Wall Boilers
Savio Savio Evodens E 25s* Condensing Gas Boiler Complete With Kit For Methane Fume Exhaust - New Erp
Overview SAVIO evoDENS E 25S* CONDENSING BOILER COMPLETE WITH KIT FOR LPG METHANE FUME EXHAUST - NEW ErP Technical specifications Model:ÿevoDENS Product codeÿLPG: 103021010300 Product codeÿMETHANE: 103121017300 Characteristics of heating/sanitary exercises: Heating/DHW nominal heat inputÿ20.0 / 25.0 Minimum heating/DHW heat inputÿ6.0 Yield name 60ø/80øC % 97.4 Yield min. 60ø/80øC % 97.4 Efficiency 30% at 30°C: 101.5 Energy efficiencynøÿ Minimum / maximum heating temperature**øC 25 / 85 Minimum / maximum heating pressurebar 0.3 / 3.0 Capacity of the expansion vessel (total / useful) l 7.0 / 3.5 Minimum / maximum sanitary temperatureøC 35 / 55 Sanitary minimum / maximum pressurebarÿ0.3 / 10.0 Maximum flow rate (T=25 K) / (T=35 K) l/minÿ15.9 / 11.4 Voltage / Power at nominal heat input V ~ÿ230 ~ / 98 Power at minimum thermal capacity W 9 Power at rest (stand-by) W 5 Degrees of protection nø IPX5D Dimensions HxWxD:ÿ700x400x290 mm; 31.5 kgs Boiler water content 2.0 l Main features evoDENS The new Savidi range of high efficiency wall mounted boilers dedicated to residential buildings. A complete range of powers, 24, 28 and 32 kW, for heating and the production of domestic hot water, inÿextremely compact dimensionsÿ (700 x 400 x 325 mm) makes Evodens a product suitable for different comfort needs.ÿEvodensÿe endowed with an aesthetic innovativeÿand a newÿimmediate and simpleÿto use interface. New functions make ÿEvodens an integral part of a system and facilitate its installation. Exchangers: Primary heat exchanger in copper, high circulation lamellar. Sanitary heat exchanger in stainless steel plates digital control panel:ÿInnovative digital control panel with graphical interface and buttons Ecodesign Directive: from 2015 on new condensing boilers In fact, after very long negotiations, the ÿEcodesign regulationÿ was approved, which introduces a new energy labeling on minimum efficiency standards for boilers.ÿIn particular, an energy classification from A+ to G is envisaged for space heating appliances and from A to G for appliances for the production of domestic hot water. ÿHence the obligation to installÿonly condensing boilers, heat generators capable of recovering a large part of the latent heat contained in the fumes which, otherwise, would be dispersed in the chimneyÿas occurs in traditional boilers. The recovered heat is transferred to the heating system, making it possible to achieve a yield of 106% with 92% of the traditional boiler and 84/85% of an oldÿÿtraditional generator.ÿThe installation obligation concerns manufacturers of boilers which will no longer be able to place on the market non-condensing starting from 26 September 2015. This means that starting from this date, anyone who wants to install a boiler in their own home will have to install only condensing models. Only one particular type of non-condensing boiler will continue to be produced which is technically called open room? to be installedÿ when it is not possible to replace an old boiler with a condensing boilerÿdue to problems related to the collective flueÿof some multi-family buildings. Products for heating water and the environment represent around 30% of the world's energy consumption in Europe.ÿ Designing eco-friendly products and promoting high performance technologies to end users in 2020 will lead to: An annual energy saving equivalent to 56 million tons of oil, quantifiable to the savings obtained if the water and environmental heating systems of two large nations like Italy were deactivated. As of 26 September 2015, the ErP regulation and ÿenergy labelingÿwill be applied in Europe to water and space heating products (boilers, heat pumps, micro-CHP devices, water heaters, and hot water storage tanks) u. How to read energy labels There are different labels, based on the type and function of the product (only room water heating of both, and in this case the label must bear both classifications). In addition to the energy class, the label provides other information that could be useful for understanding which product has the least environmental impact (for example power and consumption in different climatic zones, noise levels, etc.). It is possible to increase the energy efficiency of hot water production and space heating by connecting several products and accessories in one system. In this case it is necessary to prepare a system label in addition to that relating to the single product Warranty All products for sale on our site are new and packed. The guarantee on this article is 24 months from the date of purchase.
€1.073,00
HERMANN SAUNIER DUVAL Gas Boiler Saunier Duval Micra 4 Condensing 25 Kw Methane Complete Kit For Smoke Exhaust - New Erp
IN THE ABSENCE OF THE PRODUCT, THE NEXT MODEL "MICRA 4 CONDENSING 25 MIGO" WILL BE PROPOSED WITH A DIFFERENT PRICE SAUNIER DUVAL MICRA 4 CONDENSING 25 kW METHANE GAS BOILER COMPLETE WITH FUME EXHAUST KIT - NEW ERP Model ErP efficiency class in heating/DHW: A Sanitary load profile: XL Type: Heating and domestic hot water Combustion chamber: sealed Domestic hot water production technology: Aquaspeed® Heating Nominal power P min/max heating 80/60 °C: kW 5.4/19.1 Partial load efficiency 30% 40/30 °C %: 108.5 Sanitary Rated power min/max (60 °C): kW 5/25.2 Specific flow rate (∆T=25 K): l/min 14 Continuous flow rate (∆T=30 K): l/min 12 Min/max DHW temperature: 35/60 °C Electrical characteristics Total absorbed electric power: W 66 Supply voltage/frequency: V/Hz 230/50 Dimensions: Dimensions (h x w x d): 700 x 390 x 280 mm CNG code (G20) - 10015675 METHANE version MICRA 4 CONDENSING The Micra 4 Condensing condensing boilers, ecological and performing, meet the highest standards in terms of efficiency and comfort, thanks to the exclusive Aquaspeed® technology for the production of domestic hot water. The range includes two combined models of 25 and 30 kW and 3 heating only models of 12, 26 and 30 kW. Characteristics Energy classification 4 stars **** (92/42/EEC) with yields up to 109.2%; Sanitary comfort 3 stars ***(EN 13203-1), thanks to the Aquaspeed® system which guarantees the immediate delivery of domestic hot water at the desired temperature and the sanitary stainless steel plate exchanger with pre-heating function (Kombi models) The control panel on the boiler, with backlit liquid crystal display and negative contrast, makes adjusting Micra 4 Condensing extremely easy and immediate: with a few simple gestures it is possible to adjust the temperatures of the heating and domestic hot water, for any need . Solar Easy: all models in the Micra 4 Condensing range can be combined with solar systems, thanks to special kits. The small dimensions make all Micra 4 Condensing models perfect both for new systems and for replacement in existing systems. Continuous domestic hot water production (DHW) up to 18 l/min (Kombi models) • Low NOx emissions - class 5 (EN 483) Total premix burner and primary exchanger in anti-corrosion Aluminium-Silicon alloy High efficiency and modulating circulator Heating system antifreeze function Product Guarantee All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.209,00
Biasi Biasi Gas Boiler Renew Cond Plus 25 S Methane Complete With Fume Exhaust Kit
Technical features Model: rinNOVA COND PLUS E 25S Energy label specifications according to the European ErP directive Class A heating energy efficiency Sanitary energy efficiency Class A Withdrawal profile: XL Characteristics of heating/DHW operation: Heating / DHW nominal heat input kW 21.0 / 26.0 Heating / DHW maximum useful output 60°/80°C * 20.3 / 15.1 Energy yield n° **** NOx class 6 Expansion vessel capacity 7.0 l (total) Maximum range (ΔT=25K) / (ΔT=35K) 14.5 / 10.3 Degree of protection IPX5D Dimensions HxWxD 700x400x290; 33 kgs General characteristics renew COND PLUS RinNova Cond Plus is the new BIASI range of wall-mounted condensing boilers: excellent performance thanks to the new heat exchanger and ease of use thanks to the digital control panel with display. Available in versions for heating and domestic hot water production and for heating only RinNova Cond Plus presents a complete range of powers, 20 and 30 kW combi models and 16 KW SV models, in the same extremely compact dimensions (700 x 400 x 290 mm) . RinNova Cond Plus has its strong point in the innovative heat exchanger designed to provide high yields that last over time digital control panel, designed to communicate with the user in an easy and comfortable way. Like the entire BIASI condensing range, RinNova Cond Plus allows you to obtain maximum savings from climatic thermoregulation, based on the system in which the boiler is installed Characteristics: High yields (★★★★ compliant with yield directive 92/42 EEC and Legislative Decree 311/06) Sanitary comfort (★★★ EN 13203) Primary condensing exchanger in stainless steel with steel lining to offer maximum resistance to corrosion Total premix burner, built in stainless steel (Class NOx 6) Modulation 1:5 CNG and also LPG Sanitary plate heat exchanger in stainless steel 7 liter expansion vessel High efficiency pump with low energy consumption Maximum power adjustable according to the system • IPX5D degree of protection Can be installed in a partially protected place Integration with BIASI solar systems, using a solar kit Digital control panel with backlit display Analog pressure reading Arrangement for remote control and external probe. Control panel Summer/winter/off selector Heating temperature regulator DHW temperature regulator Analog pressure reading DHW and heating temperature visualization from the display Display of fault diagnostics, block status and fault history Recommended fill display and fill guide View annual maintenance expiry The display operates according to the modes: 1. INFO. Info mode displays the following information: External temperature (in case of external probe connected) K value (in case of external probe connected) Sanitary / heating temperatures chosen by the user Smoke temperatures. 2. PROGRAMMING. The programming mode allows you to change the boiler parameters. - In chimney sweep mode it is possible to test the boiler and adjust the gas valve. Thermoregulation By connecting the external probe and the remote control (optional) directly to the boiler, climatic regulation can be used. RinNova Cond Plus will adapt the system water temperature to the external climatic conditions, ensuring that the desired room temperature is reached without waste and optimizing consumption. By using the climatic regulation, the regulation efficiency is also raised, giving greater value to your home. High regulation single coil primary heat exchanger Biasi introduces on the market the new stainless steel heat exchanger for condensing boilers: Round. Round is a compact monothermal heat exchanger based on a stainless steel coil with an oval section. The heat exchanger consists of a combustion chamber, condensing area and an insulated metal disc protected with silicone ceramic fiber which separates the two areas. By using a single strip of stainless steel to produce the coil, including inlet/outlet fittings, the following benefits are achieved: Accumulation of dirt and debris is avoided The water flow is uniformly distributed and guarantees a homogeneous heat exchange The water flow is constant for a longer life of the product Reduction of pressure drops with optimized circuit. The ease of cleaning and the robustness of this exchanger are one of the main strengths of the product since it can be used on new systems but also on old systems in the event of renovations. Round integrates the round flow function in which the water produces a centrifugal cleaning effect on the internal walls of the single coil. The absence of circuits in parallel guarantees an easy "washing" operation of the exchanger and the elimination of any air present in the system circuit. All ready for Energy Labeling What is it about? From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy-intensive sectors: construction For placing on the European market, the eco-design directive ( ErP known as « Energy Related Products ») imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres As in the household appliances sector, the energy labeling of products with a capacity of less than 70 kW will give consumers simple, recognizable information which allows for comparisons on the performance and energy consumption of the product you wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. Is it about me too? YES, it affects everyone: professionals and end users The information indicated on the energy label will allow professionals to recommend the right product and individuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015 , the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. Supplier responsibility The company that supplies the product on the market is required to equip its devices or systems with the following documentation: product energy label; technical product sheet; system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices; technical data sheet of the system with the parts relating to the product or system already completed. Dealer Responsibility First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device and/or system to the public. Therefore even professionals such as plumbers, installers or planners can fall into this category. Everyone is required to ensure that: all appliances and/or systems have their respective labels and make sure that they are clearly visible; all devices and/or systems are always accompanied by the mandatory technical data sheets; any type of advertising, promotional or technical material showing energy data or price indications contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and hot water production will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP) : The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL Depending on the type of device, there are different labels. Those with efficiency classes A, A+ and A++ certify the products with the highest performance. Furthermore, two different classifications are envisaged for domestic heating and for the hot water production service, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the final customer can make his choice in the most informed way possible. SYSTEM LABEL In addition to the product label, the system label is also provided if a series of matched appliances is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label in order to inform the end user in the best possible way. Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€847,00
Riello Riello Start In Condens 29 Kis Methane Condensing Boiler Complete With Smoke Kit - New Erp
RIELLO START IN CONDENS 29 KIS METHANE CONDENSING COMPLETE WITH FUME KIT + BUILT-IN UNIT - NEW ErP Energy label specifications according to the European ErP directive Class A heating energy efficiency Sanitary energy efficiency profile XL Class A Characteristics of heating/DHW operation: Heating nominal heat input: 25 kW Sanitary nominal heat input: 29 kW Energy efficiency (92/42/EEC) **** Useful efficiency Pn (50°/30°): 104.9% Profit return 30% (47th return): 108.4% Sealed chamber, forced draught Quantity of hot water with Δt 25°C: 16.6 l/min Dimensions (hxwxd) mm 792 x 405 x 248 ; 32 kgs Electrical protection degree: IP X5D NOx class: 5 It can be installed flush-mounted using the special built-in unit Power supply: METHANE General characteristics START IN CONDENS Yield **** Low polluting emissions Aluminum condenser, with premix burner Recessed Start IN Condens is the new Riello condensing wall-mounted proposal for small and medium-sized domestic users. The new compact aluminum condensing exchanger guarantees efficiency and reduction of polluting emissions. It can be installed flush-mounted using the special kit. It is available in version 25 (with 25 kW of DHW power and 20 kW in heating) and 29 (with 29 kW of DHW power and 25 kW in heating). Characteristics: Low consumption circulator (IEE≤0.20) "Winter with Pre-heating" function: allows the DHW exchanger to be kept at temperature, reducing waiting times during withdrawal (can be activated by the user) Remote control panel in combination with the external probe (optional) Product Guarantee All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.179,00
Junkers Bosch Junkers Bosch CERAPUR SMART ZWB 28-3 CE condensing boiler complete with low NOx flue gas exhaust kit Methane
Junkers Bosch CERAPUR SMART 28-3 CE condensing boiler complete with low NOx methane fume exhaust kit - NEW Heating energy class A Sanitary energy class A XL load profile Maximum nominal thermal power 21.8 kW Max DHW nominal heat input 27.4 kW Seasonal space heating energy efficiency 93% NOx class 6 Dimensions WxLxH 350x400x850 CERAPUR SMART Cerapursmart condensing boiler : compact comfort, excellent performance Ideal for replacing the old boiler due to the simplicity of installation Robust and reliable boiler Possibility of remote connection of the boiler The boiler can be installed in any context Advantages Ideal for replacement Ideal for replacing old boilers thanks to the distance of the water connections from the wall equal to 18 cm. This allows for extremely easy installation Robustness and reliability This condensing boiler offers strong robustness and great reliability thanks to the primary exchanger in Al-Si WB6 aluminum alloy Remotely controllable Boiler connectivity possible via the EasyControl CT 200 intelligent thermostat or via the MB LAN2 module (accessory) which can be combined with CR…, CW…(1) thermoregulators Suitable for any context Simple installation of the boiler in any context thanks to the C6 approval which allows the use of any intake/exhaust system
€1.420,00
BERETTA Beretta Mynute Rain Green E 30 Csi Condensing Boiler Complete With Fume Exhaust Kit -New Erp
Technical features Class A heating energy efficiency Sanitary energy efficiency profile XL Class A Heating nominal heat input: 25 kW Sanitary nominal heat input: 30 kW Classification European Directive EEC 92/42: **** Quantity of hot water with Δt=25°C: 17 l/min IPX5D electrical protection degree Nox class: 5 Power supply: methane Characteristics The new Beretta boiler is made up of a new type of front access exchanger, made up of a single seamless aluminum tube, thus making the thermal resistance of aluminum higher than steel, allowing for uniform temperature distribution. In addition, this accurate serial circuit allows a large part to be prepared for the passage of water, reducing pressure drops and preventing the deposit of impurities, thus allowing excellent performance over time. In addition, with MYNUTE, it is equipped with a 50mm smoke outlet approval. For periodic cleaning, the boiler has an accurate system of guides which facilitates the assembly and disassembly of the drawer. Finally, for the management of the device there are two knobs, one for regulating the temperature and the other for domestic hot water, and a display that shows all the functions which is very simple to use. For filling the system, it has a filling cock and a visible filling hydrometer. FLEX modulating circulators: The MYNUTE RAIN boiler works with an electric motor of the circulator with an Energy Efficiency of 0.20, also having such a significant energy savings compared to traditional boilers. It is also possible to modify, if greater heating is required, the head of the circulator with a larger one (FLEX). Dimensions: (HxWxD): 797x553x274mm
€1.300,00
CHAFFOTEAUX Chaffoteaux Mira Advance 30 Kw LPG Gas Boiler Complete With Smoke Exhaust Kit
Technical features Product code: 3310616 Energy label specifications according to the European ErP directive Class A heating energy efficiency Sanitary energy efficiency Class A Withdrawal profile: XL Characteristics of heating/DHW operation: Heating nominal heat input max/min (Hi): 28/3.0 kW DHW nominal heat input max/min (Hi): 30.0/3.5 kW Performance Stars **** Expansion tank capacity 8 l Instantaneous quantity of hot water (∆T=25 K): l/min 17.2 Domestic water pressure max/min bar 7.0/0.2 Electrical characteristics Supply voltage/frequency: V/Hz 230/50 IP X5D degree of protection Dimensions Weight: 32.3kg General characteristics AIM ADVANCE Mira Advance is the condensing boiler born for the future with a powerful soul, Spin Tech, the new exchanger with a completely renewed design that offers high performance, to improve domestic comfort and adapt to every need. Maximum Performance: New single coil primary heat exchanger in stainless steel. Passage sections increased by 142% compared to the previous version. 1 m more head. Seasonal yield at 94%. Class A+ reachable with thermoregulation. Maximum Comfort Modulation ratio 1:10. Electronic combustion control E-Burning System. SRA function. Gas transformation from the technical menu without the need for a kit. Ready for Chaffolink connectivity. Ease of Installation Installation in partially protected places. Smoke outlets 80, 60, 50 mm. Intuitive electrical connections. Energy saving and respect for the environment Up to 25% energy savings in combination with Expert Control and the SRA function. Up to 35% energy savings by combining Expert Control, the SRA function, the external probe and the radiant floor. All ready for Energy Labeling What is it about? From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy-intensive sectors: construction For placing on the European market, the eco-design directive ( ErP known as « Energy Related Products ») imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres As in the household appliances sector, the energy labeling of products with a capacity of less than 70 kW will give consumers simple, recognizable information which allows for comparisons on the performance and energy consumption of the product you wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. Is it about me too? YES, it affects everyone: professionals and end users The information indicated on the energy label will allow professionals to recommend the right product and individuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015 , the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. Supplier responsibility The company that supplies the product on the market is required to equip its devices or systems with the following documentation: product energy label; technical product sheet; system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices; technical data sheet of the system with the parts relating to the product or system already completed. Dealer Responsibility First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device and/or system to the public. Therefore even professionals such as plumbers, installers or planners can fall into this category. Everyone is required to ensure that: all appliances and/or systems have their respective labels and make sure that they are clearly visible; all devices and/or systems are always accompanied by the mandatory technical data sheets; any type of advertising, promotional or technical material showing energy data or price indications contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and hot water production will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP) : The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL Depending on the type of device, there are different labels. Those with efficiency classes A, A+ and A++ certify the products with the highest performance. Furthermore, two different classifications are envisaged for domestic heating and for the hot water production service, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the final customer can make his choice in the most informed way possible. SYSTEM LABEL In addition to the product label, the system label is also provided if a series of matched appliances is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label in order to inform the end user in the best possible way. Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.124,00
Biasi Biasi Gas Boiler Renew Cond XE 35s Condensing Complete With Methane Fume Exhaust Kit -New Erp
Overview BIASI rinNOVA COND XE 35S CONDENSING BOILER COMPLETE WITH LPG METHANE FUME EXHAUST KIT - NEW ErP Technical specifications Model: rinNOVA COND XE 35S Energy label specifications according to the European ErPÿ directive Class A heating energy efficiency Sanitary energy efficiency Class A Withdrawal profiles: XXL Characteristics of heating/sanitary exercises: Thermal powerÿuseful sanitaryÿ(80/60ø C)ÿkW (kcal/h)ÿ33.4 (28,724) Heating capacityÿuseful heatingÿ(80/60ø C)ÿkW (kcal/h)ÿ32.1 (27,606) Heat input(*)ÿnominalÿkW (kcal/h)ÿ34.0 (29,240) Heat inputÿminimumÿkW (kcal/h)ÿ8.5 (7,309) Sanitary flowÿt =25øKÿl/minÿ21.6 Dimensions (HxWxD) 700x400x290 mm Main features renew COND Xÿ RinNova Cond X The BIASI premixed condensing range completes: perfectÿfor underfloor systems for radiator systems, the compact condensing boiler that ensures high yields, low consumption and respect for the environment. Availableÿfor heating and domestic hot water production, in powers of 25 and 35 kW and forÿheating only in powers of 16, 25 and 35 kW. Characteristics: High yields (in compliance with yield directive 92/42 EEC and Legislative Decree 311/06) Sanitary comfortÿÿ(EN 13203) Primary and condensing exchanger in stainless steel with plastic linings to offer maximum resistance to corrosion Total premix burner, built in stainless steel (class NOx 5) Sanitary plate heat exchanger in stainless steel High efficiency pump with low energy consumption Maximum power adjustable according to the needs of the system Degrees of protection IPX5D Installability in a partially protected place Integration with BIASI solar systems using a solar kit digital control panel with backlit display Digital pressure reading by pressure transducer Arrangement for external probe remote control Four-controllers Summer/winter/off selector Heating temperature regulator DHW temperature regulator Digital pressure reading DHW and heating temperature visualization from display Display of fault diagnostics, fault history block status View recommended fill View annual maintenance expiry The display operates according to the modes: 1. INFO. Inf mode displays the following information: External temperature (in case of connected external probe) K value (in case of connected external probe) Sanitary / heating temperatures chosen by the user Smoke temperatures. 2. PROGRAMMING. The programming mode allows you to modify the boiler parameters. In chimney sweep mode it is possible to test the boiler and make adjustments to the gas valve. RinNova Cond XE: Adjustable maximum power The adjustable maximum useful heating power parameter meets the needs of modern construction without compromising comfort required in the production of domestic hot water. In fact, this function makes it possible to limit the maximum useful power in heating, independently of the useful domestic power. Hot water even with the sun RinNova Cond XE for heating and hot water production: the sanitary exchangerÿin stainless steel combined with the electronic management and low inertia of the primary exchangerÿdetermine excellent performance even in the production of domestic hot water.ÿFor the production of domestic hot water RinNova Cond XE can be combined with BIASI solar systems using specific solar kit (optional). The boiler cuts in only when necessary, making the most of solar energy and guaranteeing the comfort required by the user. Included in delivery: Boiler support bracket and paper template Boiler power cable Condensate collection siphon Quick instruction to the user. All ready for Energy Labeling What is it about From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy intensive sectors: construction For placing on the European market, the directive on ÿeco-designÿ(ErP notcome®ÿEnergy Related Productsÿ¯) imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres or As in the household appliances sector, the energy labelingÿof products, with a capacity of less than 70 kW, will give consumers simple, recognizable information which allows them to make comparisonsÿon the performance and energy consumption of the product they wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. It's about me tooÿ YES, it affects everyone: professionals and end users The information indicated on the energy labelÿwill allow professionals to recommend the right productÿÿindividuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015, the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. Supplier's responsibility The company that supplies the product on the market is required to equip its system devices with the following documentation: product energy label;ÿ product data sheet;ÿ system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices;ÿ technical data sheet of the system with the parts relating to the products and the system already completed. Responsibilities of Resellersÿ First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device/system to the public. Therefore, even professionals such as plumbers, installers, designers can fall into this category. All bound to ensure that: all appliances and/systems having their respective labels and making sure they are clearly visible;ÿ all appliances and/systems must always be accompanied by the obligatory technical data sheets;ÿ every type of advertising material, technical promotional material which shows energy data and price indications, contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and the production of hot water will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP): The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL There are different labels depending on the type of appliance. Those with efficiency classes A, A+ and A++ certify products with the highest performance. Furthermore, two different classifications are foreseen for domestic heating and for hot water production services, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the end customer can make his choice in the most aware way possible. SYSTEM LABEL In addition to the product label, the system label is also providedÿin cases where a series of appliances combined with each other is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label so as to inform the end user in the best possible way. Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€997,00
Riello Riello Start Aqua Condens 25 Bis Methane Condensing Boiler Complete With Smoke Kit - New Erp
RIELLO START AQUA CONDENS 25 BIS METHANE CONDENSING BOILER COMPLETE WITH SMOKE KIT - NEW Erp: Start Aqua Condens is a wall-mounted boiler with a 45-litre stainless steel boiler. Technical Features Heating energy efficiency Class A Energy efficiency of sanitary equipment XL profile Class A Heating/sanitary operation features: Nominal heating heat output: 25 kW Nominal heating power (80ø/60ø):ÿ24.50 kW Nominal heating power (50ø/30ø):ÿ26.25 kW Nominal heat output for domestic hot water: 25 kW Nominal heat output for sanitary use: ÿ25 kW Energy efficiency (92/42/EEC) ÿ**** Useful efficiency Pn (50ø/30ø): ÿ105% - 108% Profitability 30% (47ø return): 107.1% Airtight chamber, forced draft Amount of hot water with t 30øC: 141 *** Amount of water drawn (litres) in 10' with ǽÓ??ÿT = 30øC Dimensions (hxwxd) mm 1005 x 450 x 600; 66 kg Electrical protection degree: IP X5D NOx class: 5 PRODUCT CODE: 20100125 Power supply: METHANE General Features START AQUA CONDENS INTERNAL Combined model with 45 litre stainless steel tank. Start Aqua Condens is a wall-mounted boiler with a 45 litre stainless steel boiler. The Riello exchanger made entirely of aluminium guarantees efficiency and durability, high prevalence and reduction of polluting emissions. It is available with a power of 25 kW. Certification or Range Rated that allows the nominal power of the boiler to be adjusted to the actual thermal needs of the system. Three-speed circulator. Standard thermoregulation on the board in combination with the external probe (optional). Assembly template, hydraulic fittings, power cable included. Standard methane operation with the possibility of conversion to LPG (G31) (accessory), this modification must be carried out by the installer of the technical assistance service. ErP: Energy related Products The new European regulations for heat generators ErP is the acronym for “ Energy related Products ” (energy-related products) and is the abbreviation that identifies the European ErP Directive 2009/125/CE, defined by the EEC with the aim of reducing the energy consumption of products through eco-compatible design (“eco-design”). The scope of this European Directive is extremely broad as it has so far affected products such as light bulbs, air conditioners, washing machines, fans, etc. Following the publication in September 2013 of a series of implementing regulations, from 26 September 2015 it will also apply to heating and domestic hot water production products. Also from the same date, other regulations that will implement the energy labeling of the same product families will become effective. The transitional period between the publication of the regulations and their activation throughout the European Community was necessary to allow the full reception of the contents by companies and market players. Energy labelling of heating and domestic hot water products The regulations issued require that all products intended for heating and/or the production of sanitary water, with a nominal thermal power lower than or equal to 70 kW, be placed on the market with an energy label that highlights their efficiency class. Note: the regulation requires the presence of the energy label for the release of the product from factories to the market. All products previously released, for example present in distribution warehouses, can be regularly marketed even if they do not have an energy label. Different energy labels have been provided based on the use of the generator used: for heating from A++ to G; for the production of sanitary water from A to G. A new way to guide the consumer The purpose of energy labels is to allow the consumer to easily identify the efficiency level of a product and to be able to make a homogeneous comparison between products that use different technologies. For products whose transformation efficiency is influenced by external conditions, such as heat pump products, as has been done for air conditioners, the efficiency data is reported for the average climate range. In addition to product energy labels, European regulations have also provided for the creation of a system label in the case of a system in which several devices, components and controls operate. This labeling, thanks to the combinations of data from the different elements used in the system, will allow the creation of systems capable of reaching efficiency levels even higher than those of individual generators. The European regulation requires that the system label must be made available by those who supply and/or operate the system (sellers-installers); however, this option is also granted to manufacturers. Product Warranty All products for sale on our site are new and packaged. The warranty on this item is 24 months from the date of purchase.
€1.372,00
Riello Riello Start Ar 29 Kis Low Nox Condensing Boiler Cod. 20151818 Complete With Methane Fume Exhaust Kit - New Erp
WALL-MOUNTED CONDENSING BOILER COD.20151818 RIELLO START AR 29 KIS LOW NOX FOR HEATING AND HOT WATER FUME KIT INCLUDED METHANE KASKO INSURANCE SHIPPING ON PLATFORM ErP technical data Seasonal space heating energy efficiency class B Water heating energy efficiency class A Declared load profile XL Heating technical data Nominal heat input (Hi) kW 28 Nominal heat output (80-60°C) 26.82 Warm-up exercise Maximum pressure bar 3 Maximum temperature 90 °C Membrane expansion vessel l 8 Sanitary technical data Nominal heat input (Hi) kW 28.00 Profit return 30% (30th return) % 100.6 Supply voltage V - Hz 230-50 IP X5D degree of protection NOx class 6 Dimensions WxDxH 400x332x780 mm; 37 kgs START AR Start AR is the condensing boiler specifically designed to operate with high temperatures and therefore with radiator systems. It is available in power ratings of 25 and 29 kW with low NOx emissions <56 mg/kWh. – Cooled burner – Low consumption circulator (IEE≤0.20) – Climatic regulation managed directly by the boiler control unit – Assembly crossbar, power supply cable supplied – Hydraulic connections available as an accessory – Degree of electrical protection IP X5D Product Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€738,00
Riello Riello Residence Condens 32 Kis LPG Condensing Boiler Complete With Smoke Kit - New Erp
RIELLO RESIDENCE CONDENS 32 KIS LPG CONDENSING BOILER COMPLETE WITH FUME KIT - NEW ErP Technical features Product code: 20096588 Energy label specifications according to the European ErP directive Class A heating energy efficiency Sanitary energy efficiency profile XL Class A Characteristics of heating/DHW operation: Heating nominal heat input: 30 kW Sanitary nominal heat input: 32 kW Energy efficiency (92/42/EEC) **** Useful efficiency Pn (50°/30°): 104.7% Profit return 30% (47th return): 109.8% Sealed chamber, forced draught Quantity of hot water with Δt 25°C: 18.3 l/min Dimensions (hxlxp) mm 845 x 450 x 358 ; 42 kgs Electrical protection degree: IP X5D NOx class: 5 Power supply: METHANE RESIDENCE CONDENS Yield **** Low polluting emissions Aluminum condenser, with premix burner Heating only models and combined models Residence Condens is the Riello wall-mounted condensing boiler for medium-sized users. The new primary heat exchanger completely made of aluminum with front access to the combustion chamber ensures better efficiency and durability. It is available with powers from 20 to 32 kW. Characteristics: Modulation ratio 1:8 which allows the boiler to respond to all heat requests Self-modulating circulator, low consumption (IEE≤0.20) "Winter with Pre-heating" function: allows the DHW exchanger to be kept at the right temperature, reducing waiting times during withdrawal (instantaneous combined models only) Standard thermoregulation on the card in combination with the external probe (optional) Assembly template, hydraulic fittings, power supply cable supplied Product Guarantee All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.289,00
Riello Riello Family Condens 3.5 Kis LPG Condensing Boiler Complete With Smoke Kit - New Erp
Overview RIELLO FAMILY CONDENS 3.5 KIS LPG CONDENSING BOILER COMPLETE WITH FUME KIT - NEW ErP 2015: Family Condens is a technologically advanced wall-mounted boiler that combines the best comfort, energy savings and respect for the environment. Technical specifications Product code:ÿ20021506ÿ Energy label specifications according to the European ErP directive Class A heating energy efficiency Sanitaryware energy efficiencyprofilXL Class A Characteristics of heating/sanitary exercises: Fireplace thermal power (heating)ÿmin-max: 3.5ú35.0ÿkW Useful thermal power (sanitary) min-max: 3.5ú35.0ÿkW Energy efficiency(92/42/CEE)ÿ**** Efficiency at Pn* (50øC-30øC): 105.5% Profitability 30% (47ø return): 108% Sealed chamber, forced draft Quantity of hot water at t 25øC: 20 l/min Minimum domestic water flow rate: 2ÿl/min Dimensions (hxwxd) mmÿ845 x 453 x 358ÿ; 44 kgs Electrical protection degrees: IP X5D NOx class: 5 Power supply: LPGÿ Features list FAMILY CONDENS Efficiency****ÿ Low polluting emissionsÿ Aluminum condenser, with premix burnerÿ Models for combined instantaneous and storage heating For indoor and outdoor recessed installations Family Condens a wall-mounted boiler that combines comfort, energy saving and respect for the environment with the best. The new primary heat exchanger completely made of aluminum with front access to the combustion chamber (models 2.5 and 3.0) guarantees better efficiency and duration. Family Condens available with powers from 2.8 to 35 kW. Features:ÿ Modulation ratio 1:10 (minimum power 2.8 kW) which allows the boiler to respond to all heat requestsÿ Modulating circulator, low consumption(IEE0,20)ÿ 3 Stars in sanitary comfort according to EN 13203ÿ Remote alarm system which allows remote signaling of the boiler lockout statusÿ Special Family functions: Wellness Tast, Memory Tast, Touch&Go function, Intelligent system fillsÿ Assembly template, hydraulic fittings and electric power cable suppliedÿ LPG conversion kit (G31) supplied for 3.5ÿ models Standard external probe ÿInstallation Benefits Performance secondDir. 92/42/EEC. Circulator lowconsum(IEE0,20) Climatic adjustment managed directly by the boiler control unitÿ Special Family functions: TastBenessere, TastMemory, Touch&Go function Smart Fillsÿ Assembly template, hydraulic fittings, power supply cable supplied ErP: Energy related Products ErP the acronym for Energy related Products? (products connected to the use of energy) and the abbreviation that identifies the European Directive ErP 2009/125/EC, defined by the EEC with the intention of reducing the energy consumption of products through eco-compatible design (or eco-design?). The scope of action of this European Directive is extremely broad since up to now it has affected products such as light bulbs, air conditioners, washing machines, fans, etc. Following the publication in September 2013 of a series of implementing regulations, starting from 26 September 2015 they will also apply to heating products and the production of domestic hot water. Also from the same date, other regulations will also become effective which will implement the energy labeling of the same product families. The transitional period between the publication of the regulations and their activation throughout the territory of the European Community is necessary to allow the full transposition of the contents by companies and market players. The regulations issued require that all products intended for heating and/for the production of domestic hot water, with a nominal thermal power lower than or equal to 70 kW, are placed on the market with an ÿenergy labelÿ that highlights their efficiency class. Note: the regulation provides for the mandatory presence of the energy label for the introduction of the product from the factories to the market. All the products previously introduced, for example present near distribution warehouses, can be regularly marketed even if they do not have an energy label. Various energy labels have been provided based on the use of the generator used: for heating from A++ to G; for the production of domestic hot water from A to G. The purpose of energy labels is to allow the consumer to easily identify the level of efficiency of a product, to be able to make a homogeneous comparison between products that use different technologies. For products whose transformation efficiency is influenced by external conditions, such as heat pump products, as well as those on air conditioners, the efficiency data reported for the average climatic zone. In addition to product energy labels, European regulations have also provided for the creation of a "system label" in the case of building a plant in which various appliances, components and controls operate. This labelling, thanks to the combinations of the data of the various elements used in the plant, will allow the creation of systems capable of reaching levels of efficiency even higher than those of the individual generators. The European regulation states that the system label must be made available by whoever supplies and/operates the system (sellers-installers); but this faculty is also granted to builders. Warranty All products for sale on our site are new and packed. The guarantee on this article is 24 months from the date of purchase.
€1.592,00