icon Savio Evodens Max E 35s* Gas ​​Condensing Boiler With Kettle Complete With LPG Fume Exhaust Kit - New Erp | CaldaieMurali

Savio Evodens Max E 35s* Gas ​​Condensing Boiler With Kettle Complete With LPG Fume Exhaust Kit - New Erp

Description

Overview

SAVIO EVOdens MAX E 35S* CONDENSING BOILER WITH TANK COMPLETE WITH LPG LPG FUME EXHAUST KIT - NEW ErP

Technical specifications

Model:ÿEVODENS MAX

LPG code: 103041007300

LPG code: 103141006300

Characteristics of heating/sanitary exercises:

Heating/sanitary nominal heat inputkWÿ30.0 / 34.0

Heating/sanitary maximum useful powerkWÿ29.5 / 33.4

Yield name 60ø/80øC %ÿ98.2

Yield min. 60ø/80øC %ÿ97.6

Yield at 30% of the %102.1ÿ load

Energy efficiencynø

Minimum / maximum heating temperature**øC 25 / 85

Sanitary minimum / maximum pressurebar 0.3 / 3.0

Sanitary expansion vessel capacity (total) l 2.0

Boiler nominal capacity l 45

Boiler useful capacity l 41

Maximum flow rate (T=25 K) / (T=35 K) l/minÿ20.8 / 13.6

Voltage / Power at nominal heat input V ~ / W 230 ~ / 112

Power at minimum thermal capacity W 10

Power at rest (stand-by) W 5

Degrees of protection nø IPX4D

Boiler water content 3.5 l

Dimensions HxWxD:ÿ900x600x400; 70.5

Characteristics

EVO DENS MAX E

The EVODENS MAX E boilers with porcelain-glass storage tank were designed to satisfy the most demanding users: large and immediate production of domestic hot water despite being a boiler of contained dimensions. The storage tank, together with the latest generation primary condensing exchanger, ensure continuous supply of domestic water in service at the desired temperature. For this reason, EVODENS MAX E boilers are the ideal solution for the comfort of the whole family.

Features:ÿ

High yields (in compliance with yield directive 92/42 EEC and Legislative Decree 311/06)

Sanitary comfort( EN 13203)

Primary and condensing exchanger in stainless steel with plastic coatings to offer maximum resistance to corrosion

Total premix burner, built in stainless steel (ClassÿNOx 5)

High efficiency pump with low energy consumption, ErP Ready

Maximum power adjustable according to the needs of the system

Glass-porcelain steel boiler with convenient inspection and cleaning flange

Magnesium anodal dismountable

External insulation of the boiler in polyurethane foam

Two-litre sanitary expansion tanks, as standard

Degrees of protection IPX5D

Installability in a partially protected place

Integration with Savio solar systems, using a solar kit

Innovative digital control panel with graphical interface and keys

Digital pressure reading by pressure transducer

Arrangement for external probe remote control

Possibility of managing a zone valve by means of a remote control in the case of multi-zone systems

Four-controllers

Summer / winter / off selector

Heating temperature regulator

DHW temperature regulator

Digital pressure reading

DHW and heating temperature visualization from the display

Fault diagnostics display, fault history block status

View recommended fills fill guide

View months left until annual maintenance is due

External temperature display (with external probe connected) and signaling of external probe connected and ÿK value set

Flame modulation display

Visualization of SaviSOLCONTROL solar control unit connected to EVODENS MAX E, active solar pump and solar integration

Sanitary comfort function selectable via dedicated key

Ingressdirectal INFO menu dedicated to the user

STANDARD:

Boiler support bracket and paper template

Boiler power cable

Condensate collection siphon

Quick instruction to the user

OPTIONALS:

Paper template

remote control

External probe kit

Tap kit (system boiler connection pipes, gas and sanitary water taps and quick couplings)

Ecodesign directive: from 2015 on new condensing boilers

In fact, after very long negotiations, the ÿEcodesign regulationÿ was approved, which introduces a new energy labeling on minimum efficiency standards for boilers.ÿIn particular, an energy classification from A+ to G is envisaged for space heating appliances and from A to G for appliances for the production of domestic hot water. ÿHence the obligation to installÿonly condensing boilers, heat generators capable of recovering a large part of the latent heat contained in the fumes which, otherwise, would be dispersed in the chimneyÿas occurs in traditional boilers. The recovered heat is transferred to the heating system, making it possible to achieve a yield of 106% with 92% of the traditional boiler and 84/85% of an oldÿÿtraditional generator.ÿThe installation obligation concerns manufacturers of boilers which will no longer be able to place on the market non-condensing starting from 26 September 2015. This means that starting from this date, anyone who wants to install a boiler in their own home will have to install only condensing models. Only one particular type of non-condensing boiler will continue to be produced which is technically called open room? to be installedÿ when it is not possible to replace an old boiler with a condensing boilerÿdue to problems related to the collective flueÿof some multi-family buildings.

Products for heating water and the environment represent around 30% of the world's energy consumption in Europe.ÿ

Designing eco-friendly products and promoting high performance technologies to end users in 2020 will lead to:

An annual energy saving equivalent to 56 million tons of oil, quantifiable to the savings obtained if the water and environmental heating systems of two large nations like Italy were deactivated.

As of 26 September 2015, the ErP regulation and ÿenergy labelingÿwill be applied in Europe to water and space heating products (boilers, heat pumps, micro-CHP devices, water heaters, and hot water storage tanks) u.

How to read energy labels

There are different labels, based on the type and function of the product (only room water heating of both, and in this case the label must bear both classifications).

In addition to the energy class, the label provides other information that could be useful for understanding which product has the least environmental impact (for example power and consumption in different climatic zones, noise levels, etc.).

It is possible to increase the energy efficiency of hot water production and space heating by connecting several products and accessories in one system. In this case it is necessary to prepare a system label in addition to that relating to the single product

Warranty

All products for sale on our site are new and packed. The guarantee on this article is 24 months from the date of purchase.

Shipping

From the day payment is received, the product will be shipped within 3 working days. Free insured shipping for Italy. Shipping will take place via one of the national carriers

Savio Evodens Max E 35s* Gas ​​Condensing Boiler With Kettle Complete With LPG Fume Exhaust Kit - New Erp

Product form

Overview SAVIO EVOdens MAX E 35S* CONDENSING BOILER WITH TANK COMPLETE WITH LPG LPG FUME EXHAUST KIT - NEW ErP... Read more

€1.847,00 Incl. VAT

    Description

    Overview

    SAVIO EVOdens MAX E 35S* CONDENSING BOILER WITH TANK COMPLETE WITH LPG LPG FUME EXHAUST KIT - NEW ErP

    Technical specifications

    Model:ÿEVODENS MAX

    LPG code: 103041007300

    LPG code: 103141006300

    Characteristics of heating/sanitary exercises:

    Heating/sanitary nominal heat inputkWÿ30.0 / 34.0

    Heating/sanitary maximum useful powerkWÿ29.5 / 33.4

    Yield name 60ø/80øC %ÿ98.2

    Yield min. 60ø/80øC %ÿ97.6

    Yield at 30% of the %102.1ÿ load

    Energy efficiencynø

    Minimum / maximum heating temperature**øC 25 / 85

    Sanitary minimum / maximum pressurebar 0.3 / 3.0

    Sanitary expansion vessel capacity (total) l 2.0

    Boiler nominal capacity l 45

    Boiler useful capacity l 41

    Maximum flow rate (T=25 K) / (T=35 K) l/minÿ20.8 / 13.6

    Voltage / Power at nominal heat input V ~ / W 230 ~ / 112

    Power at minimum thermal capacity W 10

    Power at rest (stand-by) W 5

    Degrees of protection nø IPX4D

    Boiler water content 3.5 l

    Dimensions HxWxD:ÿ900x600x400; 70.5

    Characteristics

    EVO DENS MAX E

    The EVODENS MAX E boilers with porcelain-glass storage tank were designed to satisfy the most demanding users: large and immediate production of domestic hot water despite being a boiler of contained dimensions. The storage tank, together with the latest generation primary condensing exchanger, ensure continuous supply of domestic water in service at the desired temperature. For this reason, EVODENS MAX E boilers are the ideal solution for the comfort of the whole family.

    Features:ÿ

    High yields (in compliance with yield directive 92/42 EEC and Legislative Decree 311/06)

    Sanitary comfort( EN 13203)

    Primary and condensing exchanger in stainless steel with plastic coatings to offer maximum resistance to corrosion

    Total premix burner, built in stainless steel (ClassÿNOx 5)

    High efficiency pump with low energy consumption, ErP Ready

    Maximum power adjustable according to the needs of the system

    Glass-porcelain steel boiler with convenient inspection and cleaning flange

    Magnesium anodal dismountable

    External insulation of the boiler in polyurethane foam

    Two-litre sanitary expansion tanks, as standard

    Degrees of protection IPX5D

    Installability in a partially protected place

    Integration with Savio solar systems, using a solar kit

    Innovative digital control panel with graphical interface and keys

    Digital pressure reading by pressure transducer

    Arrangement for external probe remote control

    Possibility of managing a zone valve by means of a remote control in the case of multi-zone systems

    Four-controllers

    Summer / winter / off selector

    Heating temperature regulator

    DHW temperature regulator

    Digital pressure reading

    DHW and heating temperature visualization from the display

    Fault diagnostics display, fault history block status

    View recommended fills fill guide

    View months left until annual maintenance is due

    External temperature display (with external probe connected) and signaling of external probe connected and ÿK value set

    Flame modulation display

    Visualization of SaviSOLCONTROL solar control unit connected to EVODENS MAX E, active solar pump and solar integration

    Sanitary comfort function selectable via dedicated key

    Ingressdirectal INFO menu dedicated to the user

    STANDARD:

    Boiler support bracket and paper template

    Boiler power cable

    Condensate collection siphon

    Quick instruction to the user

    OPTIONALS:

    Paper template

    remote control

    External probe kit

    Tap kit (system boiler connection pipes, gas and sanitary water taps and quick couplings)

    Ecodesign directive: from 2015 on new condensing boilers

    In fact, after very long negotiations, the ÿEcodesign regulationÿ was approved, which introduces a new energy labeling on minimum efficiency standards for boilers.ÿIn particular, an energy classification from A+ to G is envisaged for space heating appliances and from A to G for appliances for the production of domestic hot water. ÿHence the obligation to installÿonly condensing boilers, heat generators capable of recovering a large part of the latent heat contained in the fumes which, otherwise, would be dispersed in the chimneyÿas occurs in traditional boilers. The recovered heat is transferred to the heating system, making it possible to achieve a yield of 106% with 92% of the traditional boiler and 84/85% of an oldÿÿtraditional generator.ÿThe installation obligation concerns manufacturers of boilers which will no longer be able to place on the market non-condensing starting from 26 September 2015. This means that starting from this date, anyone who wants to install a boiler in their own home will have to install only condensing models. Only one particular type of non-condensing boiler will continue to be produced which is technically called open room? to be installedÿ when it is not possible to replace an old boiler with a condensing boilerÿdue to problems related to the collective flueÿof some multi-family buildings.

    Products for heating water and the environment represent around 30% of the world's energy consumption in Europe.ÿ

    Designing eco-friendly products and promoting high performance technologies to end users in 2020 will lead to:

    An annual energy saving equivalent to 56 million tons of oil, quantifiable to the savings obtained if the water and environmental heating systems of two large nations like Italy were deactivated.

    As of 26 September 2015, the ErP regulation and ÿenergy labelingÿwill be applied in Europe to water and space heating products (boilers, heat pumps, micro-CHP devices, water heaters, and hot water storage tanks) u.

    How to read energy labels

    There are different labels, based on the type and function of the product (only room water heating of both, and in this case the label must bear both classifications).

    In addition to the energy class, the label provides other information that could be useful for understanding which product has the least environmental impact (for example power and consumption in different climatic zones, noise levels, etc.).

    It is possible to increase the energy efficiency of hot water production and space heating by connecting several products and accessories in one system. In this case it is necessary to prepare a system label in addition to that relating to the single product

    Warranty

    All products for sale on our site are new and packed. The guarantee on this article is 24 months from the date of purchase.

    Shipping

    From the day payment is received, the product will be shipped within 3 working days. Free insured shipping for Italy. Shipping will take place via one of the national carriers

    Data sheetData sheet
    • peso: 70.0 kg
    • classe energetica produzione acs: A
    • classe energetica riscaldamento: A
    • gas: LPG
    • marca: Wise
    • metri quadri : 250
    • modello: EVODENS MAX E 35S GPL
    • potenza in kw: 35
    • potenza nominale: 35
    • superficie riscaldabile mq: 250
    Icon for coinShipping cost

    Shipping costs vary according to the weight of the order.

    Consult the tables with the weights for Italy and for the smaller islands and disadvantaged areas.

    Warranty detailsWarranty details

    Pursuant to art. 63 of the Consumer Code, the risk of loss and damage to the goods, for reasons not attributable to the seller, is transferred to the consumer when the latter, or a third party designated by him and other than the carrier, physically comes into possession of goods. However, the risk is transferred to the consumer as soon as the goods are delivered to the carrier. The Customer who at the time of purchase has decided to make use of the extra insurance service for the transport of the purchased goods, in the event that he finds anomalies at the time of delivery (packaging damaged or otherwise altered in the closing seals, damaged product or scratched, missing one or more packages ordered), must accept the product by writing on the document provided by the carrier: "WE ACCEPT WITH RESERVE" + description of the anomaly found. In fact, to enforce the insurance coverage it is not sufficient to note "ACCEPTED WITH RESERVE" or "ACCEPTED WITH SUBJECT TO INSPECTION", BUT the reason for the reservation must be explained in detail. If the package or the product should show visible damage, scratches or any other type of anomaly and the courier should refuse to affix a specific reserve, the goods must be refused and the incident reported immediately (and in any case in a timely manner) to the Customer Service of Decidiprice srl. In any case, without prejudice to the seller's obligations in terms of legal guarantee pursuant to articles 128 et seq. of the Consumer Code, Decidiprezzo srl will not be held responsible for any anomalies found in the state of the product, after delivery, if the Customer, in the presence of an anomaly, has accepted the package without making a specific reservation (in the corrected above). Any damage or anomalies must be reported to Customer Service by email to postvendita@climaconvenienza.it. The request must be forwarded no later than 8 calendar days from receipt of the goods. Any notification beyond the aforementioned terms will not be taken into consideration.

    Customer service detailsCustomer service details

    Our customer service department is dedicated to providing support to our customers with any problems or questions they may have before or after purchasing our products.

    Use the direct communication channel to speak to one of our operators, or send us an email to one of the addresses listed on the contact us page.

    Our customer service team is made up of highly trained professionals who are always ready to help customers solve any problem or answer any question quickly and efficiently. We are committed to ensuring maximum customer satisfaction and providing the highest quality after-sales service. So if you need any assistance, don't hesitate to contact us; we will be happy to help you in any way we can.

    Reviews of CaldaieMurali.it

    feedaty-widget

    Latest Products Viewed

    Login

    Forgot your password?

    Don't have an account yet?
    Create account