Wall Boilers
Biasi Biasi Gas Boiler Recovers Dgt 28s LPG Condensing Complete With LPG Fume Kit -New Erp
Overview BIASI RECOVERY BOILER DGT 28S CONDENSING LPG LPG - NEW ErPÿ Technical specifications Model: Retrieve DGT 28S Energy label specifications according to the European ErPÿ directive Class B heating energy efficiency Sanitary energy efficiency Class A Withdrawal profiles: XL Characteristics of heating/sanitary exercises: Heating/sanitary nominal heat inputkW 29.0 Maximum useful heating/sanitary powerkW 28.3 Energy efficiencynø NOx class no. 2 Minimum / maximum heating temperature**øC 40 / 85 Capacity of expansion vessel (total / useful) l 8.0 / 4.0 Maximum flow rate (T=25 K) / (T=35 K) l/minÿ16.3 / 11.6 Degrees of protection nø IPX4D Height x Width x Depth mm 803x400x350 LPG or LPG fuel supply Main features RECOVER DGTÿ ÿWall mounted condensing boilersÿ Retrieve DGTÿ theÿcondensing boilerÿdesigned for traditional systems and easily adaptable to new floor-based systems using Multizone, hot water distribution devices for heating. Recupera DGT retains the simplicity of management, programming and regulation of the traditional boiler and imports the savings of the condensing boiler resulting from the recovery of heat from the fumes. The heat recovery unit preheats the system water with the heat released by the fumes, heat which in traditional boilers is dispersed into the environment. This recovery of energy from the fumes, at typical operating temperatures of radiator systems, leads Recupera DGT to have higher yields than traditional boilers. Characteristics: High efficiency ( ( compliant with 92/42 EEC directive and Legislative Decree 311/06,¶½ Primary laminated copper heat exchanger with large exchange surface, double circulation Aluminum heat recovery unit to exploit the heat of the fumes and transfer it to the water Sanitary plate heat exchanger in stainless steel High efficiency pump with low energy consumption digital control panel with backlit display Electronic board for:ÿ Restart frequency adjustmentÿ Adjustable primary circuit thermal inertia disposalsÿ Circulator mode selectionÿ Circulator anti-seizeÿ Frost safetyÿ Chimney sweep function Integrated automatic by-pass Immunity to radio interference Magnetic sanitary flow Absolute heating pressure switch Degrees of protection IPX4D Heat recovery The heat recovery recovers the heat from the fumes before they are expelled and preheats the water directed to the primary exchanger. The recuperator made of aluminum has a finned coil which determines a large exchange surface and has a device to ensure that the boiler discharges the condensate correctly. Four-controllers Summer/winter/off selector Heating temperature regulator DHW temperature regulator Digital and analog pressure reading DHW and heating temperature visualization from the display Fault diagnostics display, fault history block status View recommended fill Display annual periodic maintenance expiry All ready for Energy Labeling What is it about From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy intensive sectors: construction For placing on the European market, the directive on ÿeco-designÿ(ErP notcome®ÿEnergy Related Productsÿ¯) imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres or As in the household appliances sector, the energy labelingÿof products, with a capacity of less than 70 kW, will give consumers simple, recognizable information which allows them to make comparisonsÿon the performance and energy consumption of the product they wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. It's about me tooÿ YES, it affects everyone: professionals and end users The information indicated on the energy labelÿwill allow professionals to recommend the right productÿÿindividuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015, the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. Supplier's responsibility The company that supplies the product on the market is required to equip its system devices with the following documentation: product energy label;ÿ product data sheet;ÿ system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices;ÿ technical data sheet of the system with the parts relating to the products and the system already completed. Responsibilities of Resellersÿ First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device/system to the public. Therefore, even professionals such as plumbers, installers, designers can fall into this category. All bound to ensure that: all appliances and/systems having their respective labels and making sure they are clearly visible;ÿ all appliances and/systems must always be accompanied by the obligatory technical data sheets;ÿ every type of advertising material, technical promotional material which shows energy data and price indications, contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and the production of hot water will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP): The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL There are different labels depending on the type of appliance. Those with efficiency classes A, A+ and A++ certify products with the highest performance. Furthermore, two different classifications are foreseen for domestic heating and for hot water production services, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the end customer can make his choice in the most aware way possible. SYSTEM LABEL In addition to the product label, the system label is also providedÿin cases where a series of appliances combined with each other is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label so as to inform the end user in the best possible way. Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€881,00
Ferroli Ferroli Divacondens D F24 LPG Condensing Boiler Complete With Smoke Exhaust Kit
LPG operation with the use of a special conversion kit to be requested from the Authorized Assistance Centre, we recommend contacting the local assistance center before purchasing In case of unavailability we will supply the new model DIVACONDENS D PLUS F24 LOW NOx Technical features Model : Divacondens D F24 Power supply: LPG Energy efficiency Heating energy efficiency class: B Sanitary energy efficiency class: A ACS profile : XL Performance Heat output : 10.0 ~ 25.0 kW Thermal power 80°C ~ 60°C : 9.2 ~ 24.1 kW Thermal power 50°C ~ 30°C : 9.6 ~ 25.9 kW Useful thermal efficiency 80°C ~ 60°C : 92.0% ~ 96.5% Useful thermal efficiency 50°C ~ 30°C : 96.0 ~ 103.5% NOx emissions : 3 Maximum production of domestic hot water Δt 25°C : 14.0 l/min Maximum production of domestic hot water Δt 30°C : 11.6 l/min Heating working pressure: 0.8 ~ 3 bar Sanitary operating pressure: 9 bar Dimensions and weight Dimensions (LxHxP): 400x680x330 mm Empty weight: 35.0 kg 5 years without worries Extension of the manufacturer's standard warranty to 5 YEARS on Ferroli brand gas condensing boilers of less than 35 kW in the DIVACONDENS and BLUEHELIX series through the local authorized Ferroli technical assistance centre. Wall mounted boiler Ferroli DIVACONDENS Wall mounted condensing boiler with instantaneous production of domestic hot water The simplest solution for a condensing boiler DIVACONDENS is the condensing heat generator for traditional heating systems. The tried and tested Ferroli technology in the field of traditional wall mounted boilers has been enriched by increasing the performance of the product in the simplest way, with the use of a robust recuperator which preheats the primary circuit using the residual heat of the exhaust fumes. The quality of the DIVACONDENS line is unquestionable, and Ferroli is ready to put it to the test by offering its customers extended warranty coverage which also ensures periodic maintenance and legal checks Product plus > Forced draft boiler, atmospheric burner in AISI 304 stainless steel, for traditional medium and high temperature systems . It is not suitable for combination with direct delivery to systems with low temperature radiant panels > Multi-zone management possible with the use of the Ferroli FZ4 control unit > Double exchanger : copper primary with aluminum cladding; secondary in stainless steel for domestic hot water > Exhaust gas heat recovery unit , for pre-heating the primary circuit > Backlit liquid crystal display that is easy to use for the user > Possible combination with modulating remote control > High efficiency circulator for the primary circuit, synchronous motor with low operating noise and torque control > Timed anti-blocking system of the circulator and the diverter valve > Domestic hot water pre-heating function for rapid delivery to the user > Smoke accessories in special polypropylene , less prone to thermal expansion than metal ones, as well as being immune to corrosion and easy to connect. Their integrity is controlled by the fume thermostat > Suitable for installation in particularly harsh climates, thanks to the condensate collection device which protects the air pressure switch from humidity > Connection to solar thermal systems : set up for the production of domestic hot water combined with solar panels > IPX5D protection index, which means excellent electrical protection of the luminaire against the intrusion of liquids and foreign bodies Boiler control The DIVACONDENS control box consists of an easy-to-use interface with a backlit display. Using the buttons, it is possible to easily adjust the heating flow temperature, the domestic hot water setpoint, switch the generator on/off or activate the comfort function, monitoring the status of the boiler. The control panel is completed by a traditional pressure gauge which can check the system pressure at any time. Main components Condensate trap Protects the air pressure switch from external humidity Recovery unit with condensate drain Steel frame Made with high precision automated processes. Incorporates an 8 liter expansion tank Copper central heating primary exchanger , protected by a non-toxic aluminum coating Burner Made of AISI 304 stainless steel ramps. Modulation takes place both in heating and in the production of domestic hot water High efficiency circulator , for heating and exchange with the DHW circuit High efficiency domestic hot water exchanger , for heating and exchange with the domestic hot water circuit Optimize comfort and savings "ROMEO" timer control The Romeo remote control allows control and setting of the boiler functions directly from the room in which it is installed. Comfort programming is possible on a weekly basis and also includes the 'holiday' function. Romeo is available with wired or wireless connection. The ROMEO modulating function allows boiler output to be modulated as the set room temperature value is reached. This improves the quality of comfort by eliminating heat peaks with consequent energy savings. Solar circuit integration Sun Easy function DIVACONDENS boasts electronics that simplify integration with thermal solar systems, both with natural and forced circulation. The microprocessor controls the temperature of the water coming from the solar circuit through the domestic hot water sensor and turns on the burner only if necessary. In case of insufficient irradiation and therefore a modest pre-heating of the domestic water, the boiler will contribute with the heat necessary to reach the required setpoint temperature If the sun and the solar system fulfill their "duty" no integration by the boiler will be necessary, the hot water will be conveyed to the tap, without the need for additional devices, with the mixing of the thermostatic valves. To reach the desired temperature, SUN EASY allows considerable savings even during the coldest seasons, exploiting and integrating even the smallest solar contribution, otherwise lost. Safety and comfort Functions Antifreeze In the event that the temperature in the boiler drops to 5°C, the burner ignites automatically and the circulator is activated in order to protect the appliance from damage caused by freezing. This function is active with the boiler powered by the gas circuit and under electrical voltage Post-circulation This function makes it possible to recover all the heat supplied by thermal inertia of the exchanger and transfer it to the heating system, and consequently to the rooms to be heated. This is a timer function and is active after the burner goes out in heating mode. Opentherm The DIVACONDENS electronic board adopts the Opentherm protocol. It allows the integration of other peripheral control units, such as, for example FZ4 - multi-zone manager - or Romeo - remote timer control. In fact, the Opentherm standard has been specially designed to share the logic and operating algorithms of the boiler with other additional control units. As a digital protocol, it allows total integration between the boiler and the satellite, with full control of the functions from the boiler and similarly from its satellite Product Guarantee : All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€580,00
Riello Riello Family Ar 29 Kis Methane Condensing Boiler Complete With Smoke Kit - New Erp
Overview RIELLO FAMILY AR 29 KIS METHANE CONDENSING BOILER COMPLETE WITH FUME KIT - NEW ErP 2015: Family AR the new generation condensing boiler specifically designed to operate with high temperatures (delivery 80°C and return 60°C) and therefore in radiator systems Technical specifications Product code:ÿ20100511 Energy label specifications according to the European ErP directive Class B heating energy efficiency Sanitaryware energy efficiencyprofilXL Class A Characteristics of heating/sanitary exercises: Firebox thermal power (heating)ÿmin-max: 9.9ú29.0ÿkW Useful thermal power (sanitary) min-max: 9.9ú29.0ÿkW Energy efficiency(92/42/CEE)ÿ**** Efficiency useful at Pn* (50øC-30øC): 97.1% Profitability 30% (47ø return): 96.2% Sealed chamber, forced draft Quantity of hot water at t 25°C: 16.6 l/min Minimum domestic water flow rate: 2ÿl/min Dimensions (hxwxd) mmÿ845 x 450 x 332 ; 44 kgs Electrical protection degrees: IP X5D NOx class: 2 Power supply: METHANEÿ Features list FAMILY AR Efficiency****ÿ Combined models for heating and domestic hot water production Family AR the new generation condensing boiler specifically designed to operate with high temperatures (delivery 80°C and return 60°C) and therefore in radiator systems. Family AR contains Altaresa condensing technology in the aesthetics and in the special Family functions. Family AR features Air/Gas combustion (patented): thanks to the modulating fan, the mixture of air and gas is kept optimal and constant over all the power ranges, always keeping efficiency high. Thanks to the post-exchanger in treated aluminum, very high final efficiencies are obtained, 102.9%. The climatic regulation managed directly by the boiler control unit, via the external probe (accessory), allows the temperature of the heating system to be suitably adapted to the external climatic conditions. The equipment is completed by anti-gel systems (up to -3°C), circulator anti-blocking, three-way valve vie, TastBenessere and Tastrapid which reduces waiting times for domestic hot water. Family AR available with powers of 25, 29 and 35 kW. Features:ÿ Technology, ease of management controls: ,¶½ TastMemory: activates machine intelligence. - sanitary: hot water always ready and without waste, according to the family's habits. - in heating: reduction of home heating times. ,¶½ TastBenessere: keeps the hot water supply at the ideal temperature for the shower (40øC customizable +/- 5øC). ,¶½ Touch&Go function: directly from the tap, it activates the pre-heating for a single water withdrawal. ,¶½ Intelligent system filling: allows you to fill the system in complete autonomy. Air/gas combustion (patent):ÿoptimum mixture of gas and air to obtain high and constant efficiency over the entireÿpower range with final efficiency of 102.9%.ÿ Condensing exchanger placed downstream of the fan for further recovery of the heat contained in the exhaust fumes. ÿInstallation Benefits Performance secondDir. 92/42/EEC. Circulator lowconsum(IEE0,20) Climatic adjustment managed directly by the boiler control unitÿ Special Family functions: TastBenessere, TastMemory, Touch&Go function Smart Fillsÿ Assembly template, hydraulic fittings, power supply cable supplied ErP: Energy related Products ErP the acronym for Energy related Products? (products connected to the use of energy) and the abbreviation that identifies the European Directive ErP 2009/125/EC, defined by the EEC with the intention of reducing the energy consumption of products through eco-compatible design (or eco-design?). The scope of action of this European Directive is extremely broad since up to now it has affected products such as light bulbs, air conditioners, washing machines, fans, etc. Following the publication in September 2013 of a series of implementing regulations, starting from 26 September 2015 they will also apply to heating products and the production of domestic hot water. Also from the same date, other regulations will also become effective which will implement the energy labeling of the same product families. The transitional period between the publication of the regulations and their activation throughout the territory of the European Community is necessary to allow the full transposition of the contents by companies and market players. The regulations issued require that all products intended for heating and/for the production of domestic hot water, with a nominal thermal power lower than or equal to 70 kW, are placed on the market with an ÿenergy labelÿ that highlights their efficiency class. Note: the regulation provides for the mandatory presence of the energy label for the introduction of the product from the factories to the market. All the products previously introduced, for example present near distribution warehouses, can be regularly marketed even if they do not have an energy label. Various energy labels have been provided based on the use of the generator used: for heating from A++ to G; for the production of domestic hot water from A to G. The purpose of energy labels is to allow the consumer to easily identify the level of efficiency of a product, to be able to make a homogeneous comparison between products that use different technologies. For products whose transformation efficiency is influenced by external conditions, such as heat pump products, as well as those on air conditioners, the efficiency data reported for the average climatic zone. In addition to product energy labels, European regulations have also provided for the creation of a "system label" in the case of building a plant in which various appliances, components and controls operate. This labelling, thanks to the combinations of the data of the various elements used in the plant, will allow the creation of systems capable of reaching levels of efficiency even higher than those of the individual generators. The European regulation states that the system label must be made available by whoever supplies and/operates the system (sellers-installers); but this faculty is also granted to builders. Warranty All products for sale on our site are new and packed. The guarantee on this article is 24 months from the date of purchase.
€1.584,00
BERETTA Beretta CIAO AT 25 csi LX LOW NOx condensing boiler Complete with METHANE Flue Gas Kit code 20151635
Beretta CIAO AT 25 csi LOW NOx condensing boiler Complete with flue kit Cod. 20151635 Technical specifications according to ErP directives Model: HELLO AT LOW NOx Sanitary energy efficiency class: A Energy efficiency class in heating: B Load profile: XL Product code 20151835 Natural gas supply Technical features: Indoor/Outdoor installation Nominal heat input 25 kW Nominal thermal power 23.85 kW Electric Power: 114W New version NOx < 56 mg/kWh NOx class 6 IPX5D electrical protection degree Expansion tank capacity: 9 l Dimensions Dimensions h/w/d (mm): 780/400/336 HELLO AT new LOW NOx model Hi AT, ideal for replacement in systems with radiators Ciao AT is the innovative condensing boiler specifically designed by Beretta for traditional high temperature systems (radiators and radiators). The boiler is equipped with a heat recovery unit on the fumes and combustion in a sealed chamber; this allows to obtain very high performance in terms of efficiency and therefore a significant energy saving. New burner with low NOx emissions Specific for systems with radiators and radiators (at high temperature) Condensing post exchanger in aluminum alloy Possibility of outdoor installation with antifreeze heater kit (optional) IPX5D electrical protection degree Environmental Self-Regulation System (SARA) Low consumption circulator 6 m (EEI≤0.20) Hydraulic connections cover (optional) Condensate collection neutralizer drawer kit (optional) Template, hydraulic fittings, gas and sanitary taps (optional) High performance and low consumption In the Ciao AT boiler, the water in the primary circuit passes through an additional exchanger, which allows you to recover energy that would otherwise be wasted. This process makes it possible to recover latent heat and therefore to further increase the performance of the boiler. The energy saving offered by a boiler is greater the higher its efficiency: Ciao AT therefore allows you to reduce gas consumption compared to a boiler without an additional exchanger. The management The electronic panel is the interface for managing the boiler. Simple and intuitive, it allows you to adjust the boiler parameters and activate the numerous functions. The liquid crystal display provides information on the status of the device and the diagnostic codes. By turning the knobs, the heating water and domestic hot water temperature can be set easily and intuitively. The panel integrates the Sistema Clima Amico function. Compatible with BeSMART The BeSMART WiFi Comfort Control Panel, optional compatible with Ciao AT, is the remote boiler management device with modulating chronothermostat functions. With the WiFi Box accessory, included in the BeSMART WiFi Comfort Control, it is also possible to manage comfort remotely using Smartphones and Tablets. The BeSMART WiFi control is very simple to install and intuitive to use and allows you to adjust the parameters and activate the many functions on the boiler. A large liquid crystal display shows all important information. Using the buttons on the control, the temperature of the heating water and domestic hot water is set easily and intuitively and the heating time programming is carried out. Outdoor installation Ciao AT is designed to also be installed outdoors in partially protected places thanks to the dedicated accessories (bottom cover kit and top cover kit) and board antifreeze protection down to 0 °C. In colder temperatures it is possible to extend the protection down to -10 °C using the special antifreeze heater kit with which the lower cover is required. Product Guarantee All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€793,00
Biasi Biasi Gas Boiler Recovers Dgt 28s Methane Condensing Complete With Methane Fume Kit -New Erp
Overview BIASI RECOVERY BOILER DGT 28S CONDENSING METHANE LPG - NEW ErPÿ Technical specifications Model: Retrieve DGT 28S Energy label specifications according to the European ErPÿ directive Class B heating energy efficiency Sanitary energy efficiency Class A Withdrawal profiles: XL Characteristics of heating/sanitary exercises: Heating/sanitary nominal heat inputkW 29.0 Maximum useful heating/sanitary powerkW 28.3 Energy efficiencynø NOx class no. 2 Minimum / maximum heating temperature**øC 40 / 85 Capacity of expansion vessel (total / useful) l 8.0 / 4.0 Maximum flow rate (T=25 K) / (T=35 K) l/minÿ16.3 / 11.6 Degrees of protection nø IPX4D Height x Width x Depth mm 803x400x350 ÿMETHANEÿorÿLPG power supply Main features RECOVER DGTÿ ÿWall mounted condensing boilersÿ Retrieve DGTÿ theÿcondensing boilerÿdesigned for traditional systems and easily adaptable to new floor-based systems using Multizone, hot water distribution devices for heating. Recupera DGT retains the simplicity of management, programming and regulation of the traditional boiler and imports the savings of the condensing boiler resulting from the recovery of heat from the fumes. The heat recovery unit preheats the system water with the heat released by the fumes, heat which in traditional boilers is dispersed into the environment. This recovery of energy from the fumes, at typical operating temperatures of radiator systems, leads Recupera DGT to have higher yields than traditional boilers. Characteristics: High efficiency ( ( compliant with 92/42 EEC directive and Legislative Decree 311/06,¶½ Primary laminated copper heat exchanger with large exchange surface, double circulation Aluminum heat recovery unit to exploit the heat of the fumes and transfer it to the water Sanitary plate heat exchanger in stainless steel High efficiency pump with low energy consumption digital control panel with backlit display Electronic board for:ÿ Restart frequency adjustmentÿ Adjustable primary circuit thermal inertia disposalsÿ Circulator mode selectionÿ Circulator anti-seizeÿ Frost safetyÿ Chimney sweep function Integrated automatic by-pass Immunity to radio interference Magnetic sanitary flow Absolute heating pressure switch Degrees of protection IPX4D Heat recovery The heat recovery recovers the heat from the fumes before they are expelled and preheats the water directed to the primary exchanger. The recuperator made of aluminum has a finned coil which determines a large exchange surface and has a device to ensure that the boiler discharges the condensate correctly. Four-controllers Summer/winter/off selector Heating temperature regulator DHW temperature regulator Digital and analog pressure reading DHW and heating temperature visualization from the display Fault diagnostics display, fault history block status View recommended fill Display annual periodic maintenance expiry All ready for Energy Labeling What is it about From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy intensive sectors: construction For placing on the European market, the directive on ÿeco-designÿ(ErP notcome®ÿEnergy Related Productsÿ¯) imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres or As in the household appliances sector, the energy labelingÿof products, with a capacity of less than 70 kW, will give consumers simple, recognizable information which allows them to make comparisonsÿon the performance and energy consumption of the product they wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. It's about me tooÿ YES, it affects everyone: professionals and end users The information indicated on the energy labelÿwill allow professionals to recommend the right productÿÿindividuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015, the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. Supplier's responsibility The company that supplies the product on the market is required to equip its system devices with the following documentation: product energy label;ÿ product data sheet;ÿ system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices;ÿ technical data sheet of the system with the parts relating to the products and the system already completed. Responsibilities of Resellersÿ First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device/system to the public. Therefore, even professionals such as plumbers, installers, designers can fall into this category. All bound to ensure that: all appliances and/systems having their respective labels and making sure they are clearly visible;ÿ all appliances and/systems must always be accompanied by the obligatory technical data sheets;ÿ every type of advertising material, technical promotional material which shows energy data and price indications, contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and the production of hot water will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP): The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL There are different labels depending on the type of appliance. Those with efficiency classes A, A+ and A++ certify products with the highest performance. Furthermore, two different classifications are foreseen for domestic heating and for hot water production services, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the end customer can make his choice in the most aware way possible. SYSTEM LABEL In addition to the product label, the system label is also providedÿin cases where a series of appliances combined with each other is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label so as to inform the end user in the best possible way. Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€836,00
Riello Riello Family Ar 35 Kis Methane Condensing Boiler Complete With Smoke Kit - New Erp
RIELLO FAMILY AR 35 KIS LPG CONDENSING BOILER COMPLETE WITH FUME KIT - NEW ErP Technical features Product code: 20100513 Energy label specifications according to the European ErP directive Class B heating energy efficiency Sanitary energy efficiency profile XL Class A Characteristics of heating/DHW operation: Furnace thermal power (heating) min-max: 9.9÷34.8 kW Useful heat output (sanitary) min-max: 9.9÷34.8 kW Energy efficiency (92/42/EEC) **** Useful efficiency at Pn* (50°C-30°C): 97.5% Profit return 30% (47th return): 96.5% Sealed chamber, forced draught Quantity of hot water with Δt 25°C: 20 l/min Minimum domestic water flow rate: 2 l/min Dimensions (hxlxp) mm 845 x 500 x 332 ; 48 kgs Electrical protection degree: IP X5D NOx class: 2 Power supply: METHANE FAMILY AR Yield **** Combined models for heating and domestic hot water production Family AR is the new generation condensing boiler specifically designed to operate with high temperatures (80°C delivery and 60°C return) and therefore in radiator systems. Family AR contains Altaresa condensing technology in the aesthetics and in the special Family functions. Family AR has an Air/Gas combustion (patented): thanks to the modulating fan, the mixture of air and gas is kept optimal and constant over the entire power range, always maintaining high efficiency. Thanks to the treated aluminum post-exchanger, very high yields up to 102.9% are obtained. The climatic regulation is managed directly by the boiler control unit, via the external probe (accessory), it allows the temperature of the heating system to be suitably adapted to the external climatic conditions. The equipment is completed by anti-freeze systems (down to -3°C), circulator anti-blocking systems, three-way valve, Wellness button and rapid button which reduces the waiting times for domestic hot water. Family AR is available with powers of 25, 29 and 35 kW. Characteristics: Technology, ease of control and management: • Memory key: activates machine intelligence. - sanitary: hot water always ready and without waste, according to the usage habits of the family. - in heating: reduction of home heating times. • Wellness key: maintains hot water delivery at the ideal temperature for the shower (40°C customizable +/- 5°C). • Touch&Go function: directly from the tap, it activates pre-heating for just one water draw. • Intelligent system filling: allows you to fill the system in complete autonomy. Air/gas combustion (patented): optimal mixture of gas and air to obtain high and constant efficiency over the entire power range with efficiency up to 102.9%. Condensing exchanger located downstream of the fan for further recovery of the heat contained in the exhaust fumes. Advantages for installation: Efficiency ★★★★ according to Dir. 92/42/CEE. Low consumption circulator (IEE≤0.20) Climatic regulation managed directly by the boiler control unit Special Family functions: Wellness key, Memory key, Touch&Go function Intelligent system filling Assembly template, hydraulic fittings, power supply cable supplied. Product Guarantee All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase
€1.615,00
Ferroli Area Occasioni Condensing Boiler Ferroli Divacondens D Plus F24 Low Nox Methane Complete With Coaxial Flue Kit
ATTENTION THE PRODUCT IS NEW AND 100% WORKING, BUT HAS DENT ON THE TOP (SEE PHOTO NEXT TO THE MAIN IMAGE) NB The boiler will be supplied with methane, for LPG operation you must contact your local Authorized Assistance Centre. Technical features Model : Divacondens D Plus Nominal thermal power: 24 kW Power supply: methane Specifications Energy efficiency according to the European ErP directive Heating Energy Efficiency Class: B Seasonal Space Heating Energy Efficiency : 89% Performance Heating Thermal Capacity : 7,5 ~ 25,0 kW Heating Thermal Power: 7.2 ~ 24.2 kW Ultimate Thermal Efficiency 30% Pmin : 100.1% Domestic Hot Water Production 25°C Δt 30°C : 13,9 ~ 11,6 l/min NOx emissions 6 Dimensions and weight Dimensions (LxHxP): 400x700x330 mm Weight : 35Kg Ferroli Divacondens D Plus Boiler The Simplest Solution For A Condensing Boiler DIVACONDENS D PLUS is the condensing heat generator for traditional heating systems. The tried and tested Ferroli technology in the field of traditional wall mounted boilers has been enriched by increasing the performance of the product in the simplest way, with the use of a robust recuperator which preheats the primary circuit using the residual heat of the exhaust fumes and a new cooled burner with low NOx emissions. The Range Divacondens D Plus is offered in a single model for heating and instantaneous production of domestic hot water Characteristics > Condensing boiler for heating high temperature systems and producing domestic hot water. It is not suitable for combination with direct delivery to systems with low temperature radiant panels > Compact geometry primary exchanger > Instant production of domestic hot water with dedicated plate exchanger > Post-recovery of the latent heat of condensation, in function of pre-heating of the primary circuit > Forced draught sealed chamber boiler, with water-cooled atmospheric burner with low NOx emissions > Standard automatic hydraulic by-pass > Minimum polluting emissions (class 6 according to EN 15502-1) > High efficiency low consumption circulator (ErP - Class A) with anti-blocking system by activation for a few seconds every 24 hours of inactivity > Can be combined with the modulating remote timer control > Simple and complete control panel, display user interface, with setting keys > Robust post-condenser fed by the closed circuit of the primary. The heat exchange with the fumes takes place inside large diameter water passages. > Generator with simple and rational operation > ECO function in DHW for greater savings in the period of low use of hot water > Predisposition for solar systems: prearranged for the production of domestic hot water combined with solar panel systems > Place of installation: also for outdoors in a partially protected place down to -5°C as standard > Certified operation also with propane air (50% air - 50% G31) by means of a specific transformation to be requested from the Authorized Assistance Center > Also works on LPG with the use of a special conversion kit to be requested from the Authorized Assistance Centre Boiler control The DIVACONDENS D PLUS control unit consists of an easy-to-use interface with a backlit display. Using the buttons, it is possible to easily adjust the heating flow temperature, the domestic hot water setpoint, switch the generator on/off or activate the comfort function, monitoring the status of the boiler. The control panel is completed by a traditional pressure gauge which can check the system pressure at any time. The performances Energy classification DHW load profile (maximum flow rate at the corresponding efficiency declared in DHW) Efficiency in the production of domestic hot water FOR COMBINED BOILERS The "climate-energy 20/20/20" package sets ambitious targets for the reduction of greenhouse gas emissions, of energy consumption as well as the increase in the use of renewable energies, corresponding to a percentage of 20% to be reached by 2020. In this context, the European regulation ErP (Energy Related Products) introduces an energy classification also for water generators hot water for space heating and domestic hot water purposes. This classification translates into an energy label which must necessarily accompany all the products affected by the Regulation, introduced on the market from 26 September 2015. The labeling constitutes an easy guide for the consumer, who can choose - through standardized and objective indications - the product more efficient. In this way, the choice will be the most sparing in terms of consumption for the benefit of the user, but also the most virtuous for energy balances and consequently, for the environment. The most significant parameters indicated on the label are the seasonal efficiency index in heating and efficiency in the eventual production of domestic hot water, according to a scale which, in the case of the single boiler product, ranges from A to G*. Furthermore, for combined boilers, a load profile is indicated corresponding to the DHW flow rate of the appliance measured in a series of typical samplings, guaranteeing at least the declared DHW efficiency. This index is identified with a letter/”size” (S, M …XXL). Solar circuit integration DIVACONDENS D PLUS boasts electronics that simplify integration with thermal solar systems, both with natural and forced circulation. The microprocessor controls the temperature of the water coming from the solar circuit through the domestic hot water sensor and turns on the burner only if necessary. To reach the desired temperature, SUN EASY allows considerable savings even during the coldest seasons, exploiting and integrating even the smallest solar contribution, otherwise lost. In case of insufficient irradiation and therefore a modest pre-heating of the domestic water, the boiler will contribute with the heat necessary to reach the required set point temperature. If the sun and the solar system fulfill their "duty" no integration by the boiler will be necessary, the hot water will be conveyed to the tap, without the need for additional devices, with the mixing of the thermostatic valves. Safety and comfort ANTIFREEZE In the event that the temperature in the boiler drops to 5°C, the burner ignites automatically and the circulator is activated in order to protect the appliance from damage caused by frost. This function is active with the boiler powered by the gas circuit and under electrical voltage. POST-CIRCULATION This function makes it possible to recover all the heat supplied by thermal inertia of the exchanger and transfer it to the heating system, and consequently to the rooms to be heated. This is a timer function (customizable duration) and is active after the burner goes out in heating mode. SLIDING TEMPERATURE OPERATION With the installation of the “external probe” kit it is possible to operate the boiler in sliding temperature. This means that without using the system temperature adjustment keys, the boiler will self-regulate according to the variations in external temperatures. All this translates into energy savings while ensuring maximum comfort for the user. EASY CONTROL The electronic board of DIVACONDENS D PLUS adopts the Opentherm protocol. It allows the integration of other peripheral control units such as, for example, the ROMEO remote timer control. In fact, the Opentherm standard has been specially designed to share the logic and operating algorithms of the boiler with other additional control units. As a digital protocol, it allows total integration between the boiler and the satellite, with full control of the functions from the boiler and similarly from its satellite. Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€425,00
Biasi Gas Boiler Biasi Parva Recover E 24s Condensing Complete With Methane Fume Kit -New Erp
Overview BIASI PARVA RECUPERA E 24S METHANE CONDENSING BOILER - NEW ErP 2015, SEALED CHAMBER COMPLETE WITH FUME EXHAUST KIT: PARVA Recupera E ErP condensing boiler with heat recovery unit. Technical specifications Model:ÿPARVA Recover E 24S Product number:ÿ10312.2045.3 Energy label specifications according to the European ErPÿ directive Class B heating energy efficiency Sanitary energy efficiency Class A Withdrawal profiles: XL Characteristics of heating/sanitary exercises: Thermal input:ÿ25ÿkW Rated useful power: 24.3 kW Nominal load efficiency:ÿ97.2% Efficiency minimum load:ÿ95.1% Energy efficiency stars: (dir 92/42/EEC) **** Min/max heating temperature: 38/85ÿøC Capacity of the expansion vessel: 6 lt Sanitary flow rate t =25øK l/min: 13.9 l/min Degrees of protection for the electrical system:ÿIPX4D Extremely compact dimensions hxwxd: mmÿ803x400x350ÿ; 47.5kg METHANE power supply Features list ErP wall-mounted boilers with recuperator Redeveloping an old thermal systemÿ Biasi has designed the ÿPARVA Recupera NOx EÿandÿPARVA Recupera Eÿboilers to replace traditional boilers in old systems. The PARVA Recupera boilers by Biasi are equipped with a corrosion-resistant aluminum alloy fume recovery unit which makes these boilers particularly solid. The recovery unit is made of aluminium, has a finned coil which determines a large exchange surface and is equipped with a device to ensure that the boiler discharges the condensate correctly. The recuperator is treated with a Teflon coating process to ensure maximum durability over time. Thanks to the large exchange surface, the recuperator allows the recovery of thermal energy which would otherwise be dispersed outside through the hot fumes produced by combustion. PARVA Recover E PARVA Recupera E is the condensing boiler designed for traditional systems and easily adaptable to new floor-based systems using MULTIZONE, a hot water distribution system for heating. PARVA It recovers the traditional boiler in the regulations but it has clearly higher efficiency than the traditional boilers at the same operating temperature. As a condensing boiler, PARVA Recupera allows you to take advantage of the tax deduction according to current legislation. Characteristics: High yields (in compliance with yield directive 92/42 EEC and Legislative Decree 311/06ÿ Primary laminated copper heat exchanger with large double circulation exchange surfaceÿ Aluminum heat recovery unit to exploit the heat of the fumes and transfer it to the waterÿ Sanitary plate heat exchanger in INOXÿ steel High efficiency pump with low energy consumptionÿ retractable control panel, with ergonomic knobs and backlit displayÿ Electronic board for:ÿ - Re-ignition frequency adjustmentÿ - Adjustable primary circuit thermal inertia disposalsÿ - Selection of circulator modeÿ - Circulator anti-seizeÿ - Antifreeze safetyÿ - Chimney sweep functionÿ Integrated automatic by-passÿ Immunity to radio interferenceÿ Sanitary flowstat magneticÿ Absolute heating pressure switchÿ Degrees of protection IPX4Dÿ Possibility of integrating PARVA Recupera E with Biasi solar systems using the optional solar kit. Fiscal detraction As a condensing boiler, PARVA Recupera E allows you to take advantage of the tax deduction according to current legislation.ÿÿ Heat recoveryÿ The heat recovery recovers the heat from the fumes before they are expelled and preheats the water directed to the primary exchanger. The recuperator made of aluminum has a finned coil which determines a large exchange surface and has a device to ensure that the boiler discharges the condensate correctly.ÿÿ Thermoregulation By connecting the external probe (optional) directly to the boiler, you can access the climatic adjustment function. The boiler is equipped with a complete set of curves which can be accessed by entering programming. By simply turning a knob you choose the curve, PARVA recovers and will automatically adapt its operation to the external climatic conditions.ÿÿ High circulation primary heat exchangerÿ It is the element that distinguishes the whole PARVA E Biasi range. It favors the flow of water into the heating system and, thanks to its reduced hydraulic resistance, adapts the boiler to the system, facilitating the transmission of heat to the radiators.ÿ Savings simplicity of use Parva Recupera retains the simplicity of management, programming and regulation of the traditional boiler and imports the savings of the condensing boiler resulting from the recovery of heat from the fumes. The heat recovery unit preheats the system water with the heat released by the fumes, heat which in traditional boilers is dispersed into the environment. This recovery of energy from the fumes, at operating temperatures typical of radiator systems, leads Parva Recupera to have higher yields than traditional boilers. Low complexity, high comfort Parva Recupera boilers, despite the high technical content, are still very simple to use. Theÿcontrol panelÿhas two knobs dedicated to regulating the temperature of the domestic hot water and the heating water, the key to reset the boiler after the lockout status, the new display to view the boiler operating status and make it easier for the user to understand and installer settings . Fault diagnostics allow immediate verification of correct operation. The manometer allows you to check the system pressure while the temperature is shown on the display. Everything is hidden under a door that defines the sober and linear aesthetics of Parva Recupera. Included in delivery Boiler support bracket and paper templateÿ Condensate collection trapÿ Quick instruction to the user.ÿ All ready for Energy Labeling What is it about From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy intensive sectors: construction For placing on the European market, the directive on ÿeco-designÿ(ErP notcome®ÿEnergy Related Productsÿ¯) imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres As in the household appliances sector, the energy labelingÿof products, with a capacity of less than 70 kW, will give consumers simple, recognizable information which allows them to make comparisonsÿon the performance and energy consumption of the product they wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. It's about me too YES, it affects everyone: professionals and end users The information indicated on the energy labelÿwill allow professionals to recommend the right productÿÿindividuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015, the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. Supplier's liability The company that supplies the product on the market is required to equip its system devices with the following documentation: product energy label;ÿ product data sheet;ÿ system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices;ÿ technical data sheet of the system with the parts relating to the products and the system already completed. Responsibilities of Resellersÿ First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device/system to the public. Therefore, even professionals such as plumbers, installers, designers can fall into this category. All bound to ensure that: all appliances and/systems having their respective labels and making sure they are clearly visible;ÿ all appliances and/systems must always be accompanied by the obligatory technical data sheets;ÿ every type of advertising material, technical promotional material which shows energy data and price indications, contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and the production of hot water will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP): The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL There are different labels depending on the type of appliance. Those with efficiency classes A, A+ and A++ certify products with the highest performance. Furthermore, two different classifications are foreseen for domestic heating and for hot water production services, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the end customer can make his choice in the most aware way possible. SYSTEM LABEL In addition to the product label, the system label is also providedÿin cases where a series of appliances combined with each other is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label so as to inform the end user in the best possible way. Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€930,00
Biasi Biasi Gas Boiler Recovers Dgt 24s LPG Condensing Complete With LPG Fume Kit -New Erp
NB: ITEM OUT OF PRODUCTION, IN CASE OF LACK OF PRODUCT WE WILL SHIP THE NEW MODEL MODEL --> BASICA COND 25 ---> https://www.climaconvenienza.it/it/caldaia-biasi-basica-cond-25s-a -condensing-complete-with-gas-exhaust-kit-methane-low-nox-erp-news/ Energy label specifications according to the European ErP directive Class B heating energy efficiency Sanitary energy efficiency Class A Withdrawal profile: XL Characteristics of heating/DHW operation: Heating / domestic hot water nominal heat input kW 25.0 Heating / domestic hot water maximum useful power kW 24.4 Energy efficiency n° ★★★★ NOx class n° 2 Minimum / maximum heating temperature ** °C 40 / 85 Expansion vessel capacity (total / useful) l 8.0 / 4.0 Maximum flow rate (T=25 K) / (T=35 K) l/min 13.9 / 10.0 Degree of protection n° IPX4D Height x Width x Depth mm 803x400x350 CNG or LPG power supply RECOVER DGT Wall mounted condensing boilers Recupera DGT is the condensing boiler designed for traditional systems and easily adaptable to new underfloor systems using Multizone, a hot water distribution device for heating. Recupera DGT maintains the simplicity of management, programming and regulation of the traditional boiler and imports the savings of the condensing boiler deriving from the recovery of heat from the fumes. The heat recovery unit preheats the system water with the heat released by the fumes, heat which in traditional boilers is dispersed into the environment. This recovery of energy from the fumes, at typical operating temperatures of radiator systems, leads Recupera DGT to have higher yields than traditional boilers. Characteristics: High efficiency ( (★★★★ compliant with efficiency dir. 92/42 CEE and Legislative Decree 311/06 • Copper lamellar primary exchanger with large exchange surface and double circulation Aluminum heat recovery unit to exploit the heat of the fumes and transfer it to the water Sanitary plate heat exchanger in stainless steel High efficiency pump with low energy consumption Digital control panel with backlit display Electronic card for: - Restart frequency adjustment - Adjustable primary circuit thermal inertia disposal - Circulator mode selection - Circulator anti-seize - Antifreeze safety - Chimney sweep function Integrated automatic by-pass Immunity to radio interference Magnetic sanitary flow switch Absolute heating pressure switch IPX4D degree of protection Heat recovery The heat recovery recovers the heat from the fumes before they are expelled and preheats the water directed to the primary exchanger. The recuperator is made of aluminium, has a finned coil which determines a large exchange surface and has a device to ensure that the boiler discharges the condensate correctly. Thermoregulation By connecting the external probe (optional) directly to the boiler, climatic regulation can be used. Recupera DGT will adapt the system water temperature to the external climatic conditions, ensuring that the desired room temperature is reached without waste and optimizing consumption. By using the climatic regulation, the regulation efficiency is also raised, giving greater value to your home. Control panel Summer/winter/off selector Heating temperature regulator DHW temperature regulator Digital and analog pressure reading DHW and heating temperature visualization from the display Display of fault diagnostics, block status and fault history Recommended fill display Display annual periodic maintenance expiry All ready for Energy Labeling What is it about? From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy-intensive sectors: construction For placing on the European market, the eco-design directive ( ErP known as « Energy Related Products ») imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres As in the household appliances sector, the energy labeling of products with a capacity of less than 70 kW will give consumers simple, recognizable information which allows for comparisons on the performance and energy consumption of the product you wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. Is it about me too? YES, it affects everyone: professionals and end users The information indicated on the energy label will allow professionals to recommend the right product and individuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015, the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. Supplier responsibility The company that supplies the product on the market is required to equip its devices or systems with the following documentation: product energy label; technical product sheet; system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices; technical data sheet of the system with the parts relating to the product or system already completed. Dealer Responsibility First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device and/or system to the public. Therefore even professionals such as plumbers, installers or planners can fall into this category. Everyone is required to ensure that: all appliances and/or systems have their respective labels and make sure that they are clearly visible; all devices and/or systems are always accompanied by the mandatory technical data sheets; any type of advertising, promotional or technical material showing energy data or price indications contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and hot water production will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP) : The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL Depending on the type of device, there are different labels. Those with efficiency classes A, A+ and A++ certify the products with the highest performance. Furthermore, two different classifications are envisaged for domestic heating and for the hot water production service, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the final customer can make his choice in the most informed way possible. SYSTEM LABEL In addition to the product label, the system label is also provided if a series of matched appliances is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label in order to inform the end user in the best possible way. Warranty All products for sale on our site are new and packed. The guarantee on this item is 24 months from the date of purchase.
€866,00
BERETTA Beretta Ciao At 25 Csi Condensing Boiler Complete With LPG Fume Exhaust Kit - New Erp
BERETTA CIAO AT 25 CSI CONDENSING BOILER COMPLETE WITH LPG FUME EXHAUST KIT - NEW ErP Product code: 20113788 Characteristics: Energy efficiency in heating: B Energy efficiency Sanitary: A Sanitary load profile: XL Nominal heat input: 25 kW Electric Power: 129W Supply voltage/frequency: 230/50 Volt/Hz Electrical protection degree: X5D ip Dimensions HxWxD: 780 x 400 x 338 ; 40 Kg Gas version available: METHANE Warm-up exercise: Maximum pressure and temperatures: 3/90 bar/°C Heating temperature selection range: 40/80 °C Pump: pump head available for the system: 266 m/bar Expansion tank capacity: 8 l Healthcare exercise: Maximum pressure: 6 bars Minimum pressure: 0.15 bar Quantity of hot water with ∆t=25°C: 14.3 l/min Minimum domestic water flow rate: 2 l/min DHW temperature selection range: 37 - 60 °C NB. THE BOILER WILL BE SUPPLIED WITH METHANE, THE ADJUSTMENT NECESSARY FOR LPG OPERATION WILL BE CARRIED OUT FREE OF CHARGE BY THE BERETTA ASSISTANCE CENTER DURING THE FIRST IGNITION. Beretta HELLO AT Hi AT, ideal for replacement in systems with radiators. Ciao AT is the innovative condensing boiler specifically designed by Beretta for traditional high temperature systems (radiators and radiators). The boiler is equipped with a heat recovery unit on the fumes and combustion in a sealed chamber; this allows to obtain very high performance in terms of efficiency and therefore a significant energy saving. High performance and low consumption In the Ciao AT boiler, the water in the primary circuit passes through an additional exchanger, which allows you to recover energy that would otherwise be wasted. This process makes it possible to recover latent heat and therefore to further increase the performance of the boiler. The energy saving offered by a boiler is greater the higher its efficiency: Ciao AT therefore allows you to reduce gas consumption compared to a boiler without an additional exchanger. Management: The electronic panel is the interface for managing the boiler. Simple and intuitive, it allows you to adjust the boiler parameters and activate the numerous functions. The liquid crystal display provides information on the status of the device and the diagnostic codes. By turning the knobs, the heating water and domestic hot water temperature can be set easily and intuitively. The panel integrates the Sistema Clima Amico function. The Ciao AT technology makes use of the condensing exchanger which recovers the latent heat of the fumes, the same principle used by condensing boilers. The exchanger, located at the top left, is connected directly to the fan which pushes the fumes inside it, before they are definitively expelled. The difference in the temperature of the fumes between the ~140°C inlet and the ~65°C outlet of the condensing exchanger is indicative of the amount of heat recovered from them. The return from the system first passes through the condensing exchanger which recovers the heat from the fumes, and then passes through the primary exchanger, where it receives the remaining heat in order to reach the required flow temperature. The water then recovers part of the heat from the fumes, which would otherwise be expelled into the atmosphere, thus giving rise to less waste and consequently greater savings for the user. Outdoor installation: Ciao AT is designed to also be installed outdoors in partially protected places thanks to the dedicated accessories (bottom cover kit and top cover kit) and board anti-freeze protection down to 0 °C. In colder temperatures it is possible to extend the protection down to -10 °C using the special antifreeze heater kit with which the lower cover is required. Up to 17 meters of Ø 60 ducting with the Ciao AT boiler: With Ciao AT it is possible to comfortably duct even the most "difficult" flues thanks to the approval for Ø 60mm flue systems which is added to the traditional Ø 80 mm ducting flue system. The main 60mm flue ducts are available in the Beretta price list catalogue, while the boiler manuals provide indications of the maximum length, which differ according to the boiler power. TECHNICAL FEATURES: Specific for systems with radiators and radiators (at high temperature) Condensing post exchanger in aluminum alloy Possibility of outdoor installation with antifreeze heater kit (optional) IPX5D electrical protection degree Environmental Self-Regulation System (SARA) Low consumption circulator 6 m (EEI≤0.20) Hydraulic connections cover (optional) Condensate collection neutralizer drawer kit (optional) Template, hydraulic fittings, gas and sanitary taps (optional) For gas conversion, contact authorized Beretta Technical Assistance Centres Product Guarantee All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€711,00
FER Offer - Fer Fersystem 10 Tech 10 Sealed Chamber Natural Gas Boiler With Split Fume Kit
OFFER - Sealed Chamber Fer FERSYSTEM 10 TECH 10 Natural Gas Boiler with flue kit Max heat capacity kW 10.2 (Q) Max hot thermal power (80/60°C) kW 10.0 (P) Emission class nOX - 5 (NOx) Maximum operating pressure at heatp bar 3 (PMS) Maximum heating temperature° C 95 (tmáx) Expansion vessel capacity 7 l IP X5D degree of protection Supply voltage V/Hz 230V/50Hz Electric power consumption W 110 Dimensions HxWxD mm 700x320x300 FERSYSTEM TECH 10A It is a premixed condensing heat generator for heating and domestic hot water production (with optional external boiler) with very high efficiency and very low emissions, running on natural gas or LPG and equipped with a microprocessor. The appliance has a sealed chamber and is suitable for installation indoors or outdoors in a partially protected place (according to EN 297/A6) with temperatures down to -5°C (-15°C with optional siphon antifreeze kit). The boiler is designed for connection to an external tank for domestic hot water (optional). In this manual all the functions relating to the production of domestic hot water are only active with the optional domestic hot water tank Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€370,00
Riello Riello Start Ar 29 Kis Low Nox Condensing Boiler Cod. 20151818 Complete With Methane Fume Exhaust Kit - New Erp
WALL-MOUNTED CONDENSING BOILER COD.20151818 RIELLO START AR 29 KIS LOW NOX FOR HEATING AND HOT WATER FUME KIT INCLUDED METHANE KASKO INSURANCE SHIPPING ON PLATFORM ErP technical data Seasonal space heating energy efficiency class B Water heating energy efficiency class A Declared load profile XL Heating technical data Nominal heat input (Hi) kW 28 Nominal heat output (80-60°C) 26.82 Warm-up exercise Maximum pressure bar 3 Maximum temperature 90 °C Membrane expansion vessel l 8 Sanitary technical data Nominal heat input (Hi) kW 28.00 Profit return 30% (30th return) % 100.6 Supply voltage V - Hz 230-50 IP X5D degree of protection NOx class 6 Dimensions WxDxH 400x332x780 mm; 37 kgs START AR Start AR is the condensing boiler specifically designed to operate with high temperatures and therefore with radiator systems. It is available in power ratings of 25 and 29 kW with low NOx emissions <56 mg/kWh. – Cooled burner – Low consumption circulator (IEE≤0.20) – Climatic regulation managed directly by the boiler control unit – Assembly crossbar, power supply cable supplied – Hydraulic connections available as an accessory – Degree of electrical protection IP X5D Product Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€738,00