LPG operation with the use of a special conversion kit to be requested from the Authorized Assistance Centre, we recommend contacting the local assistance center before purchasing
Technical features
- Model : Divacondens D Plus F24
- Power supply: LPG
Energy efficiency
- Heating energy efficiency class: B
- Sanitary energy efficiency class: A
- ACS profile : XL
Performance
- Heat output : 7.5 ~ 25.0 kW
- Thermal power 80°C ~ 60°C : 7.2 ~ 24.2 kW
- Thermal power 50°C ~ 30°C : 7.7 ~ 26.2 kW
- Useful thermal efficiency 80°C ~ 60°C : 96.0% ~ 96.9%
- Useful thermal efficiency 50°C ~ 30°C : 102.4~ 104.0%
- NOx emissions : 6
- Maximum production of domestic hot water Δt 25°C : 13.9 l/min
- Maximum production of domestic hot water Δt 30°C : 11.6 l/min
- Heating working pressure: 0.8 ~ 3 bar
- Sanitary operating pressure: 9 bar
Dimensions and weight
- Dimensions (LxHxP): 400x680x330 mm
- Empty weight: 35.0 kg
5 years without worries
Extension of the manufacturer's standard warranty to 5 YEARS on Ferroli brand gas condensing boilers of less than 35 kW in the DIVACONDENS and BLUEHELIX series through the local authorized Ferroli technical assistance centre.
Wall-mounted boiler Ferroli DIVACONDENS D PLUS Atmospheric wall-mounted condensing boilers, with instantaneous domestic hot water production
The simplest solution for a condensing boiler
DIVACONDENS D PLUS is the condensing heat generator for traditional heating systems. The tried and tested Ferroli technology in the field of traditional wall mounted boilers has been enriched by increasing the performance of the product in the simplest way, with the use of a robust recuperator which preheats the primary circuit using the residual heat of the exhaust fumes and a new cooled burner with low NOx emissions. DIVACONDENS D PLUS is offered in a single model for heating and instantaneous production of domestic hot water
Product plus
> Condensing boiler for heating high temperature systems and producing domestic hot water. It is not suitable for combination with direct delivery to systems with low temperature radiant panels
> Compact geometry primary exchanger
> Instant production of domestic hot water with dedicated plate exchanger
> Post-recovery of the latent heat of condensation, in function of pre-heating of the primary circuit
> Forced draught sealed chamber boiler, with water-cooled atmospheric burner with low NOx emissions
> Standard automatic hydraulic by-pass
> Minimum polluting emissions, class 6 according to EN 15502-1
> High-efficiency, low-consumption circulator with anti-blocking system by activation for a few seconds every 24 hours of inactivity
> Can be combined with the modulating remote timer control
> Simple and complete control panel, display user interface, with setting keys
> Robust post-condenser fed by the closed circuit of the primary. The heat exchange with the fumes takes place inside large diameter water passages
> Generator with simple and rational operation
> ECO function in DHW for greater savings in the period of low use of hot water
> Predisposition for solar systems : prearranged for the production of domestic hot water combined with solar panel systems
> Place of installation : also for outdoors in a partially protected place down to -5°C as standard
> Certified operation also with propane air (50% air - 50% G31) by means of a specific transformation to be requested from the Authorized Assistance Center
> Also works on LPG with the use of a special conversion kit to be requested from the Authorized Assistance Centre
Boiler control
The DIVACONDENS D PLUS control unit consists of an easy-to-use interface with a backlit display. Using the buttons, it is possible to easily adjust the heating flow temperature, the domestic hot water setpoint, switch the generator on/off or activate the comfort function, monitoring the status of the boiler. The control panel is completed by a traditional pressure gauge which can check the system pressure at any time.
Main components
-
Heat recovery Post-condenser with recovery of latent heat from the combustion fumes and condensate discharge
-
Steel frame Made with high precision automated processes. Incorporates an 8 liter expansion vessel
-
Central heating primary exchanger protected by a non-toxic aluminum coating
-
Low NOx burner Water-cooled low temperature micro flame type. Minimum NOx emissions
-
High efficiency circulator , for heating and exchange with the DHW circuit
-
Domestic hot water exchanger In stainless steel, with copper brazing
-
ECS - Evolved Combustion System Innovative combustion control that guarantees optimal functioning under various thermal load conditions and types of chimney
Optimize comfort and savings "ROMEO N" timer control
The ROMEO N timer control allows control and setting of the boiler functions directly from the room in which it is installed. Comfort programming is possible on a weekly basis and also includes the 'holiday' function. ROMEO N is available with wired or wireless connection.
With ROMEO N you can:
- Adjust the heating and DHW temperatures
- Know the operating status of the boiler
- View the indoor temperature in your home
- Program the weekly ambient comfort
- Activating/deactivating the heating function via the telephone (Optional)
Smart CONNECT remote control
Remote control supplied with the class A+ kit code for home comfort management also from a Smartphone
Possibility of managing up to 8 zones using additional room units
Connection to the home Wi-Fi network via the supplied RF/Wi-Fi receiver
CONNECT APP available for boiler on/off and domestic heating/DHW comfort management remotely via Smartphone (iOS and Android)
Maximization of room comfort with modulating regulation of the flow temperature through the Room Climatic Compensation functions differentiated for each zone and External Climatic Compensation via external temperature detectable directly from the internet or from an optional external probe
It improves the average seasonal efficiency in space heating by +4%.
Weekly time programming in 30-minute intervals via APP CONNECT
Operating modes : Off, Holiday, Automatic, Manual
Three modifiable temperature levels : Comfort, Economy, Antifreeze
By reading the external temperature directly from the internet (or from the optional external probe) the system is able to vary the system temperature according to the external temperature measured on the basis of configurable climatic curves, thus guaranteeing the user maximum room comfort at the change in external climatic conditions.
The modulating function of CONNECT allows modulation of the boiler power as the set room temperature value is reached. This improves the quality of comfort by eliminating heat peaks with consequent energy savings
Solar circuit integration Sun Easy function
DIVACONDENS D PLUS boasts electronics that simplify integration with thermal solar systems, both with natural and forced circulation. The microprocessor controls the temperature of the water coming from the solar circuit through the domestic hot water sensor and turns on the burner only if necessary.
In case of insufficient irradiation and therefore a modest pre-heating of the domestic water, the boiler will contribute with the heat necessary to reach the required set point temperature.
If the sun and the solar system fulfill their "duty" no integration by the boiler will be necessary, the hot water will be conveyed to the tap, without the need for additional devices, with the mixing of the thermostatic valves.
To reach the desired temperature, SUN EASY allows considerable savings even during the coldest seasons, exploiting and integrating even the smallest solar contribution, otherwise lost.
Safety and comfort Functions
Antifreeze In the event that the temperature in the boiler drops to 5°C, the burner ignites automatically and the circulator is activated in order to protect the appliance from damage caused by freezing. This function is active with the boiler powered by the gas circuit and under electrical voltage
Post-circulation This function makes it possible to recover all the heat supplied by thermal inertia of the exchanger and transfer it to the heating system, and consequently to the rooms to be heated. This is a timer function and is active after the burner goes out in heating mode.
Sliding temperature operation With the installation of the “External probe” kit it is possible to operate the boiler in sliding temperature. This means that without using the system temperature adjustment keys, the boiler will self-regulate according to the variations in external temperatures. All this translates into energy savings while ensuring maximum comfort for the user
Easy Control The electronic board of DIVACONDENS D PLUS adopts the Opentherm protocol. It allows the integration of other peripheral control units such as, for example, the ROMEO N and CONNECT remote timer controls. In fact, the Opentherm standard has been specially designed to share the logic and operating algorithms of the boiler with other additional control units. As a digital protocol, it allows total integration between the boiler and the satellite, with full control of the functions from the boiler and similarly from its satellite
Product Guarantee : All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.