icon Baxi Prime 30 Condensing Gas Boiler Complete With LPG Or Methane Fume Kit - New Erp Model | CaldaieMurali

Baxi Prime 30 Condensing Gas Boiler Complete With LPG Or Methane Fume Kit - New Erp Model

Description

Easy to use thanks to the control panel equipped with knobs
and backlit LCD display
• Easy installation thanks to ultra-compact dimensions
(700x395x279 mm – including knobs) and low weight (26 kg)
• Easy replacement of conventional boilers thanks to central flue gas outlet
• Modulation range 1:5 greater efficiency and silence
• High efficiency circulation pump
• Arrangement for combination with the Baxi integrated solar system
• Ø 80 double exhaust as standard
• Connection to rigid and flexible Ø 50 mm exhaust pipe: solutions for restoring flues, total length (exhaust +
suction) 40 meters
• Connection to pressurized collective flues
Boilers running on methane that can be converted to LPG and propane air by means of a specific regulation (conversion kit not necessary )




  • TECHNICAL FEATURES
  • Installation type: B23-B23P-B33-C13-C33-C43-C53-C63-C83-C93
  • DHW nominal heat input: 20.9 kW
  • Sanitary nominal thermal power: 30 kW
  • Nominal heating heat input: 24.7 kW
  • Heating rated thermal power 80/60°C: 24 kW
  • Heating rated thermal power 50/30°C: 26.1 kW
  • Reduced thermal power 80/60°C : 5.6 kW
  • Reduced thermal power 50/30°C: 6 kW
  • Efficiency at 30%: 105.8%
  • Nominal efficiency 80/60°C: 97.5%
  • Nominal efficiency 50/30°C: 105.8%
  • Seasonal space heating energy efficiency class: A
  • Seasonal energy efficiency class of the sanitary fixture: A
  • Water heating – Load profile: XL
  • NOx class 5
  • Domestic hot water production: ∆T 25°C: 13.8 l/min
  • Category II2HM3B/P appliance operating on gas type G20 – G230 – G30 – G31
  • Electronic ignition with flame ionization control
  • Degree of protection: IPX5D
  • Primary water/gas coil exchanger in AISI 316L stainless steel
  • Secondary water/water exchanger in stainless steel
  • Electric 3-way diverter valve
  • Modulating fan with electronic speed variation
  • Automatic by-pass on the heating circuit
  • Digital and analog pressure gauge on the heating circuit
  • Heating expansion tank with capacity 7 l and preload 0.8 bar
  • High efficiency ErP full modulation circulation pump with built-in deaerator
  • Hall effect DHW flowmeter for detecting hot water withdrawal
  • DHW operation with minimum water pressure of 0.15 bar and minimum flow rate of 2 l/min.
  • Inspectable filter on loading water inlet
  • Primary circuit safety valve at 3 bar
  • Heating water temperature adjustment range: 25÷80°C
  • Domestic water temperature adjustment range (in the case of combination with a boiler): 35÷60°C
  • Minimum operating temperature: – 5°C
  • Dimensions hxwxd: 700 x 395 x 279 mm
  • Weight 26kg
  • CONTROL SYSTEM
  • Temperature control using NTC probes
  • Pump post-circulation in heating function
  • Safety thermostat against overheating of the water/fumes exchanger
  • Hydraulic pressure switch which blocks the gas in case of water shortage
  • Pump electronic control blocked
  • Pump anti-blocking system and 3-way valve which intervenes every 24 hours
  • NTC safety probe against fume overheating
  • Total antifreeze device which intervenes with temperatures below 5°C
  • Electronic thermometer
  • Display of heating circuit pressure on control panel

 

THE ADVANTAGES OF PRIME

EASY TO INSTALL

The ultra-compact dimensions 700x395x279 mm and the weight of just 26 kg reduce installation time. The new Prime has the same distance between centers of the hydraulic connections of the conventional BAXI boilers to be replaced. Front access to the electrical connection also speeds up connection times.
The fixing bracket supplied as standard and the visible hooks facilitate wall mounting.

 

 

 

LOWER ENERGY CONSUMPTION

Thanks to the condensing technology, the high efficiency pump and the series of modulating room thermostats available as an accessory.
The new regulation 7129-3:2015 prescribes the possibility of creating collective flues in positive pressure only for type C condensing appliances.
It is possible to connect to a collective flue in positive pressure only appliances declared suitable by the manufacturer for this application and equipped with a non-return device (clapet), designed to prevent the combustion products from flowing out through appliances connected and temporarily switched off; the smoke non-return valve is an integral part of the appliance.

 

 

 

 

THE REGULATION 7129-3:2015

Regulation 7129-3:2015 prescribes the possibility of creating collective flues in positive pressure only
for type C condensing appliances.
Only devices declared suitable can be connected to a positive pressure collective flue
by the manufacturer for this application and equipped with a non-return device (clapet), designed to prevent the products from
combustion to flow through appliances connected and momentarily switched off; the smoke non-return valve is part
component of the appliance.

 

 

  • CLAPET (SMOKE NON-RETURN VALVE)

Included in the duct downstream of the air-gas group fan.

 

 

 

 

 

  • CONNECTED TO COLLECTIVE PRESSURIZED FLUES

Thanks to the integrated flue non-return valve (clapet), Prime is designed for connection to pressurized collective flues.

 

 

 

 

 

 

 

 

 

 

 

 

 

SMOKE PIPES Ø50 MM

Possibility of restoring flues with Ø50 mm exhaust hose (up to 40m of exhaust)

 

 

FLEXIBILITY IN THE REPLACEMENT

Easy replacement of old standard boilers, thanks to the central flue outlet and the separate adjustable outlet supplied as standard.

 

The Ø 60/100 coaxial drain is available as an accessory that can be combined with a pipe extension and a 60/100 diameter 90° elbow (360° adjustable).

 

To facilitate replacement in installations where space is limited (flue gas outlet at the rear of the boiler), the new accessory is available with a lowered coaxial 90° bend.

 

For more information, download the following documentation:

 

 

NEW COMBUSTION GROUP

The Prime combines the performance of the stainless steel exchanger with the advantages of a new generation burner integrated with an innovative cold closing door.

 

 

 

The new cylindrical burner ensures greater thermal and acoustic comfort, and reduced NOx and CO emissions thanks to greater flame stability. The new cold door reduces losses by 75% with surface temperatures below 20°C, guaranteeing significant savings in stand-by and during operation, speeding up maintenance, as there is no need to wait
let it cool down.

Baxi Prime 30 Condensing Gas Boiler Complete With LPG Or Methane Fume Kit - New Erp Model

Product form

Easy to use thanks to the control panel equipped with knobs and backlit LCD display • Easy installation thanks to... Read more

€912,00 Incl. VAT

    Description

    Easy to use thanks to the control panel equipped with knobs
    and backlit LCD display
    • Easy installation thanks to ultra-compact dimensions
    (700x395x279 mm – including knobs) and low weight (26 kg)
    • Easy replacement of conventional boilers thanks to central flue gas outlet
    • Modulation range 1:5 greater efficiency and silence
    • High efficiency circulation pump
    • Arrangement for combination with the Baxi integrated solar system
    • Ø 80 double exhaust as standard
    • Connection to rigid and flexible Ø 50 mm exhaust pipe: solutions for restoring flues, total length (exhaust +
    suction) 40 meters
    • Connection to pressurized collective flues
    Boilers running on methane that can be converted to LPG and propane air by means of a specific regulation (conversion kit not necessary )




    • TECHNICAL FEATURES
    • Installation type: B23-B23P-B33-C13-C33-C43-C53-C63-C83-C93
    • DHW nominal heat input: 20.9 kW
    • Sanitary nominal thermal power: 30 kW
    • Nominal heating heat input: 24.7 kW
    • Heating rated thermal power 80/60°C: 24 kW
    • Heating rated thermal power 50/30°C: 26.1 kW
    • Reduced thermal power 80/60°C : 5.6 kW
    • Reduced thermal power 50/30°C: 6 kW
    • Efficiency at 30%: 105.8%
    • Nominal efficiency 80/60°C: 97.5%
    • Nominal efficiency 50/30°C: 105.8%
    • Seasonal space heating energy efficiency class: A
    • Seasonal energy efficiency class of the sanitary fixture: A
    • Water heating – Load profile: XL
    • NOx class 5
    • Domestic hot water production: ∆T 25°C: 13.8 l/min
    • Category II2HM3B/P appliance operating on gas type G20 – G230 – G30 – G31
    • Electronic ignition with flame ionization control
    • Degree of protection: IPX5D
    • Primary water/gas coil exchanger in AISI 316L stainless steel
    • Secondary water/water exchanger in stainless steel
    • Electric 3-way diverter valve
    • Modulating fan with electronic speed variation
    • Automatic by-pass on the heating circuit
    • Digital and analog pressure gauge on the heating circuit
    • Heating expansion tank with capacity 7 l and preload 0.8 bar
    • High efficiency ErP full modulation circulation pump with built-in deaerator
    • Hall effect DHW flowmeter for detecting hot water withdrawal
    • DHW operation with minimum water pressure of 0.15 bar and minimum flow rate of 2 l/min.
    • Inspectable filter on loading water inlet
    • Primary circuit safety valve at 3 bar
    • Heating water temperature adjustment range: 25÷80°C
    • Domestic water temperature adjustment range (in the case of combination with a boiler): 35÷60°C
    • Minimum operating temperature: – 5°C
    • Dimensions hxwxd: 700 x 395 x 279 mm
    • Weight 26kg
    • CONTROL SYSTEM
    • Temperature control using NTC probes
    • Pump post-circulation in heating function
    • Safety thermostat against overheating of the water/fumes exchanger
    • Hydraulic pressure switch which blocks the gas in case of water shortage
    • Pump electronic control blocked
    • Pump anti-blocking system and 3-way valve which intervenes every 24 hours
    • NTC safety probe against fume overheating
    • Total antifreeze device which intervenes with temperatures below 5°C
    • Electronic thermometer
    • Display of heating circuit pressure on control panel

     

    THE ADVANTAGES OF PRIME

    EASY TO INSTALL

    The ultra-compact dimensions 700x395x279 mm and the weight of just 26 kg reduce installation time. The new Prime has the same distance between centers of the hydraulic connections of the conventional BAXI boilers to be replaced. Front access to the electrical connection also speeds up connection times.
    The fixing bracket supplied as standard and the visible hooks facilitate wall mounting.

     

     

     

    LOWER ENERGY CONSUMPTION

    Thanks to the condensing technology, the high efficiency pump and the series of modulating room thermostats available as an accessory.
    The new regulation 7129-3:2015 prescribes the possibility of creating collective flues in positive pressure only for type C condensing appliances.
    It is possible to connect to a collective flue in positive pressure only appliances declared suitable by the manufacturer for this application and equipped with a non-return device (clapet), designed to prevent the combustion products from flowing out through appliances connected and temporarily switched off; the smoke non-return valve is an integral part of the appliance.

     

     

     

     

    THE REGULATION 7129-3:2015

    Regulation 7129-3:2015 prescribes the possibility of creating collective flues in positive pressure only
    for type C condensing appliances.
    Only devices declared suitable can be connected to a positive pressure collective flue
    by the manufacturer for this application and equipped with a non-return device (clapet), designed to prevent the products from
    combustion to flow through appliances connected and momentarily switched off; the smoke non-return valve is part
    component of the appliance.

     

     

    • CLAPET (SMOKE NON-RETURN VALVE)

    Included in the duct downstream of the air-gas group fan.

     

     

     

     

     

    • CONNECTED TO COLLECTIVE PRESSURIZED FLUES

    Thanks to the integrated flue non-return valve (clapet), Prime is designed for connection to pressurized collective flues.

     

     

     

     

     

     

     

     

     

     

     

     

     

    SMOKE PIPES Ø50 MM

    Possibility of restoring flues with Ø50 mm exhaust hose (up to 40m of exhaust)

     

     

    FLEXIBILITY IN THE REPLACEMENT

    Easy replacement of old standard boilers, thanks to the central flue outlet and the separate adjustable outlet supplied as standard.

     

    The Ø 60/100 coaxial drain is available as an accessory that can be combined with a pipe extension and a 60/100 diameter 90° elbow (360° adjustable).

     

    To facilitate replacement in installations where space is limited (flue gas outlet at the rear of the boiler), the new accessory is available with a lowered coaxial 90° bend.

     

    For more information, download the following documentation:

     

     

    NEW COMBUSTION GROUP

    The Prime combines the performance of the stainless steel exchanger with the advantages of a new generation burner integrated with an innovative cold closing door.

     

     

     

    The new cylindrical burner ensures greater thermal and acoustic comfort, and reduced NOx and CO emissions thanks to greater flame stability. The new cold door reduces losses by 75% with surface temperatures below 20°C, guaranteeing significant savings in stand-by and during operation, speeding up maintenance, as there is no need to wait
    let it cool down.
    Data sheetData sheet
    • peso: 35.0 kg
    • classe energetica produzione acs: A
    • classe energetica riscaldamento: A
    • gas: Methane/LPG
    • marca: BAXI
    • metri quadri : 220
    • modello: CALD_1992333
    • potenza in kw: 30
    • potenza nominale: 30
    • superficie riscaldabile mq: 220
    Icon for coinShipping cost

    Shipping costs vary according to the weight of the order.

    Consult the tables with the weights for Italy and for the smaller islands and disadvantaged areas.

    Warranty detailsWarranty details

    Pursuant to art. 63 of the Consumer Code, the risk of loss and damage to the goods, for reasons not attributable to the seller, is transferred to the consumer when the latter, or a third party designated by him and other than the carrier, physically comes into possession of goods. However, the risk is transferred to the consumer as soon as the goods are delivered to the carrier. The Customer who at the time of purchase has decided to make use of the extra insurance service for the transport of the purchased goods, in the event that he finds anomalies at the time of delivery (packaging damaged or otherwise altered in the closing seals, damaged product or scratched, missing one or more packages ordered), must accept the product by writing on the document provided by the carrier: "WE ACCEPT WITH RESERVE" + description of the anomaly found. In fact, to enforce the insurance coverage it is not sufficient to note "ACCEPTED WITH RESERVE" or "ACCEPTED WITH SUBJECT TO INSPECTION", BUT the reason for the reservation must be explained in detail. If the package or the product should show visible damage, scratches or any other type of anomaly and the courier should refuse to affix a specific reserve, the goods must be refused and the incident reported immediately (and in any case in a timely manner) to the Customer Service of Decidiprice srl. In any case, without prejudice to the seller's obligations in terms of legal guarantee pursuant to articles 128 et seq. of the Consumer Code, Decidiprezzo srl will not be held responsible for any anomalies found in the state of the product, after delivery, if the Customer, in the presence of an anomaly, has accepted the package without making a specific reservation (in the corrected above). Any damage or anomalies must be reported to Customer Service by email to postvendita@climaconvenienza.it. The request must be forwarded no later than 8 calendar days from receipt of the goods. Any notification beyond the aforementioned terms will not be taken into consideration.

    Customer service detailsCustomer service details

    Our customer service department is dedicated to providing support to our customers with any problems or questions they may have before or after purchasing our products.

    Use the direct communication channel to speak to one of our operators, or send us an email to one of the addresses listed on the contact us page.

    Our customer service team is made up of highly trained professionals who are always ready to help customers solve any problem or answer any question quickly and efficiently. We are committed to ensuring maximum customer satisfaction and providing the highest quality after-sales service. So if you need any assistance, don't hesitate to contact us; we will be happy to help you in any way we can.

    Recensioni di CaldaieMurali.it

    feedaty-widget

    Latest Products Viewed

    Login

    Forgot your password?

    Don't have an account yet?
    Create account