ARISTON EGIS PLUS 24 CF EU METHANE BOILER - NEW ErP 2016: Compact wall-mounted boiler with open chamber and natural draft.

Technical specifications

Product code: 33001807

Energy label specifications according to the European ErP directive

Class C heating energy efficiency

Sanitaryware energy efficiencyprofilXL Class B

Characteristics of heating/sanitary exercises:

For heating and domestic hot waterÿ

Open chamber with natural draft

Nominal heat input in heatingmax/min kW 25.8/11

Heating max/min heat output (80øC-60øC) kW 23.7/9.9ÿ

Efficiency at nominal heat input % 91.9

Efficiency 30% of nominal flowÿ% 91.2

Performance stars (dir. 92/42/EEC)

Heating max/min temperatureÿøC 35/ 85ÿ

Sanitary max/min temperatureøC 36/60

Specific flow rate in sanitaryware (10 min. with T=30øC) litres/min 11.3

Quantity of hot water T=25øC litres/min 13.6ÿ

Quantity of hot water T=35øC litres/min 9.7

Supply voltage/frequency V/Hz 230/50ÿ

Degrees of protection for electrical systemsIP X4Dÿ

Dimensions (H x W x D) mm 745/400/315ÿ

METHANE power supply

Features list

Egis Plus

Conventional compact wall-mounted boiler

The wall-mounted boilerÿEgis Plusÿ is the solution for domestic comfort signed by Ariston; it stands out for its installation flexibility, covered hydraulic connections and dimensions. It can be integrated into solar systems and, thanks to the easy front access system, allows extreme maintainability without the need for tools.

It is available in the heating and domestic hot water production version: 24 kW (open chamber).

Characteristics:

Digital multifunction display

Continuous modulation high efficiency circulator

Predisposition for on-off thermoregulation

Predisposition solar systems natural circulation

Self-diagnosis system by code

Mono-temperature zone management

Primary heat exchanger in copper

Double exchanger technology

Integral minimum pressure switch

Cold water inlet filters and heating return

High efficiency circulator with continuous modulation:

It allows automatic adaptation of the power based on the system temperature, guaranteeing boiler performance and reducing electricity consumption.

Optimizing thermal efficiency.ÿ

Optimization of comfort with constant temperature.ÿ

Maximum silence.

Ecodesign Directive:

In fact, after very long negotiations, the ÿEcodesign regulationÿ was approved, which introduces a new energy labeling on minimum efficiency standards for boilers.ÿIn particular, an energy classification from A+ to G is envisaged for space heating appliances and from A to G for appliances for the production of domestic hot water. ÿHence the obligation to installÿonly condensing boilers, heat generators capable of recovering a large part of the latent heat contained in the fumes which, otherwise, would be dispersed in the chimneyÿas occurs in traditional boilers. The recovered heat is transferred to the heating system, making it possible to achieve a yield of 106% with 92% of the traditional boiler and 84/85% of an oldÿÿtraditional generator.ÿThe installation obligation concerns manufacturers of boilers which will no longer be able to place on the market non-condensing starting from 26 September 2015. This means that starting from this date, anyone who wants to install a boiler in their own home will have to install only condensing models. Only one particular type of non-condensing boiler will continue to be produced which is technically called open room? to be installedÿ when it is not possible to replace an old boiler with a condensing boilerÿdue to problems related to the collective flueÿof some multi-family buildings.

Products for heating water and the environment represent around 30% of the world's energy consumption in Europe.ÿ

Designing eco-friendly products and promoting high performance technologies to end users in 2020 will lead to:

An annual energy saving equivalent to 56 million tons of oil, quantifiable to the savings obtained if the water and environmental heating systems of two large nations like Italy were deactivated.

As of 26 September 2015, the ErP regulation and ÿenergy labelingÿwill be applied in Europe to water and space heating products (boilers, heat pumps, micro-CHP devices, water heaters, and hot water storage tanks) u.

There are different labels, based on the type and function of the product (only room water heating of both, and in this case the label must bear both classifications).

In addition to the energy class, the label provides other information that could be useful for understanding which product has the least environmental impact (for example power and consumption in different climatic zones, noise levels, etc.).

It is possible to increase the energy efficiency of hot water production and space heating by connecting several products and accessories in one system. In this case it is necessary to prepare a system label in addition to that relating to the single product

Warranty

All products for sale on our site are new and packed. The guarantee on this article is 24 months from the date of purchase.

Boiler Ariston Egis Plus 24 Cf Eu Methane - Erp

Product form

Overview ARISTON EGIS PLUS 24 CF EU METHANE BOILER - NEW ErP 2016: Compact wall-mounted boiler with open chamber and... Read more

€388,00 Incl. VAT

    Description

    Overview

    ARISTON EGIS PLUS 24 CF EU METHANE BOILER - NEW ErP 2016: Compact wall-mounted boiler with open chamber and natural draft.

    Technical specifications

    Product code: 33001807

    Energy label specifications according to the European ErP directive

    Class C heating energy efficiency

    Sanitaryware energy efficiencyprofilXL Class B

    Characteristics of heating/sanitary exercises:

    For heating and domestic hot waterÿ

    Open chamber with natural draft

    Nominal heat input in heatingmax/min kW 25.8/11

    Heating max/min heat output (80øC-60øC) kW 23.7/9.9ÿ

    Efficiency at nominal heat input % 91.9

    Efficiency 30% of nominal flowÿ% 91.2

    Performance stars (dir. 92/42/EEC)

    Heating max/min temperatureÿøC 35/ 85ÿ

    Sanitary max/min temperatureøC 36/60

    Specific flow rate in sanitaryware (10 min. with T=30øC) litres/min 11.3

    Quantity of hot water T=25øC litres/min 13.6ÿ

    Quantity of hot water T=35øC litres/min 9.7

    Supply voltage/frequency V/Hz 230/50ÿ

    Degrees of protection for electrical systemsIP X4Dÿ

    Dimensions (H x W x D) mm 745/400/315ÿ

    METHANE power supply

    Features list

    Egis Plus

    Conventional compact wall-mounted boiler

    The wall-mounted boilerÿEgis Plusÿ is the solution for domestic comfort signed by Ariston; it stands out for its installation flexibility, covered hydraulic connections and dimensions. It can be integrated into solar systems and, thanks to the easy front access system, allows extreme maintainability without the need for tools.

    It is available in the heating and domestic hot water production version: 24 kW (open chamber).

    Characteristics:

    Digital multifunction display

    Continuous modulation high efficiency circulator

    Predisposition for on-off thermoregulation

    Predisposition solar systems natural circulation

    Self-diagnosis system by code

    Mono-temperature zone management

    Primary heat exchanger in copper

    Double exchanger technology

    Integral minimum pressure switch

    Cold water inlet filters and heating return

    High efficiency circulator with continuous modulation:

    It allows automatic adaptation of the power based on the system temperature, guaranteeing boiler performance and reducing electricity consumption.

    Optimizing thermal efficiency.ÿ

    Optimization of comfort with constant temperature.ÿ

    Maximum silence.

    Ecodesign Directive:

    In fact, after very long negotiations, the ÿEcodesign regulationÿ was approved, which introduces a new energy labeling on minimum efficiency standards for boilers.ÿIn particular, an energy classification from A+ to G is envisaged for space heating appliances and from A to G for appliances for the production of domestic hot water. ÿHence the obligation to installÿonly condensing boilers, heat generators capable of recovering a large part of the latent heat contained in the fumes which, otherwise, would be dispersed in the chimneyÿas occurs in traditional boilers. The recovered heat is transferred to the heating system, making it possible to achieve a yield of 106% with 92% of the traditional boiler and 84/85% of an oldÿÿtraditional generator.ÿThe installation obligation concerns manufacturers of boilers which will no longer be able to place on the market non-condensing starting from 26 September 2015. This means that starting from this date, anyone who wants to install a boiler in their own home will have to install only condensing models. Only one particular type of non-condensing boiler will continue to be produced which is technically called open room? to be installedÿ when it is not possible to replace an old boiler with a condensing boilerÿdue to problems related to the collective flueÿof some multi-family buildings.

    Products for heating water and the environment represent around 30% of the world's energy consumption in Europe.ÿ

    Designing eco-friendly products and promoting high performance technologies to end users in 2020 will lead to:

    An annual energy saving equivalent to 56 million tons of oil, quantifiable to the savings obtained if the water and environmental heating systems of two large nations like Italy were deactivated.

    As of 26 September 2015, the ErP regulation and ÿenergy labelingÿwill be applied in Europe to water and space heating products (boilers, heat pumps, micro-CHP devices, water heaters, and hot water storage tanks) u.

    There are different labels, based on the type and function of the product (only room water heating of both, and in this case the label must bear both classifications).

    In addition to the energy class, the label provides other information that could be useful for understanding which product has the least environmental impact (for example power and consumption in different climatic zones, noise levels, etc.).

    It is possible to increase the energy efficiency of hot water production and space heating by connecting several products and accessories in one system. In this case it is necessary to prepare a system label in addition to that relating to the single product

    Warranty

    All products for sale on our site are new and packed. The guarantee on this article is 24 months from the date of purchase.

    Data sheetData sheet
    • peso: 40.0 kg
    • marca: Ariston
    • modello: CALD_404
    Icon for coinShipping cost

    Shipping costs vary according to the weight of the order.

    Consult the tables with the weights for Italy and for the smaller islands and disadvantaged areas.

    Warranty detailsWarranty details

    Pursuant to art. 63 of the Consumer Code, the risk of loss and damage to the goods, for reasons not attributable to the seller, is transferred to the consumer when the latter, or a third party designated by him and other than the carrier, physically comes into possession of goods. However, the risk is transferred to the consumer as soon as the goods are delivered to the carrier. The Customer who at the time of purchase has decided to make use of the extra insurance service for the transport of the purchased goods, in the event that he finds anomalies at the time of delivery (packaging damaged or otherwise altered in the closing seals, damaged product or scratched, missing one or more packages ordered), must accept the product by writing on the document provided by the carrier: "WE ACCEPT WITH RESERVE" + description of the anomaly found. In fact, to enforce the insurance coverage it is not sufficient to note "ACCEPTED WITH RESERVE" or "ACCEPTED WITH SUBJECT TO INSPECTION", BUT the reason for the reservation must be explained in detail. If the package or the product should show visible damage, scratches or any other type of anomaly and the courier should refuse to affix a specific reserve, the goods must be refused and the incident reported immediately (and in any case in a timely manner) to the Customer Service of Decidiprice srl. In any case, without prejudice to the seller's obligations in terms of legal guarantee pursuant to articles 128 et seq. of the Consumer Code, Decidiprezzo srl will not be held responsible for any anomalies found in the state of the product, after delivery, if the Customer, in the presence of an anomaly, has accepted the package without making a specific reservation (in the corrected above). Any damage or anomalies must be reported to Customer Service by email to postvendita@climaconvenienza.it. The request must be forwarded no later than 8 calendar days from receipt of the goods. Any notification beyond the aforementioned terms will not be taken into consideration.

    Customer service detailsCustomer service details

    Our customer service department is dedicated to providing support to our customers with any problems or questions they may have before or after purchasing our products.

    Use the direct communication channel to speak to one of our operators, or send us an email to one of the addresses listed on the contact us page.

    Our customer service team is made up of highly trained professionals who are always ready to help customers solve any problem or answer any question quickly and efficiently. We are committed to ensuring maximum customer satisfaction and providing the highest quality after-sales service. So if you need any assistance, don't hesitate to contact us; we will be happy to help you in any way we can.

    Reviews of CaldaieMurali.it

    feedaty-widget

    Latest Products Viewed

    Login

    Forgot your password?

    Don't have an account yet?
    Create account