icon Beretta Wall-Mounted Open Chamber Boiler Mynute 24 Cai Lx Low Nox 24 Kw Methane Cod. 20151436 | CaldaieMurali

Beretta Wall-Mounted Open Chamber Boiler Mynute 24 Cai Lx Low Nox 24 Kw Methane Cod. 20151436

Description

BERETTA WALL-MOUNTED BOILER Open chamber MYNUTE 24 CAI LX Low Nox 24 kw CNG cod. 20151436


Mynute LOW NOX

  • Nominal heat input kW 25.80
  • Nominal thermal power (80 - 60 °C) kW 24.05
  • Reduced thermal power (80 - 60 °C) kW 11.28
  • Reduced heat input kW 12.5
  • Electric power Watt 115
  • Supply voltage / frequency Volt/Hz 230 / 50
  • Electrical protection degree IP X5D
  • Useful efficiency at Pn max ((80 - 60 °C) % 93.2
  • Useful efficiency at 30% of Pn (47 °C return) % 91.8
  • POLLUTANT EMISSIONS (G20)
  • NOx according to UNI EN 483 class 5

HEATING EXERCISE

  • Maximum pressure and temperatures bar/°C 3 / 90
  • Heating temperature selection range °C 40 / 80
  • Pump: pump head available for the system mbar 275
  • at a flow rate of 1000 litres/h
  • Expansion vessel capacity 9 litres

HEALTHCARE EXERCISE

  • Maximum pressure 6 bar
  • Minimum pressure bar 0.15
  • Quantity of hot water with ∆t=25°C litres/min 14
  • Minimum domestic water flow rate litres/min 2
  • DHW temperature selection range °C 37 - 60

CONNECTIONS

  • Heating inlet - outlet Ø 3/4”
  • DHW inlet - outlet Ø 1/2”
  • Gas inlet Ø 3/4”

COAXIAL FUME EXHAUST AND AIR INTAKE PIPES

  • Diameter mm 60 - 100
  • Maximum length 2.5 m
  • Loss for inserting a 90° / 45° bend m 1.5 / 1

SEPARATE FUME EXHAUST AND AIR INTAKE PIPES

  • Diameter mm 80 + 80
  • Maximum length m 14 + 14
  • Loss for inserting a 90° / 45° bend m 1.7 / 1.2
  • DIMENSIONS, WEIGHT, GAS
  • Boiler size (HxLxP) mm 780x400x338
  • Weight kg 35

Wall mounted boiler Beretta MYNUTE 24 CAI LX

  • natural draft open instant combined methane
  • Heating capacity 24kW and DHW (l/min-?t 25°C) 14,
  • with low Nox emissions, specifically designed to facilitate the replacement of pre-existing wall boilers,

Simple and intuitive digital display.

Technical features:

  • New boilers with low NOx emissions
  • Low consumption circulator (EEI?0.20) as standard
  • Specifically designed to facilitate the replacement of pre-existing wall-mounted boilers
  • 9 liter expansion tank
  • Simple and intuitive digital display
  • Predisposition for climatic thermoregulation (optional external probe)Predisposition for connection to the BeSMART Comfort control (code 20143539)
  • IPX5D electrical protection degree
  • Plumbing fittings, gas and sanitary taps (optional)

The ecological burner

  • To reach high standards
  • Mynute Low NOx is equipped with a
  • special atmospheric burner,
  • cooled and equipped with nozzles in number
  • superior, which allows the specification
  • premixing of gas and air. In this
  • how combustion occurs a
  • temperatures lower than usual
  • in a traditional burner. The burner
  • consists of a surface on the
  • which develops the high flame few
  • millimeters, also called "microflame".
  • The tube that passes through the burner with
  • the return water from the system
  • heating promotes cooling
  • of the burner surface.

Product Warranty The warranty on this item is 24 months from the date of purchase.

Beretta Wall-Mounted Open Chamber Boiler Mynute 24 Cai Lx Low Nox 24 Kw Methane Cod. 20151436

Product form

BERETTA WALL-MOUNTED BOILER Open chamber MYNUTE 24 CAI LX Low Nox 24 kw CNG cod. 20151436 Mynute LOW NOX Nominal... Read more

€672,00 Incl. VAT

    Description

    BERETTA WALL-MOUNTED BOILER Open chamber MYNUTE 24 CAI LX Low Nox 24 kw CNG cod. 20151436


    Mynute LOW NOX

    • Nominal heat input kW 25.80
    • Nominal thermal power (80 - 60 °C) kW 24.05
    • Reduced thermal power (80 - 60 °C) kW 11.28
    • Reduced heat input kW 12.5
    • Electric power Watt 115
    • Supply voltage / frequency Volt/Hz 230 / 50
    • Electrical protection degree IP X5D
    • Useful efficiency at Pn max ((80 - 60 °C) % 93.2
    • Useful efficiency at 30% of Pn (47 °C return) % 91.8
    • POLLUTANT EMISSIONS (G20)
    • NOx according to UNI EN 483 class 5

    HEATING EXERCISE

    • Maximum pressure and temperatures bar/°C 3 / 90
    • Heating temperature selection range °C 40 / 80
    • Pump: pump head available for the system mbar 275
    • at a flow rate of 1000 litres/h
    • Expansion vessel capacity 9 litres

    HEALTHCARE EXERCISE

    • Maximum pressure 6 bar
    • Minimum pressure bar 0.15
    • Quantity of hot water with ∆t=25°C litres/min 14
    • Minimum domestic water flow rate litres/min 2
    • DHW temperature selection range °C 37 - 60

    CONNECTIONS

    • Heating inlet - outlet Ø 3/4”
    • DHW inlet - outlet Ø 1/2”
    • Gas inlet Ø 3/4”

    COAXIAL FUME EXHAUST AND AIR INTAKE PIPES

    • Diameter mm 60 - 100
    • Maximum length 2.5 m
    • Loss for inserting a 90° / 45° bend m 1.5 / 1

    SEPARATE FUME EXHAUST AND AIR INTAKE PIPES

    • Diameter mm 80 + 80
    • Maximum length m 14 + 14
    • Loss for inserting a 90° / 45° bend m 1.7 / 1.2
    • DIMENSIONS, WEIGHT, GAS
    • Boiler size (HxLxP) mm 780x400x338
    • Weight kg 35

    Wall mounted boiler Beretta MYNUTE 24 CAI LX

    • natural draft open instant combined methane
    • Heating capacity 24kW and DHW (l/min-?t 25°C) 14,
    • with low Nox emissions, specifically designed to facilitate the replacement of pre-existing wall boilers,

    Simple and intuitive digital display.

    Technical features:

    • New boilers with low NOx emissions
    • Low consumption circulator (EEI?0.20) as standard
    • Specifically designed to facilitate the replacement of pre-existing wall-mounted boilers
    • 9 liter expansion tank
    • Simple and intuitive digital display
    • Predisposition for climatic thermoregulation (optional external probe)Predisposition for connection to the BeSMART Comfort control (code 20143539)
    • IPX5D electrical protection degree
    • Plumbing fittings, gas and sanitary taps (optional)

    The ecological burner

    • To reach high standards
    • Mynute Low NOx is equipped with a
    • special atmospheric burner,
    • cooled and equipped with nozzles in number
    • superior, which allows the specification
    • premixing of gas and air. In this
    • how combustion occurs a
    • temperatures lower than usual
    • in a traditional burner. The burner
    • consists of a surface on the
    • which develops the high flame few
    • millimeters, also called "microflame".
    • The tube that passes through the burner with
    • the return water from the system
    • heating promotes cooling
    • of the burner surface.

    Product Warranty The warranty on this item is 24 months from the date of purchase.

    Data sheetData sheet
    • peso: 35.0 kg
    • classe energetica produzione acs: B
    • classe energetica riscaldamento: C
    • gas: Methane
    • marca: BERETTA
    • metri quadri : 120
    • modello: 20151436
    • potenza in kw: 24
    • potenza nominale: 24
    • superficie riscaldabile mq: 120
    Icon for coinShipping cost

    Shipping costs vary according to the weight of the order.

    Consult the tables with the weights for Italy and for the smaller islands and disadvantaged areas.

    Warranty detailsWarranty details

    Pursuant to art. 63 of the Consumer Code, the risk of loss and damage to the goods, for reasons not attributable to the seller, is transferred to the consumer when the latter, or a third party designated by him and other than the carrier, physically comes into possession of goods. However, the risk is transferred to the consumer as soon as the goods are delivered to the carrier. The Customer who at the time of purchase has decided to make use of the extra insurance service for the transport of the purchased goods, in the event that he finds anomalies at the time of delivery (packaging damaged or otherwise altered in the closing seals, damaged product or scratched, missing one or more packages ordered), must accept the product by writing on the document provided by the carrier: "WE ACCEPT WITH RESERVE" + description of the anomaly found. In fact, to enforce the insurance coverage it is not sufficient to note "ACCEPTED WITH RESERVE" or "ACCEPTED WITH SUBJECT TO INSPECTION", BUT the reason for the reservation must be explained in detail. If the package or the product should show visible damage, scratches or any other type of anomaly and the courier should refuse to affix a specific reserve, the goods must be refused and the incident reported immediately (and in any case in a timely manner) to the Customer Service of Decidiprice srl. In any case, without prejudice to the seller's obligations in terms of legal guarantee pursuant to articles 128 et seq. of the Consumer Code, Decidiprezzo srl will not be held responsible for any anomalies found in the state of the product, after delivery, if the Customer, in the presence of an anomaly, has accepted the package without making a specific reservation (in the corrected above). Any damage or anomalies must be reported to Customer Service by email to postvendita@climaconvenienza.it. The request must be forwarded no later than 8 calendar days from receipt of the goods. Any notification beyond the aforementioned terms will not be taken into consideration.

    Customer service detailsCustomer service details

    Our customer service department is dedicated to providing support to our customers with any problems or questions they may have before or after purchasing our products.

    Use the direct communication channel to speak to one of our operators, or send us an email to one of the addresses listed on the contact us page.

    Our customer service team is made up of highly trained professionals who are always ready to help customers solve any problem or answer any question quickly and efficiently. We are committed to ensuring maximum customer satisfaction and providing the highest quality after-sales service. So if you need any assistance, don't hesitate to contact us; we will be happy to help you in any way we can.

    Reviews of CaldaieMurali.it

    feedaty-widget

    Latest Products Viewed

    Login

    Forgot your password?

    Don't have an account yet?
    Create account