Sime Praktica 25 He Low Nox Condensing Boiler Kit Fumes Free Methane - New Erp
Sime Praktica 25 He Low Nox Condensing Boiler Kit Fumes Free Methane - New Erp is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
How shipping works
How shipping works
Shipping costs vary depending on the weight and shipping method of your order. Our shipping services:
- Standard Shipping: Estimated delivery within 2 to 5 business days
- Premium Shipping: Guaranteed delivery within 24 business hours
- Premium Shipping + Home Delivery: Guaranteed delivery within 24 business hours
See the tables for standard shipping prices for Italy and the Minor Islands and Disadvantaged Areas.
For more details on Premium Shipping, please visit the Premium Shipping page.
Customer service
Customer service
Our customer service team is dedicated to providing support to our customers with any issues or questions they may have before or after purchasing our products.
Use the direct communication channel to speak with one of our representatives, or send us an email at one of the addresses listed on the contact us page.
Our customer service team is made up of highly qualified professionals who are always ready to help customers resolve any issue or answer any question quickly and efficiently. We are committed to ensuring maximum customer satisfaction and providing the highest quality after-sales service. So, if you need assistance, don't hesitate to contact us; we'll be happy to help in any way we can.
Description
Description
Sime Praktica 25 HE condensing boiler Low NOx flue gas kit methane - New ErP
- Nominal thermal power (80-60°C) kW 19.8
- Nominal thermal power (50-30°C) kW 21.2
- Reduced heat output G20 (80-60°C) kW 3.8
- Reduced heat output G20 (50-30°C) kW 4.2
- Reduced thermal power G31 (80-60°C) kW 4.3
- Reduced thermal power G31 (50-30°C) kW 4.7
- Nominal heat input in heating kW 20
- DHW nominal heat input kW 24
- Reduced heat input G20/G31 kW 4.0/4.5
- Useful efficiency min/max (80-60°C) % 95.4/98.8
- Useful efficiency min/max (50-30°C) % 105.0/106.1
- Useful efficiency 30% of the load (40-30°C) % 108.4
- Yield min. of combustion in situ (Presidential Decree 311) % 92.59
ELECTRICAL DATA
- Power supply voltage/frequency V/Hz 230/50
- Electric absorbed power max W 67
- Electric power absorbed min W 53
- Electrical power absorbed by the system pump W 41
- Shutdown losses at 50°C (EN 15502) W 120
- Electrical protection degree IP X5D
- Seasonal heating energy efficiency class. TO
- Seasonal heating energy efficiency % ninety two
- Heating sound power dB (A) 54
- Sanitary energy efficiency class A
- Sanitary energy efficiency % 89
- Declared load sanitary profile
- Heating adjustment range °C 20/80
- Boiler water content 5.10 l
- Max working pressure bar 3
- Max operating temperature °C 85
- Expansion vessel capacity l 9
- Nominal heat input kW 24
- Reduced heat input G20/G31 kW 4/4.5
- DHW adjustment range °C 10/60
- Specific sanitary flow rate (EN 13203) l/min 11.5
- Continuous DHW flow (∆t 25/35°C) l/min 13.8/9.8
- DHW flow rate min l/min 2
- Sanitary pressure min/max bar 0.5/7.0
Dimensions
- HxWxD mm 702x400x250
PRAKTICA
Premixed condensing gas wall mounted boiler for heating only and instantaneous hot water production
- Installation type: B23P-B33P-B53P-C13-C33-C43-C53-C63-C83-C93
- NOx emission class 6 (EN 15502-1:2015)
- Microprocessor electronic card with automatic adjustment of ignition power and maximum heating
- Automatic ignition with flame ionization control
- Degree of electrical protection to water IP X5D
- Primary water/fume coil exchanger in AISI 316L stainless steel
- Sanitary plate heat exchanger in stainless steel
- Heating system expansion tank
- Motorized diverter valve
- Retroactive combustion control with electronic gas valve
- Fume evacuation fan with electronic speed variation
- High efficiency system pump with low energy consumption (ErP)
- By-pass which ensures the circulation of water in the boiler when taps and thermostatic valves are used in the system
- Safety thermostat against overheating of the primary exchanger
- Smoke overheating probe
- 3 bar system safety valve
- Anti-blocking function of the pump and the diverter valve which activates automatically every 24 hours if there have been no requests for heat
- Antifreeze function which activates automatically if the water temperature in the boiler falls below the value set at
- parameter “tS 1.0” and, in the presence of an external probe, if the external temperature drops below the value set in parameter “tS 1.1”
- Chimney sweep function which lasts 15 minutes and facilitates the task of qualified personnel for measuring parameters and combustion efficiency
- Control panel equipped with display with numerical code self-diagnosis
- Knobs for adjusting the heating and domestic hot water temperatures
- Arrangement for SIME HOME remote control connection (optional)
- Protection of hydraulic fittings to be placed under the boiler cod. 8094530 (optional)
- Suitable for operation in a partially protected place according to EN 15502, with a maximum ambient temperature of 60°C and a minimum of -5°C
- Integrated climatic regulation
- Manual system loading device and water pressure control manometer
- Pressure transducer which blocks the boiler in case of water shortage
- Connections to the system in brass (DIN)
Product Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
Technical Data Sheet
Technical Data Sheet
- peso: 30.0 kg
- classe energetica produzione acs: A
- classe energetica riscaldamento: A
- gas: Methane
- marca: Syme
- metri quadri : 150
- modello: 8115005
- potenza in kw: 25
- potenza nominale: 25
- superficie riscaldabile mq: 150