icon Boiler Sime Praktica 30 He Condensing Low Nox Smoke Kit Free Methane - New Erp | CaldaieMurali

Boiler Sime Praktica 30 He Condensing Low Nox Smoke Kit Free Methane - New Erp

Description

Sime Praktica 30 HE condensing boiler Low NOx flue gas kit methane - New ErP


  • Nominal thermal power (80-60°C) kW 23.7
  • Nominal thermal power (50-30°C) kW 25.7
  • Reduced thermal power G20 (80-60°C) kW 4.5
  • Reduced thermal power G20 (50-30°C) kW 5.1
  • Reduced thermal power G31 (80-60°C) kW 4.5
  • Reduced thermal power G31 (50-30°C) kW 5.1
  • Nominal heat input in heating kW 24
  • DHW nominal heat input kW 30
  • Reduced heat input G20/G31 kW 4.8
  • Useful efficiency min/max (80-60°C) %94.3/98.7
  • Useful efficiency min/max (50-30°C) % 105.5/107.1
  • Useful efficiency 30% of the load (40-30°C) % 108.5
  • Yield min. of combustion in situ (Presidential Decree 311) % 92.74

ELECTRICAL DATA

  • Power supply voltage/frequency V/Hz 230/50
  • Electric absorbed power max W 73
  • Electric power absorbed min W 54
  • Electrical power absorbed by the system pump W 41
  • Shutdown losses at 50°C (EN 15502) W 120
  • Electrical protection degree IP X5D
ENERGY PERFORMANCE
  • Seasonal heating energy efficiency class. TO
  • Seasonal heating energy efficiency %93
  • Heating sound power dB (A) 58
  • Sanitary energy efficiency class A
  • Sanitary energy efficiency % 84
  • Declared load health profile XL
HEATING PERFORMANCE
  • Heating adjustment range °C 20/80
  • Boiler water content 5.10 l
  • Max working pressure bar 3
  • Max operating temperature °C 85
  • Expansion vessel capacity l 9
HEALTHCARE PERFORMANCE
  • Nominal heat input kW 30
    Reduced heat input G20/G31 kW 4.8
    DHW adjustment range °C 10/60
    Specific sanitary flow rate (EN 13203) l/min 13.5
    Continuous DHW flow (∆t 25/35°C) l/min 16.7/11.9
    DHW flow rate min l/min 2
    Sanitary pressure min/max bar 0.5/7.0

Dimensions

  • HxWxD mm 702x400x250

PRAKTICA

Premixed condensing gas wall mounted boiler for heating only and instantaneous hot water production

  • Installation type: B23P-B33P-B53P-C13-C33-C43-C53-C63-C83-C93
  • NOx emission class 6 (EN 15502-1:2015)
  • Microprocessor electronic card with automatic adjustment of ignition power and maximum heating
  • Automatic ignition with flame ionization control
  • Degree of electrical protection to water IP X5D
  • Primary water/fume coil exchanger in AISI 316L stainless steel
  • Sanitary plate heat exchanger in stainless steel
  • Heating system expansion tank
  • Motorized diverter valve
  • Retroactive combustion control with electronic gas valve
  • Fume evacuation fan with electronic speed variation
  • High efficiency system pump with low energy consumption (ErP)
  • By-pass which ensures the circulation of water in the boiler when taps and thermostatic valves are used in the system
  • Safety thermostat against overheating of the primary exchanger
  • Smoke overheating probe
  • 3 bar system safety valve
  • Anti-blocking function of the pump and the diverter valve which activates automatically every 24 hours if there have been no requests for heat
  • Antifreeze function which activates automatically if the water temperature in the boiler falls below the value set at
  • parameter “tS 1.0” and, in the presence of an external probe, if the external temperature drops below the value set in parameter “tS 1.1”
  • Chimney sweep function which lasts 15 minutes and facilitates the task of qualified personnel for measuring parameters and combustion efficiency
  • Control panel equipped with display with numerical code self-diagnosis
  • Knobs for adjusting the heating and domestic hot water temperatures
  • Arrangement for SIME HOME remote control connection (optional)
  • Protection of hydraulic fittings to be placed under the boiler cod. 8094530 (optional)
  • Suitable for operation in a partially protected place according to EN 15502, with a maximum ambient temperature of 60°C and a minimum of -5°C
  • Integrated climatic regulation
  • Manual system loading device and water pressure control manometer
  • Pressure transducer which blocks the boiler in case of water shortage
  • Connections to the system in brass (DIN)

Product Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

Boiler Sime Praktica 30 He Condensing Low Nox Smoke Kit Free Methane - New Erp

Product form

Sime Praktica 30 HE condensing boiler Low NOx flue gas kit methane - New ErP Nominal thermal power (80-60°C) kW... Read more

€917,00 Incl. VAT

    Description

    Sime Praktica 30 HE condensing boiler Low NOx flue gas kit methane - New ErP


    • Nominal thermal power (80-60°C) kW 23.7
    • Nominal thermal power (50-30°C) kW 25.7
    • Reduced thermal power G20 (80-60°C) kW 4.5
    • Reduced thermal power G20 (50-30°C) kW 5.1
    • Reduced thermal power G31 (80-60°C) kW 4.5
    • Reduced thermal power G31 (50-30°C) kW 5.1
    • Nominal heat input in heating kW 24
    • DHW nominal heat input kW 30
    • Reduced heat input G20/G31 kW 4.8
    • Useful efficiency min/max (80-60°C) %94.3/98.7
    • Useful efficiency min/max (50-30°C) % 105.5/107.1
    • Useful efficiency 30% of the load (40-30°C) % 108.5
    • Yield min. of combustion in situ (Presidential Decree 311) % 92.74

    ELECTRICAL DATA

    • Power supply voltage/frequency V/Hz 230/50
    • Electric absorbed power max W 73
    • Electric power absorbed min W 54
    • Electrical power absorbed by the system pump W 41
    • Shutdown losses at 50°C (EN 15502) W 120
    • Electrical protection degree IP X5D
    ENERGY PERFORMANCE
    • Seasonal heating energy efficiency class. TO
    • Seasonal heating energy efficiency %93
    • Heating sound power dB (A) 58
    • Sanitary energy efficiency class A
    • Sanitary energy efficiency % 84
    • Declared load health profile XL
    HEATING PERFORMANCE
    • Heating adjustment range °C 20/80
    • Boiler water content 5.10 l
    • Max working pressure bar 3
    • Max operating temperature °C 85
    • Expansion vessel capacity l 9
    HEALTHCARE PERFORMANCE
    • Nominal heat input kW 30
      Reduced heat input G20/G31 kW 4.8
      DHW adjustment range °C 10/60
      Specific sanitary flow rate (EN 13203) l/min 13.5
      Continuous DHW flow (∆t 25/35°C) l/min 16.7/11.9
      DHW flow rate min l/min 2
      Sanitary pressure min/max bar 0.5/7.0

    Dimensions

    • HxWxD mm 702x400x250

    PRAKTICA

    Premixed condensing gas wall mounted boiler for heating only and instantaneous hot water production

    • Installation type: B23P-B33P-B53P-C13-C33-C43-C53-C63-C83-C93
    • NOx emission class 6 (EN 15502-1:2015)
    • Microprocessor electronic card with automatic adjustment of ignition power and maximum heating
    • Automatic ignition with flame ionization control
    • Degree of electrical protection to water IP X5D
    • Primary water/fume coil exchanger in AISI 316L stainless steel
    • Sanitary plate heat exchanger in stainless steel
    • Heating system expansion tank
    • Motorized diverter valve
    • Retroactive combustion control with electronic gas valve
    • Fume evacuation fan with electronic speed variation
    • High efficiency system pump with low energy consumption (ErP)
    • By-pass which ensures the circulation of water in the boiler when taps and thermostatic valves are used in the system
    • Safety thermostat against overheating of the primary exchanger
    • Smoke overheating probe
    • 3 bar system safety valve
    • Anti-blocking function of the pump and the diverter valve which activates automatically every 24 hours if there have been no requests for heat
    • Antifreeze function which activates automatically if the water temperature in the boiler falls below the value set at
    • parameter “tS 1.0” and, in the presence of an external probe, if the external temperature drops below the value set in parameter “tS 1.1”
    • Chimney sweep function which lasts 15 minutes and facilitates the task of qualified personnel for measuring parameters and combustion efficiency
    • Control panel equipped with display with numerical code self-diagnosis
    • Knobs for adjusting the heating and domestic hot water temperatures
    • Arrangement for SIME HOME remote control connection (optional)
    • Protection of hydraulic fittings to be placed under the boiler cod. 8094530 (optional)
    • Suitable for operation in a partially protected place according to EN 15502, with a maximum ambient temperature of 60°C and a minimum of -5°C
    • Integrated climatic regulation
    • Manual system loading device and water pressure control manometer
    • Pressure transducer which blocks the boiler in case of water shortage
    • Connections to the system in brass (DIN)

    Product Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    Data sheetData sheet
    • peso: 40.0 kg
    • classe energetica produzione acs: A
    • classe energetica riscaldamento: A
    • gas: Methane
    • marca: Syme
    • metri quadri : 150
    • modello: 8115006
    • potenza in kw: 25
    • potenza nominale: 25
    • superficie riscaldabile mq: 150
    Shipping detailsShipping details

    The order is processed according to the payment method chosen:

    for payments by CREDIT CARD, PAYPAL, MARK, the order is processed the same day. Orders placed before 2.00 pm will be managed on the same day. The BRT or GLS courier will collect the ordered goods from our warehouses the following morning.

    Subsequently, the courier assigns the shipment number (tracking number) and communicates the same to the customer via e-mail, allowing him to follow the delivery status and estimated times in real time on the brt.it or gls-grop.com website. 24-72 the courier will deliver the goods (excluding islands and disadvantaged areas) to the address indicated by the Customer at the time of order confirmation. Transport costs are charged to the customer and are calculated taking into account the volume and/or weight of the ordered item/s. However, product delivery times vary according to the requested item, payment methods and the delivery times chosen by the Customer, which is why the times indicated are merely indicative and cannot be considered binding for Decidiprezzo srl. Orders placed online are delivered throughout Italy, with the exception of Livigno, Campione d'Italia, Vatican City and the Republic of San Marino. In some periods of the year (summer period / Christmas period) the processing times could undergo changes compared to the standard ones declared above.

    NB: In the periods of July and August due to the high amount of orders, delivery times could be delayed

    Icon for coinShipping cost

    Shipping costs vary according to the weight of the order.

    Consult the tables with the weights for Italy and for the smaller islands and disadvantaged areas.

    Warranty detailsWarranty details

    Pursuant to art. 63 of the Consumer Code, the risk of loss and damage to the goods, for reasons not attributable to the seller, is transferred to the consumer when the latter, or a third party designated by him and other than the carrier, physically comes into possession of goods. However, the risk is transferred to the consumer as soon as the goods are delivered to the carrier. The Customer who at the time of purchase has decided to make use of the extra insurance service for the transport of the purchased goods, in the event that he finds anomalies at the time of delivery (packaging damaged or otherwise altered in the closing seals, damaged product or scratched, missing one or more packages ordered), must accept the product by writing on the document provided by the carrier: "WE ACCEPT WITH RESERVE" + description of the anomaly found. In fact, to enforce the insurance coverage it is not sufficient to note "ACCEPTED WITH RESERVE" or "ACCEPTED WITH SUBJECT TO INSPECTION", BUT the reason for the reservation must be explained in detail. If the package or the product should show visible damage, scratches or any other type of anomaly and the courier should refuse to affix a specific reserve, the goods must be refused and the incident reported immediately (and in any case in a timely manner) to the Customer Service of Decidiprice srl. In any case, without prejudice to the seller's obligations in terms of legal guarantee pursuant to articles 128 et seq. of the Consumer Code, Decidiprezzo srl will not be held responsible for any anomalies found in the state of the product, after delivery, if the Customer, in the presence of an anomaly, has accepted the package without making a specific reservation (in the corrected above). Any damage or anomalies must be reported to Customer Service by email to postvendita@climaconvenienza.it. The request must be forwarded no later than 8 calendar days from receipt of the goods. Any notification beyond the aforementioned terms will not be taken into consideration.

    Customer service detailsCustomer service details

    Our customer service department is dedicated to providing support to our customers with any problems or questions they may have before or after purchasing our products.

    Use the direct communication channel to speak to one of our operators, or send us an email to one of the addresses listed on the contact us page.

    Our customer service team is made up of highly trained professionals who are always ready to help customers solve any problem or answer any question quickly and efficiently. We are committed to ensuring maximum customer satisfaction and providing the highest quality after-sales service. So if you need any assistance, don't hesitate to contact us; we will be happy to help you in any way we can.

    Recensioni di CaldaieMurali.it

    Latest Products Viewed

    Login

    Forgot your password?

    Don't have an account yet?
    Create account