly coupled to the high efficiency brushless DC variable speed motor. The fan is installed on aerodynamic nozzles and safety grilles Refrigerant circuit Made of pickled copper, it includes the electronic expansion valve, drier filters, high and low pressure switches, pressure transducer, cycle inversion valves, liquid receiver and separator, refrigerant injection valve on the suction side Hydraulic circuit In addition to the brazed plate heat exchanger, the unit includes the high head circulator, the expansion tank, the safety valve, the flow switch, the pressure gauge, the air vent valve and the metal mesh Y strainer (assembly by the installer) Electrical panel Includes fuse protection of the main internal components; the terminal board is divided into a power section for unit power supply and a control terminal board for connecting auxiliary inputs and outputs and connection to the control panel Main features Baxi Auriga Maximum energy efficiency Monobloc system for the production of heating, cooling and DHW Wide operating range, with external air down to -25°C in heating, up to 43°C in cooling DHW system management: production up to 65°C, storage tank temperature management, DHW recirculation pump and solar thermal integration Suitable for integration with radiant terminals, fan coils and mixed systems Integrated management with various plant systems: boiler integration, solar integration, management of diverter valves and secondary circuit pump Intelligent defrosting thanks to simultaneous monitoring of room temperature, coolant temperature, product water temperature and operating regime Compressor with DC inverter technology with high modulation range Modbus network connection low GWP refrigerant R32 Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €4.085,00

  • immagine-1-ferroli-pompa-di-calore-ibrida-ariaacqua-ferroli-omnia-s-hybrid-c-10-kw-per-installazione-splittata-con-produzione-sanitaria-istantanea-comando-incluso-a-bordo-macchina

    Ferroli Ferroli Omnia S Hybrid C 10 Kw Air/Water Hybrid Heat Pump For Split Installation With Instantaneous DHW Production Control Included On Board Machine

    Ferroli Omnia S Hybrid C 10 kW Air/Water Hybrid Heat Pump for split installation with instantaneous domestic hot water production control included on board the machine ERP class in heating A+++ SCOP (low temperature 35°C) W/W 5.21 SEER (water produced 7°C) W/W 5.83 Power supply V-ph-Hz 220/240-1-50 Type and no. compressors - 1 x Twin Rotary DC Type of exchanger plant side / source side - brazed stainless steel plates / finned coil Nominal thermal power kW 10.0 Heating max / min heat input (Hs) kW 27.2 / 3.2 Max / min heat output heating (80/60°C) kW 24 / 2.8 Heating max / min heat output (50/30°C) kW 26 / 3.1 Max / min DHW heat output (Hi) kW 28.5 / 2.9 Max / min DHW thermal power kW 28.0 / 2.8 Efficiency Pmax / Pmin (80-60°C) (Hi) % 98.1 / 98 Efficiency Pmax / Pmin (50-30°C) (Hi) % 106.1 / 107.5 Efficiency 30% (Hi) % 109.7 Max / min heating pressure bar 3 / 0.8 Max / min DHW operating pressure bar 9 / 0.3 Sanitary flow rate ?t 25°C / 30°C l/min 16.1 / 13.4 Omnia S Hybrid C > GENERAL FEATURES: The OMNIA S HYBRID C 3.2 hybrid heat pumps integrate the technology of the ecological R32 heat pump and the condensing boiler with instantaneous domestic hot water production in a single compact product. The R32 ecological gas manages to combine high efficiency with a reduced environmental impact. Thanks to its GWP of 675, about a third of the GWP of R410a, it helps to reduce CO2 equivalent emissions, the main causes of global warming. Ferroli Hybrid systems represent the ideal solution for replacing old generators, even on high temperature systems with radiators, thanks to the integration of the boiler. The compact dimensions similar to those of a wall-mounted boiler make it easy to replace without significant loss of space or heavy renovations. The internal electronics, by activating the boiler or the heat pump as the climatic conditions vary, optimizes the performance of the system always working in the most economical and efficient way possible, with great advantages for the user. The boiler will be free to produce instantaneous domestic hot water even during heating or cooling operation of the heat pump, maximizing comfort levels. Furthermore, in the unlikely event there is a blockage of the heat pump, the boiler will be able to operate in autonomous backup, guaranteeing heating and domestic hot water. The system consists of a Full Inverter DC outdoor unit, available in 4 power sizes, associated with a hybrid and condensing indoor unit with integrated hydronic module, complete with DC Inverter pump for managing the cooling circuit. The system is extremely versatile, able to work in harsh climatic conditions down to -20°C outside, avoiding the risk of freezing thanks to the split refrigeration circuit. Wall-mounted smoke outlet in the cases provided for by Legislative Decree 4 July 2014, n. 102. > OUTDOOR UNIT FEATURES: - Approved for outdoor operation in a completely uncovered place - Powered by R32 ecological gas with low environmental impact - Inrush current and reduced noise thanks to Full Inverter technology - Compressor with twin rotary type DC INVERTER motor on anti-vibration supports and wrapped in a double layer of sound-absorbing material to reduce vibrations and noise to a minimum - Axial fans with brushless DC motor complete with protection grilles - External air temperature probe already installed on the unit. > INDOOR UNIT FEATURES: - Robust and also suitable for replacements in particularly critical systems - Combustion module with 1:10 modulation and thick stainless steel heat exchanger with increased passages able to maintain high efficiency even on old systems with oxidations and dirt - Supplied as standard with system delivery and return angle valves (with inspectable filter) - MGR: Natural gas, LPG, Propane air Ready, with a simple configuration of the indoor unit is capable to operate on methane, LPG and propane air without the use of additional kits - MC2 : Multi Combustion Control, combustion system with patented gas-adaptive technology for a better adaptability of use to varying conditions of the gas network (e.g. fluctuations or reduced pressures) - FPS: Smoke Protection System. The standard fume clapet valve allows easy connection to systems pressurized smoke collectives - Particularly suitable for operation in flues that require ducting "heavy" thanks to the approval for operation with 50mm diameter flue pipes - Place of installation: also for outdoors in a partially protected place up to -5°C as standard. > THE CONTROL SYSTEM - The interface is equipped with Capsense technology with a 2.8" graphic display, which allows the user to interact with the product in a simple and practical way. The interface on the machine communicates easily with the new systems intelligent Connect CRP, which can manage up to 8 thermostats (of which 7 Connect CRP Zones) subdivided in 2 zones, one direct and one mixed. - MODBUS PROTOCOL for intelligent management via any external BMS - HEATING AND COOLING with Full Inverter modulation by Ferroli which allows the setting of climatic curves to improve consumption and user comfort. - SMART GRID INPUT FROM PHOTOVOLTAIC AND NETWORK Smart Grid contacts for optimizing consumption and bill costs. For details, please read the manuals - REMOTE CONTROL VIA APP. Optional with the Connect CRP, available for iOS and Android - PDC SILENT MODE. Reduces the maximum frequency of the compressor and the speed of the fan, so to significantly reduce noise. - ON/OFF and SUMMER/WINTER from external contacts. The unit can be turned on and off via a contact external, also receiving the summer/winter switching signals (for example from the zone thermostat). The operation will follow the controller settings - ECHO. Dedicated setpoint for “Eco” operation. Settable with daily time band - WEEKLY TIME PROGRAMMING. The Connect CRP (optional) allows differentiated time programming for each day of the week by defining the mode (COOL/HOT/DHW) and work setpoints for each band.

    €5.240,00

  • immagine-1-baxi-pompa-di-calore-aria-acqua-monoblocco-inverter-baxi-auriga-6m-a-r-32-monofase-a7794571-con-pannello-di-comando-remoto-incluso-novita

    BAXI Air-Water Heat Pump Monoblock Inverter Baxi Auriga 6m-A R-32 Single-Phase A7794571 With Remote Control Panel Included - New

    ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS FIRST START UP INCLUDED! Technical features Model : Auriga 6M-A Product code : A7794571 Remote Control Panel A7799122 Heating with low temperature application External air temperature 7°C - 87% RH Water temperature 30/35°C Nonimal thermal power: 6.35 kW Absorbed electrical power: 1.28 kW COP: 4.95 External air temperature 7°C - 87% RH Water temperature 35°C Normal thermal power: 6.00 kW Absorbed electrical power: 2.00 kW COP : 3.00 Heating with medium temperature application External air temperature 7°C - 87% RH Water temperature 45°C Nonimal thermal power: 6.30 kW Absorbed electrical power: 1.70 kW COP: 3.70 External air temperature 7°C - 87% RH Water temperature 55°C Nonimal thermal power: 6.00 kW Absorbed electrical power: 2.03 kW COP : 2.95 Cooling External air temperature 35°C - Water temperature 18°C Nonimal cooling capacity: 6.50 kW Absorbed electrical power: 1.35 kW EER: 4.80 External air temperature 35°C - Water temperature 7°C Nonimal cooling capacity: 7.00 kW Absorbed electrical power: 2.33 kW EER: 3.00 Energy efficiency Seasonal low-temperature space heating energy efficiency : 195% Seasonal space heating energy efficiency at medium temperature : 138% Low temperature seasonal energy efficiency class: A+++ Seasonal energy efficiency class at medium temperature: A++ Performance Exchanger water flow rate: 1.10 m 3 /h Available pump head: 83 kPa Sound power level : 58 dB(A) Sound pressure level : 47.5 dB(A) Electrical data Power supply (V,Hz, Ø) : 220~240/50/1 Refrigerant gas : R32 Operating limits Heating External air temperature : -25°C ~ 35°C Introduced water temperature : 12°C~ 65°C Cooling down External air temperature : -5°C ~ 43°C Introduced water temperature : 5°C ~ 25°C Installation data Hydraulic Pipe Diameter: 1" Dimensions and weight Dimensions (HxWxD): 718x1295x401 mm Empty weight : 98 Kg BAXI AURIGA Inverter Monobloc Air-Water Heat Pumps introducing the new Auriga . The range is characterized by the ease and simplicity of installation, as well as for reliability and excellent performance . Furthermore, the high head of the circulator, fitted as STANDARD inside the unit, allows installation in large-sized systems, to cover greater distances from the boiler room or to install the unit directly at the service of the fan coils. The range expands and consists of well 8 models from 4 to 16 kW, single-phase and three-phase versions Wide range of powers from 4 to 16 kW to satisfy all system requirements: heating, cooling and DHW production. The power range is made up of the following sizes: 4, 6, 8, 10, 12 and 16 kW. Cascade Thanks to the new operating logics it is possible to install up to 6 units in cascade. By exploiting the modularity and redundancy of the generators, the system efficiently satisfies the requests of all plants. Complete hydraulic equipment as standard High head circulation pump, flow switch, expansion vessel (8L), safety valve, pressure gauge and "Y" strainer Remote control panel Control of system functions, programming and parameter verification. Furthermore, the possibility of connection via Modbus allows integration with BM systems Operating range Wide operating range, with operating temperatures in heating up to 65 °C ErP Energy Labeling The labeling regulation (EU Regulation 2017/1369) requires the labeling of products according to a decreasing energy scale that goes from A+++ to D (in heating) and from A+ to F (in sanitary). All models of the range (4M-A / 6M-A / 8M-A / 10M-A / 12M-A / 12T-A / 16M-A / 16T-A) reach an efficiency equal to A+++ in low temperature heating Components Twin rotary DC inverter compressor Complete with internal thermal protection and crankcase heater, mounted on anti-vibration rubbers and wound on an insulating hood to reduce the transmission of noise and vibrations due to operation Water-refrigerant exchanger With brazed plates in AISI 316 steel with external anti-condensation insulation in expanded polypropylene and anti-freeze resistance to prevent the formation of ice in the exchanger Air-refrigerant exchanger Aluminum finned coil with hydrophilic treatment to facilitate the flow of condensate, mechanically expanded copper pipes with internal shaping to increase heat exchange. Furthermore, the optimized circuitry reduces the formation of ice in the coil during heat pump operation Fan directly coupled to the high efficiency brushless DC variable speed motor. The fan is installed on aerodynamic nozzles and safety grilles Refrigerant circuit Made of pickled copper, it includes the electronic expansion valve, drier filters, high and low pressure switches, pressure transducer, cycle inversion valves, liquid receiver and separator, refrigerant injection valve on the suction side Hydraulic circuit In addition to the brazed plate heat exchanger, the unit includes the high head circulator, the expansion tank, the safety valve, the flow switch, the pressure gauge, the air vent valve and the metal mesh Y strainer (assembly by the installer) Electrical panel Includes fuse protection of the main internal components; the terminal board is divided into a power section for unit power supply and a control terminal board for connecting auxiliary inputs and outputs and connection to the control panel Main features Baxi Auriga Maximum energy efficiency Monobloc system for the production of heating, cooling and DHW Wide operating range, with external air down to -25°C in heating, up to 43°C in cooling DHW system management: production up to 65°C, storage tank temperature management, DHW recirculation pump and solar thermal integration Suitable for integration with radiant terminals, fan coils and mixed systems Integrated management with various plant systems: boiler integration, solar integration, management of diverter valves and secondary circuit pump Intelligent defrosting thanks to simultaneous monitoring of room temperature, coolant temperature, product water temperature and operating regime Compressor with DC inverter technology with high modulation range Modbus network connection low GWP refrigerant R32 Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €3.000,00


You have seen 48 out of 206 products

Recently viewed products

Login

Forgot your password?

Don't have an account yet?
Create account