- DHW nominal heat input kW (kcal/h) 31.0 (26655)
- Nominal heat input * heating kW (kcal/h) 26.0 (22356)
- Maximum useful power in heating 60/80° kW (kcal/h) 25.4 (1840)
- Useful power in domestic hot water 60/80° kW (kcal/h) ) 30.3 (26053)
- Efficiency at 100% load (50/30 °C) % 107.3
- Sanitary flow rate ?t =25°K l/min 17.6
- NOx class 6
- LPG code 10304.2029.0
- Dimensions HxWxD mm 703x400x325
BASIC COND
Basica Cond Basica Cond completes the BIASI range with premixed condensing: perfect for radiator systems and suitable for radiant systems with mixing groups. Basica is the compact condensing boiler that ensures high efficiency, low consumption and respect for the environment. Available for heating and domestic hot water production, in power ratings of 25 and 30 kW.
Main features
Primary condensing exchanger in stainless steel with steel lining to offer maximum resistance to corrosion - Total premix burner, stainless steel (Class NOx 6)
- Modulation 1:5 CNG and also LPG
- Sanitary plate heat exchanger in stainless steel
- 8 liter expansion vessel
- High efficiency pump with low energy consumption
- Can be installed in a partially protected place
- Integration with BIASI solar systems, using a solar kit
- Analog pressure reading
- Arrangement for remote control and external probe
High circulation single coil primary heat exchanger
Biasi introduces on the market the new stainless steel heat exchanger for condensing boilers: Round. Round is a compact monothermal heat exchanger based on a stainless steel coil with an oval section. The heat exchanger consists of a combustion chamber, condensing area and an insulated metal disc protected with silicone ceramic fiber which separates the two areas. By using a single strip of stainless steel to produce the coil, including inlet/outlet fittings, the following benefits are achieved:
- The accumulation of dirt and debris is avoided
- The water flow rate is constant, guaranteeing a higher average life of the product
- Reduction of load losses with optimized circuit.
The ease of cleaning and the sturdiness of this exchanger are one of the main strengths of the product since it can be used on new systems but also on old systems in the event of renovations. Round integrates the round flow function in which the water produces a centrifugal cleaning effect on the internal walls of the single coil. The absence of circuits in parallel guarantees an easy "washing" operation of the exchanger and the elimination of any air present in the system circuit.
Included in delivery
- Boiler support bracket and paper template
- Boiler power cable
- Condensate collection siphon
- Quick instruction to the user.
Control panel
- Summer/winter/off selector
- Heating temperature regulator
- DHW temperature regulator
- Analog pressure reading
- DHW and heating temperature visualization from the display
- Display of fault diagnostics, block status and fault history
The display operates in the following modes:
- INFO – information available on the operating status and error history
- FREE programming – programmable parameters for generator/system adjustment and User SET
- INSTALLER programming - generator parameters
- ASSISTANCE programming - Authorized Assistance Center parameters
commands
The Basica Cond Range has the choice of 2 class V remote controls (they allow deduction at 65), in the Base and Top version with weekly chronothermostat functions with up to 4 programmable periods with independent temperatures, in addition to the remote control of all the information of the boiler display.