icon Air-Water Reversible Heat Pump Inverter Ferroli Omnia S 3.2 06 R-32 With Control Included | CaldaieMurali

Air-Water Reversible Heat Pump Inverter Ferroli Omnia S 3.2 06 R-32 With Control Included

Description

ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS
 
FREE FIRST START-UP
Technical features
  • Model : OMNIA S 3.2 06
  • Product code : 0XHK6SWA
  • Command included

Optional accessories

  • Unpainted built-in cabinet 016092X0
  • Painted built-in cabinet 016093X0

Energy efficiency

  • Energy class in heating at 35° C: A+++
  • Energy class in heating at 55° C: A++
  • SCOP heating with water set at 35 °C: 4.95
  • SEER cooling with water set at 7 °C: 5.34
Performance
 
Heating
  • Useful power in heating with water set at 35° C: 6.35 kW
  • Useful power in heating with water set at 45° C: 6.30 kW
  • Useful power in heating with water set at 55° C: 6.00 kW
  • Absorbed power with water set at 35° C: 1.28 kW
  • Absorbed power with water set at 45° C: 1.70 kW
  • Absorbed power with water set at 55° C: 2.03 kW
  • Water flow rate with water set at 35° C : 1092 l/h
  • Water flow rate with water set at 45° C: 1084l/h
  • Water flow rate with water set at 55° C : 645 l/h
Cooling down
  • Useful power in cooling with water set at 7 °C: 6.50 kW
  • Useful power in cooling with water set at 18 °C: 6.50 kW
  • Absorbed power with water set at 7° C: 2.17 kW
  • Absorbed power with water set at 18° C: 1.35 kW
  • Water flow rate with water set at 7° C : 1118 l/h
  • Water flow rate with water set at 18° C : 1118 l/h
External unit technical data
  • Compressor type : Twin Rotary DC
  • Number of compressors : 1
  • Number of cooling circuits: 1
  • Type of fans : DC axial
  • Number of fans : 1
  • Sound power level in heating : 53 ~ 61 dB(A)
  • Sound power level in cooling : 54 ~ 61 dB(A)
  • Liquid piping diameter : 6.35 mm (1/4")
  • Gas pipe diameter: 15.88 (5/8")
  • Maximum piping length: 30 m
  • Maximum pipe height difference: 20 m

Indoor unit technical data

  • Exchanger type : Brazed stainless steel plates
  • Expansion vessel volume: 10 litres
  • Water safety valve setting: 3 bar
  • Minimum system water content: 40 litres
  • Sound power level : 42 dB(A)
  • System piping diameter: 1" gas F
  • DHW piping diameter: 3/4" gas F
  • Liquid pipe diameter : 9.52 mm (3/8")
  • Gas pipe diameter: 15.88 (5/8")

Electrical data

  • Power supply (V,Hz, Ø) : 220~240/50/1
  • Refrigerant gas : R32

Dimensions and weight

  • External unit dimensions (WxHxD): 1008x712x426 mm
  • Outdoor unit weight: 58.0 Kg
  • Internal unit dimensions (WxHxD): 422x702x320 mm

5 years without worries

5 Year Warranty

Ferroli OMNIA S 3.2 Reversible heat pumps for split installation with DC inverter compressor

Quietness, efficiency and design

OMNIA S 3.2 is the new range of split heat pumps Full Inverter R32 by Ferroli. The range includes an Outdoor Unit with the heart of the refrigerant circuit, from the compressor to the fan with the air side exchanger, which is connected to the refrigerant gas pipes towards the Indoor Unit. The Indoor Unit, on the other hand, contains the heart of the hydraulic circuit of the generator with all the main pre-installed components, such as the high-efficiency circulator and the expansion vessel, to safely allow quick and practical installation

The split installation of OMNIA S 3.2 , with only the gas pipes between the outdoor and indoor unit, is synonymous with security against any freezing problem, even at the coldest temperatures (down to -25°C) and in the absence of electricity. All units meet the most extreme winter and summer air conditioning requirements, they can in fact produce hot water up to 65°C , which makes them suitable for practically all heating systems, whether radiant, fan coil or radiator, including the production of domestic hot water (DHW), via an external boiler

The new conception Full Inverter by Ferroli uses DC inverter modulations on the 3 main energy-intensive components of the machine, i.e. compressor, fan and pump. This allows you to modulate the power supplied by finely tracking the thermal load and allowing the user very high efficiencies and important energy savings . Also, the concept Full Inverter by Ferroli guarantees sound levels among the lowest on the market, avoiding sudden changes in the network and guaranteeing a longer useful life for the components.

Indoor and outdoor unit of OMNIA 3.2

The Outdoor Unit contains the heart of the refrigerant circuit, while the Internal Unit the heart of the hydraulic circuit. They are connected to each other by pipes R32 ecological refrigerant gas , which has allowed us to combine high efficiency with a reduced environmental impact. Thanks to his GWP of 675 , about a third of the GWP of R410a, helps reduce CO2 equivalent emissions, the main causes of global warming

The heat pumps use the Outdoor Unit to extract heat from the air outside the home and convey it to the water in your system, via an exchanger in the Indoor Unit. That's exactly why they manage to get such high efficiencies , exploiting so renewable the energy already present in the air outside the home

The new conception Full Inverter by Ferroli then does the rest, tracking the thermal loads precisely and without waste (modulating the compressor, pump and fan), manages to achieve even greater efficiencies, guaranteeing important savings in bills , without stress on the components and with very low sound levels

OMNIA S 3.2 it can be used both as the sole generator of the system and integrated with other sources such as a Ferroli boiler

The control system

The user interface has been equipped with capsense technology with 2.8” graphic display, which allows the user to interact with the product easily and extremely simply

Omnia M control 3.2

Modbus protocol It can be interfaced to BMS/BACS automation and management systems

Heating and cooling Full Inverter modulation finely follows the desired setpoints, with the possibility of setting heating and cooling climatic curves, further optimizing consumption for the user

Domestic hot water production When the DHW temperature probe calls the machine, it automatically switches to the domestic hot water tank with dedicated DHW set point. 3-way diverter valve supplied as standard

Smart Grid input from photovoltaic and grid Digital Smart Grid inputs for the management of an input from the photovoltaic system and from the electricity grid. These allow you to optimize consumption and bill costs

DHW tank electrical resistance The DHW electrical integration serves as integration, anti-legionella or reserve source in the event of an anomaly

Fast DHW Priority to DHW production to bring the storage tank to the set point in the shortest possible time

Anti-legionella function Allows you to set anti-legionella weekly cycles

Silent mode Reduces the frequency of the compressor and the speed of the fan, so as to significantly reduce noise. Programmable on time slots

ON/OFF From external contact. Activation and deactivation via an external contact, for example from a zone thermostat

Hot / cold From external contacts. Summer/winter switching signal from outside, for example from the zone thermostat

ECO function Dedicated setpoint for " Eco " operation. Settable with daily time band

Anti-freeze protection Heat pump operation with circulator ON and possible electric booster


Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

Air-Water Reversible Heat Pump Inverter Ferroli Omnia S 3.2 06 R-32 With Control Included

Product form

ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS  ... Read more

€3.820,00 Incl. VAT

    Description

    ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS
     
    FREE FIRST START-UP
    Technical features
    • Model : OMNIA S 3.2 06
    • Product code : 0XHK6SWA
    • Command included

    Optional accessories

    • Unpainted built-in cabinet 016092X0
    • Painted built-in cabinet 016093X0

    Energy efficiency

    • Energy class in heating at 35° C: A+++
    • Energy class in heating at 55° C: A++
    • SCOP heating with water set at 35 °C: 4.95
    • SEER cooling with water set at 7 °C: 5.34
    Performance
     
    Heating
    • Useful power in heating with water set at 35° C: 6.35 kW
    • Useful power in heating with water set at 45° C: 6.30 kW
    • Useful power in heating with water set at 55° C: 6.00 kW
    • Absorbed power with water set at 35° C: 1.28 kW
    • Absorbed power with water set at 45° C: 1.70 kW
    • Absorbed power with water set at 55° C: 2.03 kW
    • Water flow rate with water set at 35° C : 1092 l/h
    • Water flow rate with water set at 45° C: 1084l/h
    • Water flow rate with water set at 55° C : 645 l/h
    Cooling down
    • Useful power in cooling with water set at 7 °C: 6.50 kW
    • Useful power in cooling with water set at 18 °C: 6.50 kW
    • Absorbed power with water set at 7° C: 2.17 kW
    • Absorbed power with water set at 18° C: 1.35 kW
    • Water flow rate with water set at 7° C : 1118 l/h
    • Water flow rate with water set at 18° C : 1118 l/h
    External unit technical data
    • Compressor type : Twin Rotary DC
    • Number of compressors : 1
    • Number of cooling circuits: 1
    • Type of fans : DC axial
    • Number of fans : 1
    • Sound power level in heating : 53 ~ 61 dB(A)
    • Sound power level in cooling : 54 ~ 61 dB(A)
    • Liquid piping diameter : 6.35 mm (1/4")
    • Gas pipe diameter: 15.88 (5/8")
    • Maximum piping length: 30 m
    • Maximum pipe height difference: 20 m

    Indoor unit technical data

    • Exchanger type : Brazed stainless steel plates
    • Expansion vessel volume: 10 litres
    • Water safety valve setting: 3 bar
    • Minimum system water content: 40 litres
    • Sound power level : 42 dB(A)
    • System piping diameter: 1" gas F
    • DHW piping diameter: 3/4" gas F
    • Liquid pipe diameter : 9.52 mm (3/8")
    • Gas pipe diameter: 15.88 (5/8")

    Electrical data

    • Power supply (V,Hz, Ø) : 220~240/50/1
    • Refrigerant gas : R32

    Dimensions and weight

    • External unit dimensions (WxHxD): 1008x712x426 mm
    • Outdoor unit weight: 58.0 Kg
    • Internal unit dimensions (WxHxD): 422x702x320 mm

    5 years without worries

    5 Year Warranty

    Ferroli OMNIA S 3.2 Reversible heat pumps for split installation with DC inverter compressor

    Quietness, efficiency and design

    OMNIA S 3.2 is the new range of split heat pumps Full Inverter R32 by Ferroli. The range includes an Outdoor Unit with the heart of the refrigerant circuit, from the compressor to the fan with the air side exchanger, which is connected to the refrigerant gas pipes towards the Indoor Unit. The Indoor Unit, on the other hand, contains the heart of the hydraulic circuit of the generator with all the main pre-installed components, such as the high-efficiency circulator and the expansion vessel, to safely allow quick and practical installation

    The split installation of OMNIA S 3.2 , with only the gas pipes between the outdoor and indoor unit, is synonymous with security against any freezing problem, even at the coldest temperatures (down to -25°C) and in the absence of electricity. All units meet the most extreme winter and summer air conditioning requirements, they can in fact produce hot water up to 65°C , which makes them suitable for practically all heating systems, whether radiant, fan coil or radiator, including the production of domestic hot water (DHW), via an external boiler

    The new conception Full Inverter by Ferroli uses DC inverter modulations on the 3 main energy-intensive components of the machine, i.e. compressor, fan and pump. This allows you to modulate the power supplied by finely tracking the thermal load and allowing the user very high efficiencies and important energy savings . Also, the concept Full Inverter by Ferroli guarantees sound levels among the lowest on the market, avoiding sudden changes in the network and guaranteeing a longer useful life for the components.

    Indoor and outdoor unit of OMNIA 3.2

    The Outdoor Unit contains the heart of the refrigerant circuit, while the Internal Unit the heart of the hydraulic circuit. They are connected to each other by pipes R32 ecological refrigerant gas , which has allowed us to combine high efficiency with a reduced environmental impact. Thanks to his GWP of 675 , about a third of the GWP of R410a, helps reduce CO2 equivalent emissions, the main causes of global warming

    The heat pumps use the Outdoor Unit to extract heat from the air outside the home and convey it to the water in your system, via an exchanger in the Indoor Unit. That's exactly why they manage to get such high efficiencies , exploiting so renewable the energy already present in the air outside the home

    The new conception Full Inverter by Ferroli then does the rest, tracking the thermal loads precisely and without waste (modulating the compressor, pump and fan), manages to achieve even greater efficiencies, guaranteeing important savings in bills , without stress on the components and with very low sound levels

    OMNIA S 3.2 it can be used both as the sole generator of the system and integrated with other sources such as a Ferroli boiler

    The control system

    The user interface has been equipped with capsense technology with 2.8” graphic display, which allows the user to interact with the product easily and extremely simply

    Omnia M control 3.2

    Modbus protocol It can be interfaced to BMS/BACS automation and management systems

    Heating and cooling Full Inverter modulation finely follows the desired setpoints, with the possibility of setting heating and cooling climatic curves, further optimizing consumption for the user

    Domestic hot water production When the DHW temperature probe calls the machine, it automatically switches to the domestic hot water tank with dedicated DHW set point. 3-way diverter valve supplied as standard

    Smart Grid input from photovoltaic and grid Digital Smart Grid inputs for the management of an input from the photovoltaic system and from the electricity grid. These allow you to optimize consumption and bill costs

    DHW tank electrical resistance The DHW electrical integration serves as integration, anti-legionella or reserve source in the event of an anomaly

    Fast DHW Priority to DHW production to bring the storage tank to the set point in the shortest possible time

    Anti-legionella function Allows you to set anti-legionella weekly cycles

    Silent mode Reduces the frequency of the compressor and the speed of the fan, so as to significantly reduce noise. Programmable on time slots

    ON/OFF From external contact. Activation and deactivation via an external contact, for example from a zone thermostat

    Hot / cold From external contacts. Summer/winter switching signal from outside, for example from the zone thermostat

    ECO function Dedicated setpoint for " Eco " operation. Settable with daily time band

    Anti-freeze protection Heat pump operation with circulator ON and possible electric booster


    Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    Data sheetData sheet
    • peso: 199.0 kg
    • alimentazione: single phase
    • gas: R-32
    • marca: Ferroli
    • modello: OMNIA_S_06_1
    • potenza in kw: 6
    • tipologia : Reversible
    Icon for coinShipping cost

    Shipping costs vary according to the weight of the order.

    Consult the tables with the weights for Italy and for the smaller islands and disadvantaged areas.

    Warranty detailsWarranty details

    Pursuant to art. 63 of the Consumer Code, the risk of loss and damage to the goods, for reasons not attributable to the seller, is transferred to the consumer when the latter, or a third party designated by him and other than the carrier, physically comes into possession of goods. However, the risk is transferred to the consumer as soon as the goods are delivered to the carrier. The Customer who at the time of purchase has decided to make use of the extra insurance service for the transport of the purchased goods, in the event that he finds anomalies at the time of delivery (packaging damaged or otherwise altered in the closing seals, damaged product or scratched, missing one or more packages ordered), must accept the product by writing on the document provided by the carrier: "WE ACCEPT WITH RESERVE" + description of the anomaly found. In fact, to enforce the insurance coverage it is not sufficient to note "ACCEPTED WITH RESERVE" or "ACCEPTED WITH SUBJECT TO INSPECTION", BUT the reason for the reservation must be explained in detail. If the package or the product should show visible damage, scratches or any other type of anomaly and the courier should refuse to affix a specific reserve, the goods must be refused and the incident reported immediately (and in any case in a timely manner) to the Customer Service of Decidiprice srl. In any case, without prejudice to the seller's obligations in terms of legal guarantee pursuant to articles 128 et seq. of the Consumer Code, Decidiprezzo srl will not be held responsible for any anomalies found in the state of the product, after delivery, if the Customer, in the presence of an anomaly, has accepted the package without making a specific reservation (in the corrected above). Any damage or anomalies must be reported to Customer Service by email to postvendita@climaconvenienza.it. The request must be forwarded no later than 8 calendar days from receipt of the goods. Any notification beyond the aforementioned terms will not be taken into consideration.

    Customer service detailsCustomer service details

    Our customer service department is dedicated to providing support to our customers with any problems or questions they may have before or after purchasing our products.

    Use the direct communication channel to speak to one of our operators, or send us an email to one of the addresses listed on the contact us page.

    Our customer service team is made up of highly trained professionals who are always ready to help customers solve any problem or answer any question quickly and efficiently. We are committed to ensuring maximum customer satisfaction and providing the highest quality after-sales service. So if you need any assistance, don't hesitate to contact us; we will be happy to help you in any way we can.

    Reviews of CaldaieMurali.it

    feedaty-widget

    Latest Products Viewed

    Login

    Forgot your password?

    Don't have an account yet?
    Create account