Wall Boilers
Biasi Biasi Basica Dgt R Nox 24s Condensing Boiler With Low Nox Methane Recovery Unit Complete With Smoke Kit - New
Biasi Basica DGT R NOx 24s condensing boiler with low NOx methane recovery unit complete with flue gas kit - NEW Heating/DHW nominal heat input kW 24.8 Heating/DHW minimum heat input kW 10.0 Heating/DHW maximum useful power 60°/80°C * kW 24.0 Heating/DHW minimum useful power 60°/80°C * kW 9.4 Heating/DHW maximum useful power 30°/50°C ** kW 25.3 Heating/DHW minimum useful power 30°/50°C ** kW 9.7 Quantity of condensate at Q.nom. 30°/50°C (in heating) ** l/h 4.0 Amount of condensate at Q.min. 30°/50°C (in heating) ** l/h 1.6 Condensate pH 4.0 Yield name 60°/80°C * % 96.6 Yield min. 60°/80°C * % 93.9 Yield name 30°/50°C ** % 102.2 Yield min. 30°/50°C ** % 97.0 Yield at 30 % load * % Yield at 30% load ** % 100.9 Energy Efficiency ★★★★ Thermal losses in the chimney with the burner in operation Pf (%) 2.7 Chimney heat losses with burner off ΔT 50°C Pfbs (%) 0.2 Thermal losses to the environment through the casing with burner in operation Pd (%) 1.0 NOx class n° 6 Weighted NOx *** mg/kWh 54 Minimum/maximum heating temperature **** °C 38-85 Minimum/maximum heating pressure 0.3-3 bar Head available for heating (at 1000 l/h) bar 0.247 Expansion vessel capacity (total/useful) l 8 Minimum/maximum sanitary temperature °C 35-60 Minimum/maximum DHW pressure 0.3-10 bar Maximum flow rate (ΔT=25K) / (ΔT=35K) l/min 13.6-9.7 Specific sanitary flow rate (ΔT=30 K) ***** l/min 11.5 Voltage/Power at nominal heat input V~/W 230~/102 Power at minimum thermal capacity W 22 Power at rest (stand-by) W 1 Degree of protection n° IPX4D Minimum/maximum smoke temperature # °C 71/76 Minimum/maximum flue mass flow rate # kg/s 0.0111/0.0135 Minimum/Maximum Air Mass Flow # kg/s 0.0109/0.0130 Length max coaxial flue gas outlet (Ø 60/100 mm / Ø 80/125 mm) m 3.0/4.0 Length max double flue gas outlet (Ø 80+80 mm) m 25.0 Height x Width x Depth mm 758x400x325 Weight kg 42.0 Boiler water content 1.5 l Fuel Methane (G20) - Propane (G31) CNG code 10312.0218.0 BASIC DGT R Condensing boiler with recuperator Basica DGT R NOx completes the BIASI range of condensing boilers with recuperator : perfect for radiator systems and suitable for radiant systems with mixing groups. Basica is the compact condensing boiler that ensures high efficiency, low consumption and respect for the environment. Available for heating and domestic hot water production, in the 24 kW power . Basica DGT R NOx is in class B. Main features Water cooled burner Copper lamellar primary heat exchanger with large exchange surface and double circulation Heat recovery unit with stainless steel plates to exploit the heat of the fumes and transfer it to the water Modulation 1:3 CNG and also LPG Sanitary plate heat exchanger in stainless steel 8 liter expansion vessel High efficiency pump with low energy consumption Integration with BIASI solar systems, using a solar kit Analog pressure reading Arrangement for remote control and external probe Control panel functionality Summer/winter/off selector Heating temperature regulator DHW temperature regulator Analog reading of the pressure (read on the pressure gauge under the boiler) DHW and heating temperature visualization from the display Display of fault diagnostics, block status and fault history The display operates according to the modes: Remote commands The DGT R NOx Basic Boiler has the choice of 2 class V remote controls available, in the Base and Top versions with weekly chronothermostat functions with up to 4 programmable periods with independent temperatures, in addition to the remote control of all the information on the boiler display Product Guarantee: All products for sale on our site are new and packed. The guarantee on this item is 24 months from the date of purchase.
€725,00
Biasi Gas Boiler Biasi Inovia Cond E 25s Condensing Complete With Methane Fume Exhaust Kit - New Erp
Overview BIASI INOVIA COND E 25S METHANE CONDENSING BOILER - NEW ErP, SEALED CHAMBER COMPLETE WITH FUME EXHAUST KIT: Wall mounted condensing boilers. The premixed range is simple on the outside and technological on the inside. The sites displaying the Biasi web sales authorized brand have been authorized by BSG Caldaie a Gas SpA for the sale of Biasi products. These companies therefore release the conventional guarantee. Technical specifications o Model: Inovia Cond E 25S Energy label specifications according to the European ErP directive o Class A heating energy efficiency o Sanitary energy efficiency Class A o Withdrawal profile: XL Characteristics of heating/DHW operation: o DHW useful thermal power: 24.4 kW o Useful thermal power for heating: 19.5 kW o Nominal kW heat input(*): 25 kW o Efficiency at 100% load: 106.2% o Sanitary flow rate t =25°K: 15.9 l/min o High yields (in compliance with yield directive 92/42 CEE and Legislative Decree 311/06) o Sanitary comfort (EN 13203) o Total premix burner, built in stainless steel (Class NOx 5) o Sanitary plate heat exchanger in stainless steel o High efficiency pump with low energy consumption o IPX5D degree of protection o Dimensions hxwxd: mm 700 x 400 x 290; 32kg o METHANE power supply Main features Inovia Cond E Premixed condensing boilers Inovia Cond E represents the new premixed BIASI condensing boiler. Inovia Cond E is equipped with innovative aesthetics and a new interface that is immediate and easy to use, it is equipped with new functions that make it an integral part of a system and which facilitate its installation and maintenance. Inovia Cond E offers all the advantages of condensing technology: great performance, high efficiency, energy saving and respect for the environment thanks to reduced polluting emissions such as NOx and CO. Installed in low temperature systems, they allow savings of up to 30%. Characteristics: o • High yields (in compliance with yield directive 92/42 EEC and Legislative Decree 311/06) or • Sanitary comfort (EN 13203) o • Primary condensing exchanger in stainless steel with plastic coating to offer maximum resistance to corrosion o • Total premix burner, built in stainless steel (Class NOx 5) or • Sanitary plate heat exchanger in stainless steel or • High efficiency pump with low energy consumption or • IPX5D degree of protection or • Can be installed in a partially protected place or • Integration with BIASI solar systems, using a solar kit o • Innovative digital control panel with graphic interface and keys or • Digital pressure reading by pressure transducer or • Arrangement for remote control and external probe or • Possibility of remotely managing a zone valve in the case of multi-zone systems. Control panel: o Summer/winter/off selector o Heating temperature regulator o DHW temperature regulator o Digital pressure reading o Domestic hot water and heating temperature visualization from the display o Visualization of fault diagnostics, block status and fault history o Recommended filling view and filling guide o View months left until annual maintenance is due o External temperature display (with external probe connected) and signaling of external probe connected and K value set o Display of flame modulation o Visualization of the BIASI SOLCONTROL solar control unit connected to Inovia Cond E, active solar pump and solar integration o DHW comfort function selectable by means of a dedicated and programmable key o Direct access to the INFO menu dedicated to the user. Fiscal detraction As a condensing boiler, Inovia Cond E allows you to take advantage of the tax deduction according to current legislation. d Thermoregulation By connecting the external probe (optional) directly to the boiler, climatic regulation can be used. Inovia Cond E will adapt the system water temperature to the external climatic conditions, ensuring that the desired room temperature is reached without waste and optimizing consumption. The boiler is equipped with a complete set of curves which can be accessed by entering programming. The curve is simply chosen from the control panel. Solar management Inovia Cond E integrates solar management directly into the product. Thanks to the integrated solar management it is possible to connect the SOLCONTROL control unit and view the status of the pump and the relative solar integration. Zone management Inovia Cond E features the zone management card as standard which allows you to manage a zone valve using the BIASI remote control. In the case of a system with several high temperature zones, one zone can be managed by remote control and the other zones can be managed by chronothermostats. This allows you to select two thermoregulation curves, one in the boiler and the other in the remote control. All the zones controlled by chronothermostats will be managed by the thermoregulation curve set in the boiler, the zone controlled by the remote control will be managed by the thermoregulation curve set therein. In the case of multi-zone systems at high and low temperatures, it is recommended to use the BIASI MULTIzone system manager. All ready for Energy Labeling What is it about? From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy-intensive sectors: construction For placing on the European market, the Eco-Design Directive (ErP known as « Energy Related Products ») imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: or generators with a capacity of less than 400 kW or water heaters with a capacity of less than 400 kW, or kettles with a capacity of less than 2000 litres As in the household appliances sector, the energy labeling of products with a capacity of less than 70 kW will give consumers simple, recognizable information which allows them to compare the performance and energy consumption of the product they wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. Is it about me too? YES, it affects everyone: professionals and end users The information indicated on the energy label will allow professionals to recommend the right product and individuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015, the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. Supplier responsibility The company that supplies the product on the market is required to equip its devices or systems with the following documentation: o product energy label; o product data sheet; o system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices; o technical data sheet of the system with the parts relating to the product or the system already completed. o Dealer liability First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device and/or system to the public. Therefore even professionals such as plumbers, installers or planners can fall into this category. Everyone is required to ensure that: o all appliances and/or systems are equipped with the respective labels and make sure that they are clearly visible; o all devices and/or systems are always accompanied by the mandatory technical data sheets; o any type of advertising, promotional or technical material in which energy data or price indications are shown, contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and hot water production will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP): The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL Depending on the type of device, there are different labels. Those with efficiency classes A, A+ and A++ certify the products with the highest performance. Furthermore, two different classifications are envisaged for domestic heating and for the hot water production service, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the final customer can make his choice in the most informed way possible. SYSTEM LABEL In addition to the product label, the system label is also provided if a series of matched appliances is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label in order to inform the end user in the best possible way. Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.050,00
Biasi Gas Boiler Biasi Inovia Cond Plus 25s Condensing Complete With LPG Fume Exhaust Kit - New Erp
Overview BIASI INOVIA COND PLUS 25S CONDENSING LPG LPG BOILER - NEW ErP, SEALED CHAMBER COMPLETE WITH FUME EXHAUST KIT: Inovia Cond Plus is the new BIASI range of wall-mounted condensing boilers: excellent performance thanks to the new heat exchanger and ease of use thanks to the panel digital control with large displays. Technical specifications Model: Inovia Cond Plus 25S Energy label specifications according to the European ErPÿ directive Class A heating energy efficiency Sanitary energy efficiency Class A Withdrawal profiles: XL Characteristics of heating/sanitary exercises: Heating/DHW maximum useful power: 19.3/25.1ÿkWÿ Heating/DHW nominal heat input: 20/26 kW Yield name 60ø/80øC:ÿ96.7% Yield at 30% load: 107.4% High yields (in compliance with yield directive 92/42 CEE and Legislative Decree 311/06) Sanitary comfort( EN 13203)ÿ 8 liter expansion tankÿ Degrees of protection IPX5Dÿ Maximum flow rate (T=25 K) / (T=35 K): 14.4/10.3 l/minÿ Specific sanitary flow rate (T=30 K): 12.0ÿl/minÿ Dimensions hxwxd: mmÿ700 x 400 x 290; 32kg NOx class : 6 LPG or LPG fuel supply Main features Inovia Cond Plus Wall mounted condensing boilersÿ Inovia Cond Plus is the new BIASI range of wall-mounted condensing boilers: excellent performance thanks to the new heat exchanger and ease of use thanks to the digital control panel with large displays. Available in the versions for heating and domestic hot water production and for heating only, Inovia Cond Plus presents a complete range of powers, 25 and 35 kW combi models and 25 and 35 SV models, in the same extremely compact dimensions (700 x 400 x 290mm). Inovia Cond Plusÿhas its strength in the innovative heat exchangerÿdesigned to provide high yields that last in the digital control panel, designed to communicate with the user in an easy and comfortable way. Like the entire BIASI condensing range, Inovia Cond Plus allows you to obtain maximum savings from climatic thermoregulation, based on the system in which the boiler is installed. High yields (complies with 92/42 EEC yield directive and Legislative Decree 311/06) Sanitary comfort (EN 13203)ÿ Primary and condensing heat exchanger in stainless steel withÿaluminium coatings to offer maximum resistance to corrosionÿ Total premix burner, built in stainless steel (Class NOx5) Sanitary plate heat exchanger in INOXÿ steel High efficiency pump with low energy consumption 8 liter expansion tankÿ Maximum power adjustable according to the systemÿ Degrees of protection IPX5Dÿ Can be installed in a partially protected placeÿ Integration with BIASI solar systems, using a solar kitÿ Innovative digital control panelÿ Digital pressure readoutÿ Arrangement for external probe remote controlÿ Possibility of managing a zone valve by remote control in multi-zone systems. High circulation primary heat exchanger Biasi produces the new Steelcoil compound exchanger with a stainless steel spiral enclosed in an aluminum shell. Thanks to the large exchange surface of the coil, greater thermal efficiency is guaranteed with a lower loss of charge and easier cleaning. The ease of cleaning and the sturdiness of this exchanger are one of the main strengths of the product which can be used on new systems but also on old systems in case of renovations. Steelcoil integrates the round flow function in which the water produces a centrifugal cleaning effect on the internal walls of the monspira. Does the absence of parallel circuits guarantee an easy cleaning operation? of the exchanger and the elimination of any air present in the system circuit. Thermoregulationÿ By connecting the external probe and the remote control (optional) directly to the boiler, climatic regulation can be used. Inovia Cond Plus will adapt the water temperature of the system to the external climatic conditions, guaranteeing the achievement of the desired room temperature without waste and optimizing consumption. By using climatic regulation, the regulation efficiency is also increased, giving greater value to your home. All ready for Energy Labeling What is it about From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy intensive sectors: construction For placing on the European market, the directive on ÿeco-designÿ(ErP notcome®ÿEnergy Related Productsÿ¯) imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres or As in the household appliances sector, the energy labelingÿof products, with a capacity of less than 70 kW, will give consumers simple, recognizable information which allows them to make comparisonsÿon the performance and energy consumption of the product they wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. It's about me tooÿ YES, it affects everyone: professionals and end users The information indicated on the energy labelÿwill allow professionals to recommend the right productÿÿindividuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015, the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. Supplier's responsibility The company that supplies the product on the market is required to equip its system devices with the following documentation: product energy label;ÿ product data sheet;ÿ system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices;ÿ technical data sheet of the system with the parts relating to the products and the system already completed. Responsibilities of Resellersÿ First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device/system to the public. Therefore, even professionals such as plumbers, installers, designers can fall into this category. All bound to ensure that: all appliances and/systems having their respective labels and making sure they are clearly visible;ÿ all appliances and/systems must always be accompanied by the obligatory technical data sheets;ÿ every type of advertising material, technical promotional material which shows energy data and price indications, contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and the production of hot water will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP): The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL There are different labels depending on the type of appliance. Those with efficiency classes A, A+ and A++ certify products with the highest performance. Furthermore, two different classifications are foreseen for domestic heating and for hot water production services, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the end customer can make his choice in the most aware way possible. SYSTEM LABEL In addition to the product label, the system label is also providedÿin cases where a series of appliances combined with each other is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label so as to inform the end user in the best possible way. Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.160,00
Biasi Gas Boiler Biasi Parva Recover E 28s Condensing Complete With LPG Fume Kit -New Erp
Overview BIASI PARVA RECUPERA E 28S LPG CONDENSING BOILER - NEW ErP 2015, SEALED CHAMBER COMPLETE WITH FUME EXHAUST KIT: PARVA Recupera E the ErP condensing boiler with heat recovery unit Technical specifications Model:ÿPARVA Recover E 28S Product number:ÿ10313.2027.3 Energy label specifications according to the European ErPÿ directive Class B heating energy efficiency Sanitary energy efficiency Class A Withdrawal profiles: XL Characteristics of heating/sanitary exercises: Thermal input:ÿ29ÿkW Rated useful power: 28.4 kW Nominal load efficiency:ÿ98% Efficiency minimum load:ÿ95.8% Energy efficiency stars: (dir 92/42/CEE) **** Min/max heating temperature: 38/85ÿøC Capacity of the expansion vessel: 6 lt Sanitary flow rate t =25øK l/min: 16.3 l/min Degrees of protection for the electrical system:ÿIPX4D Extremely compact dimensions hxwxd: mmÿ803x400x350ÿ; 49kg LPG fuel supply Features list ErP wall-mounted boilers with recuperator Redeveloping an old thermal systemÿ Biasi has designed the ÿPARVA Recupera NOx EÿandÿPARVA Recupera Eÿboilers to replace traditional boilers in old systems. The PARVA Recupera boilers by Biasi are equipped with a corrosion-resistant aluminum alloy fume recovery unit which makes these boilers particularly solid. The recovery unit is made of aluminium, has a finned coil which determines a large exchange surface and is equipped with a device to ensure that the boiler discharges the condensate correctly. The recuperator is treated with a Teflon coating process to ensure maximum durability over time. Thanks to the large exchange surface, the recuperator allows the recovery of thermal energy which would otherwise be dispersed outside through the hot fumes produced by combustion. PARVA Recover E PARVA Recupera E is the condensing boiler designed for traditional systems and easily adaptable to new floor-based systems using MULTIZONE, a hot water distribution system for heating. PARVA It recovers the traditional boiler in the regulations but it has clearly higher efficiency than the traditional boilers at the same operating temperature. As a condensing boiler, PARVA Recupera allows you to take advantage of the tax deduction according to current legislation. Characteristics: High yields (in compliance with yield directive 92/42 EEC and Legislative Decree 311/06ÿ Primary laminated copper heat exchanger with large double circulation exchange surfaceÿ Aluminum heat recovery unit to exploit the heat of the fumes and transfer it to the waterÿ Sanitary plate heat exchanger in INOXÿ steel High efficiency pump with low energy consumptionÿ retractable control panel, with ergonomic knobs and backlit displayÿ Electronic board for:ÿ - Re-ignition frequency adjustmentÿ - Adjustable primary circuit thermal inertia disposalsÿ - Selection of circulator modeÿ - Circulator anti-seizeÿ - Antifreeze safetyÿ - Chimney sweep functionÿ Integrated automatic by-passÿ Immunity to radio interferenceÿ Sanitary flowstat magneticÿ Absolute heating pressure switchÿ Degrees of protection IPX4Dÿ Possibility of integrating PARVA Recupera E with Biasi solar systems using the optional solar kit. Fiscal detraction As a condensing boiler, PARVA Recupera E allows you to take advantage of the tax deduction according to current legislation.ÿÿ Heat recoveryÿ The heat recovery recovers the heat from the fumes before they are expelled and preheats the water directed to the primary exchanger. The recuperator made of aluminum has a finned coil which determines a large exchange surface and has a device to ensure that the boiler discharges the condensate correctly.ÿÿ Thermoregulation By connecting the external probe (optional) directly to the boiler, you can access the climatic adjustment function. The boiler is equipped with a complete set of curves which can be accessed by entering programming. By simply turning a knob you choose the curve, PARVA recovers and will automatically adapt its operation to the external climatic conditions.ÿÿ High circulation primary heat exchangerÿ It is the element that distinguishes the whole PARVA E Biasi range. It favors the flow of water into the heating system and, thanks to its reduced hydraulic resistance, adapts the boiler to the system, facilitating the transmission of heat to the radiators.ÿ Save simplicity of use Parva Recupera retains the simplicity of management, programming and regulation of the traditional boiler and imports the savings of the condensing boiler resulting from the recovery of heat from the fumes. The heat recovery unit preheats the system water with the heat released by the fumes, heat which in traditional boilers is dispersed into the environment. This recovery of energy from the fumes, at operating temperatures typical of radiator systems, leads Parva Recupera to have higher yields than traditional boilers. Low complexity, high comfort Parva Recupera boilers, despite the high technical content, are still very easy to use. Theÿcontrol panelÿhas two knobs dedicated to regulating the temperature of the domestic hot water and the heating water, the key to reset the boiler after the lockout status, the new display to view the boiler operating status and facilitate understanding by the User and the installer's settings . Fault diagnostics allow immediate verification of correct operation. The manometer allows you to check the system pressure while the temperature is shown on the display. Everything is hidden under a door that defines the sober and linear aesthetics of Parva Recupera. Included in delivery Boiler support bracket and paper templateÿ Condensate collection trapÿ Quick instruction to the user.ÿ All ready for Energy Labeling What is it about From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy intensive sectors: construction For placing on the European market, the directive on ÿeco-designÿ(ErP notcome®ÿEnergy Related Productsÿ¯) imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres As in the household appliances sector, the energy labelingÿof products, with a capacity of less than 70 kW, will give consumers simple, recognizable information which allows them to make comparisonsÿon the performance and energy consumption of the product they wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. It's about me too YES, it affects everyone: professionals and end users The information indicated on the energy labelÿwill allow professionals to recommend the right productÿÿindividuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015, the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. Supplier's liability The company that supplies the product on the market is required to equip its system devices with the following documentation: product energy label;ÿ product data sheet;ÿ system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices;ÿ technical data sheet of the system with the parts relating to the products and the system already completed. Responsibilities of Resellersÿ First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device/system to the public. Therefore, even professionals such as plumbers, installers, designers can fall into this category. All bound to ensure that: all appliances and/systems having their respective labels and making sure they are clearly visible;ÿ all appliances and/systems must always be accompanied by the obligatory technical data sheets;ÿ every type of advertising material, technical promotional material which shows energy data and price indications, contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and the production of hot water will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP): The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL There are different labels depending on the type of appliance. Those with efficiency classes A, A+ and A++ certify products with the highest performance. Furthermore, two different classifications are foreseen for domestic heating and for hot water production services, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the end customer can make his choice in the most aware way possible. SYSTEM LABEL In addition to the product label, the system label is also providedÿin cases where a series of appliances combined with each other is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label so as to inform the end user in the best possible way. Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.019,00
Biasi Biasi Basica Cond 25s Condensing Boiler Complete With Low Nox Erp Methane Fume Exhaust Kit - New
Biasi BASICA COND 25s condensing boiler complete with Methane or LPG ErP Fume Exhaust Kit - NEW Model BASICA COND 25S DHW nominal heat input kW (kcal/h) 26.0 (22356) Nominal heat input * heating kW (kcal/h) 21.0 Maximum useful power in heating 60/80° kW (kcal/h) 20.5 (17627) Useful power in domestic hot water 60/80° kW (kcal/h) ) 25.4 (21840) Efficiency at 100% load (50/30 °C) % 106.8 Sanitary flow rate ∆t =25°K l/min 14.7 NOx class 6 CNG code 10312.0214.0 Dimensions HxWxD mm 700x400x325 BASIC COND Basica Cond Basica Cond completes the BIASI range with premixed condensing: perfect for radiator systems and suitable for radiant systems with mixing groups. Basica is the compact condensing boiler that ensures high efficiency, low consumption and respect for the environment. Available for heating and domestic hot water production, in power ratings of 25 and 30 kW. Main features Primary condensing exchanger in stainless steel with steel lining to offer maximum resistance to corrosion - Total premix burner, stainless steel (Class NOx 6) - Modulation 1:5 CNG and also LPG - Sanitary plate heat exchanger in stainless steel - 8 liter expansion tank - High efficiency pump with low energy consumption - Can be installed in a partially protected place - Integration with BIASI solar systems, using a solar kit - Analog pressure reading - Arrangement for remote control and external probe High circulation single coil primary heat exchanger Biasi introduces on the market the new stainless steel heat exchanger for condensing boilers: Round. Round is a compact monothermal heat exchanger based on a stainless steel coil with an oval section. The heat exchanger consists of a combustion chamber, condensing area and an insulated metal disc protected with silicone ceramic fiber which separates the two areas. By using a single strip of stainless steel to produce the coil, including inlet/outlet fittings, the following benefits are achieved: - The accumulation of dirt and debris is avoided - The water flow rate is constant, guaranteeing a higher average life of the product - Reduction of load losses with optimized circuit. The ease of cleaning and the sturdiness of this exchanger are one of the main strengths of the product since it can be used on new systems but also on old systems in the event of renovations. Round integrates the round flow function in which the water produces a centrifugal cleaning effect on the internal walls of the single coil. The absence of circuits in parallel guarantees an easy "washing" operation of the exchanger and the elimination of any air present in the system circuit. Included in delivery Boiler support bracket and paper template Boiler power cable Condensate collection siphon Quick instruction to the user. Control panel Summer/winter/off selector Heating temperature regulator DHW temperature regulator Analog pressure reading DHW and heating temperature visualization from the display Display of fault diagnostics, block status and fault history The display operates in the following modes: INFO – information available on the operating status and error history FREE programming – programmable parameters for generator/system adjustment and User SET INSTALLER programming - generator parameters ASSISTANCE programming - Authorized Assistance Center parameters commands The Basica Cond Range has the choice of 2 class V remote controls (they allow deduction at 65), in the Base and Top version with weekly chronothermostat functions with up to 4 programmable periods with independent temperatures, in addition to the remote control of all the information of the boiler display. Product Guarantee: All products for sale on our site are new and packed. The guarantee on this item is 24 months from the date of purchase.
€755,00
Biasi Biasi Gas Boiler Recovers Dgt 28s LPG Condensing Complete With LPG Fume Kit -New Erp
Overview BIASI RECOVERY BOILER DGT 28S CONDENSING LPG LPG - NEW ErPÿ Technical specifications Model: Retrieve DGT 28S Energy label specifications according to the European ErPÿ directive Class B heating energy efficiency Sanitary energy efficiency Class A Withdrawal profiles: XL Characteristics of heating/sanitary exercises: Heating/sanitary nominal heat inputkW 29.0 Maximum useful heating/sanitary powerkW 28.3 Energy efficiencynø NOx class no. 2 Minimum / maximum heating temperature**øC 40 / 85 Capacity of expansion vessel (total / useful) l 8.0 / 4.0 Maximum flow rate (T=25 K) / (T=35 K) l/minÿ16.3 / 11.6 Degrees of protection nø IPX4D Height x Width x Depth mm 803x400x350 LPG or LPG fuel supply Main features RECOVER DGTÿ ÿWall mounted condensing boilersÿ Retrieve DGTÿ theÿcondensing boilerÿdesigned for traditional systems and easily adaptable to new floor-based systems using Multizone, hot water distribution devices for heating. Recupera DGT retains the simplicity of management, programming and regulation of the traditional boiler and imports the savings of the condensing boiler resulting from the recovery of heat from the fumes. The heat recovery unit preheats the system water with the heat released by the fumes, heat which in traditional boilers is dispersed into the environment. This recovery of energy from the fumes, at typical operating temperatures of radiator systems, leads Recupera DGT to have higher yields than traditional boilers. Characteristics: High efficiency ( ( compliant with 92/42 EEC directive and Legislative Decree 311/06,¶½ Primary laminated copper heat exchanger with large exchange surface, double circulation Aluminum heat recovery unit to exploit the heat of the fumes and transfer it to the water Sanitary plate heat exchanger in stainless steel High efficiency pump with low energy consumption digital control panel with backlit display Electronic board for:ÿ Restart frequency adjustmentÿ Adjustable primary circuit thermal inertia disposalsÿ Circulator mode selectionÿ Circulator anti-seizeÿ Frost safetyÿ Chimney sweep function Integrated automatic by-pass Immunity to radio interference Magnetic sanitary flow Absolute heating pressure switch Degrees of protection IPX4D Heat recovery The heat recovery recovers the heat from the fumes before they are expelled and preheats the water directed to the primary exchanger. The recuperator made of aluminum has a finned coil which determines a large exchange surface and has a device to ensure that the boiler discharges the condensate correctly. Four-controllers Summer/winter/off selector Heating temperature regulator DHW temperature regulator Digital and analog pressure reading DHW and heating temperature visualization from the display Fault diagnostics display, fault history block status View recommended fill Display annual periodic maintenance expiry All ready for Energy Labeling What is it about From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy intensive sectors: construction For placing on the European market, the directive on ÿeco-designÿ(ErP notcome®ÿEnergy Related Productsÿ¯) imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres or As in the household appliances sector, the energy labelingÿof products, with a capacity of less than 70 kW, will give consumers simple, recognizable information which allows them to make comparisonsÿon the performance and energy consumption of the product they wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. It's about me tooÿ YES, it affects everyone: professionals and end users The information indicated on the energy labelÿwill allow professionals to recommend the right productÿÿindividuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015, the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. Supplier's responsibility The company that supplies the product on the market is required to equip its system devices with the following documentation: product energy label;ÿ product data sheet;ÿ system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices;ÿ technical data sheet of the system with the parts relating to the products and the system already completed. Responsibilities of Resellersÿ First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device/system to the public. Therefore, even professionals such as plumbers, installers, designers can fall into this category. All bound to ensure that: all appliances and/systems having their respective labels and making sure they are clearly visible;ÿ all appliances and/systems must always be accompanied by the obligatory technical data sheets;ÿ every type of advertising material, technical promotional material which shows energy data and price indications, contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and the production of hot water will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP): The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL There are different labels depending on the type of appliance. Those with efficiency classes A, A+ and A++ certify products with the highest performance. Furthermore, two different classifications are foreseen for domestic heating and for hot water production services, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the end customer can make his choice in the most aware way possible. SYSTEM LABEL In addition to the product label, the system label is also providedÿin cases where a series of appliances combined with each other is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label so as to inform the end user in the best possible way. Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€881,00
Biasi Biasi Outdoor Condensing Boiler Artica Plus 25 S Low Nox Complete With Methane Fume Exhaust Kit - New
Biasi c low NOx outdoor condensing boiler complete with flue gas exhaust kit - New NB: PRODUCT AVAILABLE IN 6-8 WEEKS Heating / DHW nominal heat input kW 21.0 / 26.0 Yield name 60°/80°C * % 96.6 NOx class n° 6 Minimum / maximum heating pressure bar 3.0 / 0.3 Expansion tank capacity (total / useful) l 7.0 / 3.5 Maximum flow rate (ΔT=25 K) / (ΔT=35 K) l/min 14.4 / 10.3 Voltage / Power at nominal heat input V~/ W 230/99 Degree of protection n° IPX5D Height x Width x Depth mm 946x509x287; 30.7 kW Performance Stars **** ARTICA PLUS Artica Plus is the new BIASI range of wall-mounted condensing boilers for outdoor use : excellent performance thanks to the new heat exchanger and ease of use thanks to the digital control panel with display. In the version for heating and domestic hot water production Artica Plus is available in two powers, 20 and 30 kW, in the same extremely compact dimensions (946 x 509 x 287 mm). Artica Plus has its strong point in the innovative heat exchanger designed to provide high yields that last over time. Digital control panel, designed to communicate with the user easily and conveniently thanks to the remote control plus supplied as standard. Like the entire BIASI condensing range, Artica Plus allows you to obtain maximum savings from climatic thermoregulation, based on the system in which the boiler is installed. Main features High yields (★★★★ compliant with yield directive 92/42 EEC and Legislative Decree 311/06) Sanitary comfort (★★★ EN 13203) Primary condensing exchanger in stainless steel with steel lining to offer maximum resistance to corrosion Total premix burner, built in stainless steel (Class NOx 6) Modulation 1:5 CNG and also LPG Sanitary plate heat exchanger in stainless steel 7 l expansion tank for mod. 25S and 10 l for mod. 35S Maximum power adjustable according to the system High efficiency pump with low energy consumption Degree of protection IPX5D Can be installed in a partially protected place Closing the covers by means of magnets makes system loading operations and access to the gas cock immediate Digital control panel with backlit display Analog reading of the pressure on the machine, digital on the remote Automatic filling via remote Remote control plus as standard Standard external probe. High circulation single coil primary heat exchanger Biasi introduces on the market the new stainless steel heat exchanger for condensing boilers: Round. Round is a compact monothermal heat exchanger based on a stainless steel coil with an oval section. The heat exchanger consists of a combustion chamber, condensing area and an insulated metal disc protected with silicone ceramic fiber which separates the two areas. By using a single strip of stainless steel to produce the coil, including inlet/outlet fittings, the following benefits are achieved: Accumulation of dirt and debris is avoided The water flow is uniformly distributed and guarantees a homogeneous heat exchange The water flow is constant for a longer life of the product Reduction of pressure drops with optimized circuit. The ease of cleaning and the robustness of this exchanger are one of the main strengths of the product since it can be used on new systems but also on old systems in the event of renovations. Round integrates the round flow function in which the water produces a centrifugal cleaning effect on the internal walls of the single coil. The absence of circuits in parallel guarantees an easy "washing" operation of the exchanger and the elimination of any air present in the system circuit. Control panel Summer/winter/off selector Heating temperature regulator DHW temperature regulator Analog pressure reading DHW and heating temperature visualization from the display Display of fault diagnostics, block status and fault history Recommended fill display and fill guide View annual maintenance expiry The display operates according to the modes: 1. INFO. Info mode displays the following information: - External temperature (in case of external probe connected) - K value (in case of external probe connected) - Sanitary / heating temperatures chosen by the user - Smoke temperatures 2. PROGRAMMING. The programming mode allows you to change the boiler parameters. - In chimney sweep mode it is possible to test the boiler and adjust the gas valve. Thermoregulation By connecting the external probe (standard) and the remote control plus (standard) directly to the boiler, climatic regulation can be used. Artica Plus will adapt the system water temperature to the external climatic conditions, ensuring that the desired room temperature is reached without waste and optimizing consumption. By using the climatic regulation, the regulation efficiency is also raised, giving greater value to your home. Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.274,00
Biasi Biasi Basica Cond 25s Condensing Boiler Complete With LPG Low Nox Erp Fume Exhaust Kit - New
Biasi BASICA COND 25s condensing boiler complete with LPG Low NOx ErP Fume Exhaust Kit - NEW Model BASICA COND 25S DHW nominal heat input kW (kcal/h) 26.0 (22356) Nominal heat input * heating kW (kcal/h) 21.0 Maximum useful power in heating 60/80° kW (kcal/h) 20.5 (17627) Useful power in domestic hot water 60/80° kW (kcal/h) ) 25.4 (21840) Efficiency at 100% load (50/30 °C) % 106.8 Sanitary flow rate ∆t =25°K l/min 14.7 NOx class 6 GPL code10302.2043.0 Dimensions HxWxD mm 700x400x325 BASIC COND Basica Cond Basica Cond completes the BIASI range with premixed condensing: perfect for radiator systems and suitable for radiant systems with mixing groups. Basica is the compact condensing boiler that ensures high efficiency, low consumption and respect for the environment. Available for heating and domestic hot water production, in power ratings of 25 and 30 kW. Main features Primary condensing exchanger in stainless steel with steel lining to offer maximum resistance to corrosion - Total premix burner, stainless steel (Class NOx 6) - Modulation 1:5 CNG and also LPG - Sanitary plate heat exchanger in stainless steel - 8 liter expansion tank - High efficiency pump with low energy consumption - Can be installed in a partially protected place - Integration with BIASI solar systems, using a solar kit - Analog pressure reading - Arrangement for remote control and external probe High circulation single coil primary heat exchanger Biasi introduces on the market the new stainless steel heat exchanger for condensing boilers: Round. Round is a compact monothermal heat exchanger based on a stainless steel coil with an oval section. The heat exchanger consists of a combustion chamber, condensing area and an insulated metal disc protected with silicone ceramic fiber which separates the two areas. By using a single strip of stainless steel to produce the coil, including inlet/outlet fittings, the following benefits are achieved: - The accumulation of dirt and debris is avoided - The water flow rate is constant, guaranteeing a higher average life of the product - Reduction of load losses with optimized circuit. The ease of cleaning and the sturdiness of this exchanger are one of the main strengths of the product since it can be used on new systems but also on old systems in the event of renovations. Round integrates the round flow function in which the water produces a centrifugal cleaning effect on the internal walls of the single coil. The absence of circuits in parallel guarantees an easy "washing" operation of the exchanger and the elimination of any air present in the system circuit. Included in delivery Boiler support bracket and paper template Boiler power cable Condensate collection siphon Quick instruction to the user. Control panel Summer/winter/off selector Heating temperature regulator DHW temperature regulator Analog pressure reading DHW and heating temperature visualization from the display Display of fault diagnostics, block status and fault history The display operates in the following modes : INFO – information available on the operating status and error history FREE programming – programmable parameters for generator/system adjustment and User SET INSTALLER programming - generator parameters ASSISTANCE programming - Authorized Assistance Center parameters commands The Basica Cond Range has the choice of 2 class V remote controls (they allow deduction at 65), in the Base and Top version with weekly chronothermostat functions with up to 4 programmable periods with independent temperatures, in addition to the remote control of all the information of the boiler display. Product Guarantee: All products for sale on our site are new and packed. The guarantee on this item is 24 months from the date of purchase.
€755,00
Biasi Biasi Gas Boiler Recovers Dgt 28s Methane Condensing Complete With Methane Fume Kit -New Erp
Overview BIASI RECOVERY BOILER DGT 28S CONDENSING METHANE LPG - NEW ErPÿ Technical specifications Model: Retrieve DGT 28S Energy label specifications according to the European ErPÿ directive Class B heating energy efficiency Sanitary energy efficiency Class A Withdrawal profiles: XL Characteristics of heating/sanitary exercises: Heating/sanitary nominal heat inputkW 29.0 Maximum useful heating/sanitary powerkW 28.3 Energy efficiencynø NOx class no. 2 Minimum / maximum heating temperature**øC 40 / 85 Capacity of expansion vessel (total / useful) l 8.0 / 4.0 Maximum flow rate (T=25 K) / (T=35 K) l/minÿ16.3 / 11.6 Degrees of protection nø IPX4D Height x Width x Depth mm 803x400x350 ÿMETHANEÿorÿLPG power supply Main features RECOVER DGTÿ ÿWall mounted condensing boilersÿ Retrieve DGTÿ theÿcondensing boilerÿdesigned for traditional systems and easily adaptable to new floor-based systems using Multizone, hot water distribution devices for heating. Recupera DGT retains the simplicity of management, programming and regulation of the traditional boiler and imports the savings of the condensing boiler resulting from the recovery of heat from the fumes. The heat recovery unit preheats the system water with the heat released by the fumes, heat which in traditional boilers is dispersed into the environment. This recovery of energy from the fumes, at typical operating temperatures of radiator systems, leads Recupera DGT to have higher yields than traditional boilers. Characteristics: High efficiency ( ( compliant with 92/42 EEC directive and Legislative Decree 311/06,¶½ Primary laminated copper heat exchanger with large exchange surface, double circulation Aluminum heat recovery unit to exploit the heat of the fumes and transfer it to the water Sanitary plate heat exchanger in stainless steel High efficiency pump with low energy consumption digital control panel with backlit display Electronic board for:ÿ Restart frequency adjustmentÿ Adjustable primary circuit thermal inertia disposalsÿ Circulator mode selectionÿ Circulator anti-seizeÿ Frost safetyÿ Chimney sweep function Integrated automatic by-pass Immunity to radio interference Magnetic sanitary flow Absolute heating pressure switch Degrees of protection IPX4D Heat recovery The heat recovery recovers the heat from the fumes before they are expelled and preheats the water directed to the primary exchanger. The recuperator made of aluminum has a finned coil which determines a large exchange surface and has a device to ensure that the boiler discharges the condensate correctly. Four-controllers Summer/winter/off selector Heating temperature regulator DHW temperature regulator Digital and analog pressure reading DHW and heating temperature visualization from the display Fault diagnostics display, fault history block status View recommended fill Display annual periodic maintenance expiry All ready for Energy Labeling What is it about From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy intensive sectors: construction For placing on the European market, the directive on ÿeco-designÿ(ErP notcome®ÿEnergy Related Productsÿ¯) imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres or As in the household appliances sector, the energy labelingÿof products, with a capacity of less than 70 kW, will give consumers simple, recognizable information which allows them to make comparisonsÿon the performance and energy consumption of the product they wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. It's about me tooÿ YES, it affects everyone: professionals and end users The information indicated on the energy labelÿwill allow professionals to recommend the right productÿÿindividuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015, the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. Supplier's responsibility The company that supplies the product on the market is required to equip its system devices with the following documentation: product energy label;ÿ product data sheet;ÿ system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices;ÿ technical data sheet of the system with the parts relating to the products and the system already completed. Responsibilities of Resellersÿ First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device/system to the public. Therefore, even professionals such as plumbers, installers, designers can fall into this category. All bound to ensure that: all appliances and/systems having their respective labels and making sure they are clearly visible;ÿ all appliances and/systems must always be accompanied by the obligatory technical data sheets;ÿ every type of advertising material, technical promotional material which shows energy data and price indications, contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and the production of hot water will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP): The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL There are different labels depending on the type of appliance. Those with efficiency classes A, A+ and A++ certify products with the highest performance. Furthermore, two different classifications are foreseen for domestic heating and for hot water production services, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the end customer can make his choice in the most aware way possible. SYSTEM LABEL In addition to the product label, the system label is also providedÿin cases where a series of appliances combined with each other is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label so as to inform the end user in the best possible way. Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€836,00
Biasi Gas Boiler Biasi Parva Recover E 24s Condensing Complete With Methane Fume Kit -New Erp
Overview BIASI PARVA RECUPERA E 24S METHANE CONDENSING BOILER - NEW ErP 2015, SEALED CHAMBER COMPLETE WITH FUME EXHAUST KIT: PARVA Recupera E ErP condensing boiler with heat recovery unit. Technical specifications Model:ÿPARVA Recover E 24S Product number:ÿ10312.2045.3 Energy label specifications according to the European ErPÿ directive Class B heating energy efficiency Sanitary energy efficiency Class A Withdrawal profiles: XL Characteristics of heating/sanitary exercises: Thermal input:ÿ25ÿkW Rated useful power: 24.3 kW Nominal load efficiency:ÿ97.2% Efficiency minimum load:ÿ95.1% Energy efficiency stars: (dir 92/42/EEC) **** Min/max heating temperature: 38/85ÿøC Capacity of the expansion vessel: 6 lt Sanitary flow rate t =25øK l/min: 13.9 l/min Degrees of protection for the electrical system:ÿIPX4D Extremely compact dimensions hxwxd: mmÿ803x400x350ÿ; 47.5kg METHANE power supply Features list ErP wall-mounted boilers with recuperator Redeveloping an old thermal systemÿ Biasi has designed the ÿPARVA Recupera NOx EÿandÿPARVA Recupera Eÿboilers to replace traditional boilers in old systems. The PARVA Recupera boilers by Biasi are equipped with a corrosion-resistant aluminum alloy fume recovery unit which makes these boilers particularly solid. The recovery unit is made of aluminium, has a finned coil which determines a large exchange surface and is equipped with a device to ensure that the boiler discharges the condensate correctly. The recuperator is treated with a Teflon coating process to ensure maximum durability over time. Thanks to the large exchange surface, the recuperator allows the recovery of thermal energy which would otherwise be dispersed outside through the hot fumes produced by combustion. PARVA Recover E PARVA Recupera E is the condensing boiler designed for traditional systems and easily adaptable to new floor-based systems using MULTIZONE, a hot water distribution system for heating. PARVA It recovers the traditional boiler in the regulations but it has clearly higher efficiency than the traditional boilers at the same operating temperature. As a condensing boiler, PARVA Recupera allows you to take advantage of the tax deduction according to current legislation. Characteristics: High yields (in compliance with yield directive 92/42 EEC and Legislative Decree 311/06ÿ Primary laminated copper heat exchanger with large double circulation exchange surfaceÿ Aluminum heat recovery unit to exploit the heat of the fumes and transfer it to the waterÿ Sanitary plate heat exchanger in INOXÿ steel High efficiency pump with low energy consumptionÿ retractable control panel, with ergonomic knobs and backlit displayÿ Electronic board for:ÿ - Re-ignition frequency adjustmentÿ - Adjustable primary circuit thermal inertia disposalsÿ - Selection of circulator modeÿ - Circulator anti-seizeÿ - Antifreeze safetyÿ - Chimney sweep functionÿ Integrated automatic by-passÿ Immunity to radio interferenceÿ Sanitary flowstat magneticÿ Absolute heating pressure switchÿ Degrees of protection IPX4Dÿ Possibility of integrating PARVA Recupera E with Biasi solar systems using the optional solar kit. Fiscal detraction As a condensing boiler, PARVA Recupera E allows you to take advantage of the tax deduction according to current legislation.ÿÿ Heat recoveryÿ The heat recovery recovers the heat from the fumes before they are expelled and preheats the water directed to the primary exchanger. The recuperator made of aluminum has a finned coil which determines a large exchange surface and has a device to ensure that the boiler discharges the condensate correctly.ÿÿ Thermoregulation By connecting the external probe (optional) directly to the boiler, you can access the climatic adjustment function. The boiler is equipped with a complete set of curves which can be accessed by entering programming. By simply turning a knob you choose the curve, PARVA recovers and will automatically adapt its operation to the external climatic conditions.ÿÿ High circulation primary heat exchangerÿ It is the element that distinguishes the whole PARVA E Biasi range. It favors the flow of water into the heating system and, thanks to its reduced hydraulic resistance, adapts the boiler to the system, facilitating the transmission of heat to the radiators.ÿ Savings simplicity of use Parva Recupera retains the simplicity of management, programming and regulation of the traditional boiler and imports the savings of the condensing boiler resulting from the recovery of heat from the fumes. The heat recovery unit preheats the system water with the heat released by the fumes, heat which in traditional boilers is dispersed into the environment. This recovery of energy from the fumes, at operating temperatures typical of radiator systems, leads Parva Recupera to have higher yields than traditional boilers. Low complexity, high comfort Parva Recupera boilers, despite the high technical content, are still very simple to use. Theÿcontrol panelÿhas two knobs dedicated to regulating the temperature of the domestic hot water and the heating water, the key to reset the boiler after the lockout status, the new display to view the boiler operating status and make it easier for the user to understand and installer settings . Fault diagnostics allow immediate verification of correct operation. The manometer allows you to check the system pressure while the temperature is shown on the display. Everything is hidden under a door that defines the sober and linear aesthetics of Parva Recupera. Included in delivery Boiler support bracket and paper templateÿ Condensate collection trapÿ Quick instruction to the user.ÿ All ready for Energy Labeling What is it about From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy intensive sectors: construction For placing on the European market, the directive on ÿeco-designÿ(ErP notcome®ÿEnergy Related Productsÿ¯) imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres As in the household appliances sector, the energy labelingÿof products, with a capacity of less than 70 kW, will give consumers simple, recognizable information which allows them to make comparisonsÿon the performance and energy consumption of the product they wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. It's about me too YES, it affects everyone: professionals and end users The information indicated on the energy labelÿwill allow professionals to recommend the right productÿÿindividuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015, the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. Supplier's liability The company that supplies the product on the market is required to equip its system devices with the following documentation: product energy label;ÿ product data sheet;ÿ system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices;ÿ technical data sheet of the system with the parts relating to the products and the system already completed. Responsibilities of Resellersÿ First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device/system to the public. Therefore, even professionals such as plumbers, installers, designers can fall into this category. All bound to ensure that: all appliances and/systems having their respective labels and making sure they are clearly visible;ÿ all appliances and/systems must always be accompanied by the obligatory technical data sheets;ÿ every type of advertising material, technical promotional material which shows energy data and price indications, contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and the production of hot water will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP): The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL There are different labels depending on the type of appliance. Those with efficiency classes A, A+ and A++ certify products with the highest performance. Furthermore, two different classifications are foreseen for domestic heating and for hot water production services, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the end customer can make his choice in the most aware way possible. SYSTEM LABEL In addition to the product label, the system label is also providedÿin cases where a series of appliances combined with each other is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label so as to inform the end user in the best possible way. Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€930,00
Biasi Biasi Gas Boiler Recovers Dgt 24s LPG Condensing Complete With LPG Fume Kit -New Erp
NB: ITEM OUT OF PRODUCTION, IN CASE OF LACK OF PRODUCT WE WILL SHIP THE NEW MODEL MODEL --> BASICA COND 25 ---> https://www.climaconvenienza.it/it/caldaia-biasi-basica-cond-25s-a -condensing-complete-with-gas-exhaust-kit-methane-low-nox-erp-news/ Energy label specifications according to the European ErP directive Class B heating energy efficiency Sanitary energy efficiency Class A Withdrawal profile: XL Characteristics of heating/DHW operation: Heating / domestic hot water nominal heat input kW 25.0 Heating / domestic hot water maximum useful power kW 24.4 Energy efficiency n° ★★★★ NOx class n° 2 Minimum / maximum heating temperature ** °C 40 / 85 Expansion vessel capacity (total / useful) l 8.0 / 4.0 Maximum flow rate (T=25 K) / (T=35 K) l/min 13.9 / 10.0 Degree of protection n° IPX4D Height x Width x Depth mm 803x400x350 CNG or LPG power supply RECOVER DGT Wall mounted condensing boilers Recupera DGT is the condensing boiler designed for traditional systems and easily adaptable to new underfloor systems using Multizone, a hot water distribution device for heating. Recupera DGT maintains the simplicity of management, programming and regulation of the traditional boiler and imports the savings of the condensing boiler deriving from the recovery of heat from the fumes. The heat recovery unit preheats the system water with the heat released by the fumes, heat which in traditional boilers is dispersed into the environment. This recovery of energy from the fumes, at typical operating temperatures of radiator systems, leads Recupera DGT to have higher yields than traditional boilers. Characteristics: High efficiency ( (★★★★ compliant with efficiency dir. 92/42 CEE and Legislative Decree 311/06 • Copper lamellar primary exchanger with large exchange surface and double circulation Aluminum heat recovery unit to exploit the heat of the fumes and transfer it to the water Sanitary plate heat exchanger in stainless steel High efficiency pump with low energy consumption Digital control panel with backlit display Electronic card for: - Restart frequency adjustment - Adjustable primary circuit thermal inertia disposal - Circulator mode selection - Circulator anti-seize - Antifreeze safety - Chimney sweep function Integrated automatic by-pass Immunity to radio interference Magnetic sanitary flow switch Absolute heating pressure switch IPX4D degree of protection Heat recovery The heat recovery recovers the heat from the fumes before they are expelled and preheats the water directed to the primary exchanger. The recuperator is made of aluminium, has a finned coil which determines a large exchange surface and has a device to ensure that the boiler discharges the condensate correctly. Thermoregulation By connecting the external probe (optional) directly to the boiler, climatic regulation can be used. Recupera DGT will adapt the system water temperature to the external climatic conditions, ensuring that the desired room temperature is reached without waste and optimizing consumption. By using the climatic regulation, the regulation efficiency is also raised, giving greater value to your home. Control panel Summer/winter/off selector Heating temperature regulator DHW temperature regulator Digital and analog pressure reading DHW and heating temperature visualization from the display Display of fault diagnostics, block status and fault history Recommended fill display Display annual periodic maintenance expiry All ready for Energy Labeling What is it about? From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy-intensive sectors: construction For placing on the European market, the eco-design directive ( ErP known as « Energy Related Products ») imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres As in the household appliances sector, the energy labeling of products with a capacity of less than 70 kW will give consumers simple, recognizable information which allows for comparisons on the performance and energy consumption of the product you wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. Is it about me too? YES, it affects everyone: professionals and end users The information indicated on the energy label will allow professionals to recommend the right product and individuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015, the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. Supplier responsibility The company that supplies the product on the market is required to equip its devices or systems with the following documentation: product energy label; technical product sheet; system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices; technical data sheet of the system with the parts relating to the product or system already completed. Dealer Responsibility First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device and/or system to the public. Therefore even professionals such as plumbers, installers or planners can fall into this category. Everyone is required to ensure that: all appliances and/or systems have their respective labels and make sure that they are clearly visible; all devices and/or systems are always accompanied by the mandatory technical data sheets; any type of advertising, promotional or technical material showing energy data or price indications contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and hot water production will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP) : The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL Depending on the type of device, there are different labels. Those with efficiency classes A, A+ and A++ certify the products with the highest performance. Furthermore, two different classifications are envisaged for domestic heating and for the hot water production service, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the final customer can make his choice in the most informed way possible. SYSTEM LABEL In addition to the product label, the system label is also provided if a series of matched appliances is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label in order to inform the end user in the best possible way. Warranty All products for sale on our site are new and packed. The guarantee on this item is 24 months from the date of purchase.
€866,00
Biasi Biasi Gas Boiler Renew Cond XE 25s Condensing Complete With Methane Fume Exhaust Kit -New Erp
Overview BIASI rinNOVA COND XE 25S CONDENSING BOILER COMPLETE WITH LPG METHANE FUME EXHAUST KIT - NEW ErP Technical specifications Model: rinNOVA COND XE 25S Energy label specifications according to the European ErP directive Class A heating energy efficiency Sanitary energy efficiency Class A Withdrawal profiles: XL Characteristics of heating/sanitary exercises: Thermal powerÿuseful sanitaryÿ(80/60ø C)ÿkW (kcal/h)ÿ26.6 (22,876) Heating capacityÿuseful heatingÿ(80/60ø C)ÿkW (kcal/h) 21.2 (18,232) Heat input(*)ÿnominalÿkW (kcal/h)ÿ25.0 (21,500) Heat inputÿminimumÿkW (kcal/h)ÿ6.0 (5,159) Sanitary flowÿt =25øKÿl/min 15.9 Dimensions (HxWxD) 700x400x290 mm Main features renew COND Xÿ RinNova Cond X The BIASI premixed condensing range completes: perfectÿfor underfloor systems for radiator systems, the compact condensing boiler that ensures high yields, low consumption and respect for the environment. Availableÿfor heating and domestic hot water production, in powers of 25 and 35 kW and forÿheating only in powers of 16, 25 and 35 kW. Characteristics: High yields (in compliance with yield directive 92/42 EEC and Legislative Decree 311/06) Sanitary comfortÿÿ(EN 13203) Primary and condensing exchanger in stainless steel with plastic linings to offer maximum resistance to corrosion Total premix burner, built in stainless steel (class NOx 5) Sanitary plate heat exchanger in stainless steel High efficiency pump with low energy consumption Maximum power adjustable according to the needs of the system Degrees of protection IPX5D Installability in a partially protected place Integration with BIASI solar systems using a solar kit digital control panel with backlit display Digital pressure reading by pressure transducer Arrangement for external probe remote control Four-controllers Summer/winter/off selector Heating temperature regulator DHW temperature regulator Digital pressure reading DHW and heating temperature visualization from display Display of fault diagnostics, fault history block status View recommended fill View annual maintenance expiry The display operates according to the modes: 1. INFO. Inf mode displays the following information: External temperature (in case of connected external probe) K value (in case of connected external probe) Sanitary / heating temperatures chosen by the user Smoke temperatures. 2. PROGRAMMING. The programming mode allows you to modify the boiler parameters. In chimney sweep mode it is possible to test the boiler and make adjustments to the gas valve. RinNova Cond XE: Adjustable maximum power The adjustable maximum useful heating power parameter meets the needs of modern construction without compromising comfort required in the production of domestic hot water. In fact, this function makes it possible to limit the maximum useful power in heating, independently of the useful domestic power. Hot water even with the sun RinNova Cond XE for heating and hot water production: the sanitary exchangerÿin stainless steel combined with the electronic management and low inertia of the primary exchangerÿdetermine excellent performance even in the production of domestic hot water.ÿFor the production of domestic hot water RinNova Cond XE can be combined with BIASI solar systems using specific solar kit (optional). The boiler cuts in only when necessary, making the most of solar energy and guaranteeing the comfort required by the user. Included in delivery: Boiler support bracket and paper template Boiler power cable Condensate collection siphon Quick instruction to the user. All ready for Energy Labeling What is it about From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy intensive sectors: construction For placing on the European market, the directive on ÿeco-designÿ(ErP notcome®ÿEnergy Related Productsÿ¯) imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres or As in the household appliances sector, the energy labelingÿof products, with a capacity of less than 70 kW, will give consumers simple, recognizable information which allows them to make comparisonsÿon the performance and energy consumption of the product they wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. It's about me tooÿ YES, it affects everyone: professionals and end users The information indicated on the energy labelÿwill allow professionals to recommend the right productÿÿindividuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015, the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. Supplier's responsibility The company that supplies the product on the market is required to equip its system devices with the following documentation: product energy label;ÿ product data sheet;ÿ system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices;ÿ technical data sheet of the system with the parts relating to the products and the system already completed. Responsibilities of Resellersÿ First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device/system to the public. Therefore, even professionals such as plumbers, installers, designers can fall into this category. All bound to ensure that: all appliances and/systems having their respective labels and making sure they are clearly visible;ÿ all appliances and/systems must always be accompanied by the obligatory technical data sheets;ÿ every type of advertising material, technical promotional material which shows energy data and price indications, contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and the production of hot water will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP): The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL There are different labels depending on the type of appliance. Those with efficiency classes A, A+ and A++ certify products with the highest performance. Furthermore, two different classifications are foreseen for domestic heating and for hot water production services, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the end customer can make his choice in the most aware way possible. SYSTEM LABEL In addition to the product label, the system label is also providedÿin cases where a series of appliances combined with each other is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label so as to inform the end user in the best possible way. Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€787,00