Chiller heat pumps
Ferroli Air-Water Reversible Split Heat Pump Inverter Ferroli Omnia St 3.2 14 System With Single-Phase R-32 Electrical Integration With Control Included
ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS FREE FIRST START-UP Technical features Model : OMNIA S 3.2 14 Product code : 0XHTESWA Command included Optional accessories CONNECT CRP remote control Performance Heating Useful power in heating with water set at 35° C: 14.5 kW Useful power in heating with water set at 45° C: 14.1 kW Useful power in heating with water set at 55° C: 13.8 kW Absorbed power with water set at 35° C: 3.15 kW Absorbed power with water set at 45° C: 3.92 kW Absorbed power with water set at 55° C: 4.68 kW Water flow rate with water set at 35° C : 2494 l/h Water flow rate with water set at 45° C : 2425 /h Water flow rate with water set at 55° C : 1484 l/h Cooling down Useful power in cooling with water set at 7 °C: 12.4 kW Useful power in cooling with water set at 18 °C: 12.9 kW Absorbed power with water set at 7° C: 4.96 kW Absorbed power with water set at 18° C: 3.49 kW Water flow rate with water set at 7° C : 2133 l/h Water flow rate with water set at 18° C : 2322 l/h External unit technical data Compressor type : Twin Rotary DC Number of compressors : 1 Number of cooling circuits: 1 Type of fans : DC axial Number of fans : 1 Sound power level in heating : 56 ~ 65 dB(A) Sound power level in cooling : 56 ~ 65 dB(A) Liquid pipe diameter : 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Maximum piping length: 30 m Maximum pipe height difference: 20 m Indoor unit technical data Exchanger type : Brazed stainless steel plates Expansion vessel volume: 10 litres Water safety valve setting: 3 bar Minimum system water content: 40 litres System piping diameter: 1" gas F DHW piping diameter: 3/4" gas F Liquid pipe diameter : 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Electrical data Power supply (V,Hz, Ø) : 220~240/50/1 Refrigerant gas : R32 Dimensions and weight External unit dimensions (WxHxD): 1118x865x523 mm Outdoor unit weight: 96.0 Kg Internal unit dimensions (WxHxD): 595x1860x700 mm 5 years without worries Ferroli OMNIA ST 3.2 Air-water reversible heat pumps for split installation, with integrated DHW storage Efficiency marries comfort for integrated storage OMNIA ST 3.2 is the evolution of OMNIA S 3.2 and is part of the new range of Full Inverter R32 split heat pumps by Ferroli. When we speak of "split" we mean that the refrigerant circuit is divided between the two units, the external and the internal one. The outdoor unit contains the heart of the refrigerant circuit, from the compressor to the fan with the air side exchanger, which is connected to the refrigerant gas pipes towards the indoor unit. The indoor unit, on the other hand, contains the heart of the generator's hydraulic circuit with all the main pre-installed components, such as the high-efficiency circulator and the expansion tank, to safely allow quick and practical installation. The OMNIA ST 3.2 differ from the OMNIA S 3.2 in having integrated a storage tank for domestic hot water directly into the internal unit. This accumulation is 190L for sizes from 4 to 10, while it is 240L for uppers, from 12 to 16T. But that's not all, OMNIA ST 3.2 can be customized according to your needs, with an 18L inertial kit, kit for solar integration on the storage tank or with a kit for managing 2 different zones, classic direct and mixed, in case where we need 2 different temperatures on the terminals in the house Thanks to its wide operating range , among the widest on the market, OMNIA ST 3.2 works down to -25°C outside and produces hot water up to 65°C in nominal conditions. The new Full Inverter concept by Ferroli uses DC inverter modulations on the 3 main energy-intensive components of the machine, i.e. compressor, fan and pump. This makes it possible to modulate the power supplied by finely tracking the thermal load and allowing the user very high efficiencies and important energy savings . Furthermore, Ferroli's Full Inverter concept allows for the inrush currents to be reduced, avoiding sudden changes to the grid and guaranteeing a longer useful life for the components. With sound levels among the lowest on the market , OMNIA ST 3.2 is able to satisfy all system requirements, but can easily be integrated with a Ferroli boiler. The indoor unit, the heart of hydraulic distribution If the outdoor unit contains the heart of the refrigerant circuit, the indoor unit contains the heart of the water circuit. OMNIA ST 3.2 is much more than an exchanger with a pump. The hydronic module includes all the main components of the system and can be customized according to the user's needs. Stainless steel plate heat exchanger, pressure gauge and sensors, expansion tank, safety valve, automatic vent and brushless DC circulator are just some of the components you will find inside The control system The user interface has been equipped with capsense technology with 2.8” graphic display, which allows the user to interact with the product easily and extremely simply Modbus protocol It can be interfaced to BMS/BACS automation and management systems Heating and cooling Full Inverter modulation finely follows the desired setpoints, with the possibility of setting heating and cooling climatic curves, further optimizing consumption for the user Domestic hot water production When the DHW temperature probe calls the machine, it automatically switches to the domestic hot water tank with dedicated DHW set point. 3-way diverter valve supplied as standard Smart Grid input from photovoltaic and grid Digital Smart Grid inputs for the management of an input from the photovoltaic system and from the electricity grid. These allow you to optimize consumption and bill costs DHW tank electrical resistance The DHW electrical integration serves as integration, anti-legionella or reserve source in the event of an anomaly Fast DHW Priority to DHW production to bring the storage tank to the set point in the shortest possible time Anti-legionella function Allows you to set anti-legionella weekly cycles Silent mode Reduces the frequency of the compressor and the speed of the fan, so as to significantly reduce noise. Programmable on time slots ON/OFF From external contact. Activation and deactivation via an external contact, for example from a zone thermostat Hot / cold From external contacts. Summer/winter switching signal from outside, for example from the zone thermostat ECO function Dedicated setpoint for " Eco " operation. Settable with daily time band Anti-freeze protection Heat pump operation with circulator ON and possible electric booster The brand new Connect CRP and Connect CRP Zone The on-board interface communicates easily with the new Connect CRP intelligent systems, which can manage up to 8 thermostats divided into 2 zones, one direct and one mixed . Connect CRP is the brand new remote controller accessible via APP , available for both iOS and Android . The Connect CRP Zone, on the other hand, is a zone thermostat that communicates via RF with the Connect CRP. It can be placed in a classic 502 box, or left stand-alone on its practical table feet Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€7.200,00
Ferroli Air-Water Reversible Split Heat Pump Inverter Ferroli Omnia St 3.2 12t System With Three-Phase R-32 Electrical Integration With Control Included
ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS FREE FIRST START-UP Technical features Model : OMNIA S 3.2 12T Product code : 0XHUCSWA Command included Optional accessories CONNECT CRP remote control Performance Heating Useful power in heating with water set at 35° C: 12.1 kW Useful power in heating with water set at 45° C: 12.3 kW Useful power in heating with water set at 55° C: 11.9 kW Absorbed power with water set at 35° C: 2.44 kW Absorbed power with water set at 45° C: 3.32 kW Absorbed power with water set at 55° C: 3.90 kW Water flow rate with water set at 35° C : 2081 l/h Water flow rate with water set at 45° C : 2116 /h Water flow rate with water set at 55° C : 1279 l/h Cooling down Useful power in cooling with water set at 7 °C: 11.5 kW Useful power in cooling with water set at 18 °C: 12.0 kW Absorbed power with water set at 7° C: 4.18 kW Absorbed power with water set at 18° C: 3.04 kW Water flow rate with water set at 7° C : 1978 l/h Water flow rate with water set at 18° C : 2064 l/h External unit technical data Compressor type : Twin Rotary DC Number of compressors : 1 Number of cooling circuits: 1 Type of fans : DC axial Number of fans : 1 Sound power level in heating : 56 ~ 65 dB(A) Sound power level in cooling : 56 ~ 65 dB(A) Liquid pipe diameter : 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Maximum piping length: 30 m Maximum pipe height difference: 20 m Indoor unit technical data Exchanger type : Brazed stainless steel plates Expansion vessel volume: 10 litres Water safety valve setting: 3 bar Minimum system water content: 40 litres System piping diameter: 1" gas F DHW piping diameter: 3/4" gas F Liquid pipe diameter : 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Electrical data Power supply (V,Hz, Ø) : 380~415/50/3 Refrigerant gas : R32 Dimensions and weight External unit dimensions (WxHxD): 1118x865x523 mm Outdoor unit weight: 112.0 Kg Internal unit dimensions (WxHxD): 595x1860x700 mm 5 years without worries Ferroli OMNIA ST 3.2 Air-water reversible heat pumps for split installation, with integrated DHW storage Efficiency marries comfort for integrated storage OMNIA ST 3.2 is the evolution of OMNIA S 3.2 and is part of the new range of Full Inverter R32 split heat pumps by Ferroli. When we speak of "split" we mean that the refrigerant circuit is divided between the two units, the external and the internal one. The outdoor unit contains the heart of the refrigerant circuit, from the compressor to the fan with the air side exchanger, which is connected to the refrigerant gas pipes towards the indoor unit. The indoor unit, on the other hand, contains the heart of the generator's hydraulic circuit with all the main pre-installed components, such as the high-efficiency circulator and the expansion tank, to safely allow quick and practical installation. The OMNIA ST 3.2 differ from the OMNIA S 3.2 in having integrated a storage tank for domestic hot water directly into the internal unit. This accumulation is 190L for sizes from 4 to 10, while it is 240L for uppers, from 12 to 16T. But that's not all, OMNIA ST 3.2 can be customized according to your needs, with an 18L inertial kit, kit for solar integration on the storage tank or with a kit for managing 2 different zones, classic direct and mixed, in case where we need 2 different temperatures on the terminals in the house Thanks to its wide operating range , among the widest on the market, OMNIA ST 3.2 works down to -25°C outside and produces hot water up to 65°C in nominal conditions. The new Full Inverter concept by Ferroli uses DC inverter modulations on the 3 main energy-intensive components of the machine, i.e. compressor, fan and pump. This makes it possible to modulate the power supplied by finely tracking the thermal load and allowing the user very high efficiencies and important energy savings . Furthermore, Ferroli's Full Inverter concept allows for the inrush currents to be reduced, avoiding sudden changes to the grid and guaranteeing a longer useful life for the components. With sound levels among the lowest on the market , OMNIA ST 3.2 is able to satisfy all system requirements, but can easily be integrated with a Ferroli boiler. The indoor unit, the heart of hydraulic distribution If the outdoor unit contains the heart of the refrigerant circuit, the indoor unit contains the heart of the water circuit. OMNIA ST 3.2 is much more than an exchanger with a pump. The hydronic module includes all the main components of the system and can be customized according to the user's needs. Stainless steel plate heat exchanger, pressure gauge and sensors, expansion tank, safety valve, automatic vent and brushless DC circulator are just some of the components you will find inside The control system The user interface has been equipped with capsense technology with 2.8” graphic display, which allows the user to interact with the product easily and extremely simply Modbus protocol It can be interfaced to BMS/BACS automation and management systems Heating and cooling Full Inverter modulation finely follows the desired setpoints, with the possibility of setting heating and cooling climatic curves, further optimizing consumption for the user Domestic hot water production When the DHW temperature probe calls the machine, it automatically switches to the domestic hot water tank with dedicated DHW set point. 3-way diverter valve supplied as standard Smart Grid input from photovoltaic and grid Digital Smart Grid inputs for the management of an input from the photovoltaic system and from the electricity grid. These allow you to optimize consumption and bill costs DHW tank electrical resistance The DHW electrical integration serves as integration, anti-legionella or reserve source in the event of an anomaly Fast DHW Priority to DHW production to bring the storage tank to the set point in the shortest possible time Anti-legionella function Allows you to set anti-legionella weekly cycles Silent mode Reduces the frequency of the compressor and the speed of the fan, so as to significantly reduce noise. Programmable on time slots ON/OFF From external contact. Activation and deactivation via an external contact, for example from a zone thermostat Hot / cold From external contacts. Summer/winter switching signal from outside, for example from the zone thermostat ECO function Dedicated setpoint for " Eco " operation. Settable with daily time band Anti-freeze protection Heat pump operation with circulator ON and possible electric booster The brand new Connect CRP and Connect CRP Zone The on-board interface communicates easily with the new Connect CRP intelligent systems, which can manage up to 8 thermostats divided into 2 zones, one direct and one mixed . Connect CRP is the brand new remote controller accessible via APP , available for both iOS and Android . The Connect CRP Zone, on the other hand, is a zone thermostat that communicates via RF with the Connect CRP. It can be placed in a classic 502 box, or left stand-alone on its practical table feet Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€7.450,00
Ferroli Air-Water Reversible Split Heat Pump Inverter Ferroli Omnia St 3.2 12 System With Single-Phase R-32 Electrical Integration With Control Included
ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS FREE FIRST START-UP Technical features Model : OMNIA S 3.2 12 Product code : 0XHTCSWA Command included Optional accessories CONNECT CRP remote control Performance Heating Useful power in heating with water set at 35° C: 12.1 kW Useful power in heating with water set at 45° C: 12.3 kW Useful power in heating with water set at 55° C: 11.9 kW Absorbed power with water set at 35° C: 2.44 kW Absorbed power with water set at 45° C: 3.32 kW Absorbed power with water set at 55° C: 3.90 kW Water flow rate with water set at 35° C : 2081 l/h Water flow rate with water set at 45° C : 2116 /h Water flow rate with water set at 55° C : 1279 l/h Cooling down Useful power in cooling with water set at 7 °C: 11.5 kW Useful power in cooling with water set at 18 °C: 12.0 kW Absorbed power with water set at 7° C: 4.18 kW Absorbed power with water set at 18° C: 3.04 kW Water flow rate with water set at 7° C : 1978 l/h Water flow rate with water set at 18° C : 2064 l/h External unit technical data Compressor type : Twin Rotary DC Number of compressors : 1 Number of cooling circuits: 1 Type of fans : DC axial Number of fans : 1 Sound power level in heating : 56 ~ 65 dB(A) Sound power level in cooling : 56 ~ 65 dB(A) Liquid pipe diameter : 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Maximum piping length: 30 m Maximum pipe height difference: 20 m Indoor unit technical data Exchanger type : Brazed stainless steel plates Expansion vessel volume: 10 litres Water safety valve setting: 3 bar Minimum system water content: 40 litres System piping diameter: 1" gas F DHW piping diameter: 3/4" gas F Liquid pipe diameter : 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Electrical data Power supply (V,Hz, Ø) : 220~240/50/1 Refrigerant gas : R32 Dimensions and weight External unit dimensions (WxHxD): 1118x865x523 mm Outdoor unit weight: 96.0 Kg Internal unit dimensions (WxHxD): 595x1860x700 mm 5 years without worries Ferroli OMNIA ST 3.2 Air-water reversible heat pumps for split installation, with integrated DHW storage Efficiency marries comfort for integrated storage OMNIA ST 3.2 is the evolution of OMNIA S 3.2 and is part of the new range of Full Inverter R32 split heat pumps by Ferroli. When we speak of "split" we mean that the refrigerant circuit is divided between the two units, the external and the internal one. The outdoor unit contains the heart of the refrigerant circuit, from the compressor to the fan with the air side exchanger, which is connected to the refrigerant gas pipes towards the indoor unit. The indoor unit, on the other hand, contains the heart of the generator's hydraulic circuit with all the main pre-installed components, such as the high-efficiency circulator and the expansion tank, to safely allow quick and practical installation. The OMNIA ST 3.2 differ from the OMNIA S 3.2 in having integrated a storage tank for domestic hot water directly into the internal unit. This accumulation is 190L for sizes from 4 to 10, while it is 240L for uppers, from 12 to 16T. But that's not all, OMNIA ST 3.2 can be customized according to your needs, with an 18L inertial kit, kit for solar integration on the storage tank or with a kit for managing 2 different zones, classic direct and mixed, in case where we need 2 different temperatures on the terminals in the house Thanks to its wide operating range , among the widest on the market, OMNIA ST 3.2 works down to -25°C outside and produces hot water up to 65°C in nominal conditions. The new Full Inverter concept by Ferroli uses DC inverter modulations on the 3 main energy-intensive components of the machine, i.e. compressor, fan and pump. This makes it possible to modulate the power supplied by finely tracking the thermal load and allowing the user very high efficiencies and important energy savings . Furthermore, Ferroli's Full Inverter concept allows for the inrush currents to be reduced, avoiding sudden changes to the grid and guaranteeing a longer useful life for the components. With sound levels among the lowest on the market , OMNIA ST 3.2 is able to satisfy all system requirements, but can easily be integrated with a Ferroli boiler. The indoor unit, the heart of hydraulic distribution If the outdoor unit contains the heart of the refrigerant circuit, the indoor unit contains the heart of the water circuit. OMNIA ST 3.2 is much more than an exchanger with a pump. The hydronic module includes all the main components of the system and can be customized according to the user's needs. Stainless steel plate heat exchanger, pressure gauge and sensors, expansion vessel, safety valve, automatic vent and brushless DC circulator are just some of the components you will find inside The control system The user interface has been equipped with capsense technology with 2.8” graphic display, which allows the user to interact with the product easily and extremely simply Modbus protocol It can be interfaced to BMS/BACS automation and management systems Heating and cooling Full Inverter modulation finely follows the desired setpoints, with the possibility of setting heating and cooling climatic curves, further optimizing consumption for the user Domestic hot water production When the DHW temperature probe calls the machine, it automatically switches to the domestic hot water tank with dedicated DHW set point. 3-way diverter valve supplied as standard Smart Grid input from photovoltaic and grid Digital Smart Grid inputs for the management of an input from the photovoltaic system and from the electricity grid. These allow you to optimize consumption and bill costs DHW tank electrical resistance The DHW electrical integration serves as integration, anti-legionella or reserve source in the event of an anomaly Fast DHW Priority to DHW production to bring the storage tank to the set point in the shortest possible time Anti-legionella function Allows you to set anti-legionella weekly cycles Silent mode Reduces the frequency of the compressor and the speed of the fan, so as to significantly reduce noise. Programmable on time slots ON/OFF From external contact. Activation and deactivation via an external contact, for example from a zone thermostat Hot / cold From external contacts. Summer/winter switching signal from outside, for example from the zone thermostat ECO function Dedicated setpoint for " Eco " operation. Settable with daily time band Anti-freeze protection Heat pump operation with circulator ON and possible electric booster The brand new Connect CRP and Connect CRP Zone The on-board interface communicates easily with the new Connect CRP intelligent systems, which can manage up to 8 thermostats divided into 2 zones, one direct and one mixed . Connect CRP is the brand new remote controller accessible via APP , available for both iOS and Android . The Connect CRP Zone, on the other hand, is a zone thermostat that communicates via RF with the Connect CRP. It can be placed in a classic 502 box, or left stand-alone on its practical table feet Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€6.900,00
Ferroli Air-Water Reversible Heat Pump Inverter For Split Installation Ferroli Omnia S In 3.2 10 R-32 With Control Included
ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS FREE FIRST START-UP Technical features Model : OMNIA S IN 3.2 10 Product code : 0XHVASWA Command included Optional accessories Unpainted built-in cabinet 016092X0 Painted built-in cabinet 016093X0 DHW storage tank integration kit 012086W0 Energy efficiency Energy class in heating at 35° C: A+++ Energy class in heating at 55° C: A+++ ACS energy class: A Water profile declared in ACS : L SCOP heating with water set at 35 °C : 5.19 SEER cooling with water set at 7 °C: 5.96 Performance Heating Useful power in heating with water set at 35° C: 10.0 kW Useful power in heating with water set at 45° C: 10.0 kW Absorbed power with water set at 35° C: 2.02 kW Absorbed power with water set at 45° C: 2.67 kW Water flow rate with water set at 35° C : 1720 l/h Water flow rate with water set at 45° C : 1720 l/h Cooling down Useful power in cooling with water set at 7 °C: 8.20 kW Useful power in cooling with water set at 18 °C: 9.90 kW Absorbed power with water set at 7° C: 2.52 kW Absorbed power with water set at 18° C: 2.18 kW Water flow rate with water set at 7° C : 1410 l/h Water flow rate with water set at 18° C : 1703 l/h External unit technical data Compressor type : Twin Rotary DC Number of compressors : 1 Number of cooling circuits: 1 Type of fans : DC axial Number of fans : 1 Sound power level in heating : 60 dB(A) Sound power level in cooling : 60 dB(A) Maximum piping length: 30 m Maximum pipe height difference: 20 m Electrical data Power supply (V,Hz, Ø) : 220~240/50/1 Refrigerant gas : R32 Dimensions and weight External unit dimensions (WxHxD): 1118x865x523 mm Outdoor unit weight: 77.0 Kg 5 years without worries Ferroli OMNIA S IN 3.2 Reversible heat pumps for split installation, built-in solution Maximum architectural integration with a perfect All in One system OMNIA S IN 3.2 is the new split heat pump that completes the range of OMNIA S in R32 , offering performance with a reduced environmental impact, up to 75% lower than equivalent machines in R410A. The new Full Inverter concept by Ferroli uses DC inverter modulations on the 3 main energy-intensive components of the machine, namely the compressor, fan and pump . This makes it possible to modulate the power supplied by finely tracking the thermal load, guaranteeing the user very high efficiency and significant energy savings on the bill. But that's not all, OMNIA S IN 3.2 is the queen of Architectural Integration . Although inside it contains a 150-litre domestic hot water storage tank, the internal unit and the hydronic kits with circulators and bulky expansion vessels, the installation is so compact that everything fits into a practical cabinet or built-in wardrobe , disappearing. Furthermore, OMNIA S IN 3.2 can be customised : still inside the cabinet, it is possible to add a 30-litre inertial kit for heating/cooling water, integrate a solar thermal system directly into the domestic hot water storage tank and install various distribution groups , e.g. for direct and/or mixed zones The machine can then be managed with the integrated HMI interface or with the CONNECT CRP intelligent remote controller, which can also be accessed via the App . Finally, we can manage the rooms independently through the CONNECT CRP ZONEs , practical and design thermostats that will guarantee comfort in your rooms The control system The user interface has been equipped with capsense technology with 2.8” graphic display, which allows the user to interact with the product easily and extremely simply Modbus protocol It can be interfaced to BMS/BACS automation and management systems Heating and cooling Full Inverter modulation finely follows the desired setpoints, with the possibility of setting heating and cooling climatic curves, further optimizing consumption for the user Domestic hot water production When the DHW temperature probe calls the machine, it automatically switches to the domestic hot water tank with dedicated DHW set point. 3-way diverter valve supplied as standard Smart Grid input from photovoltaic and grid Digital Smart Grid inputs for the management of an input from the photovoltaic system and from the electricity grid. These allow you to optimize consumption and bill costs DHW tank electrical resistance The DHW electrical integration serves as integration, anti-legionella or reserve source in the event of an anomaly Fast DHW Priority to DHW production to bring the storage tank to the set point in the shortest possible time Anti-legionella function Allows you to set anti-legionella weekly cycles Silent mode Reduces the frequency of the compressor and the speed of the fan, so as to significantly reduce noise. Programmable on time slots ON/OFF From external contact. Activation and deactivation via an external contact, for example from a zone thermostat Hot / cold From external contacts. Summer/winter switching signal from outside, for example from the zone thermostat ECO function Dedicated setpoint for " Eco " operation. Settable with daily time band Anti-freeze protection Heat pump operation with circulator ON and possible electric booster The brand new Connect CRP and Connect CRP Zone The on-board interface communicates easily with the new Connect CRP intelligent systems, which can manage up to 8 thermostats divided into 2 zones, one direct and one mixed . Connect CRP is the brand new remote controller accessible via APP, available for both iOS and Android. The Connect CRP Zone, on the other hand, is a zone thermostat that communicates via RF with the Connect CRP. It can be placed in a classic 502 box, or left stand-alone on its practical table feet Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€5.650,00
Ferroli Air-Water Reversible Heat Pump Inverter For Split Installation Ferroli Omnia S In 3.2 08 R-32 With Control Included
ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS FREE FIRST START-UP Technical features Model : OMNIA S IN 3.2 08 Product code : 0XHV8SWA Command included Optional accessories Unpainted built-in cabinet 016092X0 Painted built-in cabinet 016093X0 DHW storage tank integration kit 012086W0 Energy efficiency Energy class in heating at 35° C: A+++ Energy class in heating at 55° C: A+++ ACS energy class: A Water profile declared in ACS : L SCOP heating with water set at 35 °C : 5.21 SEER cooling with water set at 7 °C: 5.83 Performance Heating Useful power in heating with water set at 35° C: 8.40 kW Useful power in heating with water set at 45° C: 8.30 kW Absorbed power with water set at 35° C: 1.63 kW Absorbed power with water set at 45° C: 2.16 kW Water flow rate with water set at 35° C : 1445 l/h Water flow rate with water set at 45° C : 1428 l/h Cooling down Useful power in cooling with water set at 7 °C: 7.45 kW Useful power in cooling with water set at 18 °C: 8.30 kW Absorbed power with water set at 7° C: 2.22 kW Absorbed power with water set at 18° C: 1.64 kW Water flow rate with water set at 7° C : 1281 l/h Water flow rate with water set at 18° C : 1428 l/h External unit technical data Compressor type : Twin Rotary DC Number of compressors : 1 Number of cooling circuits: 1 Type of fans : DC axial Number of fans : 1 Sound power level in heating : 59 dB(A) Sound power level in cooling : 60 dB(A) Maximum piping length: 30 m Maximum pipe height difference: 20 m Electrical data Power supply (V,Hz, Ø) : 220~240/50/1 Refrigerant gas : R32 Dimensions and weight External unit dimensions (WxHxD): 1118x865x523 mm Outdoor unit weight: 77.0 Kg 5 years without worries Ferroli OMNIA S IN 3.2 Reversible heat pumps for split installation, built-in solution Maximum architectural integration with a perfect All in One system OMNIA S IN 3.2 is the new split heat pump that completes the range of OMNIA S in R32 , offering performance with a reduced environmental impact, up to 75% lower than equivalent machines in R410A. The new Full Inverter concept by Ferroli uses DC inverter modulations on the 3 main energy-intensive components of the machine, namely the compressor, fan and pump . This makes it possible to modulate the power supplied by finely tracking the thermal load, guaranteeing the user very high efficiencies and significant energy savings on the bill. But that's not all, OMNIA S IN 3.2 is the queen of Architectural Integration . Although inside it contains a 150-litre domestic hot water storage tank, the internal unit and the hydronic kits with circulators and bulky expansion vessels, the installation is so compact that everything fits into a practical cabinet or built-in wardrobe , disappearing. Furthermore, OMNIA S IN 3.2 can be customised : still inside the cabinet, it is possible to add a 30-litre inertial kit for heating/cooling water, integrate a solar thermal system directly into the domestic hot water storage tank and install various distribution groups , e.g. for direct and/or mixed zones The machine can then be managed with the integrated HMI interface or with the CONNECT CRP intelligent remote controller, which can also be accessed via the App . Finally, we can manage the rooms independently through the CONNECT CRP ZONEs , practical and design thermostats that will guarantee comfort in your rooms The control system The user interface has been equipped with capsense technology with 2.8” graphic display, which allows the user to interact with the product easily and extremely simply Modbus protocol It can be interfaced to BMS/BACS automation and management systems Heating and cooling Full Inverter modulation finely follows the desired setpoints, with the possibility of setting heating and cooling climatic curves, further optimizing consumption for the user Domestic hot water production When the DHW temperature probe calls the machine, it automatically switches to the domestic hot water tank with dedicated DHW set point. 3-way diverter valve supplied as standard Smart Grid input from photovoltaic and grid Digital Smart Grid inputs for the management of an input from the photovoltaic system and from the electricity grid. These allow you to optimize consumption and bill costs DHW tank electrical resistance The DHW electrical integration serves as integration, anti-legionella or reserve source in the event of an anomaly Fast DHW Priority to DHW production to bring the storage tank to the set point in the shortest possible time Anti-legionella function Allows you to set anti-legionella weekly cycles Silent mode Reduces the frequency of the compressor and the speed of the fan, so as to significantly reduce noise. Programmable on time slots ON/OFF From external contact. Activation and deactivation via an external contact, for example from a zone thermostat Hot / cold From external contacts. Summer/winter switching signal from outside, for example from the zone thermostat ECO function Dedicated setpoint for " Eco " operation. Settable with daily time band Anti-freeze protection Heat pump operation with circulator ON and possible electric booster The brand new Connect CRP and Connect CRP Zone The on-board interface communicates easily with the new Connect CRP intelligent systems, which can manage up to 8 thermostats divided into 2 zones, one direct and one mixed . Connect CRP is the brand new remote controller accessible via APP, available for both iOS and Android. The Connect CRP Zone, on the other hand, is a zone thermostat that communicates via RF with the Connect CRP. It can be placed in a classic 502 box, or left stand-alone on its practical table feet Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€5.040,00
Ferroli Air-Water Reversible Heat Pump Inverter Ferroli Omnia S 3.2 14 Single-Phase R-32 With Control Included
ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS FREE FIRST START-UP Technical features Model : OMNIA S 3.2 14 Product code : 0XHKESWA Command included Optional accessories Unpainted built-in cabinet 016092X0 Painted built-in cabinet 016093X0 Optional accessories Unpainted built-in cabinet 016092X0 Painted built-in cabinet 016093X0 Energy efficiency Energy class in heating at 35° C: A+++ Energy class in heating at 55° C: A++ SCOP heating with water set at 35 °C : 4.72 SEER cooling with water set at 7 °C: 4.86 Performance Heating Useful power in heating with water set at 35° C: 14.5 kW Useful power in heating with water set at 45° C: 14.1 kW Useful power in heating with water set at 55° C: 13.8 kW Absorbed power with water set at 35° C: 3.15 kW Absorbed power with water set at 45° C: 3.92 kW Absorbed power with water set at 55° C: 4.68 kW Water flow rate with water set at 35° C : 2494 l/h Water flow rate with water set at 45° C : 2425 /h Water flow rate with water set at 55° C : 1484 l/h Cooling down Useful power in cooling with water set at 7 °C: 12.4 kW Useful power in cooling with water set at 18 °C: 12.9 kW Absorbed power with water set at 7° C: 4.96 kW Absorbed power with water set at 18° C: 3.49 kW Water flow rate with water set at 7° C : 2133 l/h Water flow rate with water set at 18° C : 2322 l/h External unit technical data Compressor type : Twin Rotary DC Number of compressors : 1 Number of cooling circuits: 1 Type of fans : DC axial Number of fans : 1 Sound power level in heating : 56 ~ 65 dB(A) Sound power level in cooling : 56 ~ 65 dB(A) Liquid pipe diameter : 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Maximum piping length: 30 m Maximum pipe height difference: 20 m Indoor unit technical data Exchanger type : Brazed stainless steel plates Expansion vessel volume: 10 litres Water safety valve setting: 3 bar Minimum system water content: 40 litres System piping diameter: 1" gas F DHW piping diameter: 3/4" gas F Liquid pipe diameter : 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Electrical data Power supply (V,Hz, Ø) : 220~240/50/1 Refrigerant gas : R32 Dimensions and weight External unit dimensions (WxHxD): 1118x865x523 mm Outdoor unit weight: 96.0 Kg Internal unit dimensions (WxHxD): 422x702x320 mm 5 years without worries Ferroli OMNIA S 3.2 Reversible heat pumps for split installation with DC inverter compressor Quietness, efficiency and design OMNIA S 3.2 is the new range of split heat pumps Full Inverter R32 by Ferroli. The range includes an Outdoor Unit with the heart of the refrigerant circuit, from the compressor to the fan with the air side exchanger, which is connected to the refrigerant gas pipes towards the Indoor Unit. The Indoor Unit, on the other hand, contains the heart of the hydraulic circuit of the generator with all the main pre-installed components, such as the high-efficiency circulator and the expansion vessel, to safely allow quick and practical installation The split installation of OMNIA S 3.2 , with only the gas pipes between the outdoor and indoor unit, is synonymous with security against any freezing problem, even at the coldest temperatures (down to -25°C) and in the absence of electricity. All units meet the most extreme winter and summer air conditioning requirements, they can in fact produce hot water up to 65°C , which makes them suitable for practically all heating systems, whether radiant, fan coil or radiator, including the production of domestic hot water (DHW), via an external boiler The new conception Full Inverter by Ferroli uses DC inverter modulations on the 3 main energy-intensive components of the machine, i.e. compressor, fan and pump. This allows you to modulate the power supplied by finely tracking the thermal load and allowing the user very high efficiencies and important energy savings . Also, the concept Full Inverter by Ferroli guarantees sound levels among the lowest on the market, avoiding sudden changes in the network and guaranteeing a longer useful life for the components. Indoor and outdoor unit of OMNIA 3.2 The Outdoor Unit contains the heart of the refrigerant circuit, while the Internal Unit the heart of the hydraulic circuit. They are connected to each other by pipes R32 ecological refrigerant gas , which has allowed us to combine high efficiency with a reduced environmental impact. Thanks to his GWP of 675 , about a third of the GWP of R410a, helps reduce CO2 equivalent emissions, the main causes of global warming The heat pumps use the Outdoor Unit to extract heat from the air outside the home and convey it to the water in your system, via an exchanger in the Indoor Unit. That's exactly why they manage to get such high efficiencies , exploiting so renewable the energy already present in the air outside the home The new conception Full Inverter by Ferroli then does the rest, tracking the thermal loads precisely and without waste (modulating the compressor, pump and fan), manages to achieve even greater efficiencies, guaranteeing important savings in bills , without stress on the components and with very low sound levels OMNIA S 3.2 it can be used both as the sole generator of the system and integrated with other sources such as a Ferroli boiler The control system The user interface has been equipped with capsense technology with 2.8” graphic display, which allows the user to interact with the product easily and extremely simply Modbus protocol It can be interfaced to BMS/BACS automation and management systems Heating and cooling Full Inverter modulation finely follows the desired setpoints, with the possibility of setting heating and cooling climatic curves, further optimizing consumption for the user Domestic hot water production When the DHW temperature probe calls the machine, it automatically switches to the domestic hot water tank with dedicated DHW set point. 3-way diverter valve supplied as standard Smart Grid input from photovoltaic and grid Digital Smart Grid inputs for the management of an input from the photovoltaic system and from the electricity grid. These allow you to optimize consumption and bill costs DHW tank electrical resistance The DHW electrical integration serves as integration, anti-legionella or reserve source in the event of an anomaly Fast DHW Priority to DHW production to bring the storage tank to the set point in the shortest possible time Anti-legionella function Allows you to set anti-legionella weekly cycles Silent mode Reduces the frequency of the compressor and the speed of the fan, so as to significantly reduce noise. Programmable on time slots ON/OFF From external contact. Activation and deactivation via an external contact, for example from a zone thermostat Hot / cold From external contacts. Summer/winter switching signal from outside, for example from the zone thermostat ECO function Dedicated setpoint for " Eco " operation. Settable with daily time band Anti-freeze protection Heat pump operation with circulator ON and possible electric booster Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€5.100,00
Ferroli Air-Water Reversible Heat Pump Inverter Ferroli Omnia S 3.2 12 Single-Phase R-32 With Control Included
ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS FREE FIRST START-UP Technical features Model : OMNIA S 3.2 12 Product code : 0XHKCSWA Command included Optional accessories Unpainted built-in cabinet 016092X0 Painted built-in cabinet 016093X0 Optional accessories Unpainted built-in cabinet 016092X0 Painted built-in cabinet 016093X0 Energy efficiency Energy class in heating at 35° C: A+++ Energy class in heating at 55° C: A++ SCOP heating with water set at 35 °C : 4.81 SEER cooling with water set at 7 °C: 4.89 Performance Heating Useful power in heating with water set at 35° C: 12.1 kW Useful power in heating with water set at 45° C: 12.3 kW Useful power in heating with water set at 55° C: 11.9 kW Absorbed power with water set at 35° C: 2.44 kW Absorbed power with water set at 45° C: 3.32 kW Absorbed power with water set at 55° C: 3.90 kW Water flow rate with water set at 35° C : 2081 l/h Water flow rate with water set at 45° C : 2116 /h Water flow rate with water set at 55° C : 1279 l/h Cooling down Useful power in cooling with water set at 7 °C: 11.5 kW Useful power in cooling with water set at 18 °C: 12.0 kW Absorbed power with water set at 7° C: 4.18 kW Absorbed power with water set at 18° C: 3.04 kW Water flow rate with water set at 7° C : 1978 l/h Water flow rate with water set at 18° C : 2064 l/h External unit technical data Compressor type : Twin Rotary DC Number of compressors : 1 Number of cooling circuits: 1 Type of fans : DC axial Number of fans : 1 Sound power level in heating : 56 ~ 65 dB(A) Sound power level in cooling : 56 ~ 65 dB(A) Liquid pipe diameter : 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Maximum piping length: 30 m Maximum pipe height difference: 20 m Indoor unit technical data Exchanger type : Brazed stainless steel plates Expansion vessel volume: 10 litres Water safety valve setting: 3 bar Minimum system water content: 40 litres System piping diameter: 1" gas F DHW piping diameter: 3/4" gas F Liquid pipe diameter : 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Electrical data Power supply (V,Hz, Ø) : 220~240/50/1 Refrigerant gas : R32 Dimensions and weight External unit dimensions (WxHxD): 1118x865x523 mm Outdoor unit weight: 96.0 Kg Internal unit dimensions (WxHxD): 422x702x320 mm 5 years without worries Ferroli OMNIA S 3.2 Reversible heat pumps for split installation with DC inverter compressor Quietness, efficiency and design OMNIA S 3.2 is the new range of split heat pumps Full Inverter R32 by Ferroli. The range includes an Outdoor Unit with the heart of the refrigerant circuit, from the compressor to the fan with the air side exchanger, which is connected to the refrigerant gas pipes towards the Indoor Unit. The Indoor Unit, on the other hand, contains the heart of the hydraulic circuit of the generator with all the main pre-installed components, such as the high-efficiency circulator and the expansion vessel, to safely allow quick and practical installation The split installation of OMNIA S 3.2 , with only the gas pipes between the outdoor and indoor unit, is synonymous with security against any freezing problem, even at the coldest temperatures (down to -25°C) and in the absence of electricity. All units meet the most extreme winter and summer air conditioning requirements, they can in fact produce hot water up to 65°C , which makes them suitable for practically all heating systems, whether radiant, fan coil or radiator, including the production of domestic hot water (DHW), via an external boiler The new conception Full Inverter by Ferroli uses DC inverter modulations on the 3 main energy-intensive components of the machine, i.e. compressor, fan and pump. This allows you to modulate the power supplied by finely tracking the thermal load and allowing the user very high efficiencies and important energy savings . Also, the concept Full Inverter by Ferroli guarantees sound levels among the lowest on the market, avoiding sudden changes in the network and guaranteeing a longer useful life for the components. Indoor and outdoor unit of OMNIA 3.2 The Outdoor Unit contains the heart of the refrigerant circuit, while the Internal Unit the heart of the hydraulic circuit. They are connected to each other by pipes R32 ecological refrigerant gas , which has allowed us to combine high efficiency with a reduced environmental impact. Thanks to his GWP of 675 , about a third of the GWP of R410a, helps reduce CO2 equivalent emissions, the main causes of global warming The heat pumps use the Outdoor Unit to extract heat from the air outside the home and convey it to the water in your system, via an exchanger in the Indoor Unit. That's exactly why they manage to get such high efficiencies , exploiting so renewable the energy already present in the air outside the home The new conception Full Inverter by Ferroli then does the rest, tracking the thermal loads precisely and without waste (modulating the compressor, pump and fan), manages to achieve even greater efficiencies, guaranteeing important savings in bills , without stress on the components and with very low sound levels OMNIA S 3.2 it can be used both as the sole generator of the system and integrated with other sources such as a Ferroli boiler The control system The user interface has been equipped with capsense technology with 2.8” graphic display, which allows the user to interact with the product easily and extremely simply Modbus protocol It can be interfaced to BMS/BACS automation and management systems Heating and cooling Full Inverter modulation finely follows the desired setpoints, with the possibility of setting heating and cooling climatic curves, further optimizing consumption for the user Domestic hot water production When the DHW temperature probe calls the machine, it automatically switches to the domestic hot water tank with dedicated DHW set point. 3-way diverter valve supplied as standard Smart Grid input from photovoltaic and grid Digital Smart Grid inputs for the management of an input from the photovoltaic system and from the electricity grid. These allow you to optimize consumption and bill costs DHW tank electrical resistance The DHW electrical integration serves as integration, anti-legionella or reserve source in the event of an anomaly Fast DHW Priority to DHW production to bring the storage tank to the set point in the shortest possible time Anti-legionella function Allows you to set anti-legionella weekly cycles Silent mode Reduces the frequency of the compressor and the speed of the fan, so as to significantly reduce noise. Programmable on time slots ON/OFF From external contact. Activation and deactivation via an external contact, for example from a zone thermostat Hot / cold From external contacts. Summer/winter switching signal from outside, for example from the zone thermostat ECO function Dedicated setpoint for " Eco " operation. Settable with daily time band Anti-freeze protection Heat pump operation with circulator ON and possible electric booster Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€4.875,00
Ferroli Air-Water Reversible Heat Pump Inverter Ferroli Omnia S 3.2 08 R-32 With Control Included
ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS FREE FIRST START-UP Technical features Model : OMNIA S 3.2 08 Product code : 0XHK8SWA Command included Optional accessories Unpainted built-in cabinet 016092X0 Painted built-in cabinet 016093X0 Optional accessories Unpainted built-in cabinet 016092X0 Painted built-in cabinet 016093X0 Energy efficiency Energy class in heating at 35° C: A+++ Energy class in heating at 55° C: A++ SCOP heating with water set at 35 °C : 5.21 SEER cooling with water set at 7 °C: 5.83 Performance Heating Useful power in heating with water set at 35° C: 8.40 kW Useful power in heating with water set at 45° C: 8.30 kW Useful power in heating with water set at 55° C: 7.50 kW Absorbed power with water set at 35° C: 1.63 kW Absorbed power with water set at 45° C: 2.16 kW Absorbed power with water set at 55° C: 2.36 kW Water flow rate with water set at 35° C : 1445 l/h Water flow rate with water set at 45° C : 1428 /h Water flow rate with water set at 55° C : 806 l/h Cooling down Useful power in cooling with water set at 7 °C: 7.45 kW Useful power in cooling with water set at 18 °C: 8.30 kW Absorbed power with water set at 7° C: 2.22 kW Absorbed power with water set at 18° C: 1.64 kW Water flow rate with water set at 7° C : 1281 l/h Water flow rate with water set at 18° C : 1428 l/h External unit technical data Compressor type : Twin Rotary DC Number of compressors : 1 Number of cooling circuits: 1 Type of fans : DC axial Number of fans : 1 Sound power level in heating : 55 ~ 61 dB(A) Sound power level in cooling : 54 ~ 61 dB(A) Liquid pipe diameter : 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Maximum piping length: 30 m Maximum pipe height difference: 20 m Indoor unit technical data Exchanger type : Brazed stainless steel plates Expansion vessel volume: 10 litres Water safety valve setting: 3 bar Minimum water content: 40 litres System piping diameter: 1" gas F DHW piping diameter: 3/4" gas F Liquid pipe diameter : 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Electrical data Power supply (V,Hz, Ø) : 220~240/50/1 Refrigerant gas : R32 Dimensions and weight External unit dimensions (WxHxD): 1118x865x523 mm Outdoor unit weight: 77.0 Kg Internal unit dimensions (WxHxD): 422x702x320 mm 5 years without worries Ferroli OMNIA S 3.2 Reversible heat pumps for split installation with DC inverter compressor Quietness, efficiency and design OMNIA S 3.2 is the new range of split heat pumps Full Inverter R32 by Ferroli. The range includes an Outdoor Unit with the heart of the refrigerant circuit, from the compressor to the fan with the air side exchanger, which is connected to the refrigerant gas pipes towards the Indoor Unit. The Indoor Unit, on the other hand, contains the heart of the hydraulic circuit of the generator with all the main pre-installed components, such as the high-efficiency circulator and the expansion vessel, to safely allow quick and practical installation The split installation of OMNIA S 3.2 , with only the gas pipes between the outdoor and indoor unit, is synonymous with security against any freezing problem, even at the coldest temperatures (down to -25°C) and in the absence of electricity. All units meet the most extreme winter and summer air conditioning requirements, they can in fact produce hot water up to 65°C , which makes them suitable for practically all heating systems, whether radiant, fan coil or radiator, including the production of domestic hot water (DHW), via an external boiler The new conception Full Inverter by Ferroli uses DC inverter modulations on the 3 main energy-intensive components of the machine, i.e. compressor, fan and pump. This allows you to modulate the power supplied by finely tracking the thermal load and allowing the user very high efficiencies and important energy savings . Also, the concept Full Inverter by Ferroli guarantees sound levels among the lowest on the market, avoiding sudden changes in the network and guaranteeing a longer useful life for the components. Indoor and outdoor unit of OMNIA 3.2 The Outdoor Unit contains the heart of the refrigerant circuit, while the Internal Unit the heart of the hydraulic circuit. They are connected to each other by pipes R32 ecological refrigerant gas , which has allowed us to combine high efficiency with a reduced environmental impact. Thanks to his GWP of 675 , about a third of the GWP of R410a, helps reduce CO2 equivalent emissions, the main causes of global warming The heat pumps use the Outdoor Unit to extract heat from the air outside the home and convey it to the water in your system, via an exchanger in the Indoor Unit. That's exactly why they manage to get such high efficiencies , exploiting so renewable the energy already present in the air outside the home The new conception Full Inverter by Ferroli then does the rest, tracking the thermal loads precisely and without waste (modulating the compressor, pump and fan), manages to achieve even greater efficiencies, guaranteeing important savings in bills , without stress on the components and with very low sound levels OMNIA S 3.2 it can be used both as the sole generator of the system and integrated with other sources such as a Ferroli boiler The control system The user interface has been equipped with capsense technology with 2.8” graphic display, which allows the user to interact with the product easily and extremely simply Modbus protocol It can be interfaced to BMS/BACS automation and management systems Heating and cooling Full Inverter modulation finely follows the desired setpoints, with the possibility of setting heating and cooling climatic curves, further optimizing consumption for the user Domestic hot water production When the DHW temperature probe calls the machine, it automatically switches to the domestic hot water tank with dedicated DHW set point. 3-way diverter valve supplied as standard Smart Grid input from photovoltaic and grid Digital Smart Grid inputs for the management of an input from the photovoltaic system and from the electricity grid. These allow you to optimize consumption and bill costs DHW tank electrical resistance The DHW electrical integration serves as integration, anti-legionella or reserve source in the event of an anomaly Fast DHW Priority to DHW production to bring the storage tank to the set point in the shortest possible time Anti-legionella function Allows you to set anti-legionella weekly cycles Silent mode Reduces the frequency of the compressor and the speed of the fan, so as to significantly reduce noise. Programmable on time slots ON/OFF From external contact. Activation and deactivation via an external contact, for example from a zone thermostat Hot / cold From external contacts. Summer/winter switching signal from outside, for example from the zone thermostat ECO function Dedicated setpoint for " Eco " operation. Settable with daily time band Anti-freeze protection Heat pump operation with circulator ON and possible electric booster Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€3.600,00
Ferroli Air-Water Reversible Heat Pump Inverter Ferroli Omnia S 3.2 04 R-32 With Control Included
ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS FREE FIRST START-UP Technical features Model : OMNIA S 3.2 04 Product code : 0XHK4SWA Command included Optional accessories Unpainted built-in cabinet 016092X0 Painted built-in cabinet 016093X0 Energy efficiency Energy class in heating at 35° C: A+++ Energy class in heating at 55° C: A++ SCOP heating with water set at 35 °C : 4.85 SEER cooling with water set at 7 °C: 4.99 Performance Heating Useful power in heating with water set at 35° C: 4.20 kW Useful power in heating with water set at 45° C: 4.30 kW Useful power in heating with water set at 55° C: 4.40 kW Absorbed power with water set at 35° C: 0.82 kW Absorbed power with water set at 45° C: 1.13 kW Absorbed power with water set at 55° C: 1.49 kW Water flow rate with water set at 35° C : 722 l/h Water flow rate with water set at 45° C : 740 l/h Water flow rate with water set at 55° C : 473 l/h Cooling down Useful power in cooling with water set at 7 °C: 4.70 kW Useful power in cooling with water set at 18 °C: 4.50 kW Absorbed power with water set at 7° C: 1.36 kW Absorbed power with water set at 18° C: 0.82 kW Water flow rate with water set at 7° C : 808 l/h Water flow rate with water set at 18° C : 774 l/h External unit technical data Compressor type : Twin Rotary DC Number of compressors : 1 Number of cooling circuits: 1 Type of fans : DC axial Number of fans : 1 Sound power level in heating : 53 ~ 60 dB(A) Sound power level in cooling : 52 ~ 60 dB(A) Liquid piping diameter : 6.35 mm (1/4") Gas pipe diameter: 15.88 (5/8") Maximum piping length: 30 m Maximum pipe height difference: 20 m Indoor unit technical data Exchanger type : Brazed stainless steel plates Expansion vessel volume: 10 litres Water safety valve setting: 3 bar Minimum system water content: 40 litres System piping diameter: 1" gas F DHW piping diameter: 3/4" gas F Liquid pipe diameter : 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Electrical data Power supply (V,Hz, Ø) : 220~240/50/1 Refrigerant gas : R32 Dimensions and weight External unit dimensions (WxHxD): 1008x712x426 mm Outdoor unit weight: 58.0 Kg Internal unit dimensions (WxHxD): 422x702x320 mm 5 years without worries Ferroli OMNIA S 3.2 Reversible heat pumps for split installation with DC inverter compressor Quietness, efficiency and design OMNIA S 3.2 is the new range of split heat pumps Full Inverter R32 by Ferroli. The range includes an Outdoor Unit with the heart of the refrigerant circuit, from the compressor to the fan with the air side exchanger, which is connected to the refrigerant gas pipes towards the Indoor Unit. The Indoor Unit, on the other hand, contains the heart of the hydraulic circuit of the generator with all the main pre-installed components, such as the high-efficiency circulator and the expansion vessel, to safely allow quick and practical installation The split installation of OMNIA S 3.2 , with only the gas pipes between the outdoor and indoor unit, is synonymous with security against any freezing problem, even at the coldest temperatures (down to -25°C) and in the absence of electricity. All units meet the most extreme winter and summer air conditioning requirements, they can in fact produce hot water up to 65°C , which makes them suitable for practically all heating systems, whether radiant, fan coil or radiator, including the production of domestic hot water (DHW), via an external boiler The new conception Full Inverter by Ferroli uses DC inverter modulations on the 3 main energy-intensive components of the machine, i.e. compressor, fan and pump. This allows you to modulate the power supplied by finely tracking the thermal load and allowing the user very high efficiencies and important energy savings . Also, the concept Full Inverter by Ferroli guarantees sound levels among the lowest on the market, avoiding sudden changes in the network and guaranteeing a longer useful life for the components. Indoor and outdoor unit of OMNIA 3.2 The Outdoor Unit contains the heart of the refrigerant circuit, while the Internal Unit the heart of the hydraulic circuit. They are connected to each other by pipes R32 ecological refrigerant gas , which has allowed us to combine high efficiency with a reduced environmental impact. Thanks to his GWP of 675 , about a third of the GWP of R410a, helps reduce CO2 equivalent emissions, the main causes of global warming The heat pumps use the Outdoor Unit to extract heat from the air outside the home and convey it to the water in your system, via an exchanger in the Indoor Unit. That's exactly why they manage to get such high efficiencies , exploiting so renewable the energy already present in the air outside the home The new conception Full Inverter by Ferroli then does the rest, tracking the thermal loads precisely and without waste (modulating the compressor, pump and fan), manages to achieve even greater efficiencies, guaranteeing important savings in bills , without stress on the components and with very low sound levels OMNIA S 3.2 it can be used both as the sole generator of the system and integrated with other sources such as a Ferroli boiler The control system The user interface has been equipped with capsense technology with 2.8” graphic display, which allows the user to interact with the product easily and extremely simply Modbus protocol It can be interfaced to BMS/BACS automation and management systems Heating and cooling Full Inverter modulation finely follows the desired setpoints, with the possibility of setting heating and cooling climatic curves, further optimizing consumption for the user Domestic hot water production When the DHW temperature probe calls the machine, it automatically switches to the domestic hot water tank with dedicated DHW set point. 3-way diverter valve supplied as standard Smart Grid input from photovoltaic and grid Digital Smart Grid inputs for the management of an input from the photovoltaic system and from the electricity grid. These allow you to optimize consumption and bill costs DHW tank electrical resistance The DHW electrical integration serves as integration, anti-legionella or reserve source in the event of an anomaly Fast DHW Priority to DHW production to bring the storage tank to the set point in the shortest possible time Anti-legionella function Allows you to set anti-legionella weekly cycles Silent mode Reduces the frequency of the compressor and the speed of the fan, so as to significantly reduce noise. Programmable on time slots ON/OFF From external contact. Activation and deactivation via an external contact, for example from a zone thermostat Hot / cold From external contacts. Summer/winter switching signal from outside, for example from the zone thermostat ECO function Dedicated setpoint for " Eco " operation. Settable with daily time band Anti-freeze protection Heat pump operation with circulator ON and possible electric booster Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€3.225,00
Ferroli Ferroli Omnia M 3.2 16 Kw 2cp000gf Single-Phase Reversible Heat Pump For Outdoor Installation With R-32 Dc Inverter Compressor Wi-Fi With Control Included
ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS FREE FIRST START-UP Technical features Model : OMNIA M 3.2 16 Product code : 2CP000GF Command included Energy efficiency Energy class in heating at 35° C: A+++ Energy class in heating at 55° C: A+++ SCOP heating with water set at 35 °C : 4.62 SCOP heating with water set at 45 °C : 3.41 SEER cooling with water set at 7 °C: 4.69 SEER cooling with water set at 18 °C: 6.75 Performance Heating Useful power in heating with water set at 35° C: 15.9 kW Useful power in heating with water set at 45° C: 16.0 kW Useful power in heating with water set at 55°C: 16.0 kW Absorbed power with water set at 35° C: 3.53 kW Absorbed power with water set at 45° C: 4.57 kW Absorbed power with water set at 55° C: 5.61 kW Water flow rate with water set at 35° C : 2735 l/h Water flow rate with water set at 45° C : 2752 l/h Water flow rate with water set at 55° C : 1720 l/h Cooling down Useful power in cooling with water set at 7 °C: 14.0 kW Useful power in cooling with water set at 18 °C: 13.6 kW Absorbed power with water set at 7° C: 5.60 kW Absorbed power with water set at 18° C: 3.77 kW Water flow rate with water set at 7° C : 2408 l/h Water flow rate with water set at 18° C : 2339 l/h Technical data Compressor type : Twin Rotary DC Number of compressors : 1 Number of cooling circuits: 1 Type of fans : DC axial Number of fans : 1 Expansion vessel volume: 5 litres Water safety valve setting: 3 bar Minimum system water content: 25 litres Sound power level in heating : 56 ~ 69 dB(A) Sound power level in cooling : 56 ~ 69 dB(A) Electrical data Power supply (V,Hz, Ø) : 220~240/50/1 Refrigerant gas : R32 Maximum absorbed current: 27A Installation data Delivery pipe diameter: 1 ¼” M Return pipe diameter: 1 ¼” M Dimensions and weight Dimensions (WxHxD): 1385x865x526 mm Weight : 129Kg 5 years without worries Ferroli OMNIA M 3.2 Reversible heat pumps for outdoor installation with DC inverter compressor A heat pump with silent and ecological efficiency This series of air-to-water heat pumps with low environmental impact ecological gas R32 satisfies the winter and summer air conditioning needs of residential and commercial systems of small and medium power. All the units are suitable for outdoor installation and being able to produce water up to 65°C they can be used in radiant systems, fan coils, radiators and for the indirect production of DHW domestic hot water via an optional external boiler The units are characterized by the use of a DC inverter compressor which allows the power supplied to be modulated and are complete with a hydronic kit made up of all the essential components for quick and safe installation. The units are characterized by high energy efficiency and low sound levels which allow them to be used as a single generator serving the system or integrated with other energy sources such as electric support heaters or boilers All units are supplied as standard with a DHW tank water temperature probe and with an external air temperature probe, already installed on the unit, to carry out climatic regulation in heating and cooling. All units are carefully built and individually tested in the factory. The installation requires only the electrical and hydraulic connections. In a system it is possible to connect a maximum of 6 units in cascade; one of them will be “MASTER” while the others will be “SLAVE” units. Refrigerant circuit Contained inside the unit to facilitate maintenance operations, it is equipped with a compressor with a Twin rotary type DC Inverter motor to guarantee greater dynamic balancing and reduce vibrations. It is placed on rubber anti-vibration mounts and wrapped in a double layer of sound-absorbing material to reduce noise. The compressor is also equipped with a crankcase oil heater. The circuit is completed by a brazed stainless steel plate heat exchanger complete with antifreeze heater, axial fans with brushless DC motor complete with safety grilles, finned coil with anti-corrosion treatment made up of copper pipes and aluminum fins. All units are equipped with variable speed control of the fans which allows operation with low outside temperatures in cooling and high outside temperatures in heating Hydraulic circuit Contained inside the unit to facilitate maintenance operations, it is equipped as standard with a low-consumption circulator with brushless DC motor, water flow switch, automatic air vent, water pressure gauge, expansion tank, safety valve, Y-shaped water filter The plate heat exchanger and all the hydraulic circuit pipes are thermally insulated to prevent the formation of condensate and reduce heat loss Air source The benefits offered by this technology Aerothermal energy is the energy of the future. Ferroli aerothermal heat pumps use clean technology capable of obtaining up to 79% of the energy supplied for home comfort from the outside air. Ferroli aerothermal heat pumps are designed to provide cooling in summer, heating in winter and/or domestic hot water throughout the year. These latest generation heat pumps with inverter technology and the use of an ecological gas such as R32 do not produce heat from the combustion of a fuel but, simply with minimal energy consumption, exploit the energy in the air and transfer it to the inside the house Greater efficiency The OMNIA M 3.2 monobloc range has energy class A++ for the production of water at 55ºC and A+++ for the water produced at 35°C Compact outdoor unit. More space available Thanks to the adoption of a compact and small-sized unit, especially for the more powerful models, OMNIA M 3.2 can be easily placed outside the house, guaranteeing more available space inside Quick and easy installation Being a packaged unit, installation costs and times are significantly reduced. The interconnection of the refrigerant between the units is not necessary, as the entire refrigerant circuit is contained in the equipment, it is not even necessary to make a connection to bring the fuel, nor to create a flue gas evacuation duct. In addition, the device includes all the plumbing elements necessary for correct and quick connection to the plumbing and DHW heating system. Ideal combination with low temperature systems The OMNIA M 3.2 range can be easily installed in combination with low temperature systems, connecting fan coils, radiators, underfloor heating, to obtain maximum energy efficiency and maximum domestic comfort Easy integration with an existing boiler OMNIA M 3.2 can be combined and integrated with any boiler in the system. The control of the device, based on the external temperature and the required operating conditions, optimizes the production of heat for heating and DHW, using the device with the best efficiency Production of hot water at 65°C with low external temperature The OMNIA M 3.2 range is able to supply hot water at 60°C with an external temperature down to -15°C and at 40°C with an external temperature down to -25°C, without any type of support/accessory. With cold but positive temperatures OMNIA M 3.2 can produce hot water up to 65°C Protection against freezing of hydraulic components without the need to add glycol If low outside temperatures are detected, the circulation pump and the electric antifreeze heater of the plate heat exchanger are activated, thus preventing freezing of the hydraulic components. There is therefore no need to add glycol to the system Control system Operating principle The general control system allows monitoring of all the functions of the inverter system and of the correct functioning of the compressor. It also incorporates regulation algorithms using predefined climatic curves that can be selected by the customer, the management of a DHW circuit, the setting of time slots for noise reduction during the night, alarm signaling, pump block prevention and integration with external heat generators. The user interface consists of a wired remote controller which allows the management of: Management of 2 distinct zones, direct + mixed The unit is able to manage the pumps of both zones and for the mixed in addition the mixing valve and water delivery temperature probe Photovoltaic and Smart Grid management The management of a photovoltaic system and of the "intelligent grid" function is ensured by 2 digital inputs on the PCB with specific operating logics Heating and cooling system The unit activates in hot or cold mode, works by modulating the frequency of the compressor to keep the water temperature produced at the setpoint value set via the controller Domestic hot water production The unit activates in heating mode to maintain the temperature of a DHW tank at the set point value. A 3-way diverter valve is required (not supplied) and a temperature probe, supplied as standard, to be inserted in a well of the DHW boiler. Additional energy sources These sources can be activated in Integration or replacement of the heat pump during heating service or for DHW production and in case the heat pump does not work. Cascade management of several units Possibility of managing up to 6 units in cascade even with different powers with a single controller connected to the Master. In the event of an anomaly in one "Slave", the others can function normally DHW tank electric resistance It is possible to manage a possible integration and/or reserve electric resistance and for the anti-legionella function Fast DHW Function that can be activated manually which allows you to give priority to domestic hot water by bringing the DHW tank to the set point in the shortest possible time Anti-legionella function Weekly anti-legionella cycles can be set. The heat pump must be integrated with a DHW boiler electric heater or boiler Silenced mode 2 levels of silence are possible which, if active, according to an hourly programming, involve a reduction in the maximum frequency of the compressor and in the speed of the fan to reduce the noise emitted perhaps during the night and the power absorbed by the unit ON/OFF The unit can be switched on and off via an external contact. It can be operated from the controller keyboard Hot/Cold The unit can be switched on and off in cold and hot mode via 2 external contacts ECO Possibility of defining time slots and related setpoint for ECO modes in hot and cold mode Weekly programming Allows differentiated time programming for each day of the week by defining the working mode and setpoint for each band Anti-freeze protection Guaranteed up to an external air temperature of -20°C thanks to the heat pump itself operating in hot mode, to the standard anti-freeze electrical resistance and to the electric booster if installed. Remote control of the unit via APP Available for iOS and Android Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€3.820,00
Ferroli Ferroli Omnia M 3.2 14 Kw 2cp000if Three-Phase Reversible Heat Pump For Outdoor Installation With R-32 Dc Inverter Compressor Wi-Fi With Control Included
ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS FREE FIRST START-UP Technical features Model : OMNIA M 3.2 14-T Product code : 2CP000IF Command included Energy efficiency Energy class in heating at 35° C: A+++ Energy class in heating at 55° C: A+++ SCOP heating with water set at 35 °C : 4.72 SCOP heating with water set at 45 °C : 3.47 SEER cooling with water set at 7 °C: 4.83 SEER cooling with water set at 18 °C: 6.85 Performance Heating Useful power in heating with water set at 35° C: 14.5 kW Useful power in heating with water set at 45° C: 14.1 kW Useful power in heating with water set at 55° C: 13.8 kW Absorbed power with water set at 35° C: 3.15 kW Absorbed power with water set at 45° C: 3.92 kW Absorbed power with water set at 55° C: 4.68 kW Water flow rate with water set at 35° C : 2494 l/h Water flow rate with water set at 45° C : 2425 l/h Water flow rate with water set at 55° C : 1484 l/h Cooling down Useful power in cooling with water set at 7 °C: 12.4 kW Useful power in cooling with water set at 18 °C: 12.9 kW Absorbed power with water set at 7° C: 4.96 kW Absorbed power with water set at 18° C: 3.49 kW Water flow rate with water set at 7° C : 2133 l/h Water flow rate with water set at 18° C : 2219 l/h Technical data Compressor type : Twin Rotary DC Number of compressors : 1 Number of cooling circuits: 1 Type of fans : DC axial Number of fans : 1 Expansion vessel volume: 5 litres Water safety valve setting: 3 bar Minimum system water content: 25 litres Sound power level in heating : 56 ~ 65 dB(A) Sound power level in cooling : 56 ~ 65 dB(A) Electrical data Power supply (V,Hz, Ø) : 380~415/50/3 Refrigerant gas : R32 Maximum absorbed current: 11A Installation data Delivery pipe diameter: 1 ¼” M Return pipe diameter: 1 ¼” M Dimensions and weight Dimensions (WxHxD): 1385x865x526 mm Weight : 144Kg 5 years without worries Ferroli OMNIA M 3.2 Reversible heat pumps for outdoor installation with DC inverter compressor A heat pump with silent and ecological efficiency This series of air-to-water heat pumps with low environmental impact ecological gas R32 satisfies the winter and summer air conditioning needs of residential and commercial systems of small and medium power. All the units are suitable for outdoor installation and being able to produce water up to 65°C they can be used in radiant systems, fan coils, radiators and for the indirect production of DHW domestic hot water via an optional external boiler The units are characterized by the use of a DC inverter compressor which allows the power supplied to be modulated and are complete with a hydronic kit made up of all the essential components for quick and safe installation. The units are characterized by high energy efficiency and low sound levels which allow them to be used as a single generator serving the system or integrated with other energy sources such as electric support heaters or boilers All units are supplied as standard with a DHW tank water temperature probe and with an external air temperature probe, already installed on the unit, to carry out climatic regulation in heating and cooling. All units are carefully built and individually tested in the factory. The installation requires only the electrical and hydraulic connections. In a system it is possible to connect a maximum of 6 units in cascade; one of them will be “MASTER” while the others will be “SLAVE” units. Refrigerant circuit Contained inside the unit to facilitate maintenance operations, it is equipped with a compressor with a Twin rotary type DC Inverter motor to guarantee greater dynamic balancing and reduce vibrations. It is placed on rubber anti-vibration mounts and wrapped in a double layer of sound-absorbing material to reduce noise. The compressor is also equipped with a crankcase oil heater. The circuit is completed by a brazed stainless steel plate heat exchanger complete with antifreeze heater, axial fans with brushless DC motor complete with safety grilles, finned coil with anti-corrosion treatment made up of copper pipes and aluminum fins. All units are equipped with variable speed control of the fans which allows operation with low outside temperatures in cooling and high outside temperatures in heating Hydraulic circuit Contained inside the unit to facilitate maintenance operations, it is equipped as standard with a low-consumption circulator with brushless DC motor, water flow switch, automatic air vent, water pressure gauge, expansion tank, safety valve, Y-shaped water filter The plate heat exchanger and all the hydraulic circuit pipes are thermally insulated to prevent the formation of condensate and reduce heat loss Air source The benefits offered by this technology Aerothermal energy is the energy of the future. Ferroli aerothermal heat pumps use clean technology capable of obtaining up to 79% of the energy supplied for home comfort from the outside air. Ferroli aerothermal heat pumps are designed to provide cooling in summer, heating in winter and/or domestic hot water throughout the year. These latest generation heat pumps with inverter technology and the use of an ecological gas such as R32 do not produce heat from the combustion of a fuel but, simply with minimal energy consumption, exploit the energy in the air and transfer it to the inside the house Greater efficiency The OMNIA M 3.2 monobloc range has energy class A++ for the production of water at 55ºC and A+++ for the water produced at 35°C Compact outdoor unit. More space available Thanks to the adoption of a compact and small-sized unit, especially for the more powerful models, OMNIA M 3.2 can be easily placed outside the house, guaranteeing more available space inside Quick and easy installation Being a packaged unit, installation costs and times are significantly reduced. The interconnection of the refrigerant between the units is not necessary, as the entire refrigerant circuit is contained in the equipment, it is not even necessary to make a connection to bring the fuel, nor to create a flue gas evacuation duct. In addition, the device includes all the plumbing elements necessary for correct and quick connection to the plumbing and DHW heating system. Ideal combination with low temperature systems The OMNIA M 3.2 range can be easily installed in combination with low temperature systems, connecting fan coils, radiators, underfloor heating, to obtain maximum energy efficiency and maximum domestic comfort Easy integration with an existing boiler OMNIA M 3.2 can be combined and integrated with any boiler in the system. The control of the device, based on the external temperature and the required operating conditions, optimizes the production of heat for heating and DHW, using the device with the best efficiency Production of hot water at 65°C with low external temperature The OMNIA M 3.2 range is able to supply hot water at 60°C with an external temperature down to -15°C and at 40°C with an external temperature down to -25°C, without any type of support/accessory. With cold but positive temperatures OMNIA M 3.2 can produce hot water up to 65°C Protection against freezing of hydraulic components without the need to add glycol If low outside temperatures are detected, the circulation pump and the electric antifreeze heater of the plate heat exchanger are activated, thus preventing freezing of the hydraulic components. There is therefore no need to add glycol to the system Control system Operating principle The general control system allows monitoring of all the functions of the inverter system and of the correct functioning of the compressor. It also incorporates regulation algorithms using predefined climatic curves that can be selected by the customer, the management of a DHW circuit, the setting of time slots for noise reduction during the night, alarm signaling, pump block prevention and integration with external heat generators. The user interface consists of a wired remote controller which allows the management of: Management of 2 distinct zones, direct + mixed The unit is able to manage the pumps of both zones and for the mixed in addition the mixing valve and water delivery temperature probe Photovoltaic and Smart Grid management The management of a photovoltaic system and of the "intelligent grid" function is ensured by 2 digital inputs on the PCB with specific operating logics Heating and cooling system The unit activates in hot or cold mode, works by modulating the frequency of the compressor to keep the water temperature produced at the setpoint value set via the controller Domestic hot water production The unit activates in heating mode to maintain the temperature of a DHW tank at the set point value. A 3-way diverter valve is required (not supplied) and a temperature probe, supplied as standard, to be inserted in a well of the DHW boiler. Additional energy sources These sources can be activated in Integration or replacement of the heat pump during heating service or for DHW production and in case the heat pump does not work. Cascade management of several units Possibility of managing up to 6 units in cascade even with different powers with a single controller connected to the Master. In the event of an anomaly in one "Slave", the others can function normally DHW tank electric resistance It is possible to manage a possible integration and/or reserve electric resistance and for the anti-legionella function Fast DHW Function that can be activated manually which allows you to give priority to domestic hot water by bringing the DHW tank to the set point in the shortest possible time Anti-legionella function Weekly anti-legionella cycles can be set. The heat pump must be integrated with a DHW boiler electric heater or boiler Silenced mode 2 levels of silence are possible which, if active, according to an hourly programming, involve a reduction in the maximum frequency of the compressor and in the speed of the fan to reduce the noise emitted perhaps during the night and the power absorbed by the unit ON/OFF The unit can be switched on and off via an external contact. It can be operated from the controller keyboard Hot/Cold The unit can be switched on and off in cold and hot mode via 2 external contacts ECO Possibility of defining time slots and related setpoint for ECO modes in hot and cold mode Weekly programming Allows differentiated time programming for each day of the week by defining the working mode and setpoint for each band Anti-freeze protection Guaranteed up to an external air temperature of -20°C thanks to the heat pump itself operating in hot mode, to the standard anti-freeze electrical resistance and to the electric booster if installed. Remote control of the unit via APP Available for iOS and Android Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€4.370,00
BAXI Offer Baxi Auriga 5m R-32 Single-Phase Air-Water Monobloc Inverter A7794318 Complete With Control - New
ATTENTION ! OFFER VALID UNTIL STOCKS LAST FIRST START UP INCLUDED! Technical features Thermal power (air +7°C (bs) / +6°C (bu) and delivery temperature of +35°C - EN 14511): 4.65 kW COP: 5.00 Cooling capacity (air +35°C (bs) and delivery temperature +7°C - EN 14511): 4.60 kW EER: 2.98 SEER: 4.71 R32 refrigerant charge: 2.00 kg Number/type of compressors: 1/rotary DC inverter Number of fans: 1 Nominal water flow (winter operation): 0.80 m³/h Circulation pump useful head: 55 kPa Inlet/outlet hydraulic connections: 1” male / 1” male Power supply voltage: 230V 1P+N+T Power supply frequency: 50Hz Overall dimensions H x W x D: 945mm x 1210mm x 402mm Weight: 92kg Sound power: 61dB(A) Sound pressure at 1 meter in free field on a reflective surface: 48.8 dB(A) BAXI AURIGA Inverter Monobloc Air-Water Heat Pumps Baxi introduces Auriga , the range of inverter packaged air-to-water heat pumps with single-phase and three-phase power supply. The range is characterized by the ease and simplicity of installation . Furthermore, the increased head of the on-board circulator allows the unit to be installed in large-scale systems, to cover greater distances from the heating plant or to install the unit directly to serve the fan coils. The range is wide and consists of 8 models from 4 to 16 kW, single-phase and three-phase versions Wide range of powers from 4 to 16 kW to satisfy all system requirements: heating, cooling and DHW production Easy to install in various living contexts, the increased head pump allows you to cope with greater pressure drops such as large systems or directly serving the fan coils STANDARD complete hydraulic equipment circulation pump, flow switch, expansion tank, safety valve, pressure gauge and “Y” filter Remote control panel control of system functions, programming and parameter verification. Furthermore, the connection via Modbus allows integration with BMS systems ErP Energy Labeling the labeling regulation (EU Regulation 2017/1369) requires the labeling of products according to a decreasing energy scale that goes from A+++ to D (in heating) and from A+ to F (in sanitary). The 5M/7M/9M models achieve an efficiency of A+++ in low temperature heating Components > Twin rotary DC inverter compressor : complete with internal thermal protection and crankcase heater, it is mounted on vibration dampers and wrapped around an insulating cap to reduce the transmission of noise and vibrations due to operation > Water-refrigerant exchanger : with brazed plates in AISI 316 steel with external anti-condensation insulation in expanded polypropylene and antifreeze resistance to prevent the formation of ice in the exchanger > Air-refrigerant exchanger : finned aluminum coil with hydrophilic treatment to facilitate the outflow of the condensate, mechanically expanded copper pipes with internal shaping to increase the heat exchange Furthermore, the optimized circuitry reduces the formation of ice in the coil during heat pump operation > Fan : axial fan directly coupled to the high efficiency brushless DC variable speed motor. The fan is installed on aerodynamic nozzles and safety grilles > Refrigerant circuit : made of pickled copper, it includes the electronic expansion valve, drier filters, high and low pressure switches, pressure transducer, cycle inversion valves, liquid receiver and separator, refrigerant injection valve on the suction side > Hydraulic circuit : in addition to the brazed plate heat exchanger, the unit includes the high head circulator, the expansion vessel, the safety valve, the flow switch, the pressure gauge and the air vent valve and the metal mesh Y-filter (assembly by the installer) > Electrical panel : includes fuse protection of the main internal components; the terminal block is divided into a power section for supplying the unit and a control terminal block for connecting auxiliary inputs and outputs and connection to the control panel Main Features BAXI AURIGA Maximum energy efficiency Monobloc system for the production of heating, cooling and DHW Wide operating range, with external air down to -25°C in heating, up to 46°C in cooling DHW system management: production up to 60°C, storage tank temperature management, DHW recirculation pump and solar thermal integration Suitable for integration with radiant terminals, fan coils and mixed systems Integrated management with various plant systems: boiler integration, solar integration, management of diverter valves and secondary circuit pump Single-phase and three-phase power supply Compressor with DC inverter technology with high modulation range Modbus network connection Low GWP R32 refrigerant Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€3.900,00€2.399,00