icon Ferroli | CaldaieMurali

Ferroli

Ferroli

Discover our exclusive selection of Atlas Filters, perfect for enriching your home or workspace with style, comfort and functionality. Each piece is chosen to guarantee the best quality and satisfy your every need.

523 products


  • immagine-1-ferroli-pompa-di-calore-splittata-reversibile-aria-acqua-inverter-ferroli-omnia-st-3.2-08-sistema-con-integrazione-elettrica-r-32-con-comando-incluso

    Ferroli Air-Water Reversible Split Heat Pump Inverter Ferroli Omnia St 3.2 08 System With R-32 Electrical Integration With Control Included

    ATTENTION! IN CASE OF UNAVAILABILITY IMMEDIATELY, THE PRODUCT WILL BE ORDERED AND SHIPPED WITHIN 10 WORKING DAYS   FIRST START-UP FREE Technical Features Model : OMNIA S 3.2 08 Product Code : 0XHT8SWA Command included Optional accessories CONNECT CRP remote control Performance Heating Useful power in heating with water set at 35° C: 8.40 kW Useful power in heating with water set at 45° C: 8.30 kW Useful power in heating with water set at 55° C: 7.50 kW Power absorbed with water set at 35°C: 1.63 kW Power absorbed with water set at 45°C: 2.16 kW Power absorbed with water set at 55°C: 2.36 kW Water flow rate with water set at 35°C: 1445 l/h Water flow rate with water set at 45°C: 1428 /h Water flow rate with water set at 55°C: 806 l/h Cooling Useful power in cooling with water set at 7 °C: 7.45 kW Useful power in cooling with water set at 18 °C: 8.30 kW Power absorbed with water set at 7° C: 2.22 kW Power absorbed with water set at 18°C: 1.64 kW Water flow rate with water set at 7°C: 1281 l/h Water flow rate with water set at 18°C: 1428 l/h Technical data of external unit Compressor type : Twin Rotary DC Number of compressors : 1 Number of refrigeration circuits: 1 Fan type : DC Axial Number of fans: 1 Sound power level in heating : 55 ~ 61 dB(A) Sound power level in cooling : 54 ~ 61 dB(A) Liquid pipe diameter: 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Maximum pipe length: 30 m Maximum pipe height difference: 20 m Technical data of the internal unit Exchanger type: Brazed stainless steel plates Expansion vessel volume: 10 litres Water safety valve calibration: 3 bar Minimum system water content: 40 litres System pipe diameter: 1" gas F Diameter of ACS pipes: 3/4" gas F Liquid pipe diameter: 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Electrical Data Power supply (V,Hz,Ø) : 220~240/50/1 Refrigerant gas: R32 Dimensions and Weight External unit dimensions (WxHxD): 1118x865x523 mm External unit weight: 77.0 Kg Internal unit dimensions (WxHxD): 595x1860x700 mm 5 years without worries Ferroli OMNIA ST 3.2 Reversible air-water heat pumps for split installation, with integrated DHW storage Efficiency meets comfort for integrated storage OMNIA ST 3.2 is the evolution of OMNIA S 3.2 and is part of the new range of Full Inverter R32 split heat pumps by Ferroli. When we talk about “split” we mean that the refrigeration circuit is divided between the two units, the external one and the internal one. The external unit contains the heart of the refrigeration circuit, from the compressor to the fan with the air side exchanger, which is connected with the refrigerant gas pipes to the internal unit. The internal unit contains the heart of the generator's hydraulic circuit with all the main pre-installed components, such as the high-efficiency circulator and the expansion vessel, to allow for safe, practical and fast installation. The OMNIA ST 3.2 differs from the OMNIA S 3.2 in having an accumulation tank for Domestic Hot Water integrated directly into the internal unit. This accumulation is 190L for sizes 4 to 10, while it is 240L for the larger ones, from 12 to 16T. But not only that, OMNIA ST 3.2 can be customized according to your needs, with an 18L inertial kit, a kit for solar integration on the accumulation or with a kit for the management of 2 different zones, classic direct and mixed, in case we need 2 different temperatures on the terminals in the house Thanks to its wide operating range , among the widest on the market, OMNIA ST 3.2 works down to -25°C external and produces hot water up to 65°C in nominal conditions. The new Full Inverter concept by Ferroli uses DC inverter modulations on the 3 main energy-intensive components of the machine, namely compressor, fan and pump. This allows the power supplied to be modulated by finely tracking the thermal load and allowing the user very high efficiencies and significant energy savings . Furthermore, the Full Inverter concept by Ferroli allows the inrush currents to be reduced, avoiding surges in the network and guaranteeing a longer useful life for the components. With noise levels among the lowest on the market , OMNIA ST 3.2 is able to satisfy all system requirements, but can easily be integrated with a Ferroli boiler . The internal unit, the heart of the hydraulic distribution If the external unit contains the heart of the refrigeration circuit, the Internal Unit contains the heart of the hydraulic circuit. OMNIA ST 3.2 is much more than an exchanger with a pump. The hydronic module includes all the main components of the system and can be customized according to the user's needs. Stainless steel plate exchanger, pressure gauge and pressure sensors, expansion vessel, safety valve, automatic vent and brushless DC circulator are just some of the components you will find inside. The control system The User Interface has been equipped with Capsense technology with 2.8” graphic display, which allows the user to interact with the product in an easy and extremely simple way Modbus protocol It can be interfaced with BMS/BACS automation and management systems Heating and cooling Full Inverter modulation finely follows the desired setpoints, with the possibility of setting climatic curves in heating and cooling, further optimising the user's consumption Domestic hot water production When the DHW Temperature probe calls the machine it automatically diverts to the domestic hot water boiler with a dedicated DHW Setpoint. 3-way diverter valve supplied as standard Smart Grid Inputs from photovoltaic and grid Digital Smart Grid inputs for managing an input from a photovoltaic system and from the electricity grid. These allow you to optimise consumption and costs on your bill Electric heating element for ACS boiler The ACS electric integration serves as an integration, anti-legionella or reserve source in the event of an anomaly Fast ACS Priority to DHW production to bring the boiler to the setpoint in the shortest possible time Anti-legionella function Allows you to set weekly anti-legionella cycles Silent mode Reduces the compressor frequency and fan speed, thus significantly reducing noise. Programmable on time slots ON/OFF From external contact. Activation and deactivation via an external contact, for example from a zone thermostat Hot / cold From external contacts. Summer/winter switching signal from outside, e.g. from the zone thermostat ECO function Dedicated setpoint for “ Eco ” operation. Can be set with daily time slot Antifreeze protection Heat pump operation in heating mode with circulator ON and possible electric booster The brand new Connect CRP and Connect CRP Zone The on-board interface communicates easily with the new intelligent Connect CRP systems, which can manage up to 8 thermostats divided into 2 zones, one direct and one mixed . Connect CRP is the brand new remote controller accessible via APP , available for both iOS and Android . The Connect CRP Zone is a zone thermostat that communicates via RF with the Connect CRP. It can be inserted into a classic 502 box, or left stand-alone on its practical table feet. Product Warranty: All products for sale on our site are new and packaged. The warranty on this item is 24 months from the date of purchase.

    €5.200,00

  • immagine-1-ferroli-pompa-di-calore-splittata-reversibile-aria-acqua-inverter-ferroli-omnia-st-3.2-06-sistema-con-integrazione-elettrica-r-32-con-comando-incluso

    Ferroli Air-Water Reversible Split Heat Pump Inverter Ferroli Omnia St 3.2 06 System With R-32 Electrical Integration With Control Included

    ATTENTION! IN CASE OF UNAVAILABILITY IMMEDIATELY, THE PRODUCT WILL BE ORDERED AND SHIPPED WITHIN 10 WORKING DAYS   FIRST START-UP FREE Technical Features Model : OMNIA S 3.2 06 Product Code : 0XHT6SWA Command included Optional accessories CONNECT CRP remote control Performance Heating Useful power in heating with water set at 35° C: 6.35 kW Useful power in heating with water set at 45° C: 6.30 kW Useful power in heating with water set at 55° C: 6.00 kW Power absorbed with water set at 35° C: 1.28 kW Power absorbed with water set at 45°C: 1.70 kW Power absorbed with water set at 55°C: 2.03 kW Water flow rate with water set at 35°C: 1092 l/h Water flow rate with water set at 45°C: 1074 /h Water flow rate with water set at 55°C: 645 l/h Cooling Useful power in cooling with water set at 7 °C: 6.50 kW Useful power in cooling with water set at 18 °C: 6.50 kW Power absorbed with water set at 7° C: 2.17 kW Power absorbed with water set at 18°C: 1.35 kW Water flow rate with water set at 7°C: 1118 l/h Water flow rate with water set at 18°C: 1118 l/h Technical data of external unit Compressor type : Twin Rotary DC Number of compressors : 1 Number of refrigeration circuits: 1 Fan type : DC Axial Number of fans: 1 Sound power level in heating mode : 53 ~ 61 dB(A) Sound power level in cooling : 54 ~ 61 dB(A) Liquid pipe diameter: 6.35 mm (1/4") Gas pipe diameter: 15.88 (5/8") Maximum pipe length: 30 m Maximum pipe height difference: 20 m Technical data of the internal unit Exchanger type: Brazed stainless steel plates Expansion vessel volume: 10 litres Water safety valve calibration: 3 bar Minimum system water content: 40 litres System pipe diameter: 1" gas F Diameter of ACS pipes: 3/4" gas F Liquid pipe diameter: 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Electrical Data Power supply (V,Hz,Ø) : 220~240/50/1 Refrigerant gas: R32 Dimensions and Weight External unit dimensions (WxHxD): 1008x712x426 mm External unit weight: 58.0 Kg Internal unit dimensions (WxHxD): 595x1860x700 mm 5 years without worries Ferroli OMNIA ST 3.2 Reversible air-water heat pumps for split installation, with integrated DHW storage Efficiency meets comfort for integrated storage OMNIA ST 3.2 is the evolution of OMNIA S 3.2 and is part of the new range of Full Inverter R32 split heat pumps by Ferroli. When we talk about “split” we mean that the refrigeration circuit is divided between the two units, the external one and the internal one. The external unit contains the heart of the refrigeration circuit, from the compressor to the fan with the air side exchanger, which is connected with the refrigerant gas pipes to the internal unit. The internal unit contains the heart of the generator's hydraulic circuit with all the main pre-installed components, such as the high-efficiency circulator and the expansion vessel, to allow for safe, practical and fast installation. The OMNIA ST 3.2 differs from the OMNIA S 3.2 in having an accumulation tank for Domestic Hot Water integrated directly into the internal unit. This accumulation is 190L for sizes 4 to 10, while it is 240L for the larger ones, from 12 to 16T. But not only that, OMNIA ST 3.2 can be customized according to your needs, with an 18L inertial kit, a kit for solar integration on the accumulation or with a kit for the management of 2 different zones, classic direct and mixed, in case we need 2 different temperatures on the terminals in the house Thanks to its wide operating range , among the widest on the market, OMNIA ST 3.2 works down to -25°C external and produces hot water up to 65°C in nominal conditions. The new Full Inverter concept by Ferroli uses DC inverter modulations on the 3 main energy-consuming components of the machine, i.e. compressor, fan and pump. This allows the power supplied to be modulated by finely tracking the thermal load and allowing the user very high efficiencies and significant energy savings . Furthermore, the Full Inverter concept by Ferroli allows the inrush currents to be reduced, avoiding surges in the network and guaranteeing a longer useful life for the components. With noise levels among the lowest on the market , OMNIA ST 3.2 is able to satisfy all system requirements, but can easily be integrated with a Ferroli boiler . The internal unit, the heart of the hydraulic distribution If the external unit contains the heart of the refrigeration circuit, the Internal Unit contains the heart of the hydraulic circuit. OMNIA ST 3.2 is much more than an exchanger with a pump. The hydronic module includes all the main components of the system and can be customized according to the user's needs. Stainless steel plate exchanger, pressure gauge and pressure sensors, expansion vessel, safety valve, automatic vent and brushless DC circulator are just some of the components you will find inside. The control system The User Interface has been equipped with Capsense technology with 2.8” graphic display, which allows the user to interact with the product in an easy and extremely simple way Modbus protocol It can be interfaced with BMS/BACS automation and management systems Heating and cooling Full Inverter modulation finely follows the desired setpoints, with the possibility of setting climatic curves in heating and cooling, further optimising the user's consumption Domestic hot water production When the DHW Temperature probe calls the machine it automatically diverts to the domestic hot water boiler with a dedicated DHW Setpoint. 3-way diverter valve supplied as standard Smart Grid Inputs from photovoltaic and grid Digital Smart Grid inputs for managing an input from a photovoltaic system and from the electricity grid. These allow you to optimise consumption and costs on your bill Electric heating element for ACS boiler The ACS electric integration serves as an integration, anti-legionella or reserve source in the event of an anomaly Fast ACS Priority to DHW production to bring the boiler to the setpoint in the shortest possible time Anti-legionella function Allows you to set weekly anti-legionella cycles Silent mode Reduces the compressor frequency and fan speed, thus significantly reducing noise. Programmable on time slots ON/OFF From external contact. Activation and deactivation via an external contact, for example from a zone thermostat Hot / cold From external contacts. Summer/winter switching signal from outside, e.g. from the zone thermostat ECO function Dedicated setpoint for “ Eco ” operation. Can be set with daily time slot Antifreeze protection Heat pump operation in heating mode with circulator ON and possible electric booster The brand new Connect CRP and Connect CRP Zone The on-board interface communicates easily with the new intelligent Connect CRP systems, which can manage up to 8 thermostats divided into 2 zones, one direct and one mixed . Connect CRP is the brand new remote controller accessible via APP , available for both iOS and Android . The Connect CRP Zone is a zone thermostat that communicates via RF with the Connect CRP. It can be inserted into a classic 502 box, or left stand-alone on its practical table feet. Product Warranty: All products for sale on our site are new and packaged. The warranty on this item is 24 months from the date of purchase.

    €5.000,00

  • immagine-1-ferroli-pompa-di-calore-reversibile-aria-acqua-inverter-ferroli-omnia-s-3.2-16-monofase-r-32-con-comando-incluso

    Ferroli Reversible Air-Water Inverter Heat Pump Ferroli OMNIA S 3.2 16 Single Phase R-32 with Control Included

    ATTENTION! IN CASE OF UNAVAILABILITY IMMEDIATELY, THE PRODUCT WILL BE ORDERED AND SHIPPED WITHIN 10 WORKING DAYS   FIRST START-UP FREE Technical Features Model : OMNIA S 3.2 16 Product Code : 0XHKGSWA Command included Optional accessories Unpainted built-in cabinet 016092X0 Painted built-in wardrobe 016093X0 Optional accessories Unpainted built-in cabinet 016092X0 Painted built-in wardrobe 016093X0 Energy Efficiency Energy class in heating at 35° C: A+++ Energy class in heating at 55° C: A++ SCOP heating with water set to 35 °C: 4.62 SEER cooling with water set at 7 °C: 4.69 Performance   Heating Useful power in heating with water set at 35° C: 15.9 kW Useful power in heating with water set at 45° C: 16.0 kW Useful power in heating with water set at 55° C: 16.0 kW Power absorbed with water set at 35°C: 3.53 kW Power absorbed with water set at 45°C: 4.57 kW Power absorbed with water set at 55°C: 5.61 kW Water flow rate with water set at 35°C: 2735 l/h Water flow rate with water set at 45°C: 2752 /h Water flow rate with water set at 55°C: 1720 l/h Cooling Useful power in cooling with water set at 7 °C: 14.0 kW Useful power in cooling with water set at 18 °C: 13.6 kW Power absorbed with water set at 7° C: 5.60 kW Power absorbed with water set at 18°C: 3.77 kW Water flow rate with water set at 7°C: 2408 l/h Water flow rate with water set at 18°C: 2563 l/h Technical data of external unit Compressor type : Twin Rotary DC Number of compressors : 1 Number of refrigeration circuits: 1 Fan type : DC Axial Number of fans: 1 Sound power level in heating mode : 56 ~ 69 dB(A) Sound power level in cooling : 56 ~ 69 dB(A) Liquid pipe diameter: 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Maximum pipe length: 30 m Maximum pipe height difference: 20 m Technical data of the internal unit Exchanger type: Brazed stainless steel plates Expansion vessel volume: 10 litres Water safety valve calibration: 3 bar Minimum system water content: 40 litres System pipe diameter: 1" gas F Diameter of ACS pipes: 3/4" gas F Liquid pipe diameter: 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Electrical Data Power supply (V,Hz,Ø) : 220~240/50/1 Refrigerant gas: R32 Dimensions and Weight External unit dimensions (WxHxD): 1118x865x523 mm External unit weight: 96.0 Kg Internal unit dimensions (WxHxD): 422x702x320 mm 5 years without worries Ferroli OMNIA S 3.2 Reversible heat pumps for split installation with DC inverter compressor Silence, efficiency and design OMNIA S 3.2 is the new range of split heat pumps Full Inverter R32 by Ferroli. The range includes an External Unit with the heart of the refrigeration circuit, from the compressor to the fan with the air-side exchanger, which is connected to the refrigerant gas pipes towards the Internal Unit. The Internal Unit instead contains the heart of the generator's hydraulic circuit with all the main pre-installed components, such as the high-efficiency circulator and the expansion vessel, to allow safe, practical and fast installation The split installation of OMNIA S 3.2 , with only gas pipes between the external and internal unit, is synonymous with safety with respect to any freezing problem, even at the most rigid temperatures (up to -25°C) and in the absence of electricity. All the units satisfy the most extreme winter and summer air conditioning needs, in fact they can produce hot water up to 65°C , which makes them suitable for practically all heating systems, whether radiant, fan coil or radiator, including the production of domestic hot water (DHW), via an external boiler The new concept Ferroli Full Inverter uses DC inverter modulations on the 3 main energy-consuming components of the machine, namely compressor, fan and pump. This allows the power supplied to be modulated by finely tracking the thermal load and allowing the user extremely high efficiencies and significant energy savings . Furthermore, the concept Ferroli Full Inverter guarantees noise levels among the lowest on the market, avoiding power surges and guaranteeing a longer useful life for the components. Internal and external unit of OMNIA 3.2 The External Unit contains the heart of the refrigeration circuit, while the Internal Unit the heart of the hydraulic circuit. They are connected to each other by pipes ecological refrigerant gas R32 , which has allowed us to combine high efficiency with a reduced environmental impact. Thanks to its GWP of 675 , about a third of the GWP of R410a, helps reduce CO2 equivalent emissions, the main cause of global warming The heat pumps they use the External Unit to extract heat from the air outside the home and convey it to the water in your system, via an exchanger in the Internal Unit. This is precisely why they are able to obtain such high efficiencies , exploiting in a way renewable the energy already present in the air outside the home The new concept Ferroli Full Inverter then does the rest, tracking the thermal loads precisely and without waste (modulating the compressor, pump and fan), managing to achieve even greater efficiencies, guaranteeing significant savings on your bill , without stressing your components and with very low noise levels OMNIA S 3.2 it can be used either as the only generator in the system or integrated with other sources such as a Ferroli boiler The control system The User Interface has been equipped with Capsense technology with 2.8” graphic display, which allows the user to interact with the product in an easy and extremely simple way Modbus protocol It can be interfaced with BMS/BACS automation and management systems Heating and cooling Full Inverter modulation finely follows the desired setpoints, with the possibility of setting climatic curves in heating and cooling, further optimising the user's consumption Domestic hot water production When the DHW Temperature probe calls the machine it automatically diverts to the domestic hot water boiler with a dedicated DHW Setpoint. 3-way diverter valve supplied as standard Smart Grid Inputs from photovoltaic and grid Digital Smart Grid inputs for managing an input from a photovoltaic system and from the electricity grid. These allow you to optimise consumption and costs on your bill Electric heating element for ACS boiler The ACS electric integration serves as an integration, anti-legionella or reserve source in the event of an anomaly Fast ACS Priority to DHW production to bring the boiler to the setpoint in the shortest possible time Anti-legionella function Allows you to set weekly anti-legionella cycles Silent mode Reduces the compressor frequency and fan speed, thus significantly reducing noise. Programmable on time slots ON/OFF From external contact. Activation and deactivation via an external contact, for example from a zone thermostat Hot / cold From external contacts. Summer/winter switching signal from outside, e.g. from the zone thermostat ECO function Dedicated setpoint for “ Eco ” operation. Can be set with daily time slot Antifreeze protection Heat pump operation in heating mode with circulator ON and possible electric booster Product Warranty: All products for sale on our site are new and packaged. The warranty on this item is 24 months from the date of purchase.

    €5.540,00

  • immagine-1-ferroli-pompa-di-calore-reversibile-aria-acqua-inverter-ferroli-omnia-s-3.2-12-trifase-r-32-con-comando-incluso

    Ferroli Air-Water Reversible Heat Pump Inverter Ferroli Omnia S 3.2 12 Three-Phase R-32 With Control Included

    ATTENTION! IN CASE OF UNAVAILABILITY IMMEDIATELY, THE PRODUCT WILL BE ORDERED AND SHIPPED WITHIN 10 WORKING DAYS   FIRST START-UP FREE Technical Features Model : OMNIA S 3.2 12-T Product Code : 0XHLCSWA Command included Optional accessories Unpainted built-in cabinet 016092X0 Painted built-in wardrobe 016093X0 Optional accessories Unpainted built-in cabinet 016092X0 Painted built-in wardrobe 016093X0 Energy Efficiency Energy class in heating at 35° C: A+++ Energy class in heating at 55° C: A++ SCOP heating with water set to 35 °C: 4.81 SEER cooling with water set at 7 °C: 4.86 Performance   Heating Useful power in heating with water set at 35° C: 12.1 kW Useful power in heating with water set at 45° C: 12.3 kW Useful power in heating with water set at 55° C: 11.9 kW Power absorbed with water set at 35°C: 2.44 kW Power absorbed with water set at 45°C: 3.32 kW Power absorbed with water set at 55°C: 3.90 kW Water flow rate with water set at 35°C: 2081 l/h Water flow rate with water set at 45°C: 2116 /h Water flow rate with water set at 55°C: 1279 l/h Cooling Useful power in cooling with water set at 7 °C: 11.5 kW Useful power in cooling with water set at 18 °C: 12.0 kW Power absorbed with water set at 7° C: 4.18 kW Power absorbed with water set at 18°C: 3.04 kW Water flow rate with water set at 7°C: 1978 l/h Water flow rate with water set at 18°C: 2064 l/h Technical data of external unit Compressor type : Twin Rotary DC Number of compressors : 1 Number of refrigeration circuits: 1 Fan type : DC Axial Number of fans: 1 Sound power level in heating : 56 ~ 65 dB(A) Sound power level in cooling : 56 ~ 69 dB(A) Liquid pipe diameter: 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Maximum pipe length: 30 m Maximum pipe height difference: 20 m Technical data of the internal unit Exchanger type: Brazed stainless steel plates Expansion vessel volume: 10 litres Water safety valve calibration: 3 bar Minimum system water content: 40 litres System pipe diameter: 1" gas F Diameter of ACS pipes: 3/4" gas F Liquid pipe diameter: 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Electrical Data Power supply (V,Hz,Ø) : 380~415/50/3 Refrigerant gas: R32 Dimensions and Weight External unit dimensions (WxHxD): 1118x865x523 mm External unit weight: 112.0 Kg Internal unit dimensions (WxHxD): 422x702x320 mm 5 years without worries Ferroli OMNIA S 3.2 Reversible heat pumps for split installation with DC inverter compressor Silence, efficiency and design OMNIA S 3.2 is the new range of split heat pumps Full Inverter R32 by Ferroli. The range includes an External Unit with the heart of the refrigeration circuit, from the compressor to the fan with the air-side exchanger, which is connected to the refrigerant gas pipes towards the Internal Unit. The Internal Unit instead contains the heart of the generator's hydraulic circuit with all the main pre-installed components, such as the high-efficiency circulator and the expansion vessel, to allow safe, practical and fast installation The split installation of OMNIA S 3.2 , with only gas pipes between the external and internal unit, is synonymous with safety with respect to any freezing problem, even at the most rigid temperatures (up to -25°C) and in the absence of electricity. All the units satisfy the most extreme winter and summer air conditioning needs, in fact they can produce hot water up to 65°C , which makes them suitable for practically all heating systems, whether radiant, fan coil or radiator, including the production of domestic hot water (DHW), via an external boiler The new concept Ferroli Full Inverter uses DC inverter modulations on the 3 main energy-consuming components of the machine, namely compressor, fan and pump. This allows the power supplied to be modulated by finely tracking the thermal load and allowing the user extremely high efficiencies and significant energy savings . Furthermore, the concept Ferroli Full Inverter guarantees noise levels among the lowest on the market, avoiding power surges and guaranteeing a longer useful life for the components. Internal and external unit of OMNIA 3.2 The External Unit contains the heart of the refrigeration circuit, while the Internal Unit the heart of the hydraulic circuit. They are connected to each other by pipes ecological refrigerant gas R32 , which has allowed us to combine high efficiency with a reduced environmental impact. Thanks to its GWP of 675 , about a third of the GWP of R410a, helps reduce CO2 equivalent emissions, the main cause of global warming The heat pumps they use the External Unit to extract heat from the air outside the home and convey it to the water in your system, via an exchanger in the Internal Unit. This is precisely why they are able to obtain such high efficiencies , exploiting in a way renewable the energy already present in the air outside the home The new concept Ferroli Full Inverter then does the rest, tracking the thermal loads precisely and without waste (modulating the compressor, pump and fan), managing to achieve even greater efficiencies, guaranteeing significant savings on your bill , without stressing your components and with very low noise levels OMNIA S 3.2 it can be used either as the only generator in the system or integrated with other sources such as a Ferroli boiler The control system The User Interface has been equipped with Capsense technology with 2.8” graphic display, which allows the user to interact with the product in an easy and extremely simple way Modbus protocol It can be interfaced with BMS/BACS automation and management systems Heating and cooling Full Inverter modulation finely follows the desired setpoints, with the possibility of setting climatic curves in heating and cooling, further optimising the user's consumption Domestic hot water production When the DHW Temperature probe calls the machine it automatically diverts to the domestic hot water boiler with a dedicated DHW Setpoint. 3-way diverter valve supplied as standard Smart Grid Inputs from photovoltaic and grid Digital Smart Grid inputs for managing an input from a photovoltaic system and from the electricity grid. These allow you to optimise consumption and costs on your bill Electric heating element for ACS boiler The ACS electric integration serves as an integration, anti-legionella or reserve source in the event of an anomaly Fast ACS Priority to DHW production to bring the boiler to the setpoint in the shortest possible time Anti-legionella function Allows you to set weekly anti-legionella cycles Silent mode Reduces the compressor frequency and fan speed, thus significantly reducing noise. Programmable on time slots ON/OFF From external contact. Activation and deactivation via an external contact, for example from a zone thermostat Hot / cold From external contacts. Summer/winter switching signal from outside, e.g. from the zone thermostat ECO function Dedicated setpoint for “ Eco ” operation. Can be set with daily time slot Antifreeze protection Heat pump operation in heating mode with circulator ON and possible electric booster Product Warranty: All products for sale on our site are new and packaged. The warranty on this item is 24 months from the date of purchase.

    €5.345,00

  • Caldaia A Condensazione Ferroli Divacondens D Plus F24 Low Nox Metano Completo Di Kit Scarico Fumi - CaldaieMurali

    Ferroli Ferroli DIVACONDENS D PLUS F24 LOW NOx Methane Condensing Boiler Complete with Flue Exhaust Kit

    ATTENTION ! The boiler will be supplied with methane, for LPG operation you must contact your local Authorized Assistance Centre. Technical features Model : Divacondens D Plus Nominal thermal power: 24 kW Power supply: methane Specifications Energy efficiency according to the European ErP directive Heating Energy Efficiency Class: B Seasonal Space Heating Energy Efficiency : 89% Performance Heating Thermal Capacity : 7,5 ~ 25,0 kW Heating Thermal Power: 7.2 ~ 24.2 kW Ultimate Thermal Efficiency 30% Pmin : 100.1% Domestic Hot Water Production 25°C Δt 30°C : 13,9 ~ 11,6 l/min NOx emissions 6 Dimensions and weight Dimensions (LxHxP): 400x700x330 mm Weight : 35Kg Ferroli Divacondens D Plus Boiler The Simplest Solution For A Condensing Boiler DIVACONDENS D PLUS is the condensing heat generator for traditional heating systems. The tried and tested Ferroli technology in the field of traditional wall mounted boilers has been enriched by increasing the performance of the product in the simplest way, with the use of a robust recuperator which preheats the primary circuit using the residual heat of the exhaust fumes and a new cooled burner with low NOx emissions. The Range Divacondens D Plus is offered in a single model for heating and instantaneous production of domestic hot water Characteristics > Condensing boiler for heating high temperature systems and producing domestic hot water. It is not suitable for combination with direct delivery to systems with low temperature radiant panels > Compact geometry primary exchanger > Instant production of domestic hot water with dedicated plate exchanger > Post-recovery of the latent heat of condensation, in function of pre-heating of the primary circuit > Forced draught sealed chamber boiler, with water-cooled atmospheric burner with low NOx emissions > Standard automatic hydraulic by-pass > Minimum polluting emissions (class 6 according to EN 15502-1) > High efficiency low consumption circulator (ErP - Class A) with anti-blocking system by activation for a few seconds every 24 hours of inactivity > Can be combined with the modulating remote timer control > Simple and complete control panel, display user interface, with setting keys > Robust post-condenser fed by the closed circuit of the primary. The heat exchange with the fumes takes place inside large diameter water passages. > Generator with simple and rational operation > ECO function in DHW for greater savings in the period of low use of hot water > Predisposition for solar systems: prearranged for the production of domestic hot water combined with solar panel systems > Place of installation: also for outdoors in a partially protected place down to -5°C as standard > Certified operation also with propane air (50% air - 50% G31) by means of a specific transformation to be requested from the Authorized Assistance Center > Also works on LPG with the use of a special conversion kit to be requested from the Authorized Assistance Centre Boiler control The DIVACONDENS D PLUS control unit consists of an easy-to-use interface with a backlit display. Using the buttons, it is possible to easily adjust the heating flow temperature, the domestic hot water setpoint, switch the generator on/off or activate the comfort function, monitoring the status of the boiler. The control panel is completed by a traditional pressure gauge which can check the system pressure at any time. The performances Energy classification DHW load profile (maximum flow rate at the corresponding efficiency declared in DHW) Efficiency in the production of domestic hot water FOR COMBINED BOILERS The "climate-energy 20/20/20" package sets ambitious targets for the reduction of greenhouse gas emissions, of energy consumption as well as the increase in the use of renewable energies, corresponding to a percentage of 20% to be reached by 2020. In this context, the European regulation ErP (Energy Related Products) introduces an energy classification also for water generators hot water for space heating and domestic hot water purposes. This classification translates into an energy label which must necessarily accompany all the products affected by the Regulation, introduced on the market from 26 September 2015. The labeling constitutes an easy guide for the consumer, who can choose - through standardized and objective indications - the product more efficient. In this way, the choice will be the most sparing in terms of consumption for the benefit of the user, but also the most virtuous for energy balances and consequently, for the environment. The most significant parameters indicated on the label are the seasonal efficiency index in heating and efficiency in the eventual production of domestic hot water, according to a scale which, in the case of the single boiler product, ranges from A to G*. Furthermore, for combined boilers, a load profile is indicated corresponding to the DHW flow rate of the appliance measured in a series of typical samplings, guaranteeing at least the declared DHW efficiency. This index is identified with a letter/”size” (S, M …XXL). Solar circuit integration DIVACONDENS D PLUS boasts electronics that simplify integration with thermal solar systems, both with natural and forced circulation. The microprocessor controls the temperature of the water coming from the solar circuit through the domestic hot water sensor and switches on the burner only if necessary. To reach the desired temperature, SUN EASY allows considerable savings even during the coldest seasons, exploiting and integrating even the smallest solar contribution, otherwise lost. In case of insufficient irradiation and therefore a modest pre-heating of the domestic water, the boiler will contribute with the heat necessary to reach the required set point temperature. If the sun and the solar system fulfill their "duty" no integration by the boiler will be necessary, the hot water will be conveyed to the tap, without the need for additional devices, with the mixing of the thermostatic valves. Safety and comfort ANTIFREEZE In the event that the temperature in the boiler drops to 5°C, the burner ignites automatically and the circulator is activated in order to protect the appliance from damage caused by frost. This function is active with the boiler powered by the gas circuit and under electrical voltage. POST-CIRCULATION This function makes it possible to recover all the heat supplied by thermal inertia of the exchanger and transfer it to the heating system, and consequently to the rooms to be heated. This is a timer function (customizable duration) and is active after the burner goes out in heating mode. SLIDING TEMPERATURE OPERATION With the installation of the “external probe” kit it is possible to operate the boiler in sliding temperature. This means that without using the system temperature adjustment keys, the boiler will self-regulate according to the variations in external temperatures. All this translates into energy savings while ensuring maximum comfort for the user. EASY CONTROL The electronic board of DIVACONDENS D PLUS adopts the Opentherm protocol. It allows the integration of other peripheral control units such as, for example, the ROMEO remote timer control. In fact, the Opentherm standard has been specially designed to share the logic and operating algorithms of the boiler with other additional control units. As a digital protocol, it allows total integration between the boiler and the satellite, with full control of the functions from the boiler and similarly from its satellite. Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €580,00

  • Caldaia A Condensazione Ferroli Divacondens D Plus F24 Low Nox Metano Completo Di Kit Scarico Fumi - CaldaieMurali

    Ferroli Ferroli Divacondens D Plus F24 Low Nox Methane Condensing Boiler Complete With Smoke Exhaust Kit

    FERROLI DIVACONDENS D F24 METHANE CONDENSING GAS BOILER COMPLETE WITH FUME EXHAUST KIT-NEW ERP Technical features Energy label specifications according to the European ErP directive Class B heating energy efficiency Sanitary energy efficiency profile XL Class A Characteristics of heating/DHW operation: Heating max heat input kW 25.8 Nominal thermal power Pn kW 24 Efficiency Pmax (80/60°C) % 96.5 Yield 30% % 103.5 Directive efficiency class 92/42 EEC **** Max heating / sanitary operating pressure. bars 3 / 9 Max heating temperature 90 °C Heating water content liters 1.5 Heating expansion tank capacity 8 litres Exp. vessel preload pressure heating bar 1 Sanitary water content 0.3 litres Sanitary flow rate ∆t 25°C l/min 14.0 Sanitary flow rate ∆t 30°C l/min 11.6 IP X5D degree of protection Electric power absorbed W 95 Extremely compact dimensions (LxHxP): mm 400x700x330; 35kg Sound power level LWA dB 57 NOx class 3 Power supply: METHANE DIVA CONDENS D DIVACONDENS D is the condensing heat generator for traditional heating systems. The tried and tested Ferroli technology in the field of traditional wall mounted boilers has been enriched by increasing the performance of the product in the simplest way, with the use of a robust recuperator which preheats the primary circuit using the residual heat of the exhaust fumes. The quality of the DIVACONDENS line is unquestionable, and Ferroli is ready to put it to the test by offering its customers an extended warranty coverage with the "5 years worry-free" formula which also ensures periodic maintenance and legal checks. Range Divacondens D is available in two models for heating and instantaneous production of domestic hot water forced draft boiler and sealed chamber mod. F 24 - MAXIMUM THERMAL CAPACITY 25.0 kW mod. F 28 - MAXIMUM THERMAL CAPACITY 28.0 kW Strengths: Condensing boiler for heating high temperature systems and producing domestic hot water. It is not suitable for combination with direct delivery to systems with low temperature radiant panels Compact geometry primary heat exchanger entirely in copper Instant production of domestic hot water with dedicated plate exchanger Post-recovery of the latent heat of condensation, in function of pre-heating of the primary circuit Forced draught sealed chamber boiler, with AISI 304 stainless steel atmospheric burner Standard hydraulic by-pass High efficiency low consumption circulator (ErP - Class A) with anti-blocking system by activation for a few seconds every 24 hours of inactivity Can be combined with the modulating remote timer control Simple and complete control panel, display user interface, with setting keys Advantages of Divacondens D: Robust post-condenser powered by the closed circuit of the primary circuit, i.e. without the inlet of external mains water. The heat exchange with the fumes takes place inside large diameter water passages. Generator with simple and rational operation Condensate collection device to protect the air pressure switch, for regular combustion even in the presence of very cold external temperatures ECO function in DHW for greater savings in the period of low use of hot water Predisposition for solar systems: prepared for the production of domestic hot water combined with solar panel systems Place of installation: also for outdoors in a partially protected place down to -5°C as standard Certified operation also with propane air (50% air - 50% G31) by means of a specific transformation to be requested from the Authorized Assistance Center (max total price of 30 euros + VAT) Also works on LPG with the use of a special conversion kit to be requested from the Authorized Assistance Centre. Free transformation during product verification and activation of the guarantee only if the specific code running on LPG is not available. Functions: ANTIFREEZE In the event that the temperature in the boiler drops to 5°C, the burner ignites automatically and the circulator is activated in order to protect the appliance from damage caused by frost. This function is active with the boiler powered by the gas circuit and under electrical voltage. POST-CIRCULATION This function makes it possible to recover all the heat supplied by thermal inertia of the exchanger and transfer it to the heating system, and consequently to the rooms to be heated. This is a timer function (customizable duration) and is active after the burner goes out in heating mode. SLIDING TEMPERATURE OPERATION With the installation of the “external probe” kit it is possible to operate the boiler in sliding temperature. This means that without using the system temperature adjustment keys, the boiler will self-regulate according to the variations in external temperatures. All this translates into energy savings while ensuring maximum comfort for the user. EASY CONTROL The DIVACONDENS D electronic board adopts the Opentherm protocol. It allows the integration of other peripheral control units such as, for example, the ROMEO remote timer control. In fact, the Opentherm standard has been specially designed to share the logic and operating algorithms of the boiler with other additional control units. As a digital protocol, it allows total integration between the boiler and the satellite, with full control of the functions from the boiler and similarly from its satellite CONTROL UNIT The DIVACONDENS D control unit consists of an easy to use interface with a backlit display. Using the buttons, it is possible to easily adjust the heating flow temperature, the domestic hot water setpoint, switch the generator on/off or activate the comfort function, monitoring the status of the boiler. The control panel is completed by a traditional pressure gauge which can check the system pressure at any time. COMBINABLE WITH THE ROMEO CHRONO CONTROL: The Romeo chrono control allows control and setting of the boiler functions directly from the room in which it is installed. Comfort programming is possible on a weekly basis and also includes the 'holiday' function. Romeo is available with wired or wireless connection. The ROMEO modulating function allows boiler output to be modulated as the set room temperature value is reached. This improves the quality of comfort by eliminating heat peaks with consequent energy savings. Product Guarantee All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €575,00 - €580,00

  • immagine-1-ferroli-climatizzatore-condizionatore-ferroli-dual-split-inverter-serie-ambra-m-99-con-18-2-r-32-wi-fi-integrato-90009000-novita

    FERROLI Air Conditioner Ferroli Dual Split Inverter Ambra M 9+9 Series With 18-2 R-32 Integrated Wi-Fi 9000+9000 - New

    Technical features Indoor units: 1) Model: Indoor unit catalog code : Amber M 25 (x2) Power (BTU/h) 9000 Indoor Unit HxWxD (mm): 285 x 805 x 194 ; 7.5kg Outdoor Unit: Model: Outdoor unit catalog code : 18-2 Energy efficiency: SEER/SCOP (W/W): 6.1/3.80 Energy Efficiency Class (cooling) : A++ Energy Efficiency Class (heating): A Performance: Nominal cooling capacity (kW): 5.3 Nominal heating capacity (kW): 5.6 Min-max outdoor unit sound pressure (dB-A): 54 Nominal sound power dB(A): 65 Characteristics: Power supply (V/Hz/F): 220/240 - 50 - 1 Phase Refrigerant gas : R-32 Dimensions: HxWxD (mm) : 554 x 800 (70) x 333; 35 kg AMBER M > GENERAL FEATURES: - Ecological refrigerant R32 - Class of Efficiency A++ and A+++ - Double filtering with “Cold Catalyst” and “Biohepa” - Remote control with dedicated smartphone App - Temperature visualization on the display on the machine - Equipped with DC inverter technology - Indoor unit with a particularly attractive and modern design - External unit equipped with connection cap and soundproof hood - Easily removable suction grille and filters for quick cleaning - Automatic reset in case of voltage drop - Night operating mode - "AUTOMATIC" operating mode - Timer function - Outdoor unit treated with anti-rust protective substances - Wi-Fi connectivity as standard THERE IS NEW AIR IN FERROLI Thanks to the optimized refrigerant circuit and the regulation that modulates the compressor with DC inverter technology, these machines are able to precisely and punctually follow your temperature setpoints, both in hot and cold. This translates into reduced noise, maximum comfort and top efficiency, saving you kilowatt hours of electricity on your bill. The mono-split versions of Ambra, for example, never go below class A++. Furthermore, they use R32 refrigerant, an ecologically more sustainable gas: it does not affect the ozone layer and has a GWP of about a third compared to the more classic R410A. All Ambras can then connect to your Wi-Fi, as standard, without expensive accessories. Thanks to our free App, you can manage and program them easily and remotely. But that's not all, a double stage of filtration and an advanced treatment for the external battery are also included to protect it for a long time from atmospheric agents. With regard to air quality, Ambra air conditioners, both in the Mono and Multi Split versions, are fitted with a double filtration stage, consisting of a "Cold Catalyst" filter plus a "Biohepa" filter. Col Catalyst Filter: This filter has active action against volatile organic compounds (TVOC), formaldehyde, ammonia, and sulfuric acid (or hydrogen sulphide). Biohepa filter: This filter instead manages to filter very small dust particles, bacteria and fungi; made up of special enzymes, it counteracts its proliferation. LIMITS ON LENGTH AND DIFFERENCE IN LEVEL OF REFRIGERANT PIPES   The length of the refrigerant pipes between the indoor and outdoor units must be as short as possible, and is in any case limited by respecting the maximum height difference values ​​between the units. By decreasing the difference in height between the units (H1,H2) and the length of the pipes (L), the load losses will be limited, consequently increasing the overall efficiency of the machine. Respect the limits shown in the following tables. Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €665,00

  • immagine-1-ferroli-scaldabagno-a-gas-ferroli-sky-eco-11f-low-nox-completo-di-kit-fumi-gpl-novita-ean-8055776919010

    Ferroli Ferroli Sky Eco 11f Low Nox Gas Water Heater Complete With LPG Fume Kit - New

    Ferroli SKY ECO 11F Low NOx gas water heater complete with LPG fume kit - NEW ERP Class (Class G - A) A XL load profile Nominal heat input Max kW 21.7 Thermal power Max / Min kW 19.5 / 5.5 Maximum working pressure 10 bar Maximum DHW production Δt 25°C / Δt 30°C l/min 11.2 / 9.3 Power supply V/Hz 230 / 50; 14 Kgs New Ferroli ECO range EFFECTIVE The ECO range has been designed according to the stringent efficiency parameters of the European ErP Directive. In practice, they are able to produce a lot of hot water at a low cost, respecting the environment and with minimal polluting emissions. They can also be integrated into a solar thermal system with extreme simplicity for maximum efficiency and comfort. EASY ECO water heaters are extremely simple to install and are interchangeable with previous series. Although very compact in size, they have been designed and built in such a way as to have easy access to the internal components for easy maintenance. BEAUTIFUL AND SMART The designers of the ECO project have created a «friendly» aesthetic that can be easily integrated with the most diverse furnishing styles. The knob or button controls have been designed to be easy to use and immediately understood. All Ferroli gas water heaters are equipped with a user interface display. Sky ECO F Sealed chamber gas water heater, with modulating thermal power and electronic control of the. Combustion. LOW NOx fume emission and SUN EASY system for direct coupling to a solar thermal system SUN EASY Easy... Cheap... Brilliant The SKY ECO range has been designed to be easily integrated with thermal solar systems, with natural or forced circulation. The temperature of the water coming from the solar circuit is constantly monitored and the water heater burner is turned on only if it is not hot enough. To reach the desired temperature, SUN EASY allows considerable savings even during the coldest seasons, exploiting and integrating even the smallest solar contribution, otherwise lost. The heart of water heaters All ECO series water heaters comply with the very strict restrictions on the emission of fumes into the atmosphere, imposed by European regulations. The burners in the ECO range use a particular technology which consists in keeping the flame temperature very low, keeping the gas trains wet. This expedient makes it possible to go well below the limits imposed by the ErP directive which sets the NOx limit at the threshold of 56 mg/kWh. Copper exchanger Interface displays Continuous power modulation - Available for operation with Natural Gas, LPG and Propane Air (50% air - 50% G31 by means of a specific transformation to be requested from the authorized assistance center at the maximum total price of 30 euros + VAT) Solar installations Also outdoor installation in protected places Product Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase

    €372,00

  • Caldaia A Camera Aperta Ferroli Divatech D Ln C 30 Low Nox Metano O Gpl - New Erp - CaldaieMurali

    Ferroli Open Chamber Boiler Ferroli Divatech D Ln C 30 Low Nox Methane Or Lpg - New Erp

    The boiler is supplied with methane. Transformation of methane/LPG/Propaned air to be requested in advance from the Authorized Assistance Centre Technical features Model : Divatech D LNC 30 Product code : 0DCC6YWA Power supply: methane / LPG Energy efficiency Heating energy efficiency class: C Sanitary energy efficiency class: A ACS profile : XL Performance Heating nominal heat output : 11.1 ~ 30.0 kW Heat output : 12.6 ~ 33.0 kW Domestic useful thermal power: 30.0 kW Efficiency : 91.0 % Maximum production of domestic hot water Δt 25°C : 17.2 l/min Maximum production of domestic hot water Δt 30°C : 14.3 l/min NOx : 6 Dimensions and weight Dimensions (HxWxD): 700x400x330 mm Empty weight: 30.0 Kg Ferroli boiler DIVATECH D LN LOW NOX Wall mounted boiler with instantaneous domestic hot water production with double exchanger , open chamber, natural draft Strengths - Compact geometry primary heat exchanger entirely in copper - Instantaneous production of domestic hot water with dedicated plate domestic heat exchanger - Standard by-pass - Open chamber and natural draft boiler, with low NOx emission atmospheric burner , in AISI 304 stainless steel - High efficiency low consumption circulator (ErP - Class A) with anti-blocking system by activation for a few seconds every 24 hours of inactivity - Can be combined with the modulating remote timer control - Casing painted white by anaphoresis with epoxy powders - Simple and complete control panel, display user interface, with setting keys - Compact dimensions and low weight Advantages of Divatech D LN - Modulating heat input both in heating and in DHW production, managed by an electronic microprocessor card - ECO/COMFORT system for rapid production of domestic hot water - Adjustable post-circulation after the heating phase - Predisposition for solar systems : prearranged for the production of domestic hot water combined with solar panel systems - Certified operation also with propane air by means of a specific transformation to be requested from the Authorized Assistance Centre - Also works on LPG with the use of a special conversion kit to be requested from the Authorized Assistance Centre. Free transformation during product verification and activation of the guarantee only if the specific code running on LPG is not available Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €570,00

  • Sale -15% immagine-1-ferroli-offerta-ventilconvettore-fan-coil-ferroli-top-fan-plus-mod-vm-b-50-commutatore-cm-f-omaggio

    Ferroli Fan Coil Fan Coil Ferroli Top Fan Plus Mod VM-B 50 + Free CM-F Switch

    Technical features Model : VM-B 50 Number of fans : 2 CM-F switch included Performance Power supply (V,Hz, Ø) : 220~240/50/1 Cooling power : 2390 ~ 3400W Heating power : 4930 ~ 7800W Dehumidification: 1150g/h Air flow : 350 ~ 615 m3/h Sound power : 36 ~ 51 db(A) Sound pressure : 27 ~ 42 db(A) Installation data Main battery connections: 3/4" Additional battery connections: 1/2 " Main battery water content: 1.88 litres Additional battery water content: 0.50 litres Dimensions and weight Dimensions (HxWxD): 554+100x1190x 220mm Weight : 27.0kg Ferroli TOP FAN PLUS fan coil Consisting of a fan, a heat exchange element and a filter, fan coil units are ideal machines for summer air conditioning and winter heating of the house and any room. Fed with chilled water from a cooler, they make the air in the room fresh, dry and clean in a very short time and with great energy efficiency; fed with hot water from a heat pump or boiler, they provide clean and economical heat during the winter season. Series with centrifugal fan, available in 9 sizes and three versions: VM-B with casing for vertical and horizontal installation and suction from below VM-F with casing for vertical and horizontal installation and front suction VN without casing for vertical and horizontal installation Characteristics Cover cabinet obtained by integrating parts in plastic material and parts in galvanized sheet metal, oven painted with epoxy powders Supporting structure in galvanized steel Finned pack heat exchange coil with aluminum fins and copper pipes, brass manifolds specially designed to guarantee low pressure drops Air filter easy to remove and clean, regenerable by washing or blowing Fan unit with three-speed motor and aluminum impellers Wide range of controls both to be installed on the machine and remote on the wall New version with infrared remote control Switch It has a selector for the Summer / Off / Winter function, while the second selects the Min / Med / Max fan speed. Available in two different versions: - for installation on CM-F cabinet - for CMR-F remote installation Two series of panels are available for this type of installation: ON THE MACHINE for installation of the fan coil on the floor (models VM-B, VM-F), REMOTE ON THE WALL for installation of the fan coil on the ceiling (models VM-B, VM- F) or false ceiling (model VN). Each of the series includes three types of control, switch, basic thermostat and advanced thermostat. Novelty Remote control Optional Infrared remote control, for all sizes and versions, with liquid crystal display complete with support bracket for wall mounting, which allows the following functions: Power on Power off Operating modes (Hot/Cool/AutoChange Over/Ventilation only - presence of valves required-) Fan speed (Max/Med/Min/Auto) Set point temperature Timer setting °C or °F temperature scale setting Visible receiver Located on the front panel of the unit, it is complete with Timer led (yellow), operating led (green) and emergency ON/OFF button and reception area. The system completes with the card inside the unit. The system is supplied already installed and tested in the company. Recessed wall receiver The receiver is supplied in the case of recessed units and is positioned visible on the false ceiling. It is complete with a yellow Timer led, a green operating led and an emergency ON/OFF and reception area button. It is supplied with a multipolar cable of a maximum length of 0.8 metres, for quick connection and with the electronic card to be installed on the unit. It can be removed from the machine; the testing of the system takes place in the company while the positioning of the receiver is the responsibility of the installer. Product Guarantee : All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €215,00€182,00

  • immagine-1-ferroli-scaldabagno-elettrico-ferroli-calypso-50-ho-orizzontale-50-litri

    Ferroli Electric water heater Ferroli Calypso 50 Ho Horizontal 50 Liters

    Technical features Model: Calypso 50 HO Horizontal Tank capacity: 48.5 litres Electric Power: 1200W Load profile : M ERP class : D Heating time (20+55°C) : 2h - 3 min Dimensions : 56.5 x 44 x 46cm Empty weight: 19 kg Warranty: 2 years CALYPSO MEDI LITRAGGI ELECTRIC WALL-MOUNTED WATER HEATERS For indoors The CALYPSO electric water heater is made of high quality steel, with a special powder enamel treatment inside the cylinder, created with advanced electrostatic application techniques and subsequent kiln firing at 850°C for perfect glass porcelain coating of the tank. To keep heat loss to a minimum, CALYPSO has been insulated internally with high density polyurethane foam without CFC content, externally with a polymer coating with high resistance to heat loss. All models are 100% tested to ensure perfect operation at the intended operating pressure. CALYPSO water heaters can boast three safety devices: a hydraulic valve which is activated in the event of overpressure in the internal tank and two automatic overtemperature protection systems. Characteristics: Models with capacities from 50 to 150 litres. Also available in mixed thermo (MT) version. Removable electric resistance in copper Probe thermostatic control. Magnesium anode to protect the tank. 5-bolt flange to ensure sturdiness and ease of periodic maintenance. Temperature level indicator. On/off light. Safety valve calibrated at 8 bar with drain cock and safety screw Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €141,00

  • Caldaia A Condensazione Ferroli Divacondens D Plus F24 Low Nox Gpl Completa Di Kit Scarico Fumi - CaldaieMurali

    Ferroli Ferroli Divacondens D Plus F24 Low Nox LPG Condensing Boiler Complete With Smoke Exhaust Kit

    LPG operation with the use of a special conversion kit to be requested from the Authorized Assistance Centre, we recommend contacting the local assistance center before purchasing Technical features Model : Divacondens D Plus F24 Power supply: LPG Energy efficiency Heating energy efficiency class: B Sanitary energy efficiency class: A ACS profile : XL Performance Heat output : 7.5 ~ 25.0 kW Thermal power 80°C ~ 60°C : 7.2 ~ 24.2 kW Thermal power 50°C ~ 30°C : 7.7 ~ 26.2 kW Useful thermal efficiency 80°C ~ 60°C : 96.0% ~ 96.9% Useful thermal efficiency 50°C ~ 30°C : 102.4~ 104.0% NOx emissions : 6 Maximum production of domestic hot water Δt 25°C : 13.9 l/min Maximum production of domestic hot water Δt 30°C : 11.6 l/min Heating working pressure: 0.8 ~ 3 bar Sanitary operating pressure: 9 bar Dimensions and weight Dimensions (LxHxP): 400x680x330 mm Empty weight: 35.0 kg 5 years without worries Extension of the manufacturer's standard warranty to 5 YEARS on Ferroli brand gas condensing boilers of less than 35 kW in the DIVACONDENS and BLUEHELIX series through the local authorized Ferroli technical assistance centre. Wall-mounted boiler Ferroli DIVACONDENS D PLUS Atmospheric wall-mounted condensing boilers, with instantaneous domestic hot water production The simplest solution for a condensing boiler DIVACONDENS D PLUS is the condensing heat generator for traditional heating systems. The tried and tested Ferroli technology in the field of traditional wall mounted boilers has been enriched by increasing the performance of the product in the simplest way, with the use of a robust recuperator which preheats the primary circuit using the residual heat of the exhaust fumes and a new cooled burner with low NOx emissions. DIVACONDENS D PLUS is offered in a single model for heating and instantaneous production of domestic hot water Product plus > Condensing boiler for heating high temperature systems and producing domestic hot water. It is not suitable for combination with direct delivery to systems with low temperature radiant panels > Compact geometry primary exchanger > Instant production of domestic hot water with dedicated plate exchanger > Post-recovery of the latent heat of condensation, in function of pre-heating of the primary circuit > Forced draught sealed chamber boiler, with water-cooled atmospheric burner with low NOx emissions > Standard automatic hydraulic by-pass > Minimum polluting emissions, class 6 according to EN 15502-1 > High-efficiency, low-consumption circulator with anti-blocking system by activation for a few seconds every 24 hours of inactivity > Can be combined with the modulating remote timer control > Simple and complete control panel, display user interface, with setting keys > Robust post-condenser fed by the closed circuit of the primary. The heat exchange with the fumes takes place inside large diameter water passages > Generator with simple and rational operation > ECO function in DHW for greater savings in the period of low use of hot water > Predisposition for solar systems : prearranged for the production of domestic hot water combined with solar panel systems > Place of installation : also for outdoors in a partially protected place down to -5°C as standard > Certified operation also with propane air (50% air - 50% G31) by means of a specific transformation to be requested from the Authorized Assistance Center > Also works on LPG with the use of a special conversion kit to be requested from the Authorized Assistance Centre Boiler control The DIVACONDENS D PLUS control unit consists of an easy-to-use interface with a backlit display. Using the buttons, it is possible to easily adjust the heating flow temperature, the domestic hot water setpoint, switch the generator on/off or activate the comfort function, monitoring the status of the boiler. The control panel is completed by a traditional pressure gauge which can check the system pressure at any time. Main components Heat recovery Post-condenser with recovery of latent heat from the combustion fumes and condensate discharge Steel frame Made with high precision automated processes. Incorporates an 8 liter expansion vessel Central heating primary exchanger protected by a non-toxic aluminum coating Low NOx burner Water-cooled low temperature micro flame type. Minimum NOx emissions High efficiency circulator , for heating and exchange with the DHW circuit Domestic hot water exchanger In stainless steel, with copper brazing ECS - Evolved Combustion System Innovative combustion control that guarantees optimal functioning under various thermal load conditions and types of chimney Optimize comfort and savings "ROMEO N" timer control The ROMEO N timer control allows control and setting of the boiler functions directly from the room in which it is installed. Comfort programming is possible on a weekly basis and also includes the 'holiday' function. ROMEO N is available with wired or wireless connection. With ROMEO N you can: Adjust the heating and DHW temperatures Know the operating status of the boiler View the indoor temperature in your home Program the weekly ambient comfort Activating/deactivating the heating function via the telephone (Optional) Smart CONNECT remote control Remote control supplied with the class A+ kit code for home comfort management also from a Smartphone Possibility of managing up to 8 zones using additional room units Connection to the home Wi-Fi network via the supplied RF/Wi-Fi receiver CONNECT APP available for boiler on/off and domestic heating/DHW comfort management remotely via Smartphone (iOS and Android) Maximization of room comfort with modulating regulation of the flow temperature through the Room Climatic Compensation functions differentiated for each zone and External Climatic Compensation via external temperature detectable directly from the internet or from an optional external probe It improves the average seasonal efficiency in space heating by +4%. Weekly time programming in 30-minute intervals via APP CONNECT Operating modes : Off, Holiday, Automatic, Manual Three modifiable temperature levels : Comfort, Economy, Antifreeze By reading the external temperature directly from the internet (or from the optional external probe) the system is able to vary the system temperature according to the external temperature measured on the basis of configurable climatic curves, thus guaranteeing the user maximum room comfort at the change in external climatic conditions. The modulating function of CONNECT allows modulation of the boiler power as the set room temperature value is reached. This improves the quality of comfort by eliminating heat peaks with consequent energy savings Solar circuit integration Sun Easy function DIVACONDENS D PLUS boasts electronics that simplify integration with thermal solar systems, both with natural and forced circulation. The microprocessor controls the temperature of the water coming from the solar circuit through the domestic hot water sensor and turns on the burner only if necessary. In case of insufficient irradiation and therefore a modest pre-heating of the domestic water, the boiler will contribute with the heat necessary to reach the required set point temperature. If the sun and the solar system fulfill their "duty" no integration by the boiler will be necessary, the hot water will be conveyed to the tap, without the need for additional devices, with the mixing of the thermostatic valves. To reach the desired temperature, SUN EASY allows considerable savings even during the coldest seasons, exploiting and integrating even the smallest solar contribution, otherwise lost. Safety and comfort Functions Antifreeze In the event that the temperature in the boiler drops to 5°C, the burner ignites automatically and the circulator is activated in order to protect the appliance from damage caused by freezing. This function is active with the boiler powered by the gas circuit and under electrical voltage Post-circulation This function makes it possible to recover all the heat supplied by thermal inertia of the exchanger and transfer it to the heating system, and consequently to the rooms to be heated. This is a timer function and is active after the burner goes out in heating mode. Sliding temperature operation With the installation of the “External probe” kit it is possible to operate the boiler in sliding temperature. This means that without using the system temperature adjustment keys, the boiler will self-regulate according to the variations in external temperatures. All this translates into energy savings while ensuring maximum comfort for the user Easy Control The electronic board of DIVACONDENS D PLUS adopts the Opentherm protocol. It allows the integration of other peripheral control units such as, for example, the ROMEO N and CONNECT remote timer controls. In fact, the Opentherm standard has been specially designed to share the logic and operating algorithms of the boiler with other additional control units. As a digital protocol, it allows total integration between the boiler and the satellite, with full control of the functions from the boiler and similarly from its satellite Product Guarantee : All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €580,00

Recently viewed products

Login

Forgot your password?

Don't have an account yet?
Create account