icon Baxi AURIGA 16M R32 Inverter Monobloc Air-Water Heat Pump Single Phase with Remote Control Panel Included | CaldaieMurali

Baxi AURIGA 16M R32 Inverter Monobloc Air-Water Heat Pump Single Phase with Remote Control Panel Included

Description

VALID WHILE STOCKS LAST

FIRST START-UP INCLUDED!

Technical features

  • Model : Auriga 16M
  • Remote control panel A7750381

Heating with low temperature application

Outside air temperature 7°C87% RH Water temperature 30/35°C

  • Nominal thermal power: 16.30 kW
  • COP : 4.45

Outside air temperature 7°C87% RH Water temperature 40/45°C

  • Nominal thermal power: 16.20 kW
  • COP : 3.43

Heating with medium temperature application

Outside air temperature 7°C87% RH Water temperature 47/55°C

  • Nominal thermal power: 16.10 kW
  • COP : 2.73

Cooling

Outside air temperature 35°CWater temperature 23/18°C

  • Nominal cooling capacity: 15.50 kW
  • EER : 4.26

Outside air temperature 35°CWater temperature 7°C

  • Nominal cooling capacity: 13.80 kW
  • EER : 2.65

Energy efficiency

  • Seasonal low temperature space heating energy efficiency: 169%
  • Seasonal energy efficiency of medium temperature space heating: 128%
  • Seasonal low temperature energy efficiency class: A+++
  • Seasonal energy efficiency class at medium temperature: A++

Performance

  • Exchanger water flow rate: 2.82 m3 /h
  • Pump useful head: 62 kPa
  • Sound power level: 71 dB(A)
  • Sound pressure level: 58.1 dB(A)

Electrical data

  • Power supply (V,Hz,Ø) : 220~240/50/1
  • Refrigerant gas: R32
Installation data
  • Hydraulic pipe diameter: 1'' 1/4

Dimensions and weight

  • Dimensions (HxWxD): 1414x1404x373 mm
  • Empty weight: 158.0 Kg

Monobloc Inverter Air-Water Heat Pumps BAXI AURIGA

Baxi introduces Auriga , the new range of monobloc inverter air-water heat pumps with single-phase and three-phase power supply. The range is characterised by ease and simplicity of installation . Furthermore, the increased prevalence of the on-board circulator allows the unit to be installed in large systems, covering greater distances from the heating plant or installing the unit directly to serve the fan coils. The range is wide and consists of 7 models from 5 to 16 kW, single-phase and three-phase versions .

Wide range of power from 5 to 16 kW to satisfy all system needs: heating, cooling and DHW production

Easy to install in various living contexts The increased head pump allows you to deal with greater pressure drops such as large systems or directly serving fan coils.

Remote control panel Allows control of system functions, programming and parameter verification. Furthermore, the Modbus connection allows integration with BMS systems.

Components

Twin rotary DC inverter compressor complete with internal thermal protection and crankcase resistance, it is mounted on anti-vibration rubbers and wrapped on an insulating casing to reduce the transmission of noise and vibrations due to operation

Brazed plate water-coolant exchanger in AISI 316 steel with external anti-condensation insulation in expanded polypropylene and anti-freeze resistance to prevent ice formation in the exchanger

Air-refrigerant exchanger finned aluminium battery with hydrophilic treatment to facilitate the flow of condensation, mechanically expanded copper tubes with internal shaping to increase heat exchange. Furthermore, the optimised circuitry allows for a reduction in ice formation in the battery during heat pump operation.

Axial fan fan directly coupled to the variable speed brushless DC motor with high efficiency. The fan is installed on aerodynamic nozzles and safety grilles

Refrigeration circuit made of pickled copper, includes the electronic expansion valve, dehydrating filters, high and low pressure switches, pressure transducer, cycle reversal valves, liquid receiver and separator, refrigerant injection valve in suction

Hydraulic circuit in addition to the brazed plate exchanger, the unit includes the high-head circulator, the expansion vessel, the safety valve, the flow switch, the pressure gauge and the air vent valve and the metal mesh Y-filter, assembly by the installer

Electrical panel includes fuse protection of the main internal components; the terminal block is divided into a power section for powering the unit and a control terminal block for connecting auxiliary inputs and outputs and connection to the control panel

Baxi Auriga

  • Maximum energy efficiency
  • Monoblock system for the production of heating, cooling and DHW
  • Wide operating range, with external air up to -25°C in heating, up to 46°C in cooling
  • ACS system management: production up to 60°C, boiler temperature management, ACS recirculation pump and solar thermal integration
  • Suitable for integration with radiant terminals, fan coils and mixed systems
  • Integrated management with different system systems: boiler integration, solar integration, diverter valve management and secondary circuit pump
  • Intelligent defrosting thanks to the simultaneous monitoring of ambient temperature, refrigerant temperature, produced water temperature and operating mode
  • Compressor with DC inverter technology with high modulation range
  • Modbus network connection
  • Low GWP R-32 refrigerant

Standard control functions Control panel to manage different system configurations directly from the unit

  • Heating and cooling management with 16 different climate curves per mode
  • ACS boiler management, solar integration, boiler and ACS recirculation pump management
  • Boiler integration management and backup electric resistance
  • Anti-legionella function
  • Eco mode with double adjustable setpoint
  • Silent mode with 2 adjustable silence levels
  • Holiday mode: antifreeze and DHW management with dedicated setpoints and anti-legionella treatment on DHW at the end of the set mode

Product Warranty: All products for sale on our site are new and packaged. The warranty on this item is 24 months from the date of purchase.

Baxi AURIGA 16M R32 Inverter Monobloc Air-Water Heat Pump Single Phase with Remote Control Panel Included

Product form

VALID WHILE STOCKS LAST FIRST START-UP INCLUDED! Technical features Model : Auriga 16M Remote control panel A7750381 Heating with low... Read more

€4.300,00 Incl. VAT

    Description

    VALID WHILE STOCKS LAST

    FIRST START-UP INCLUDED!

    Technical features

    • Model : Auriga 16M
    • Remote control panel A7750381

    Heating with low temperature application

    Outside air temperature 7°C87% RH Water temperature 30/35°C

    • Nominal thermal power: 16.30 kW
    • COP : 4.45

    Outside air temperature 7°C87% RH Water temperature 40/45°C

    • Nominal thermal power: 16.20 kW
    • COP : 3.43

    Heating with medium temperature application

    Outside air temperature 7°C87% RH Water temperature 47/55°C

    • Nominal thermal power: 16.10 kW
    • COP : 2.73

    Cooling

    Outside air temperature 35°CWater temperature 23/18°C

    • Nominal cooling capacity: 15.50 kW
    • EER : 4.26

    Outside air temperature 35°CWater temperature 7°C

    • Nominal cooling capacity: 13.80 kW
    • EER : 2.65

    Energy efficiency

    • Seasonal low temperature space heating energy efficiency: 169%
    • Seasonal energy efficiency of medium temperature space heating: 128%
    • Seasonal low temperature energy efficiency class: A+++
    • Seasonal energy efficiency class at medium temperature: A++

    Performance

    • Exchanger water flow rate: 2.82 m3 /h
    • Pump useful head: 62 kPa
    • Sound power level: 71 dB(A)
    • Sound pressure level: 58.1 dB(A)

    Electrical data

    • Power supply (V,Hz,Ø) : 220~240/50/1
    • Refrigerant gas: R32
    Installation data
    • Hydraulic pipe diameter: 1'' 1/4

    Dimensions and weight

    • Dimensions (HxWxD): 1414x1404x373 mm
    • Empty weight: 158.0 Kg

    Monobloc Inverter Air-Water Heat Pumps BAXI AURIGA

    Baxi introduces Auriga , the new range of monobloc inverter air-water heat pumps with single-phase and three-phase power supply. The range is characterised by ease and simplicity of installation . Furthermore, the increased prevalence of the on-board circulator allows the unit to be installed in large systems, covering greater distances from the heating plant or installing the unit directly to serve the fan coils. The range is wide and consists of 7 models from 5 to 16 kW, single-phase and three-phase versions .

    Wide range of power from 5 to 16 kW to satisfy all system needs: heating, cooling and DHW production

    Easy to install in various living contexts The increased head pump allows you to deal with greater pressure drops such as large systems or directly serving fan coils.

    Remote control panel Allows control of system functions, programming and parameter verification. Furthermore, the Modbus connection allows integration with BMS systems.

    Components

    Twin rotary DC inverter compressor complete with internal thermal protection and crankcase resistance, it is mounted on anti-vibration rubbers and wrapped on an insulating casing to reduce the transmission of noise and vibrations due to operation

    Brazed plate water-coolant exchanger in AISI 316 steel with external anti-condensation insulation in expanded polypropylene and anti-freeze resistance to prevent ice formation in the exchanger

    Air-refrigerant exchanger finned aluminium battery with hydrophilic treatment to facilitate the flow of condensation, mechanically expanded copper tubes with internal shaping to increase heat exchange. Furthermore, the optimised circuitry allows for a reduction in ice formation in the battery during heat pump operation.

    Axial fan fan directly coupled to the variable speed brushless DC motor with high efficiency. The fan is installed on aerodynamic nozzles and safety grilles

    Refrigeration circuit made of pickled copper, includes the electronic expansion valve, dehydrating filters, high and low pressure switches, pressure transducer, cycle reversal valves, liquid receiver and separator, refrigerant injection valve in suction

    Hydraulic circuit in addition to the brazed plate exchanger, the unit includes the high-head circulator, the expansion vessel, the safety valve, the flow switch, the pressure gauge and the air vent valve and the metal mesh Y-filter, assembly by the installer

    Electrical panel includes fuse protection of the main internal components; the terminal block is divided into a power section for powering the unit and a control terminal block for connecting auxiliary inputs and outputs and connection to the control panel

    Baxi Auriga

    • Maximum energy efficiency
    • Monoblock system for the production of heating, cooling and DHW
    • Wide operating range, with external air up to -25°C in heating, up to 46°C in cooling
    • ACS system management: production up to 60°C, boiler temperature management, ACS recirculation pump and solar thermal integration
    • Suitable for integration with radiant terminals, fan coils and mixed systems
    • Integrated management with different system systems: boiler integration, solar integration, diverter valve management and secondary circuit pump
    • Intelligent defrosting thanks to the simultaneous monitoring of ambient temperature, refrigerant temperature, produced water temperature and operating mode
    • Compressor with DC inverter technology with high modulation range
    • Modbus network connection
    • Low GWP R-32 refrigerant

    Standard control functions Control panel to manage different system configurations directly from the unit

    • Heating and cooling management with 16 different climate curves per mode
    • ACS boiler management, solar integration, boiler and ACS recirculation pump management
    • Boiler integration management and backup electric resistance
    • Anti-legionella function
    • Eco mode with double adjustable setpoint
    • Silent mode with 2 adjustable silence levels
    • Holiday mode: antifreeze and DHW management with dedicated setpoints and anti-legionella treatment on DHW at the end of the set mode

    Product Warranty: All products for sale on our site are new and packaged. The warranty on this item is 24 months from the date of purchase.

    Data sheetData sheet
    • peso: 199.0 kg
    • alimentazione: Single phase
    • gas: R-32
    • marca: BAXI
    • modello: AURIGA 16M_1
    • potenza in kw: 16
    • tipologia : Monobloc
    Icon for coinShipping cost

    Shipping costs vary according to the weight of the order.

    Consult the tables with the weights for Italy and for the smaller islands and disadvantaged areas.

    Warranty detailsWarranty details

    Pursuant to art. 63 of the Consumer Code, the risk of loss and damage to the goods, for reasons not attributable to the seller, is transferred to the consumer when the latter, or a third party designated by him and other than the carrier, physically comes into possession of goods. However, the risk is transferred to the consumer as soon as the goods are delivered to the carrier. The Customer who at the time of purchase has decided to make use of the extra insurance service for the transport of the purchased goods, in the event that he finds anomalies at the time of delivery (packaging damaged or otherwise altered in the closing seals, damaged product or scratched, missing one or more packages ordered), must accept the product by writing on the document provided by the carrier: "WE ACCEPT WITH RESERVE" + description of the anomaly found. In fact, to enforce the insurance coverage it is not sufficient to note "ACCEPTED WITH RESERVE" or "ACCEPTED WITH SUBJECT TO INSPECTION", BUT the reason for the reservation must be explained in detail. If the package or the product should show visible damage, scratches or any other type of anomaly and the courier should refuse to affix a specific reserve, the goods must be refused and the incident reported immediately (and in any case in a timely manner) to the Customer Service of Decidiprice srl. In any case, without prejudice to the seller's obligations in terms of legal guarantee pursuant to articles 128 et seq. of the Consumer Code, Decidiprezzo srl will not be held responsible for any anomalies found in the state of the product, after delivery, if the Customer, in the presence of an anomaly, has accepted the package without making a specific reservation (in the corrected above). Any damage or anomalies must be reported to Customer Service by email to postvendita@climaconvenienza.it. The request must be forwarded no later than 8 calendar days from receipt of the goods. Any notification beyond the aforementioned terms will not be taken into consideration.

    Customer service detailsCustomer service details

    Our customer service department is dedicated to providing support to our customers with any problems or questions they may have before or after purchasing our products.

    Use the direct communication channel to speak to one of our operators, or send us an email to one of the addresses listed on the contact us page.

    Our customer service team is made up of highly trained professionals who are always ready to help customers solve any problem or answer any question quickly and efficiently. We are committed to ensuring maximum customer satisfaction and providing the highest quality after-sales service. So if you need any assistance, don't hesitate to contact us; we will be happy to help you in any way we can.

    Reviews of CaldaieMurali.it

    feedaty-widget

    Latest Products Viewed

    Login

    Forgot your password?

    Don't have an account yet?
    Create account