FONDITAL DELFIS KC 28 METHANE CONDENSING BOILER COMPLETE WITH FUME EXHAUST KIT - NEW ErP 2016: Wall-mounted pre-mixing condensing boiler with instantaneous production of domestic hot water, sealed chamber.

Technical specifications

Characteristics of heating/sanitary exercises:

Forced draft sealed chamber

Nominal heat input: 26.4 kW

Rated heat output: 27.9 kW

Efficiency at maximum power: 96.4%

Efficiency 30% of load: 105.4%

Classification according to 92/42/EEC: ****

NOx class (EN 297/EN 483); 5

DHW production t 30øC: 15.0 l/min

Sanitary pressure min-max: 0.5 - 6ÿbar

Domestic hot water/heating maximum temperature: 62/83øC

Expansion tank capacity: 9 l

Heating consumption nominal power Metanm3/h 2.79

Sanitary consumption rated power Metanm3/h 3.22

Total absorbed electric power: 84 W

Degrees of protection of the quadrielectric:ÿIPX4D

Dimensions (hxlxp)ÿ700x400x250ÿmmÿ; 33.5kg

METHANE power supply

Warranty: 2 years

Heating energy efficiency Class Aÿÿ

Sanitaryware energy efficiencyprofilXL Class A

Features list

DELPHIS KC

Wall-hung condensing premixing boiler with sealed chamber, with instantaneous production of domestic hot water

The boiler, unlike the storage ones, allows instantaneous production of domestic hot water and uses condensing technology which allows a reduction in consumption, as well as low emissions of pollutants.

Plus:ÿ

Ultra compact

Modulation ratio 1:9

User interface with LCD

Boiler room temperature adjustment with external probe

Supplementary relay for the management of 2 heating zones

9 liter expansion tanks

Boiler change kit

Features:ÿ

Heat exchanger in thermopolymers and stainless steel

Total premix burner

Modulating gas valve with constant ratio/gas

Combustion fan with variable speed

Classification of performance according to 92/42/EEC:

NOx emission class (EN 297): 5

3-speed circulator with built-in deaerator

Availability of the boiler change kit as accessories

Modulation wide range 1:9

Electronic ignition, ionization flame detection

NTC temperature probes on the sanitary on the heating

LCD interface with diagnostics

Sanitary plate heat exchanger in stainless steel

Motorized diverter valve

Bypass

Connection preparation:ÿ

External probe

2 ambient probes

CommandRemotOpen Therm

Zone heating management card for high and low temperatures

WHAT IS THE REGULATION? ERP

A concrete help for our planet.ÿThe application of the Ecodesign and Ecolabeling regulations

The European Union, as a result of the values ​​expressed by the Kyoto Protocol, sets itself an ambitious goal, known as the Pianeurope20, 20, 20 climate-energy goal.

By 2020 the intention is to reduce greenhouse gas emissions by 20%, as well as energy consumption and to make sure that 20% of Europe's total energy demand comes from renewable energy sources.

The energy consumed by buildings is estimated to be around 40% of total energy consumption. Of which 80% used for heating and domestic hot water:

Heating67%

Lighting and appliances 15%

Hot water 14%

kitchen 4%

All combined heating only boilers must be equipped with High Efficiency circulators.

Heating appliances without high-efficiency circulation pumps cannot be placed on the market after 1 August 2015.

From 1 August 2015, high-efficiency circulation pumps may still be placed on the market.

Starting fromÿ26 September 2015ÿall heat generators for space heating, appliances for the production of DHW and systems consisting of several of these appliances, with a Pn 400 kW for eco-design and with a Pn 70 kW for labelling, in order to be placed on the market, they must comply with the regulations issued by the European Union, indicated with the term ErP - Energy Related Products.

The introduction of the ÿEcodesign Directiveÿ of 26 September 2015 also entails the ban on the placing on the market of almost all traditional atmospheric boilers

The ErPÿ label for space heaters highlights the respective energy class on a scale from ÿA ++ÿ to Gÿ (for heat pumps up to D, while for accumulators from A to G). Starting from August 2019 a further restriction of the class will be applied, namely A +++ to D, for accumulators from A + to G, while for heat pumps (at low temperature) the label must carry information on the climatic zone.

Fondital supplies all products subject to this standard with a label and a technical data sheet that distributors, retailers and specialized installers must use to define the products. Official labeling can only take place from 26 September 2015.

PRODUCT LABEL

In the product energy label, information on the efficiency characteristics is reported:

I. brand name of the supplier

II. model identifier

III. reference to space heating and domestic hot water functions

IV. efficiency class

V. nominal heat output of the appliances

YOU. sound power level in dB (sol heat pumps)

VII. possible operation during dead hours (only heat pumps)

The label is made available by Fondital and it is the responsibility of the distributors to make it clearly visible on each device at the point of sale, (soled only after 26 September 2015).

SYSTEM LABEL

All the combinations of appliances that will be installed, called systems, must also be subject to the energy classification through the system label.

For example, a condensing boiler and a solar panel connected to a storage tank are considered a system subject to EcLabelling. The sameÿ system, composed of the previous components, accompanied in addition by a regulation device such as a chronothermostat, must be added to the system as it can improve the energy classification to be declared on the label.

The calculation of the energy efficiency of the system must be provided by filling in a data sheet prescribed by the EC regulations and called a fiche.

The energy classification of a system can be defined both by the manufacturer of the various components (e.g. pacchetticompletSulpack Easy) and by an installer retailer who builds a system with components supplied by different manufacturers.

In the latter case, the installing retailer will have to rely on the generator label and on the information given in the technical data sheets supplied by the manufacturers of the individual generators and components to calculate the energy class of the system.

Warranty

All products for sale on our site are new and packed. The guarantee on this article is 24 months from the date of purchase.

Gas Boiler Fondital Delfis Kc 28 Methane Condensing Complete Kit For Flue - New Erp

Product form

Overview FONDITAL DELFIS KC 28 METHANE CONDENSING BOILER COMPLETE WITH FUME EXHAUST KIT - NEW ErP 2016: Wall-mounted pre-mixing condensing... Read more

€862,00 Incl. VAT

    Description

    Overview

    FONDITAL DELFIS KC 28 METHANE CONDENSING BOILER COMPLETE WITH FUME EXHAUST KIT - NEW ErP 2016: Wall-mounted pre-mixing condensing boiler with instantaneous production of domestic hot water, sealed chamber.

    Technical specifications

    Characteristics of heating/sanitary exercises:

    Forced draft sealed chamber

    Nominal heat input: 26.4 kW

    Rated heat output: 27.9 kW

    Efficiency at maximum power: 96.4%

    Efficiency 30% of load: 105.4%

    Classification according to 92/42/EEC: ****

    NOx class (EN 297/EN 483); 5

    DHW production t 30øC: 15.0 l/min

    Sanitary pressure min-max: 0.5 - 6ÿbar

    Domestic hot water/heating maximum temperature: 62/83øC

    Expansion tank capacity: 9 l

    Heating consumption nominal power Metanm3/h 2.79

    Sanitary consumption rated power Metanm3/h 3.22

    Total absorbed electric power: 84 W

    Degrees of protection of the quadrielectric:ÿIPX4D

    Dimensions (hxlxp)ÿ700x400x250ÿmmÿ; 33.5kg

    METHANE power supply

    Warranty: 2 years

    Heating energy efficiency Class Aÿÿ

    Sanitaryware energy efficiencyprofilXL Class A

    Features list

    DELPHIS KC

    Wall-hung condensing premixing boiler with sealed chamber, with instantaneous production of domestic hot water

    The boiler, unlike the storage ones, allows instantaneous production of domestic hot water and uses condensing technology which allows a reduction in consumption, as well as low emissions of pollutants.

    Plus:ÿ

    Ultra compact

    Modulation ratio 1:9

    User interface with LCD

    Boiler room temperature adjustment with external probe

    Supplementary relay for the management of 2 heating zones

    9 liter expansion tanks

    Boiler change kit

    Features:ÿ

    Heat exchanger in thermopolymers and stainless steel

    Total premix burner

    Modulating gas valve with constant ratio/gas

    Combustion fan with variable speed

    Classification of performance according to 92/42/EEC:

    NOx emission class (EN 297): 5

    3-speed circulator with built-in deaerator

    Availability of the boiler change kit as accessories

    Modulation wide range 1:9

    Electronic ignition, ionization flame detection

    NTC temperature probes on the sanitary on the heating

    LCD interface with diagnostics

    Sanitary plate heat exchanger in stainless steel

    Motorized diverter valve

    Bypass

    Connection preparation:ÿ

    External probe

    2 ambient probes

    CommandRemotOpen Therm

    Zone heating management card for high and low temperatures

    WHAT IS THE REGULATION? ERP

    A concrete help for our planet.ÿThe application of the Ecodesign and Ecolabeling regulations

    The European Union, as a result of the values ​​expressed by the Kyoto Protocol, sets itself an ambitious goal, known as the Pianeurope20, 20, 20 climate-energy goal.

    By 2020 the intention is to reduce greenhouse gas emissions by 20%, as well as energy consumption and to make sure that 20% of Europe's total energy demand comes from renewable energy sources.

    The energy consumed by buildings is estimated to be around 40% of total energy consumption. Of which 80% used for heating and domestic hot water:

    Heating67%

    Lighting and appliances 15%

    Hot water 14%

    kitchen 4%

    All combined heating only boilers must be equipped with High Efficiency circulators.

    Heating appliances without high-efficiency circulation pumps cannot be placed on the market after 1 August 2015.

    From 1 August 2015, high-efficiency circulation pumps may still be placed on the market.

    Starting fromÿ26 September 2015ÿall heat generators for space heating, appliances for the production of DHW and systems consisting of several of these appliances, with a Pn 400 kW for eco-design and with a Pn 70 kW for labelling, in order to be placed on the market, they must comply with the regulations issued by the European Union, indicated with the term ErP - Energy Related Products.

    The introduction of the ÿEcodesign Directiveÿ of 26 September 2015 also entails the ban on the placing on the market of almost all traditional atmospheric boilers

    The ErPÿ label for space heaters highlights the respective energy class on a scale from ÿA ++ÿ to Gÿ (for heat pumps up to D, while for accumulators from A to G). Starting from August 2019 a further restriction of the class will be applied, namely A +++ to D, for accumulators from A + to G, while for heat pumps (at low temperature) the label must carry information on the climatic zone.

    Fondital supplies all products subject to this standard with a label and a technical data sheet that distributors, retailers and specialized installers must use to define the products. Official labeling can only take place from 26 September 2015.

    PRODUCT LABEL

    In the product energy label, information on the efficiency characteristics is reported:

    I. brand name of the supplier

    II. model identifier

    III. reference to space heating and domestic hot water functions

    IV. efficiency class

    V. nominal heat output of the appliances

    YOU. sound power level in dB (sol heat pumps)

    VII. possible operation during dead hours (only heat pumps)

    The label is made available by Fondital and it is the responsibility of the distributors to make it clearly visible on each device at the point of sale, (soled only after 26 September 2015).

    SYSTEM LABEL

    All the combinations of appliances that will be installed, called systems, must also be subject to the energy classification through the system label.

    For example, a condensing boiler and a solar panel connected to a storage tank are considered a system subject to EcLabelling. The sameÿ system, composed of the previous components, accompanied in addition by a regulation device such as a chronothermostat, must be added to the system as it can improve the energy classification to be declared on the label.

    The calculation of the energy efficiency of the system must be provided by filling in a data sheet prescribed by the EC regulations and called a fiche.

    The energy classification of a system can be defined both by the manufacturer of the various components (e.g. pacchetticompletSulpack Easy) and by an installer retailer who builds a system with components supplied by different manufacturers.

    In the latter case, the installing retailer will have to rely on the generator label and on the information given in the technical data sheets supplied by the manufacturers of the individual generators and components to calculate the energy class of the system.

    Warranty

    All products for sale on our site are new and packed. The guarantee on this article is 24 months from the date of purchase.

    Data sheetData sheet
    • peso: 40.0 kg
    • marca: FONDITAL
    • modello: CALD_332
    Icon for coinShipping cost

    Shipping costs vary according to the weight of the order.

    Consult the tables with the weights for Italy and for the smaller islands and disadvantaged areas.

    Warranty detailsWarranty details

    Pursuant to art. 63 of the Consumer Code, the risk of loss and damage to the goods, for reasons not attributable to the seller, is transferred to the consumer when the latter, or a third party designated by him and other than the carrier, physically comes into possession of goods. However, the risk is transferred to the consumer as soon as the goods are delivered to the carrier. The Customer who at the time of purchase has decided to make use of the extra insurance service for the transport of the purchased goods, in the event that he finds anomalies at the time of delivery (packaging damaged or otherwise altered in the closing seals, damaged product or scratched, missing one or more packages ordered), must accept the product by writing on the document provided by the carrier: "WE ACCEPT WITH RESERVE" + description of the anomaly found. In fact, to enforce the insurance coverage it is not sufficient to note "ACCEPTED WITH RESERVE" or "ACCEPTED WITH SUBJECT TO INSPECTION", BUT the reason for the reservation must be explained in detail. If the package or the product should show visible damage, scratches or any other type of anomaly and the courier should refuse to affix a specific reserve, the goods must be refused and the incident reported immediately (and in any case in a timely manner) to the Customer Service of Decidiprice srl. In any case, without prejudice to the seller's obligations in terms of legal guarantee pursuant to articles 128 et seq. of the Consumer Code, Decidiprezzo srl will not be held responsible for any anomalies found in the state of the product, after delivery, if the Customer, in the presence of an anomaly, has accepted the package without making a specific reservation (in the corrected above). Any damage or anomalies must be reported to Customer Service by email to postvendita@climaconvenienza.it. The request must be forwarded no later than 8 calendar days from receipt of the goods. Any notification beyond the aforementioned terms will not be taken into consideration.

    Customer service detailsCustomer service details

    Our customer service department is dedicated to providing support to our customers with any problems or questions they may have before or after purchasing our products.

    Use the direct communication channel to speak to one of our operators, or send us an email to one of the addresses listed on the contact us page.

    Our customer service team is made up of highly trained professionals who are always ready to help customers solve any problem or answer any question quickly and efficiently. We are committed to ensuring maximum customer satisfaction and providing the highest quality after-sales service. So if you need any assistance, don't hesitate to contact us; we will be happy to help you in any way we can.

    Reviews of CaldaieMurali.it

    feedaty-widget

    Latest Products Viewed

    Login

    Forgot your password?

    Don't have an account yet?
    Create account