Wall Boilers
VAILLANT Vaillant Ecotec Plus Condensing Boiler Vmw 346/5-5+ LPG Complete With Smoke Exhaust Kit
LATEST QUANTITIES, CHECK AVAILABILITY IN ADVANCE BY CALLING THE OFFICES Technical features Model : EoTEC Plus VMW 346/5-5+ Code : 0010021994 Power : 34.0 kW Power supply: LPG Forced draft sealed chamber Performance Heating efficiency class: A Sanitary efficiency class: A Sanitary load profile : XL Nominal thermal power in DHW: 34.0 kW Efficiency at 30% : 109.0% Performance Stars : ★★★★ Class : NOx 5 Degree of protection : IP X4 D Expansion vessel capacity: 10 litres Domestic hot water production (ΔT = 30K) 16.2 l/min Power supply (V,Hz, Ø) : 220~240/50/1 Dimensions and weight Dimensions (HxWxD): 720x372x440 mm Weight : 40.0 Kg Vaillant condensing boiler With the strategic plan 20/20/20, Europe has the objective of producing 20% less CO2, using 20% more renewable energy and consuming 20% less primary energy. All this by 2020. To achieve these objectives, the EU has issued the ErP Directive (energy related products) which specifies the minimum eco-design requirements for equipment that uses energy, including energy efficiency. The world of heating will also be affected by this revolutionary change. In fact, from 2015 the energy efficiency of boilers will be based on new performance indexes that will take into account seasonal performance. Among the most significant changes to the new methodology for measuring seasonal efficiency are the introduction of different nominal temperatures, operation also at partial loads and in standby mode. The new methodology will make it possible to evaluate the performance of a boiler in real conditions, based on the level of efficiency calculated over an entire year. ecoTEC PLUS VMW+ The most efficient and versatile combi condensing boiler there is. ecoTEC plus. Wall-mounted condensing boilers capable of always guaranteeing maximum efficiency and maximum comfort. This is German quality. ecoTEC plus has always been the most popular Vaillant boiler. Today it guarantees even lower consumption, a further increase in efficiency and versatility and the certainty of immediate sanitary comfort without jolts. The best of Vaillant technology to satisfy every need Every component and every function of ecoTEC plus has been designed to combine efficiency and reduced consumption in favor of greater respect for the environment. ecoTEC plus self-adapts to your needs by always choosing the most economical solution, mixing the right amount of gas and air; all this with an electrical consumption of less than 2 Watts (less than half of a radio in operation). The combined version satisfies all comfort needs, guaranteeing both constant hot water without sudden changes in temperature and a comfortable climate. Sanitary comfort, in particular, is managed by the efficient Aqua Comfort pre-heating system which, thanks to 4 probes, controls, verifies and guarantees the immediate delivery of hot water always at the same temperature. Lots of hot water, immediately, without sudden changes is the real comfort offered by ecoTEC plus. From today it can also be installed outdoors where the climate is mild even in winter. In fact, the boiler has a standard antifreeze device which allows it to resist down to -5°C. To have heating and domestic hot water in a single solution The VMW ecoTEC plus condensing wall-mounted boilers combine the production of domestic hot water with the heating function. Unlike all the other boilers, the Vaillant ELGA system is installed inside, which expands the modulation range, but above all electronically regulates and monitors combustion to always ensure the lowest gas consumption, guaranteeing maximum efficiency. The boiler adjusts itself automatically and continuously, as if it were assisted every 30 seconds. In addition to a new, simpler and more intuitive design, the new electronics together with a very high efficiency pump make ecoTEC plus VMW+ the wall-mounted condensing boiler that consumes less on the European market. the ecoTEC plus VMW+ boiler is compatible with all Vaillant components and accessories already on the market. The dimensions are reduced 70cm high, 44cm wide and 35cm deep (identical to the previous version), the weight has been optimized making installation easier. and with vSMART... and go to Class A+ (Optional) All models of the ecoTEC plus VMW+ range have an efficiency etas = 94%. For this reason, if combined with a class VI thermoregulation (such as vSMART), they reach a system efficiency of 98% and therefore the ErP energy class in heating A+. Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.872,00€1.788,00
IMMERGAS Gas Boiler Immergas Victrix Maior 35 Tt Plus Condensing Natural Gas Heating Only With Smoke Exhaust Kit
IMMERGAS VICTRIX MAIOR 35 TT PLUS CONDENSING GAS BOILER FOR LPG HEATING ONLY WITH FUME EXHAUST KIT Technical features Product code: 3.024881 Typology: Heating only Class A heating energy efficiency Heating/DHW nominal heat input kW 34.9 Heating/DHW maximum nominal useful power kW 34.2 Useful thermal efficiency at 100% Pn (80/60 °C) 97.9% Useful thermal efficiency at 30% of the nominal load. (40/30°C) 108.5% Supply voltage/frequency: 230/50 Volt/Hz Expansion vessel 10 liters (real 7.1) Electrical insulation degree IP X5D Modulation range: 10 - 100% Boiler dimensions (HxLxP) mm 748 x 440 x 276 Empty boiler weight 35.8 kg Gas version available: LPG Product pluses: Wide modulation range Electronic ignition with ionization control Ideal for multiple withdrawals of domestic hot water (combined with a boiler) High hydraulic performance It integrates with solar systems VICTRIX MAIOR 35 TT PLUS Wall-mounted condensing boiler, for heating only with sealed chamber. Maximum comfort according to European standards. Combined with a boiler, it is ideal for simultaneous use of boiler water Particularly ideal for homes with multiple services or for all situations that require large withdrawals quickly, it guarantees a considerable production of domestic hot water. Boiler and Storage Unit can also be installed in different environments, thus increasing installation flexibility. It is characterized by the innovative primary exchanger which guarantees high flow rates and heads on the heating circuit, even when replacing old systems, with low risk of clogging , and by the presence of an "advanced" electronic card with electronic gas change ( without nozzle replacement) and self-adapting combustion control system. The new electronic card modulates the heating power of the boiler up to 12% and together with the low consumption circulator increases energy savings. The instantaneous models are equipped with a flow regulator and DHW inlet probe to obtain high DHW comfort: 3 stars *** according to the EN 13203 -1 standard. Also noteworthy is the wide range of modulation (from 10 to 100%) with high yields even in the presence of low energy absorption. The boiler also features an advanced and easy-to-use user interface with adjustment knobs, selection buttons and LCD display. Thanks to the condensing technology, it has a high efficiency and guarantees particularly low polluting emissions (NOX class 5). VICTRIX MAIOR TT PLUS is designed for outdoor operation in places partially protected from atmospheric agents (rain and snow) and is equipped with a standard antifreeze system which protects it down to a temperature of -5 °C (with optional kit up to - 15°C); moreover, it can be built -in inside the SOLAR CONTAINER or inside the home in the specific DOMUS CONTAINER technical cabinet: this allows for solutions such as GAUDIUM SOLAR PLUS V2 (only with “BASE” hydronic groups) COMFORT High hydraulic performance: the innovative condensing module guarantees high flow rate, low risk of clogging due to impurities in the system water, greater resistance to corrosion thanks to the special alloy. Boiler: prearranged as standard for combination with a boiler with a capacity of 80 to 2000 litres, it guarantees a high production of hot water. Thermoregulators: optional. They improve comfort and increase energy savings. DOMINUS app: optional. <strong">Simple and intuitive, it allows you to check the functioning and temperature of the boiler, switch it on and off from anywhere via smartphone or tablet. Via the optional Wi-Fi transmitter kit (code 3.026273), to be interposed to a wireless modem/router, it is possible to communicate from anywhere with the boiler circuit board. ENVIRONMENTAL COMPATIBILITY Eco-friendly technology: complies with the European ErP and ELD Directives, allows you to achieve high energy efficiency classes in heating and hot water production. Ecological class 5 (European Standards UNI 297 and 483): the best for reduced emissions of nitrogen oxides (NOX). Renewable energy: using a boiler with a capacity of 120 liters or more, the boiler can be connected to solar thermal systems for a greater production of hot water. Combination with thermal solar systems The Storage Tank Units with a capacity of 120 liters or higher are designed for combination with forced circulation thermal solar systems, including the UB INOX SOLAR 200 ErP version equipped with integrated solar circuit. VICTRIX MAIOR 35 TT PLUS can be connected to the entire range of Immergas Solar Solutions INSTALLATION High flexibility: approved to operate indoors and outdoors in partially protected places. IPX5D electrical protection. Standard antifreeze down to -5 °C. It is a very important directive established by the European Union and at the same time a decisive road that will lead all of Europe to reduce pollution and improve citizens' lives. The ErP directive (2009/125/EC) - the acronym stands for "Energy Related Products" - in fact sets very precise reference points for the manufacture of eco-compatible products and defines the minimum mandatory requirements for energy and environmental performance for instruments that consume energy. The goal is to reach the famous 20-20-20 by 2020. This repetition of the number 20 serves to more easily remind everyone of the three central purposes of the legislation: INCREASE THE ENERGY EFFICIENCY OF ENERGY USING MACHINES BY 20% REDUCE EMISSIONS OF CARBON DIOXIDE (CO2 ) INTO THE ATMOSPHERE BY 20% REACH A PERCENTAGE OF RENEWABLE ENERGY ON THE FINAL CONSUMPTION OF 20% Product Warranty: The warranty on this item is 24 months from the date of purchase.
€2.417,00
Ferroli Ferroli Floor Standing Boiler Bluehelix BS 45 Kw Natural Gas Or LPG Heating Only Complete With Fume Exhaust Kit 0tad5awa - New Erp
ATTENTION THE BOILER IS SUPPLIED WITH METHANE. CERTIFIED OPERATION ALSO ON LPG USING THE SPECIAL KIT TO BE REQUESTED IN ADVANCE FROM THE AUTHORIZED SERVICE CENTER OF THE AREA NB: PRODUCT AVAILABLE ON ORDER Ferroli Floor Standing Boiler Bluehelix BS 45 kW for natural gas or LPG heating only complete with Fume Exhaust Kit 0TAD5AWA - New ErP Thermal power 80°C-60°C Min / Max Heating 7.3 / 42.1 Useful thermal efficiency 80°C-60°C 98.0 / 97.8 Emission class Nox class 6 Class A+ in heating BLUEHELIX B on base > STRONG POINTS: It achieves one of the highest seasonal space heating efficiency in its category: ηs 94% (mod. 35 only) in combination with the modulating remote control and the external probe (optional) it reaches the higher efficiency class A+ (scale from G to A+++) (mod. 35 only) Primary heat exchanger in stainless steel Total premix burner in stainless steel with wide modulation range Low consumption modulating heating pump (Erp Ready - Class A) Digital controls with user interface display, multifunctional for easy and correct parameter setting Can be combined with the modulating remote timer control Easily accessible water and gas connections to facilitate the replacement of old generators Fumes discharge with split or coaxial pipes; possibility of left and right side exit, rear > BENEFITS OF BLUEHELIX B: Minimum polluting emissions (class 6 according to EN 15502-1) Sliding temperature operation in combination with the optional external probe Protection function of the exchanger with Δt control Timed circulator anti-blocking Digital flame control with three re-ignition attempts in the event of malfunction due to lack of flame detection (only in methane operation) Antifreeze function with standard protection down to -5°C Product Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase
€2.245,00
Savio Savio Aldens 35* Gas Condensing Boiler Complete With LPG Fume Kit
Overview SAVIO alDENS 35* CONDENSING BOILER COMPLETE WITH LPG FUME KIT LPG ideal for radiator systems - NEW ErP Technical specifications Model:ÿALDENS HE Technical data according to ErP directives Energy efficiency class in heating: A Sanitary energy efficiency class: A Load profiles: XLÿ Technical features: Minimum/Nominal useful power kWÿ4.3 ú 32.0 Minimum heat input with Methane/ Propaneÿ4,4 / 5,6 Efficiency class:ÿ Efficiency at nominal load in CONDENSATION % 102.3 Profitability at 30% of load% 98.1 NOx class 5 Operating temperature in heating min./maxøC 30 - 85 Adjustable temperature in sanitarywareøC 38 ú 60 DHW production mixed with t 25 l/min 18.3 Supply voltageÿV-Hz 230/50 Degrees of protection IP X5D Dimensions HxWxD mm 700x420x345; 36.5Kg Main features ALDENS ALDENS the new SAVIO range of condensing wall mounted boilers: excellent performance thanks to the aluminum heat exchanger and ease of use thanks to the control panel with knobs and display. Available in the combi version which combines the heating function and the production of domestic hot water. ALDENS presents a complete range of powers, 24 and 35 kW combi in the same extremely compact dimensions (700 x 420 x 345 mm). ALDENS has the strong point in the innovative primary heat exchanger in Al/Si/Mg with low water content designed to provide high yields that last over time. The digital display communicates the boiler operating parameters to the user in an easy and convenient way. Like the entire condensing range, SAVIO ALDENS allows you to make the most of savings from climatic thermoregulation, based on the system in which the boiler is installed. Main features: Outstanding fine 1:8 modulation ratio Efficiency>107% (ex dir. CE 92/42) Primary heat exchanger in ultra-flat Al/Si/Mg Electronics with HWS or Hot Water Speed function? Low NOx (class 5 according to EN 297 and EN 483) thanks to the modulating premix burner Production of fine hot water 13.3 l/min t 25 with special 12-plate (mod. 24 kW) and 16-plate (mod. 35 kW) exchanger in stainless steel Maintenance or Pit Stop? simple and intuitive control panel High efficiency modulating circulator (in line with ErP Dir. 2015) Sanitary exchanger Sanitary comfort ensured by the suitably sized plate exchanger to guarantee the best performance in terms of domestic hot water, reducing the waiting time and guaranteeing temperature stability. Modulating circulator with deaerator It represents the state of the art in the standard of high efficiency. In line with the ErP directive of 2015, with less than 1 W of consumption in stand-by and only 45 W in maximum operation, thanks to the wide modulation capacity, based on the request of the room thermostat and the temperatures detected by the sensors placed on the delivery/return automatically doses the boiler power to the needs of the system. Particularly silent and compact, it integrates with the safety valve, the by-pass and the drain cock. Exclusive Ai/Si/Mg heat exchanger It is made in a special Aluminum/Silicon/Magnesium alloy which ensures its efficiency and resistance over time. Thanks to the configuration of internal heat exchangers, efficiencies higher than 107% are achieved in the condensing regime, which means great economic savings and very low environmental impact for the user. The 35 kW version suitably increased. Plus Manage 2 zones with 2 thermostats:ÿALDENS versatile. Ideal for all systems, thanks to the electronics that allow you to manage 2 different temperature heating zones (high for radiators and fan-coils, low for radiant panel systems) by controlling them with dedicated modulating and on-off thermostats.ÿ Anti-overheating post-circulation:ÿFor 15 seconds, it maintains the thermal balance between delivery and return, even after intense DHW withdrawals, while in heating, with a duration of 5 minutes, it allows all residual thermal inertia to be disposed of.ÿ Sliding temperature operations:ÿFor maximum running economy.ÿ Antifreeze protection:ÿIt intervenes at 5°C and is activated in both domestic hot water and heating, bringing the temperature in the boiler to 15°C. The risk is avoided that ALDENS may freeze if low temperatures persist in the room where it is installed. If there is a lack of gas, the block signal will appear on the display.ÿ Pump anti-blocking: blocking of the pump following long stops is avoided thanks to an automatic 5-second pulse that the electronics sends to the motor every 24 hours of stop The multifunction LCD display, with timed backlighting, allows: Reading of the heating and sanitary temperatures Display of lockout due to lack of flame Error code display Malfunction signaling Operating/stand-by status Burner operating status Diagnostics with signaling of 11 anomalies Ecodesign directive: from 2015 on new condensing boilers In fact, after very long negotiations, the ÿEcodesign regulationÿ was approved, which introduces a new energy labeling on minimum efficiency standards for boilers.ÿIn particular, an energy classification from A+ to G is envisaged for space heating appliances and from A to G for appliances for the production of domestic hot water. ÿHence the obligation to installÿonly condensing boilers, heat generators capable of recovering a large part of the latent heat contained in the fumes which, otherwise, would be dispersed in the chimneyÿas occurs in traditional boilers. The recovered heat is transferred to the heating system, making it possible to achieve a yield of 106% with 92% of the traditional boiler and 84/85% of an oldÿÿtraditional generator.ÿThe installation obligation concerns manufacturers of boilers which will no longer be able to place on the market non-condensing starting from 26 September 2015. This means that starting from this date, anyone who wants to install a boiler in their own home will have to install only condensing models. Only one particular type of non-condensing boiler will continue to be produced which is technically called open room? to be installedÿ when it is not possible to replace an old boiler with a condensing boilerÿdue to problems related to the collective flueÿof some multi-family buildings. Products for heating water and the environment represent around 30% of the world's energy consumption in Europe.ÿ Designing eco-friendly products and promoting high performance technologies to end users in 2020 will lead to: An annual energy saving equivalent to 56 million tons of oil, quantifiable to the savings obtained if the water and environmental heating systems of two large nations like Italy were deactivated. As of 26 September 2015, the ErP regulation and ÿenergy labelingÿwill be applied in Europe to water and space heating products (boilers, heat pumps, micro-CHP devices, water heaters, and hot water storage tanks) u. How to read energy labels There are different labels, based on the type and function of the product (only room water heating of both, and in this case the label must bear both classifications). In addition to the energy class, the label provides other information that could be useful for understanding which product has the least environmental impact (for example power and consumption in different climatic zones, noise levels, etc.). It is possible to increase the energy efficiency of hot water production and space heating by connecting several products and accessories in one system. In this case it is necessary to prepare a system label in addition to that relating to the single product Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase. Shipping From the day payment is received, the product will be shipped within 3 working days. Free insured shipping for Italy. Shipping will take place via one of the national carriers
€1.174,00
Ariston Ariston Genus Premium Evo 35 Eu Condensing Boiler Complete With Methane Fume Exhaust Kit - Erp
ARISTON GENUS PREMIUM EVO 35 EU CONDENSING BOILER COMPLETE WITH METHANE FUME EXHAUST KIT - ErP Technical features Product code: 3300706 Energy label specifications according to the European ErP directive Class A heating energy efficiency Sanitary energy efficiency profile XL Class A Characteristics of heating/DHW operation: For heating and domestic hot water production Forced draft sealed chamber Nominal heat input in heating max/min kW 31/3.5 Max/min heating thermal power (80°C-60°C) kW 30.1/3.4 Efficiency at nominal heat input (60/80°C) % 97.7 Efficiency at nominal heat input (30/50°C) % 106.5 Efficiency at 30% at 30°C % 108.7 Performance stars (dir. 92/42/EEC) ★★★★ Min/max heating temperature (high temperature range) °C 35/ 82 Min/max heating temperature (low temperature range)°C 20/ 45 Specific flow rate in sanitary mode (10 min. with ∆T=30°C) litres/min 16.0 Quantity of hot water ∆T=25°C litres/min 19.3 Quantity of hot water ∆T=35°C litres/min 13.8 Comfort performance stars (EN13203) ★★★ Supply voltage/frequency V/Hz 230 / 50 Total absorbed electric power W 77 Degrees of protection of the electrical system IP X5D Dimensions (H x W x D) mm 770/400/385 CNG or LPG power supply Kit for conversion from methane to propane supplied Ariston condensing boilers 1 condensing boiler = -737kg CO2/year 1 condensing boiler = 60 more trees Together with the heat, a traditional boiler also produces water in the vapor state, usually evacuated through the exhaust fumes. Normal boilers, since they do not treat these fumes before releasing them into the environment, therefore have a thermal efficiency based exclusively on the lower calorific value. The water vapor is not recovered in any way, thus dispersing part of the energy produced during combustion. Condensation is the physical process which, inside the boiler, transforms the water again from the vapor state to the liquid one. CLAS PREMIUM EVO, exploits the phenomenon of condensation in its favor by reusing the energy of the exhaust fumes and increases the useful calorific value, thus reaching the thermal efficiency of over 107%. Furthermore, during this process, most of the harmful combustion products for the environment and health, they are eliminated together with the condensed water. Consistent convenience The new products, using condensing technology, eliminate waste with great energy and economic savings. Thanks to the savings in the bill, less than three years are enough to amortize the higher cost of a condensing boiler. After that, the lower consumption translates into a real gain. Imagine what a reduced bill of up to 35% every year, for many years, means for your economies... Zero waste, only benefits Today Ariston combines energy savings with tax savings, offering a great opportunity to those who have chosen to replace the old boiler with a condensing one. In fact, the Finance law provides for specific tax incentives in favor of taxpayers. EVO : energy saving becomes reality, for everyone's well-being Among the measures aimed at reducing the energy consumption of buildings (European Directive 2010/30/EC), the Italian legislation has introduced "The obligation of the energy certificate of the building" in the purchase and sale of new and existing buildings. They have also been extended until throughout June 2013, bringing them to a value of 50%, the "tax credit deductions relating to building renovations and energy efficiency interventions". For the purpose of achieving the national objectives envisaged on the coverage of consumption through renewable energy sources (European Directive 2009/28/EC) it also requires and promotes "the use of heating systems operating on renewable energy". With the EVO range, Ariston satisfies all the indications envisaged for having "low energy consumption buildings", guaranteeing optimal integration with systems using renewable energy. Genus Premium Evo The Genus Premium Evo wall-mounted boiler is the maximum expression of the Ariston range. Thanks to the condensing technology, by recovering the energy of the exhaust fumes, it generates an increase in the calorific value which makes it possible to eliminate waste (of energy) and to obtain higher thermal efficiency than conventional boilers. Genus Premium Evo offers even greater performance thanks to the innovative technology that allows it to self-regulate according to variations in the external and internal temperature of the room, allowing energy savings of up to 35% compared to an older generation boiler. It is available in the heating and domestic hot water production version in 3 powers: 24-30-35 kW (sealed chamber). Characteristics: Can be installed in partially protected places Large backlit dot matrix screen Continuous modulation high-efficiency circulator: for optimizing consumption and maximizing performance. Modulation ratio 1:10 - Automatic power regulation according to the heating request. Acoustic comfort guaranteed by the lower number of boiler on and off cycles, new silencer and sound-absorbing panels Prepared for integration in system configuration through the new Bus Bridgenet® communication protocol Arrangement for multi-zone and multi-temperature thermoregulation Arrangement for solar system management Car function and comfort Isothermal primary heat exchanger in stainless steel Increased sanitary exchanger Cold water inlet and heating return filters Convenience function: The Comfort function speeds up the delivery of domestic hot water, reducing waiting times down to just 5”. This service can be customized by choosing between two modes of use: COMFORT PLUS (hot water immediately ready every time the tap is opened in just 5 seconds) COMFORT (hot water ready for 30 minutes after the last withdrawal so as not to give up savings) car function: It is truly possible to combine maximum comfort with reduced consumption, thanks to the intelligent management logic of the new boilers and the new technology that governs them. By activating the AUTO function, the Ariston boiler chooses the best operating mode based on the environmental conditions, the connected external devices and the required performance. Impossible to compare this ability to interpret and respond to external stimuli with what has been achieved so far. AUTO does not fear comparisons Acoustic comfort Acoustic comfort is further guaranteed by the introduction of the new silencer. For the Clas Premium Evo thanks also to the high modulation ratio of 1:10, the continuously modulating pump and the presence of side sound-absorbing panels. High efficiency circulator with continuous modulation: It allows automatic adaptation of the power based on the temperature of the system, guaranteeing boiler performance and reducing electricity consumption. Optimization of thermal efficiency. Optimization of comfort with constant temperature. Maximum silence. High efficiency The condensing technology makes it possible to achieve high energy efficiency thanks to the increase in the calorific value generated by the reuse of the energy of the exhaust fumes, allowing for a higher thermal efficiency. The future of the planet and your comfort are the main objectives of Ariston condensing technology Product Guarantee All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.101,00
BERETTA Gas Boiler Beretta Exclusive 35c Methane Condensing Complete With Fume Exhaust Kit - Erp
NEW EXCLUSIVE EXCLUSIVE, A NEW STORY BEGINS. Through the innovative ACC electronic injection combustion, HYBRID READY integration and the new project design, EXCLUSIVE offers exclusive advantages in every installation variation. From the new EXCLUSIVE, A NEW STORY BEGINS. construction, redevelopment; from hybrid application in a multi-energy system to simple single installation, EXCLUSIVE represents the current and winning choice for those who are not satisfied and want to look beyond. Characteristics: Electronic injection combustion via ACC system EXCLUSIVE plus only the BeSMART Wi-Fi Comfort Control (optional) forms a class A+ system 94% (ETAs) of energy efficiency in heating Universal installation : Indoor, outdoor and recessed installation. IPX5D electrical protection degree Tempozero installation: Removing the casing NO longer necessary for electrical connections and calibration Low consumption modulating circulator (EEI≤ 0.20) 6 m head, electronically modifiable up to 7 m Hydraulic connections and external probe available as options Frost protection down to -5 °C as standard HYBRID READY boiler , Can be integrated via BUS in a multi-energy system to make boiler operation more effective in relation to other energy sources (can be combined with a Beretta hybrid system using the REC 10H interface available as an accessory) Talking display: User interface for direct communication using TEXT and ICONS Self-adapting: The boiler automatically adapts to different types of gas and installation - ZERO calibrations CO alarm Boiler CO level constantly monitored and calibrated for maximum safety Small size: Thanks to its compactness, EXCLUSIVE can also be easily installed in a wall unit LPG version selectable from parameter Gas transformation kit not necessary Europe strategy With the opening towards the management of multi-energy plants, the reduction of emissions and the optimization of consumption, Beretta signs with EXCLUSIVE the highest contribution in terms of respect for the environment, in view of the 20-20-20 objectives of the Union countries expected by 2020, reconfirming their commitment to an increasingly eco-sustainable future. Exclusive: a milestone in the evolution of Beretta Combustion and electronics, i.e. the heart and brain of EXCLUSIVE, entirely designed in the Research and Development Laboratories of the historic Lecco headquarters, mark a turning point in Beretta's mural evolution and are the result of the spirit of innovation that has distinguished the brand since its origins. With EXCLUSIVE, the novelty of the project fits perfectly into the tradition of know-how and takes on a linear design, which reworks some aesthetic lines of the first boiler models in a modern key, in perfect continuity of style. Continuity that is also manifested in the re-proposition of the EXCLUSIVE name, which has always characterized the top of the Beretta range, with exclusive features and advantages. Class A+ system using only the BeSMART WiFi Comfort Control (optional) . "talking" interface The control panel is one of the distinctive elements of EXCLUSIVE which confirms its innovative profile. In fact, there are many EXCLUSIVE functions, all to be discovered, through a modern 3.5” backlit LCD display, which communicates with the user through texts and icons. By means of the intuitive silk-screened operating keys it is also possible to access the settings and parameterizations of the boiler and the system. GREEN GEM OF EXCLUSIVE: LED light bar that signals the current operating status of the boiler, reflecting on the casing even with the door closed. Exclusive Features: HOURLY PROGRAMMING : Programmable heating by hour and by single zone INTELLIGENT SYSTEM FILLING Autonomous filling activation and total safety SYSTEM PRESSURE Displayed DATE AND TIME Display as screensaver PREHEATING Domestic hot water preheating activation SCHEDULED MAINTENANCE Intelligent system that warns the user when boiler maintenance is due Everywhere Exclusive: Thanks to BeSMART, Beretta's WiFi Comfort Control, controlling and managing home comfort is now possible wherever you are, through a simple and intuitive App, via smartphone and tablet. EXCLUSIVE is compatible with all BeSMART functions, even the most advanced. From home heating professionals, easy management of home comfort. Even away from home Electronic injection combustion The ACC system, designed and developed by Beretta, allows in all circumstances to offer "first class" functionality, efficiency and low emissions. Using a sensor for detecting the flame ionisation current, which allows the electronics to continuously modulate the quantity of fuel injected, the system keeps the air/gas mixture constant at optimal values over the entire modulation range of the delivered power. Thanks to the ACC system, combustion adjusts itself, thus eliminating the need for any calibration and allowing the boiler to operate with different gas compositions. Particular attention is paid to CO emissions, through a self-diagnosis that intervenes on the burner before the emission threshold allowed by the legislation is exceeded. [A] Cylindrical burner in stainless steel [B] Integrated electronic card [C] Traditional ga valve with modulator [D] Modulating fan with Hall effect Hybrid Ready EXCLUSIVE is a HYBRID READY solution. The boiler was born as a fundamental element of the offer of HYBRID READY products, which constitute the new hybrid technology system conceived and developed in the Beretta Research Laboratories. This system, created to meet the current and future needs of integration and governance of the various energy sources (Gas/Electricity/Renewables), also includes the most innovative methods of energy accumulation and distribution. EXCLUSIVE, AS A HYBRID READY SOLUTION, IS THE IDEAL CHOICE FOR THOSE WHO WANT TO LOOK AHEAD AND INVEST IN A PRODUCT WHICH WILL MAINTAIN ITS ITS VALUE UNCHANGED OVER TIME. Thanks to the new communication BUS with which it is equipped, EXCLUSIVE is able to interact perfectly with the Energy Manager REC 10H, a real thinking brain that constantly monitors the hybrid system created, to always offer the best comfort in an efficient and effective way. The Beretta hybrid, distinguishing itself for its modular approach to the world of multi-energies, is therefore able to offer increasingly tailored comfort and to evolve over time, with the inclusion of new components that increase efficiency Beretta is “ERP”. The concrete commitment towards an eco-sustainable future The acronym ErP, acronym of "Energy related Products" (Products connected to the use of energy), identifies the Directive 2009/125/EC aimed at reducing the energy consumption of products through eco-compatible design. Starting from 26 September 2015 , the date of its effective entry into force in the European Union, it will mark an epochal turning point for heating products and the production of domestic hot water. On that date, other regulations simultaneously issued for the energy labeling of products will also become effective in addition to the corresponding Directive 2010/30/EU. The regulation provides that all products intended for heating and for the production of domestic hot water with a nominal thermal power lower than or equal to 70 kW can only be placed on the market with an energy label that highlights the efficiency class * . Different energy efficiency labels have been provided based on the different types of appliances/technologies, but all have the same graduated color scale that identifies the various levels of efficiency at a glance. The purpose of the labels is to give the consumer the possibility to easily identify the level of efficiency of a product and to be able to make a homogeneous comparison between products that use different technologies. For products whose transformation efficiency is influenced by external conditions, such as heat pumps, the efficiency data is reported by climatic bands. In addition to the product labels, the European regulation has provided for the creation of a system label in case systems are created with different appliances, components and related controls. This second type of labeling, thanks to the virtuous synergy between the different elements, will make it possible to create systems capable of reaching levels of efficiency even higher than those of the individual appliances. Also starting from the same date, new seasonal efficiency limits will be triggered for products intended for heating and combined. These for products with a nominal thermal power equal to or less than 400kW, will prevent less efficient products from being placed on the market. The obligation to comply with minimum heat loss limits will also apply to DHW tanks. For primary water tanks, these will be subject to compliance with an energy classification based on heat dispersion. For sanitary accumulations, up to 500 liters there will be a labeling obligation, from 500 to 2000 liters will be bound to compliance with the energy classification. For heat pumps for heating and mixed appliances, in addition to the seasonal efficiency limits, there will be specific noise emission limits for power sizes. Even water heaters, whether gas, heat pump or solar, in order to be placed on the market, in addition to energy labelling, will have to comply with a series of requirements in terms of efficiency. Warranty All products for sale on our site are new and packed. The guarantee on this item is 24 months from the date of purchase.
€1.665,00