icon Ferroli Omnia M 3.2 14 Kw 2cp000if Three-Phase Reversible Heat Pump For Outdoor Installation With R-32 Dc Inverter Compressor Wi-Fi With Control Included | CaldaieMurali

Ferroli Omnia M 3.2 14 Kw 2cp000if Three-Phase Reversible Heat Pump For Outdoor Installation With R-32 Dc Inverter Compressor Wi-Fi With Control Included

Description

ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS
 
FREE FIRST START-UP
Technical features
  • Model : OMNIA M 3.2 14-T
  • Product code : 2CP000IF
  • Command included

Energy efficiency

  • Energy class in heating at 35° C: A+++
  • Energy class in heating at 55° C: A+++
  • SCOP heating with water set at 35 °C : 4.72
  • SCOP heating with water set at 45 °C : 3.47
  • SEER cooling with water set at 7 °C: 4.83
  • SEER cooling with water set at 18 °C: 6.85
Performance
 
Heating
  • Useful power in heating with water set at 35° C: 14.5 kW
  • Useful power in heating with water set at 45° C: 14.1 kW
  • Useful power in heating with water set at 55° C: 13.8 kW
  • Absorbed power with water set at 35° C: 3.15 kW
  • Absorbed power with water set at 45° C: 3.92 kW
  • Absorbed power with water set at 55° C: 4.68 kW
  • Water flow rate with water set at 35° C : 2494 l/h
  • Water flow rate with water set at 45° C : 2425 l/h
  • Water flow rate with water set at 55° C : 1484 l/h
Cooling down
  • Useful power in cooling with water set at 7 °C: 12.4 kW
  • Useful power in cooling with water set at 18 °C: 12.9 kW
  • Absorbed power with water set at 7° C: 4.96 kW
  • Absorbed power with water set at 18° C: 3.49 kW
  • Water flow rate with water set at 7° C : 2133 l/h
  • Water flow rate with water set at 18° C : 2219 l/h
Technical data
  • Compressor type : Twin Rotary DC
  • Number of compressors : 1
  • Number of cooling circuits: 1
  • Type of fans : DC axial
  • Number of fans : 1
  • Expansion vessel volume: 5 litres
  • Water safety valve setting: 3 bar
  • Minimum system water content: 25 litres
  • Sound power level in heating : 56 ~ 65 dB(A)
  • Sound power level in cooling : 56 ~ 65 dB(A)

Electrical data

  • Power supply (V,Hz, Ø) : 380~415/50/3
  • Refrigerant gas : R32
  • Maximum absorbed current: 11A
Installation data
  • Delivery pipe diameter: 1 ¼” M
  • Return pipe diameter: 1 ¼” M

Dimensions and weight

  • Dimensions (WxHxD): 1385x865x526 mm
  • Weight : 144Kg

5 years without worries

5 Year Warranty

Ferroli OMNIA M 3.2 Reversible heat pumps for outdoor installation with DC inverter compressor

A heat pump with silent and ecological efficiency

This series of air-to-water heat pumps with low environmental impact ecological gas R32 satisfies the winter and summer air conditioning needs of residential and commercial systems of small and medium power. All the units are suitable for outdoor installation and being able to produce water up to 65°C they can be used in radiant systems, fan coils, radiators and for the indirect production of DHW domestic hot water via an optional external boiler

The units are characterized by the use of a DC inverter compressor which allows the power supplied to be modulated and are complete with a hydronic kit made up of all the essential components for quick and safe installation. The units are characterized by high energy efficiency and low sound levels which allow them to be used as a single generator serving the system or integrated with other energy sources such as electric support heaters or boilers

All units are supplied as standard with a DHW tank water temperature probe and with an external air temperature probe, already installed on the unit, to carry out climatic regulation in heating and cooling. All units are carefully built and individually tested in the factory. The installation requires only the electrical and hydraulic connections. In a system it is possible to connect a maximum of 6 units in cascade; one of them will be “MASTER” while the others will be “SLAVE” units.

Refrigerant circuit

Contained inside the unit to facilitate maintenance operations, it is equipped with a compressor with a Twin rotary type DC Inverter motor to guarantee greater dynamic balancing and reduce vibrations. It is placed on rubber anti-vibration mounts and wrapped in a double layer of sound-absorbing material to reduce noise. The compressor is also equipped with a crankcase oil heater. The circuit is completed by a brazed stainless steel plate heat exchanger complete with antifreeze heater, axial fans with brushless DC motor complete with safety grilles, finned coil with anti-corrosion treatment made up of copper pipes and aluminum fins. All units are equipped with variable speed control of the fans which allows operation with low outside temperatures in cooling and high outside temperatures in heating

Hydraulic circuit

Contained inside the unit to facilitate maintenance operations, it is equipped as standard with a low-consumption circulator with brushless DC motor, water flow switch, automatic air vent, water pressure gauge, expansion tank, safety valve, Y-shaped water filter The plate heat exchanger and all the hydraulic circuit pipes are thermally insulated to prevent the formation of condensate and reduce heat loss

Air source The benefits offered by this technology

Aerothermal energy is the energy of the future. Ferroli aerothermal heat pumps use clean technology capable of obtaining up to 79% of the energy supplied for home comfort from the outside air. Ferroli aerothermal heat pumps are designed to provide cooling in summer, heating in winter and/or domestic hot water throughout the year. These latest generation heat pumps with inverter technology and the use of an ecological gas such as R32 do not produce heat from the combustion of a fuel but, simply with minimal energy consumption, exploit the energy in the air and transfer it to the inside the house

AIR HEATING

Greater efficiency

The OMNIA M 3.2 monobloc range has energy class A++ for the production of water at 55ºC and A+++ for the water produced at 35°C

Compact outdoor unit. More space available

Thanks to the adoption of a compact and small-sized unit, especially for the more powerful models, OMNIA M 3.2 can be easily placed outside the house, guaranteeing more available space inside

Quick and easy installation

Being a packaged unit, installation costs and times are significantly reduced. The interconnection of the refrigerant between the units is not necessary, as the entire refrigerant circuit is contained in the equipment, it is not even necessary to make a connection to bring the fuel, nor to create a flue gas evacuation duct. In addition, the device includes all the plumbing elements necessary for correct and quick connection to the plumbing and DHW heating system.

Ideal combination with low temperature systems

The OMNIA M 3.2 range can be easily installed in combination with low temperature systems, connecting fan coils, radiators, underfloor heating, to obtain maximum energy efficiency and maximum domestic comfort

Easy integration with an existing boiler

OMNIA M 3.2 can be combined and integrated with any boiler in the system. The control of the device, based on the external temperature and the required operating conditions, optimizes the production of heat for heating and DHW, using the device with the best efficiency

Production of hot water at 65°C with low external temperature

The OMNIA M 3.2 range is able to supply hot water at 60°C with an external temperature down to -15°C and at 40°C with an external temperature down to -25°C, without any type of support/accessory. With cold but positive temperatures OMNIA M 3.2 can produce hot water up to 65°C

Protection against freezing of hydraulic components without the need to add glycol

If low outside temperatures are detected, the circulation pump and the electric antifreeze heater of the plate heat exchanger are activated, thus preventing freezing of the hydraulic components. There is therefore no need to add glycol to the system


Control system Operating principle

The general control system allows monitoring of all the functions of the inverter system and of the correct functioning of the compressor. It also incorporates regulation algorithms using predefined climatic curves that can be selected by the customer, the management of a DHW circuit, the setting of time slots for noise reduction during the night, alarm signaling, pump block prevention and integration with external heat generators. The user interface consists of a wired remote controller which allows the management of:

Management of 2 distinct zones, direct + mixed The unit is able to manage the pumps of both zones and for the mixed in addition the mixing valve and water delivery temperature probe

Photovoltaic and Smart Grid management The management of a photovoltaic system and of the "intelligent grid" function is ensured by 2 digital inputs on the PCB with specific operating logics

Heating and cooling system The unit activates in hot or cold mode, works by modulating the frequency of the compressor to keep the water temperature produced at the setpoint value set via the controller

Domestic hot water production The unit activates in heating mode to maintain the temperature of a DHW tank at the set point value. A 3-way diverter valve is required (not supplied) and a temperature probe, supplied as standard, to be inserted in a well of the DHW boiler.

Additional energy sources These sources can be activated in Integration or replacement of the heat pump during heating service or for DHW production and in case the heat pump does not work.

Cascade management of several units Possibility of managing up to 6 units in cascade even with different powers with a single controller connected to the Master. In the event of an anomaly in one "Slave", the others can function normally

DHW tank electric resistance It is possible to manage a possible integration and/or reserve electric resistance and for the anti-legionella function

Fast DHW Function that can be activated manually which allows you to give priority to domestic hot water by bringing the DHW tank to the set point in the shortest possible time

Anti-legionella function Weekly anti-legionella cycles can be set. The heat pump must be integrated with a DHW boiler electric heater or boiler

Silenced mode 2 levels of silence are possible which, if active, according to an hourly programming, involve a reduction in the maximum frequency of the compressor and in the speed of the fan to reduce the noise emitted perhaps during the night and the power absorbed by the unit

ON/OFF The unit can be switched on and off via an external contact. It can be operated from the controller keyboard

Hot/Cold The unit can be switched on and off in cold and hot mode via 2 external contacts

ECO Possibility of defining time slots and related setpoint for ECO modes in hot and cold mode

Weekly programming Allows differentiated time programming for each day of the week by defining the working mode and setpoint for each band

Anti-freeze protection Guaranteed up to an external air temperature of -20°C thanks to the heat pump itself operating in hot mode, to the standard anti-freeze electrical resistance and to the electric booster if installed.

Remote control of the unit via APP Available for iOS and Android


Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

Ferroli Omnia M 3.2 14 Kw 2cp000if Three-Phase Reversible Heat Pump For Outdoor Installation With R-32 Dc Inverter Compressor Wi-Fi With Control Included

Product form

ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS  ... Read more

€4.246,00 Incl. VAT

    Description

    ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS
     
    FREE FIRST START-UP
    Technical features
    • Model : OMNIA M 3.2 14-T
    • Product code : 2CP000IF
    • Command included

    Energy efficiency

    • Energy class in heating at 35° C: A+++
    • Energy class in heating at 55° C: A+++
    • SCOP heating with water set at 35 °C : 4.72
    • SCOP heating with water set at 45 °C : 3.47
    • SEER cooling with water set at 7 °C: 4.83
    • SEER cooling with water set at 18 °C: 6.85
    Performance
     
    Heating
    • Useful power in heating with water set at 35° C: 14.5 kW
    • Useful power in heating with water set at 45° C: 14.1 kW
    • Useful power in heating with water set at 55° C: 13.8 kW
    • Absorbed power with water set at 35° C: 3.15 kW
    • Absorbed power with water set at 45° C: 3.92 kW
    • Absorbed power with water set at 55° C: 4.68 kW
    • Water flow rate with water set at 35° C : 2494 l/h
    • Water flow rate with water set at 45° C : 2425 l/h
    • Water flow rate with water set at 55° C : 1484 l/h
    Cooling down
    • Useful power in cooling with water set at 7 °C: 12.4 kW
    • Useful power in cooling with water set at 18 °C: 12.9 kW
    • Absorbed power with water set at 7° C: 4.96 kW
    • Absorbed power with water set at 18° C: 3.49 kW
    • Water flow rate with water set at 7° C : 2133 l/h
    • Water flow rate with water set at 18° C : 2219 l/h
    Technical data
    • Compressor type : Twin Rotary DC
    • Number of compressors : 1
    • Number of cooling circuits: 1
    • Type of fans : DC axial
    • Number of fans : 1
    • Expansion vessel volume: 5 litres
    • Water safety valve setting: 3 bar
    • Minimum system water content: 25 litres
    • Sound power level in heating : 56 ~ 65 dB(A)
    • Sound power level in cooling : 56 ~ 65 dB(A)

    Electrical data

    • Power supply (V,Hz, Ø) : 380~415/50/3
    • Refrigerant gas : R32
    • Maximum absorbed current: 11A
    Installation data
    • Delivery pipe diameter: 1 ¼” M
    • Return pipe diameter: 1 ¼” M

    Dimensions and weight

    • Dimensions (WxHxD): 1385x865x526 mm
    • Weight : 144Kg

    5 years without worries

    5 Year Warranty

    Ferroli OMNIA M 3.2 Reversible heat pumps for outdoor installation with DC inverter compressor

    A heat pump with silent and ecological efficiency

    This series of air-to-water heat pumps with low environmental impact ecological gas R32 satisfies the winter and summer air conditioning needs of residential and commercial systems of small and medium power. All the units are suitable for outdoor installation and being able to produce water up to 65°C they can be used in radiant systems, fan coils, radiators and for the indirect production of DHW domestic hot water via an optional external boiler

    The units are characterized by the use of a DC inverter compressor which allows the power supplied to be modulated and are complete with a hydronic kit made up of all the essential components for quick and safe installation. The units are characterized by high energy efficiency and low sound levels which allow them to be used as a single generator serving the system or integrated with other energy sources such as electric support heaters or boilers

    All units are supplied as standard with a DHW tank water temperature probe and with an external air temperature probe, already installed on the unit, to carry out climatic regulation in heating and cooling. All units are carefully built and individually tested in the factory. The installation requires only the electrical and hydraulic connections. In a system it is possible to connect a maximum of 6 units in cascade; one of them will be “MASTER” while the others will be “SLAVE” units.

    Refrigerant circuit

    Contained inside the unit to facilitate maintenance operations, it is equipped with a compressor with a Twin rotary type DC Inverter motor to guarantee greater dynamic balancing and reduce vibrations. It is placed on rubber anti-vibration mounts and wrapped in a double layer of sound-absorbing material to reduce noise. The compressor is also equipped with a crankcase oil heater. The circuit is completed by a brazed stainless steel plate heat exchanger complete with antifreeze heater, axial fans with brushless DC motor complete with safety grilles, finned coil with anti-corrosion treatment made up of copper pipes and aluminum fins. All units are equipped with variable speed control of the fans which allows operation with low outside temperatures in cooling and high outside temperatures in heating

    Hydraulic circuit

    Contained inside the unit to facilitate maintenance operations, it is equipped as standard with a low-consumption circulator with brushless DC motor, water flow switch, automatic air vent, water pressure gauge, expansion tank, safety valve, Y-shaped water filter The plate heat exchanger and all the hydraulic circuit pipes are thermally insulated to prevent the formation of condensate and reduce heat loss

    Air source The benefits offered by this technology

    Aerothermal energy is the energy of the future. Ferroli aerothermal heat pumps use clean technology capable of obtaining up to 79% of the energy supplied for home comfort from the outside air. Ferroli aerothermal heat pumps are designed to provide cooling in summer, heating in winter and/or domestic hot water throughout the year. These latest generation heat pumps with inverter technology and the use of an ecological gas such as R32 do not produce heat from the combustion of a fuel but, simply with minimal energy consumption, exploit the energy in the air and transfer it to the inside the house

    AIR HEATING

    Greater efficiency

    The OMNIA M 3.2 monobloc range has energy class A++ for the production of water at 55ºC and A+++ for the water produced at 35°C

    Compact outdoor unit. More space available

    Thanks to the adoption of a compact and small-sized unit, especially for the more powerful models, OMNIA M 3.2 can be easily placed outside the house, guaranteeing more available space inside

    Quick and easy installation

    Being a packaged unit, installation costs and times are significantly reduced. The interconnection of the refrigerant between the units is not necessary, as the entire refrigerant circuit is contained in the equipment, it is not even necessary to make a connection to bring the fuel, nor to create a flue gas evacuation duct. In addition, the device includes all the plumbing elements necessary for correct and quick connection to the plumbing and DHW heating system.

    Ideal combination with low temperature systems

    The OMNIA M 3.2 range can be easily installed in combination with low temperature systems, connecting fan coils, radiators, underfloor heating, to obtain maximum energy efficiency and maximum domestic comfort

    Easy integration with an existing boiler

    OMNIA M 3.2 can be combined and integrated with any boiler in the system. The control of the device, based on the external temperature and the required operating conditions, optimizes the production of heat for heating and DHW, using the device with the best efficiency

    Production of hot water at 65°C with low external temperature

    The OMNIA M 3.2 range is able to supply hot water at 60°C with an external temperature down to -15°C and at 40°C with an external temperature down to -25°C, without any type of support/accessory. With cold but positive temperatures OMNIA M 3.2 can produce hot water up to 65°C

    Protection against freezing of hydraulic components without the need to add glycol

    If low outside temperatures are detected, the circulation pump and the electric antifreeze heater of the plate heat exchanger are activated, thus preventing freezing of the hydraulic components. There is therefore no need to add glycol to the system


    Control system Operating principle

    The general control system allows monitoring of all the functions of the inverter system and of the correct functioning of the compressor. It also incorporates regulation algorithms using predefined climatic curves that can be selected by the customer, the management of a DHW circuit, the setting of time slots for noise reduction during the night, alarm signaling, pump block prevention and integration with external heat generators. The user interface consists of a wired remote controller which allows the management of:

    Management of 2 distinct zones, direct + mixed The unit is able to manage the pumps of both zones and for the mixed in addition the mixing valve and water delivery temperature probe

    Photovoltaic and Smart Grid management The management of a photovoltaic system and of the "intelligent grid" function is ensured by 2 digital inputs on the PCB with specific operating logics

    Heating and cooling system The unit activates in hot or cold mode, works by modulating the frequency of the compressor to keep the water temperature produced at the setpoint value set via the controller

    Domestic hot water production The unit activates in heating mode to maintain the temperature of a DHW tank at the set point value. A 3-way diverter valve is required (not supplied) and a temperature probe, supplied as standard, to be inserted in a well of the DHW boiler.

    Additional energy sources These sources can be activated in Integration or replacement of the heat pump during heating service or for DHW production and in case the heat pump does not work.

    Cascade management of several units Possibility of managing up to 6 units in cascade even with different powers with a single controller connected to the Master. In the event of an anomaly in one "Slave", the others can function normally

    DHW tank electric resistance It is possible to manage a possible integration and/or reserve electric resistance and for the anti-legionella function

    Fast DHW Function that can be activated manually which allows you to give priority to domestic hot water by bringing the DHW tank to the set point in the shortest possible time

    Anti-legionella function Weekly anti-legionella cycles can be set. The heat pump must be integrated with a DHW boiler electric heater or boiler

    Silenced mode 2 levels of silence are possible which, if active, according to an hourly programming, involve a reduction in the maximum frequency of the compressor and in the speed of the fan to reduce the noise emitted perhaps during the night and the power absorbed by the unit

    ON/OFF The unit can be switched on and off via an external contact. It can be operated from the controller keyboard

    Hot/Cold The unit can be switched on and off in cold and hot mode via 2 external contacts

    ECO Possibility of defining time slots and related setpoint for ECO modes in hot and cold mode

    Weekly programming Allows differentiated time programming for each day of the week by defining the working mode and setpoint for each band

    Anti-freeze protection Guaranteed up to an external air temperature of -20°C thanks to the heat pump itself operating in hot mode, to the standard anti-freeze electrical resistance and to the electric booster if installed.

    Remote control of the unit via APP Available for iOS and Android


    Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    Data sheetData sheet
    • peso: 199.0 kg
    • alimentazione: Three-phase
    • gas: R-32
    • marca: Ferroli
    • modello: OMNIA_M_14T_1
    • potenza in kw: 14
    • tipologia : Reversible
    Icon for coinShipping cost

    Shipping costs vary according to the weight of the order.

    Consult the tables with the weights for Italy and for the smaller islands and disadvantaged areas.

    Warranty detailsWarranty details

    Pursuant to art. 63 of the Consumer Code, the risk of loss and damage to the goods, for reasons not attributable to the seller, is transferred to the consumer when the latter, or a third party designated by him and other than the carrier, physically comes into possession of goods. However, the risk is transferred to the consumer as soon as the goods are delivered to the carrier. The Customer who at the time of purchase has decided to make use of the extra insurance service for the transport of the purchased goods, in the event that he finds anomalies at the time of delivery (packaging damaged or otherwise altered in the closing seals, damaged product or scratched, missing one or more packages ordered), must accept the product by writing on the document provided by the carrier: "WE ACCEPT WITH RESERVE" + description of the anomaly found. In fact, to enforce the insurance coverage it is not sufficient to note "ACCEPTED WITH RESERVE" or "ACCEPTED WITH SUBJECT TO INSPECTION", BUT the reason for the reservation must be explained in detail. If the package or the product should show visible damage, scratches or any other type of anomaly and the courier should refuse to affix a specific reserve, the goods must be refused and the incident reported immediately (and in any case in a timely manner) to the Customer Service of Decidiprice srl. In any case, without prejudice to the seller's obligations in terms of legal guarantee pursuant to articles 128 et seq. of the Consumer Code, Decidiprezzo srl will not be held responsible for any anomalies found in the state of the product, after delivery, if the Customer, in the presence of an anomaly, has accepted the package without making a specific reservation (in the corrected above). Any damage or anomalies must be reported to Customer Service by email to postvendita@climaconvenienza.it. The request must be forwarded no later than 8 calendar days from receipt of the goods. Any notification beyond the aforementioned terms will not be taken into consideration.

    Customer service detailsCustomer service details

    Our customer service department is dedicated to providing support to our customers with any problems or questions they may have before or after purchasing our products.

    Use the direct communication channel to speak to one of our operators, or send us an email to one of the addresses listed on the contact us page.

    Our customer service team is made up of highly trained professionals who are always ready to help customers solve any problem or answer any question quickly and efficiently. We are committed to ensuring maximum customer satisfaction and providing the highest quality after-sales service. So if you need any assistance, don't hesitate to contact us; we will be happy to help you in any way we can.

    Recensioni di CaldaieMurali.it

    feedaty-widget

    Latest Products Viewed

    Login

    Forgot your password?

    Don't have an account yet?
    Create account