Wall mounted condensing boilers
CHAFFOTEAUX Gas Boiler Chaffoteaux Urbia Green Ebus2 35 Eu LPG Condensing Complete Kit For Smoke Exhaust -New Erp
Overview CHAFFOTEAUX URBIA GREEN Ebus2 35 EU CONDENSING BOILER Cod. 3310409 COMPLETE WITH FUME EXHAUST KIT -NEW ErP 2015: Wall mounted condensing boilers with 4 liter mini-accumulator. Technical specifications Product code: 3310409 Energy label specifications according to the European ErP directive Class A heating energy efficiency Sanitary energy efficiency Class A Withdrawal profiles: XL Characteristics of heating/sanitary exercises: Nominal heat output max/min (Hi) Qn:ÿ31/3,5ÿkW Useful heating power80§ C/ 60§ C max/minÿ30.3/3.4ÿkW Useful heating power50§ C/ 30§ C max/minÿ33/3,6ÿkW Sanitary nominal thermal power max/min (60/80§C) PCI:ÿ34.5/ 7ÿkW Efficiency at nominal heat input:ÿ97.7% Efficiency 30% of nominal heat input:ÿ108.7% Energy efficiency stars: (dir 92/42/CEE) **** Capacity of the expansion vessel: 8 lt Maximum system water capacity: 100/300 litres Sanitary comfort stars(EN13203): *** Port. specific in healthcare (10 min. with T= 30øC): 16.5 l/min Hot water flow rate at T 25§ C: 19.3 l/min Degrees of protection for the electrical system:ÿIPX5D Nox class: 5 Dimensions hxwxd: mmÿ745 x 440 x 445ÿ; 46kg LPG fuel supply or Features list URBIA GREEN Ebus2 EU Urbia Green is the ideal solution for all homes where the best performance is required. It is a concentration of advantages in terms of sanitary comfort with reduced dimensions and consumption. Thanks to condensing technology and integration with solar systems, it maximizes energy savings and the 4-litre sanitary reserve satisfies the needs of the most demanding users. Sanitary comfort Mini-accumulintegrated in 316L stainless steel of 4 liters. Domestic hot water performance ***, maximum level not foreseen by the EN 13203 standard. Flow rate from 14.6 to 19.3 l/min with T = 25§C. DHW production controlled by a modulating turbine to respond to needs without waiting times and at a constant temperature, even when extractions are very low. DHW programmer to control the tank heating time slots Eco-Delta System: DHW load system with 4 liter reserve to further improve the comfort of DHW production and new ecological functions which allow you to save energy in DHW mode. Heating comfort Efficiencyfinal 108% with energy savingsfinal 35%. 4-star combustion efficiency according to the EN 92/42 standard. SRA function, automatic boiler regulation system according to heating requirements. Modulation wide range, from 10% to 100% of the maximum power. Reduced polluting emissions, NOx class 5. Pressure sensor of the heating circuit with visualization on LCD display. High efficiency circulator with continuous modulation to improve acoustic comfort and reduce energy consumption. Differentiated climatic thermoregulation of 2 circuits, according to the room and/or outside temperature. Arrangement for integration into a heating system via the newÿEbus2 communication protocolÿ(boilers, solar, system management modules, modulating thermoregulation accessories). Multifunction LCD display with display: history, self-diagnosis, operating temperature. Filling taps integrated in the boiler. Convenience of installation use Compatible with Expert Control: intuitive system manager for the management of 3 circuits, according to the room and/or outside temperature for greater comfort and greater energy savings. New intuitive electrical connections. Easier start-up: automatic purge function and directly accessible combustion adjustment. Save energy and respect the environment Final 25% energy savings in combination with Expert Control and the SRA function. Final 35% energy savings combine and Expert Control, the SRA function, the external probe and the radiant floor. 40% reduction in CO2 emissions**. ERP extension From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy intensive sectors: construction For placing on the European market, the directive on ÿeco-designÿ(ErP notcome®ÿEnergy Related Productsÿ¯) imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres As in the household appliances sector, the energy labelingÿof products, with a capacity of less than 70 kW, will give consumers simple, recognizable information which allows them to make comparisonsÿon the performance and energy consumption of the product they wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. The information indicated on the energy labelÿwill allow professionals to recommend the right productÿÿindividuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015, the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. The company that supplies the product on the market is required to equip its system devices with the following documentation: product energy label;ÿ product data sheet;ÿ system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices;ÿ technical data sheet of the system with the parts relating to the products and the system already completed. First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device/system to the public. Therefore, even professionals such as plumbers, installers, designers can fall into this category. All bound to ensure that: all appliances and/systems having their respective labels and making sure they are clearly visible;ÿ all appliances and/systems must always be accompanied by the obligatory technical data sheets;ÿ every type of advertising material, technical promotional material which shows energy data and price indications, contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and the production of hot water will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP): The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL There are different labels depending on the type of appliance. Those with efficiency classes A, A+ and A++ certify products with the highest performance. Furthermore, two different classifications are foreseen for domestic heating and for hot water production services, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the end customer can make his choice in the most aware way possible. SYSTEM LABEL In addition to the product label, the system label is also providedÿin cases where a series of appliances combined with each other is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label so as to inform the end user in the best possible way. Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.243,00
Ferroli Ferroli Bluehelix Tech 35c Methane Condensing Gas Boiler Complete With Kit For Fume Exhaust -Erp
Overview FERROLI BLUEHELIX TECH 35C CONDENSING BOILER COMPLETE WITH FUME EXHAUST KIT - NEW ErP 2015: Wall-mounted condensing, premixed, sealed chamber boilers with instantaneous domestic hot water production with double exchanger. IN THE ABSENCE OF THE PRODUCT, THE NEW MODEL BLUEHELIX RRT C 34 WILL BE SUPPLIED, which can be viewed at this link: https://www.climaconvenienza.it/it/caldaia-a-gas-ferroli-bluehelix-tech-rrt-34c-metano-o-gpl-completa-di-kit-scarico-fumi-new/ Technical specifications Energy label specifications according to the European ErP directive Class A heating energy efficiency Sanitaryware energy efficiencyprofilXXL Class A Characteristics of heating/sanitary exercises: Sealed chamber condensing boiler Thermal input (PCI)ÿMax Heating: 32 kW Thermal capacity (PCI)ÿMax DHW: 34.8 kW Heating power 80øC-60øCÿMax Heating:ÿ31.4 kW Thermal power 80øC-60øCÿMax Sanitary:ÿ34.1 kW Thermal efficiencyÿ80øC-60øC: 98% Useful thermal efficiencyÿ50øC-30øC: 106.1% Efficiency termicuseÿCaricridott30%: 108.8% Domestic hot water productionÿt 30øC: 16.3 l/min Domestic hot water productionÿt 25øC: 19.5 l/min Energy certification (92/42 EEC): **** Degrees of protection: IPX5D Extremely compact dimensions (hxlxp): 600 x 400 x 320 mm; 31kg Power supply: METHANE Features list BLUE HELIX TECH Wall-mounted condensing boilers, premixed sealed chamber with instantaneous sanitary production New series of compact wall-mounted condensing boilers with instantaneous domestic hot water production. Designed to guarantee maximum energy efficiency in heating and in the supply of domestic hot water, thanks to the new bivalent exchanger patented in AISI 316 TI stainless steel. This new exchanger integrates the heating circuit and the production of domestic hot water in a single element, pushing the phenomenon of condensation to the maximum. Built to be installed outdoors in partially protected places and equipped with electronics capable of integrating with a solar panel system. The range: Range made up of two models, respectively 27 and 35 kW, running on methane, LPG, propane air. Strengths: Boiler body with patented high performance primary heat exchanger in AISI 316 TI stainless steel Instantaneous production of domestic hot water with a dedicated plate domestic hot water exchanger Total premix burner in stainless steel Digital control panel Electronic flame modulation in both heating and DHW Can be combined with the modulating remote timer control Large graphic multifunction display with backlighting for easy and correct setting of the parameters Standard by-passÿ Refined design compact size Casing painted white by anaphoresis with epoxy powders Advantages : ÿECOÿfunctionin sanitaryware for greaterÿsavingÿin the period of low use of hot water 3-star certified comfort in sanitary production according to EN 13203 Sliding temperature operationÿby means of an optional external probe Low-consumption modulating heating circulator (Erp Ready - Class A):ÿRegulation 622/2012 requires that all boilers placed on the market from 1 August 2015 be equipped with a low-consumption circulator, otherwise defined as class A. This is a decision that starts from consideration of the enormous energy expenditure of the pumps and circulators installed in the various applications. In practice, or by analyzing the impact of the low-consumption circulator integrated in the boiler, this reduces the total electricity consumption of the generator by 30%. Digital flame monitor with three re-ignition attempts in the event of blockage due to lack of flame detection (methane model) Predisposition for solar systems:ÿpredisposed for the production of domestic hot water combined with solar panel systems Place of installation:ÿalso for outdoorsin a partially protected place up to -5øC as standard and up to -15øC with the aid of the optional antifreeze heater kit Operation certified also with propane airÿ (50% air - 50% G31) by means of a specific transformation to be requested from the Authorized Assistance Center Appliance belonging to class 5, the most ecological required by European standards (UNI EN 297 NOX and 483) Products that fall under the tax benefits provided for by the Finance Law in force Functions: ECO-COMFORT function: In COMFORT mode, thanks to the particular system for maintaining the temperature of the heat exchanger, the delivery of domestic hot water becomes even more rapid and comfortable. In ECO mode, the production of domestic hot water takes place according to traditional standards. Sliding temperature operation:ÿWith the installation of the kit or External probe? possible to operate the boiler in sliding temperature. This means that without acting on the system temperature adjustment keys, the boiler will self-regulate according to the variations in external temperatures. All this translates into energy savings while guaranteeing maximum comfort for the user. Antifreeze function: In the event that the temperature in the boiler drops to 5°C, the burner automatically lights up and the circulator is activated in order to protect the appliance from damage caused by freezing. This function is active with the boiler powered by the gas circuit and electrical undervoltage. Sun Easy function: BLUEHELIX TECH has been designed to be easily inserted in systems made with the most recent technologies. The SUN EASY system, standard on the boiler, makes use of electronics that simplify the combination with both natural and forced circulation solar panels. By means of a post sensor on the sanitary circuit, it continuously checks the temperature of the water coming from the solar panels, foreseeing the ignition of the burner only when the latter drops to the level necessary to guarantee optimal comfort for the user. Tangible facts: Regulation 622/2012 provides that all boilers placed on the market from August 1, 2015 be equipped with a low-consumption circulator, otherwise defined as class A. This is a decision that starts from the consideration of the enormous energy expenditure of the pumps and circulators installed in the various applications. In practice, or by analyzing the impact of the low-consumption circulator integrated in the boiler, this reduces the total electricity consumption of the generator by 30%. consumption max. standard non-modulating circulator:ÿ0.085 kWÿ consumption max. new high efficiency circulator:ÿ0.04 kWÿ Degree daysÿ2500ÿ(average climate zone E)ÿ Energy cost:ÿ0.19 ??¶/kWhÿ Hypothetical annual expenditure at max standard circulator speed:ÿ40.375 ??¶ÿ Hypothetical annual expenditure max speed high efficiency circulator:ÿ11.4 ??¶ÿ Therefore, with the replacement of standard boilers with Bluehelix Pro, in line with the new ERP regulations, electricity savings of around 30% can be estimated. In reality, the savings will be even greater, since these are modulating circulators, which at minimum power can reach consumption of up to just 3 W ERP extension The new European regulations for heat generatorsÿ The 4 ErP Regulations on: ÿEcodesignÿ (minimum efficiency limits) and Energy Labeling (information energy label) are mandatory European provisions automatically in force from 26 September 2015 simultaneously in the 28 EU countries and in all EEA countries (European Economic Areas: Liechtenstein, Switzerland, Norway, Iceland). The Regulations (or EU Regulation? nr.: 811/2013, 812/2013, 813/2013 and 814/2013) are already published by the EU and are legal provisions which leave no legislative power (of modification/variation of delayed adoption) to the EU Member States, in so far as they do not require any national law of adoption, but come into force automatically or per se? throughout Europe.ÿ From 26th September 2015, boilers, heat pumps, tanks/boilers, water heating systems or non-ErP compliant systems will not be able to leave the factories and warehouses of MANUFACTURERS (nor from the warehouses of IMPORTERS from outside the EU), except for products for which it has already been carried out the placing on the market or the transfer of formal ownership (before 26 September) to the first customer/distributor of the commercial chain. The date which is the date on which the finished product was first placed on the market. In practice, by virtue of the new Regulations, manufacturers in the EU area and importers from outside the EU will be obliged to offer for sale only highly efficient products and systems, both for space heating and for the preparation of domestic hot water. Will the end customer be able to find latest generation products immediately on the market? which will be compulsorily accompanied by the ENERGY LABEL and compliant with the MINIMUM LIMITS calculated according to strict European standards which for the first time for these new products or ErP? considers all types of direct and indirect consumption of appliances, e.g. gas consumption and electricity consumption in a boiler.ÿ New ErP efficiency limits (and noise for heat pumps only) will apply to heating systems (boilers and heat pumps) up to 400 kW, to instantaneous gas and electric water heater systems up to 400 kW, to DHW tanks up to 2,000 kW lt. All new products and systems must be of very high efficiency, with the sole exception of tipB1x boilers (open chamber with natural draft) which will have a special derogation and may still be manufactured and sold exclusively to be installed in REPLACEMENTS on COLLECTIVE FLUES . Heat pumps will have to comply with new minimum limits for noise emissions, while for boilers the noise value will have to be indicated (without limit constraints). Furthermore, even the circulators mounted on board all the products must comply with new minimum efficiency standards (very high efficiency), based on the specific EU Regulations (nr. 641/2009 and nr. 622/2012). To make the most of all the possibilities offered by the energy label, will it be possible to predict and declare their use in a system right from the product conception and development stage? with other devices (e.g. regulation and control), thus proposing a globally more efficient whole, e.g. eg. through the use of renewable sources (solar thermal, geothermal aerothermal energy, biomass). Even the so-called or standard products? today the best sellers - i.e. boilers for gas heating - will undergo a forced evolution towards technology with heat recovery from fumes (condensing boiler). We remind you that condensing boilers can recover the heat from the fumes in most of the existing systems, even those with radiators, with the use of thermostatic valves now available in various models (also programmable individually on different times), due to their different conception of design incorporating substantial improvements over previous or standard boilers? such as the new highly efficient modulating circulators and the combustion control volume in the new premix burners. Subsequently, for products sold by manufacturers and importers from outside the EU after 26 September 2018, more stringent limits for NOx emissions will come into force Theÿ20/20/20 climate-energy package?ÿsets ambitious targets for the reduction of greenhouse gas emissions, energy consumption as well as the increase in the use of renewable energies, corresponding to a percentage of 20% to be reached by 2020. In this context , the regulationeuropeErP (Energy Related Products) introduces an energy classification also for hot water generators for space heating and domestic hot water purposes. This classification translates into an ÿenergy labelÿ which must necessarily accompany all the products affected by the Regulation, introduced on the market from 26 September 2015. The labeling constitutes an easy guide for the consumer, who can choose - through standardized and objective indications - the most efficient product. In this way, the choice will be the most sparing in terms of consumption for the benefit of the user, but also the most virtuous for energy balances and consequently, for the environment. The most significant parameters indicated on the label are the seasonal efficiency index in heating and efficiency in the eventual production of domestic hot water, according to a scale which in the casdel prodottsingolcaldaia ranges from A to G*. Furthermore, for combined boilers, a load profile is indicated corresponding to the domestic hot water flow rate of the appliances measured in a series of sample samples, thus guaranteeing the declared sanitary efficiency. This index is identified with a letter/?size? (S, M,¶ÝXXL). Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€895,00
Riello Riello Residence Condens 35 Kis Condensing Boiler Complete With Low Nox Methane Flue Kit Class A - New
Riello Residence Condens 35 kis condensing boiler complete with Low NOx Methane Fume Kit class A - NEW Class A heating energy efficiency Sanitary energy efficiency profile XL Class A Heating/DHW operating characteristics Heating nominal heat input kW 30 Nominal thermal power (80°-60°) heat kW 29.2 Maximum heating pressure bar 3 DHW nominal heat input kW 34.6 DHW nominal thermal power* kW 36.3 Hot water production with t+25 °cl/min 17.4 NOx class 5 Dimensions HxWxD mm 740x420x350 Electrical data Total electric power (pmax heating) W 75 Supply voltage V - Hz 230 - 50 IP X5D degree of protection Power supply: METHANE RESIDENCE CONDENS RIELLO PRESENTS RESIDENCE THE NEW RANGE OF CONDENSING BOILERS NEW EXCHANGER Wrapped stainless steel primary exchanger. Efficiency and reliability in the heart of the Residence. DOMESTIC COMFORT FUNCTION Domestic water pre-heating with Touch&Go function for activation upon request directly from the drawing tap. ACTIVE COMBUSTION CONTROL Advanced electronic combustion control system which constantly monitors combustion to obtain constantly optimized consumption and emissions. DIGITAL USER INTERFACE Simple and intuitive backlit LCD display. Ease of setting thanks to the silk-screened keys dedicated to the individual user functions. MODULATING CIRCULATOR High efficiency circulator with flow rate modulation and regulation logic that can be set between different modes according to the type of system. HIGH EFFICIENCY The high efficiency of the primary exchanger, the modulating circulator and the continuous control of the combustion parameters guarantee very low consumption even after years of operation. QUICK INSTALLATION Speed and ease of installation thanks to the compact dimensions, accessibility of the components and external electrical connections. UNIQUE VERSION METHANE - LPG Dedicated codes are no longer necessary in the case of LPG because Residence is able to automatically adapt its operation to the type of fuel with rapid setting from the display. FLEXIBLE INSTALLATION The characteristics of Residence and its compact dimensions make it the ideal solution for both indoor and recessed installation (model 25 KIS only) or outdoors in a partially protected place. RESIDENCE, HEART OF STEEL The new RESIDENCE exchanger is made of stainless steel, with a smooth tube with a large section to guarantee the best efficiency and cleanliness over time. NEW PRIMARY EXCHANGER IN STAINLESS STEEL The single coil geometry (hydraulic circuit in series) guarantees constant flow in all sections of the exchanger and intrinsically prevents clogging. Front access facilitates periodic maintenance and cleaning of the combustion chamber. SELF-ADAPTING ELECTRONIC COMBUSTION CONTROL The new Residence is equipped with the intelligent ACC combustion control system, which guarantees that the process always takes place in an optimal manner in any condition, thanks to the modulating gas valve and the ionization electrode. Thanks to the ACC, Residence is able to automatically adapt to the fuel (methane or LPG) without resorting to specific codes or accessory conversion kits. Residence also reacts to the variation of the fuel title and to the pressure drops on the flue gas side. The ACC system detects the excess air value and intervenes by modulating the mixture. The ACC system also simplifies installation. During ignition, it does not require calibration and it is sufficient to select the type of combustible gas used by the boiler via the interface, if different from the default one (methane). Since the system keeps the value of the CO2 produced constant, even the smoke control during the ignition phase is no longer necessary for the correct functioning of the product. Controlling combustion also means guaranteeing constant emissions, which are always well below the limits set by the law. In fact, if the process takes place in an optimal manner, the gases produced will also have the best theoretical composition with respect to the other conditions. MANY NEEDS, ONE SOLUTION RESIDENCE IS ALWAYS THE IDEAL CHOICE THANKS TO THE TECHNICAL SOLUTIONS AND THE COMPACT DIMENSIONS, IT CAN BE USED IN ANY INSTALLATION SITUATION INTERIOR Inside the home, thanks to an elegant aesthetic that allows it to be inserted pleasantly into any environment. OUTDOOR Outdoors in a partially protected place, thanks to the IPX5D degree of protection and the accessory antifreeze heater kit RECESSED Inside a built-in box thanks to its compact dimensions (model 25 KIS only). NEW DIGITAL CONTROL Setting your own comfort for domestic hot water, air and heating is immediate thanks to the buttons with symbols dedicated to the individual functions Domestic hot water temperature setting Operating status 0FF - SUMMER - WINTER Unlock and restore alarms Information and parameters menu Product Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.205,00
Ariston Ariston Condensing Boiler Genus One Net 35 Kw Methane Complete With Fume Exhaust Kit
CAUTION Methane, LPG and propane air operation without the need for a kit. The transformation takes place thanks to the combustion control by selecting the type of gas from the technical menu. For info, contact the local authorized assistance center in advance ARISTON CONDENSING BOILER GENUS ONE NET 35 KW METHANE COMPLETE WITH FUME EXHAUST KIT Technical features Energy class in heating: A; Energy class in sanitary: A; Profile: XL; Forced draft sealed chamber; Energy data: Nominal heat flow in heating (max/min): 31.0/3.5 kw; DHW nominal heat input (max/min): 34.5/3.5 kw; Thermal power (max/min) from 80° C- 60° C: 30.3/3.3 kw; Thermal power (max/min) from 50° C- 30° C: 33.5/3.6 kW; DHW thermal power (max/min): 33.1/3.4 kW Combustion efficiency (flue gas) 97.8% Efficiency at nominal heat input from 60/80° C: 97.7% Efficiency at nominal heat input from 30/50° C: 108.0% Performance Stars: 4**** Expansion tank pressure: 1 bar; Max pressure: 3 bar; Expansion tank capacity 8 l; High temperature range (min.max): 35/82 °C; Low temperature range (min/max): 20/45 °C; Exercise performance in healthcare: Min/max domestic hot water temperature: 36/60 °C Specific flow rate (10 min. with ∆T=30°C): 16.5 litres/min; Quantity of hot water ∆T=25°C: 19.8 litres/min; Quantity of hot water ∆T=35°C: 14.1 litres/min; Comfort performance stars (EN13203) ★★★ Supply voltage/frequency V/Hz 230 / 50 Minimum ambient temperature of use: >0°C; Power consumption: 82W; Electrical protection: IP X5D; Drain: 80, 60, 50mm; Power supply: LPG (G31, Propane) General characteristics New generation Ariston condensing boiler, it is the perfect mix of innovation and maximum comfort at your fingertips, in fact by connecting the appliance (also thanks to the Cube S NET, the room thermostat with integrated connectivity) to your smartphone or tablet via the appropriate downloadable app for both IOS or Android, the efficiency of the boiler connected to your smartphone give the maximum desired comfort. Installation in partially protected places or with suitable boiler covers is recommended due to the need for outdoor installation to better protect the appliance. Equipped with a large Dsplay with backlit touch interface to view correct operation and regulation or in the event of boiler malfunction for rapid intervention by authorized personnel. To always have domestic hot water ready, the Genus One Net boiler works with a high-efficiency circulator with continuous modulation (ratio 1:10) so as to respond quickly to the user's needs. Finally, the boiler is extremely silent, guaranteeing minimum acoustic disturbance, guaranteeing fewer cycles on and off the boiler and a new silencer and sound-absorbing panels that allow minimum noise. Advantages: Prepared for integration into system configuration Through the new Bus Bridgenet® communication protocol; Arrangement for multi-zone and multi-temperature thermoregulation; Arrangement for solar system management; Functions: Car and comfort function; Isothermal primary heat exchanger in stainless steel; Increased DHW exchanger; Ignition system; electronic combustion control; Gas transformation from the technical menu; Cold water inlet and heating return filters; Dimensions (HxWxD) 745x440x385mm; Weight: 37.6Kg; Product Guarantee All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.377,00
Ferroli Ferroli Bluehelix Tech 35c LPG Condensing Gas Boiler Complete With Fume Exhaust Kit -Erp
Overview FERROLI BLUEHELIX TECH 35C CONDENSING BOILER COMPLETE WITH FUME EXHAUST KIT - NEW ErP 2015: Wall-mounted condensing, premixed, sealed chamber boilers with instantaneous domestic hot water production with double exchanger. IN THE ABSENCE OF THE PRODUCT, THE NEW MODEL BLUEHELIX RRT C 34 WILL BE SUPPLIED, which can be viewed at this link: https://www.climaconvenienza.it/it/caldaia-a-gas-ferroli-bluehelix-tech-rrt-34c-metano-o-gpl-completa-di-kit-scarico-fumi-new/ Technical specifications Energy label specifications according to the European ErP directive Class A heating energy efficiency Sanitaryware energy efficiencyprofilXXL Class A Characteristics of heating/sanitary exercises: Sealed chamber condensing boiler Thermal input (PCI)ÿMax Heating: 32 kW Thermal capacity (PCI)ÿMax DHW: 34.8 kW Heating power 80øC-60øCÿMax Heating:ÿ31.4 kW Thermal power 80øC-60øCÿMax Sanitary:ÿ34.1 kW Thermal efficiencyÿ80øC-60øC: 98% Useful thermal efficiencyÿ50øC-30øC: 106.1% Efficiency termicuseÿCaricridott30%: 108.8% Domestic hot water productionÿt 30øC: 16.3 l/min Domestic hot water productionÿt 25øC: 19.5 l/min Energy certification (92/42 EEC): **** Degrees of protection: IPX5D Extremely compact dimensions (hxlxp): 600 x 400 x 320 mm; 31kg Power supply: LPG Features list BLUE HELIX TECH Wall-mounted condensing boilers, premixed sealed chamber with instantaneous sanitary production New series of compact wall-mounted condensing boilers with instantaneous domestic hot water production. Designed to guarantee maximum energy efficiency in heating and in the supply of domestic hot water, thanks to the new bivalent exchanger patented in AISI 316 TI stainless steel. This new exchanger integrates the heating circuit and the production of domestic hot water in a single element, pushing the phenomenon of condensation to the maximum. Built to be installed outdoors in partially protected places and equipped with electronics capable of integrating with a solar panel system. The range: Range made up of two models, respectively 27 and 35 kW, running on LPG, LPG, propane air. Strengths: Boiler body with patented high performance primary heat exchanger in AISI 316 TI stainless steel Instantaneous production of domestic hot water with a dedicated plate domestic hot water exchanger Total premix burner in stainless steel Digital control panel Electronic flame modulation in both heating and DHW Can be combined with the modulating remote timer control Large graphic multifunction display with backlighting for easy and correct setting of the parameters Standard by-passÿ Refined design compact size Casing painted white by anaphoresis with epoxy powders Advantages : ÿECOÿfunctionin sanitaryware for greaterÿsavingÿin the period of low use of hot water 3-star certified comfort in sanitary production according to EN 13203 Sliding temperature operationÿby means of an optional external probe Low-consumption modulating heating circulator (Erp Ready - Class A):ÿRegulation 622/2012 requires that all boilers placed on the market from 1 August 2015 be equipped with a low-consumption circulator, otherwise defined as class A. This is a decision that starts from consideration of the enormous energy expenditure of the pumps and circulators installed in the various applications. In practice, or by analyzing the impact of the low-consumption circulator integrated in the boiler, this reduces the total electricity consumption of the generator by 30%. Digital flame monitor with three re-ignition attempts in the event of blockage due to lack of flame detection (LPG model) Predisposition for solar systems:ÿpredisposed for the production of domestic hot water combined with solar panel systems Place of installation:ÿalso for outdoorsin a partially protected place up to -5øC as standard and up to -15øC with the aid of the optional antifreeze heater kit Operation certified also with propane airÿ (50% air - 50% G31) by means of a specific transformation to be requested from the Authorized Assistance Center Appliance belonging to class 5, the most ecological required by European standards (UNI EN 297 NOX and 483) Products that fall under the tax benefits provided for by the Finance Law in force Functions: ECO-COMFORT function: In COMFORT mode, thanks to the particular system for maintaining the temperature of the heat exchanger, the delivery of domestic hot water becomes even more rapid and comfortable. In ECO mode, the production of domestic hot water takes place according to traditional standards. Sliding temperature operation:ÿWith the installation of the kit or External probe? possible to operate the boiler in sliding temperature. This means that without acting on the system temperature adjustment keys, the boiler will self-regulate according to the variations in external temperatures. All this translates into energy savings while guaranteeing maximum comfort for the user. Antifreeze function: In the event that the temperature in the boiler drops to 5°C, the burner automatically lights up and the circulator is activated in order to protect the appliance from damage caused by freezing. This function is active with the boiler powered by the gas circuit and electrical undervoltage. Sun Easy function: BLUEHELIX TECH has been designed to be easily inserted in systems made with the most recent technologies. The SUN EASY system, standard on the boiler, makes use of electronics that simplify the combination with both natural and forced circulation solar panels. By means of a post sensor on the sanitary circuit, it continuously checks the temperature of the water coming from the solar panels, foreseeing the ignition of the burner only when the latter drops to the level necessary to guarantee optimal comfort for the user. Tangible facts: Regulation 622/2012 provides that all boilers placed on the market from August 1, 2015 be equipped with a low-consumption circulator, otherwise defined as class A. This is a decision that starts from the consideration of the enormous energy expenditure of the pumps and circulators installed in the various applications. In practice, or by analyzing the impact of the low-consumption circulator integrated in the boiler, this reduces the total electricity consumption of the generator by 30%. consumption max. standard non-modulating circulator:ÿ0.085 kWÿ consumption max. new high efficiency circulator:ÿ0.04 kWÿ Degree daysÿ2500ÿ(average climate zone E)ÿ Energy cost:ÿ0.19 ??¶/kWhÿ Hypothetical annual expenditure at max standard circulator speed:ÿ40.375 ??¶ÿ Hypothetical annual expenditure max speed high efficiency circulator:ÿ11.4 ??¶ÿ Therefore, with the replacement of standard boilers with Bluehelix Pro, in line with the new ERP regulations, electricity savings of around 30% can be estimated. In reality, the savings will be even greater, since these are modulating circulators, which at minimum power can reach consumption of up to just 3 W ERP extension The new European regulations for heat generatorsÿ The 4 ErP Regulations on: ÿEcodesignÿ (minimum efficiency limits) and Energy Labeling (information energy label) are mandatory European provisions automatically in force from 26 September 2015 simultaneously in the 28 EU countries and in all EEA countries (European Economic Areas: Liechtenstein, Switzerland, Norway, Iceland). The Regulations (or EU Regulation? nr.: 811/2013, 812/2013, 813/2013 and 814/2013) are already published by the EU and are legal provisions which leave no legislative power (of modification/variation of delayed adoption) to the EU Member States, in so far as they do not require any national law of adoption, but come into force automatically or per se? throughout Europe.ÿ From 26th September 2015, boilers, heat pumps, tanks/boilers, water heating systems or non-ErP compliant systems will not be able to leave the factories and warehouses of MANUFACTURERS (nor from the warehouses of IMPORTERS from outside the EU), except for products for which it has already been carried out the placing on the market or the transfer of formal ownership (before 26 September) to the first customer/distributor of the commercial chain. The date which is the date on which the finished product was first placed on the market. In practice, by virtue of the new Regulations, manufacturers in the EU area and importers from outside the EU will be obliged to offer for sale only highly efficient products and systems, both for space heating and for the preparation of domestic hot water. Will the end customer be able to find latest generation products immediately on the market? which will be compulsorily accompanied by the ENERGY LABEL and compliant with the MINIMUM LIMITS calculated according to strict European standards which for the first time for these new products or ErP? considers all types of direct and indirect consumption of appliances, e.g. gas consumption and electricity consumption in a boiler.ÿ New ErP efficiency limits (and noise for heat pumps only) will apply to heating systems (boilers and heat pumps) up to 400 kW, to instantaneous gas and electric water heater systems up to 400 kW, to DHW tanks up to 2,000 kW lt. All new products and systems must be of very high efficiency, with the sole exception of tipB1x boilers (open chamber with natural draft) which will have a special derogation and may still be manufactured and sold exclusively to be installed in REPLACEMENTS on COLLECTIVE FLUES . Heat pumps will have to comply with new minimum limits for noise emissions, while for boilers the noise value will have to be indicated (without limit constraints). Furthermore, even the circulators mounted on board all the products must comply with new minimum efficiency standards (very high efficiency), based on the specific EU Regulations (nr. 641/2009 and nr. 622/2012). To make the most of all the possibilities offered by the energy label, will it be possible to predict and declare their use in a system right from the product conception and development stage? with other devices (e.g. regulation and control), thus proposing a globally more efficient whole, e.g. eg. through the use of renewable sources (solar thermal, geothermal aerothermal energy, biomass). Even the so-called or standard products? today the best sellers - i.e. boilers for gas heating - will undergo a forced evolution towards technology with heat recovery from fumes (condensing boiler). We remind you that condensing boilers can recover the heat from the fumes in most of the existing systems, even those with radiators, with the use of thermostatic valves now available in various models (also programmable individually on different times), due to their different conception of design incorporating substantial improvements over previous or standard boilers? such as the new highly efficient modulating circulators and the combustion control volume in the new premix burners. Subsequently, for products sold by manufacturers and importers from outside the EU after 26 September 2018, more stringent limits for NOx emissions will come into force Theÿ20/20/20 climate-energy package?ÿsets ambitious targets for the reduction of greenhouse gas emissions, energy consumption as well as the increase in the use of renewable energies, corresponding to a percentage of 20% to be reached by 2020. In this context , the regulationeuropeErP (Energy Related Products) introduces an energy classification also for hot water generators for space heating and domestic hot water purposes. This classification translates into an ÿenergy labelÿ which must necessarily accompany all the products affected by the Regulation, introduced on the market from 26 September 2015. The labeling constitutes an easy guide for the consumer, who can choose - through standardized and objective indications - the most efficient product. In this way, the choice will be the most sparing in terms of consumption for the benefit of the user, but also the most virtuous for energy balances and consequently, for the environment. The most significant parameters indicated on the label are the seasonal efficiency index in heating and efficiency in the eventual production of domestic hot water, according to a scale which in the casdel prodottsingolcaldaia ranges from A to G*. Furthermore, for combined boilers, a load profile is indicated corresponding to the domestic hot water flow rate of the appliances measured in a series of sample samples, thus guaranteeing the declared sanitary efficiency. This index is identified with a letter/?size? (S, M,¶ÝXXL). Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€915,00
CHAFFOTEAUX Gas Boiler Chaffoteaux Urbia Green Ebus2 35 Eu Methane Condensing Complete Kit For Smoke Exhaust -New Erp
Overview CHAFFOTEAUX URBIA GREEN Ebus2 35 EU CONDENSING BOILER Cod. 3310409 COMPLETE WITH FUME EXHAUST KIT -NEW ErP 2015: Wall mounted condensing boilers with 4 liter mini-accumulator. Technical specifications Product code: 3310409 Energy label specifications according to the European ErP directive Class A heating energy efficiency Sanitary energy efficiency Class A Withdrawal profiles: XL Characteristics of heating/sanitary exercises: Nominal heat output max/min (Hi) Qn:ÿ31/3,5ÿkW Useful heating power80§ C/ 60§ C max/minÿ30.3/3.4ÿkW Useful heating power50§ C/ 30§ C max/minÿ33/3,6ÿkW Sanitary nominal thermal power max/min (60/80§C) PCI:ÿ34.5/ 7ÿkW Efficiency at nominal heat input:ÿ97.7% Efficiency 30% of nominal heat input:ÿ108.7% Energy efficiency stars: (dir 92/42/EEC) **** Capacity of the expansion vessel: 8 lt Maximum system water capacity: 100/300 litres Sanitary comfort stars(EN13203): *** Port. specific in healthcare (10 min. with T= 30øC): 16.5 l/min Hot water flow rate at T 25§ C: 19.3 l/min Degrees of protection for the electrical system:ÿIPX5D Nox class: 5 Dimensions hxwxd: mmÿ745 x 440 x 445ÿ; 46kg METHANE power supply or Features list URBIA GREEN Ebus2 EU Urbia Green is the ideal solution for all homes where the best performance is required. It is a concentration of advantages in terms of sanitary comfort with reduced dimensions and consumption. Thanks to condensing technology and integration with solar systems, it maximizes energy savings and the 4-litre sanitary reserve satisfies the needs of the most demanding users. Sanitary comfort Mini-accumulintegrated in 316L stainless steel of 4 liters. Domestic hot water performance ***, maximum level not foreseen by the EN 13203 standard. Flow rate from 14.6 to 19.3 l/min with T = 25§C. DHW production controlled by a modulating turbine to respond to needs without waiting times and at a constant temperature, even when extractions are very low. DHW programmer to control the tank heating time slots Eco-Delta System: DHW load system with 4 liter reserve to further improve the comfort of DHW production and new ecological functions which allow you to save energy in DHW mode. Heating comfort Efficiencyfinal 108% with energy savingsfinal 35%. 4-star combustion efficiency according to the EN 92/42 standard. SRA function, automatic boiler regulation system according to heating requirements. Modulation wide range, from 10% to 100% of the maximum power. Reduced polluting emissions, NOx class 5. Pressure sensor of the heating circuit with visualization on LCD display. High efficiency circulator with continuous modulation to improve acoustic comfort and reduce energy consumption. Differentiated climatic thermoregulation of 2 circuits, according to the room and/or outside temperature. Arrangement for integration into a heating system via the newÿEbus2 communication protocolÿ(boilers, solar, system management modules, modulating thermoregulation accessories). Multifunction LCD display with display: history, self-diagnosis, operating temperature. Filling taps integrated in the boiler. Convenience of installation use Compatible with Expert Control: intuitive system manager for the management of 3 circuits, according to the room and/or outside temperature for greater comfort and greater energy savings. New intuitive electrical connections. Easier start-up: automatic purge function and directly accessible combustion adjustment. Save energy and respect the environment Final 25% energy savings in combination with Expert Control and the SRA function. Final 35% energy savings combine and Expert Control, the SRA function, the external probe and the radiant floor. 40% reduction in CO2 emissions**. ERP extension From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy intensive sectors: construction For placing on the European market, the directive on ÿeco-designÿ(ErP notcome®ÿEnergy Related Productsÿ¯) imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres As in the household appliances sector, the energy labelingÿof products, with a capacity of less than 70 kW, will give consumers simple, recognizable information which allows them to make comparisonsÿon the performance and energy consumption of the product they wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. The information indicated on the energy labelÿwill allow professionals to recommend the right productÿÿindividuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015, the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. The company that supplies the product on the market is required to equip its system devices with the following documentation: product energy label;ÿ product data sheet;ÿ system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices;ÿ technical data sheet of the system with the parts relating to the products and the system already completed. First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device/system to the public. Therefore, even professionals such as plumbers, installers, designers can fall into this category. All bound to ensure that: all appliances and/systems having their respective labels and making sure they are clearly visible;ÿ all appliances and/systems must always be accompanied by the obligatory technical data sheets;ÿ every type of advertising material, technical promotional material which shows energy data and price indications, contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and the production of hot water will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP): The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL There are different labels depending on the type of appliance. Those with efficiency classes A, A+ and A++ certify products with the highest performance. Furthermore, two different classifications are foreseen for domestic heating and for hot water production services, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the end customer can make his choice in the most aware way possible. SYSTEM LABEL In addition to the product label, the system label is also providedÿin cases where a series of appliances combined with each other is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label so as to inform the end user in the best possible way. Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.243,00
Riello Riello Family Condens 3.5 Kis Methane Condensing Boiler Complete With Smoke Kit - New Erp
Overview RIELLO FAMILY CONDENS 3.5 KIS METHANE CONDENSING BOILER COMPLETE WITH FUME KIT - NEW ErP 2015: Family Condens is a technologically advanced wall-mounted boiler that combines the best comfort, energy savings and respect for the environment. Technical specifications Product code:ÿ20021506ÿ Energy label specifications according to the European ErP directive Class A heating energy efficiency Sanitaryware energy efficiencyprofilXL Class A Characteristics of heating/sanitary exercises: Fireplace thermal power (heating)ÿmin-max: 3.5ú35.0ÿkW Useful thermal power (sanitary) min-max: 3.5ú35.0ÿkW Energy efficiency(92/42/CEE)ÿ**** Efficiency at Pn* (50øC-30øC): 105.5% Profitability 30% (47ø return): 108% Sealed chamber, forced draft Quantity of hot water at t 25°C: 20 l/min Minimum domestic water flow rate: 2ÿl/min Dimensions (hxwxd) mmÿ845 x 453 x 358ÿ; 44 kgs Electrical protection degrees: IP X5D NOx class: 5 Power supply: METHANEÿ Features list FAMILY CONDENS Efficiency****ÿ Low polluting emissionsÿ Aluminum condenser, with premix burnerÿ Models for combined instantaneous and storage heating For indoor and outdoor recessed installations Family Condens a wall-mounted boiler that combines comfort, energy saving and respect for the environment with the best. The new primary heat exchanger completely made of aluminum with front access to the combustion chamber (models 2.5 and 3.0) guarantees better efficiency and duration. Family Condens available with powers from 2.8 to 35 kW. Features:ÿ Modulation ratio 1:10 (minimum power 2.8 kW) which allows the boiler to respond to all heat requestsÿ Modulating circulator, low consumption(IEE0,20)ÿ 3 Stars in sanitary comfort according to EN 13203ÿ Remote alarm system which allows remote signaling of the boiler lockout statusÿ Special Family functions: Wellness Tast, Memory Tast, Touch&Go function, Intelligent system fillsÿ Assembly template, hydraulic fittings and electric power cable suppliedÿ LPG conversion kit (G31) supplied for 3.5ÿ models Standard external probe ÿInstallation Benefits Performance secondDir. 92/42/EEC. Circulator lowconsum(IEE0,20) Climatic adjustment managed directly by the boiler control unitÿ Special Family functions: TastBenessere, TastMemory, Touch&Go function Smart Fillsÿ Assembly template, hydraulic fittings, power supply cable supplied ErP: Energy related Products ErP the acronym for Energy related Products? (products connected to the use of energy) and the abbreviation that identifies the European Directive ErP 2009/125/EC, defined by the EEC with the intention of reducing the energy consumption of products through eco-compatible design (or eco-design?). The scope of action of this European Directive is extremely broad since up to now it has affected products such as light bulbs, air conditioners, washing machines, fans, etc. Following the publication in September 2013 of a series of implementing regulations, starting from 26 September 2015 they will also apply to heating products and the production of domestic hot water. Also from the same date, other regulations will also become effective which will implement the energy labeling of the same product families. The transitional period between the publication of the regulations and their activation throughout the territory of the European Community is necessary to allow the full transposition of the contents by companies and market players. The regulations issued require that all products intended for heating and/for the production of domestic hot water, with a nominal thermal power lower than or equal to 70 kW, are placed on the market with an ÿenergy labelÿ that highlights their efficiency class. Note: the regulation provides for the mandatory presence of the energy label for the introduction of the product from the factories to the market. All the products previously introduced, for example present near distribution warehouses, can be regularly marketed even if they do not have an energy label. Various energy labels have been provided based on the use of the generator used: for heating from A++ to G; for the production of domestic hot water from A to G. The purpose of energy labels is to allow the consumer to easily identify the level of efficiency of a product, to be able to make a homogeneous comparison between products that use different technologies. For products whose transformation efficiency is influenced by external conditions, such as heat pump products, as well as those on air conditioners, the efficiency data reported for the average climatic zone. In addition to product energy labels, European regulations have also provided for the creation of a "system label" in the case of building a plant in which various appliances, components and controls operate. This labelling, thanks to the combinations of the data of the various elements used in the plant, will allow the creation of systems capable of reaching levels of efficiency even higher than those of the individual generators. The European regulation states that the system label must be made available by whoever supplies and/operates the system (sellers-installers); but this faculty is also granted to builders. Warranty All products for sale on our site are new and packed. The guarantee on this article is 24 months from the date of purchase.
€1.553,00
Savio Gas Boiler Savio Evodens E 35s* Condensing Complete Kit For LPG Fume Exhaust - New Erp
Overview SAVIO evoDENS E 35S* CONDENSING BOILER COMPLETE WITH KIT FOR LPG FUME EXHAUST LPG - NEW ErP;ÿMedium range stainless steel condensing boiler Technical specifications Model:ÿevoDENS Product codeÿLPG: 103041002300 Product codeÿLPG: 103141003300 Characteristics of heating/sanitary exercises: Heating/DHW nominal heat inputÿ30.0 / 34.0 Heating/DHW minimum heat inputÿ8.5 Yield name 60ø/80øC %ÿ98.2 Yield min. 60ø/80øC %ÿ97.6 Rendimental 30% at 30øC:ÿ102.1 Energy efficiencynøÿ Minimum / maximum heating temperature**øC 25 / 85 Minimum / maximum heating pressurebar 0.3 / 3.0 Capacity of the expansion vessel (total / useful) l 7.0 / 3.5 Sanitary minimum / maximum temperatureøCÿ35 / 55 Sanitary minimum / maximum pressurebarÿ0.3 / 10.0 Maximum flow rate (T=25 K) / (T=35 K) l/minÿ21.6 / 15.6 Voltage / Power at nominal heat input V ~ /W 230 ~ / 114 Power at minimum thermal capacity W 10 Power at rest (stand-by) W 5 Degrees of protection nø IPX5D Dimensions HxWxD:ÿ700x400x290 mm; 37.0 kgs Boiler water content 2.5 l Main features evoDENS The new Savidi range of high efficiency wall mounted boilers dedicated to residential buildings. A complete range of powers, 24, 28 and 32 kW, for heating and the production of domestic hot water, inÿextremely compact dimensionsÿ (700 x 400 x 325 mm) makes Evodens a product suitable for different comfort needs.ÿEvodensÿe endowed with an aesthetic innovativeÿand a newÿimmediate and simpleÿto use interface. New functions make ÿEvodens an integral part of a system and facilitate its installation. Exchangers: Primary heat exchanger in copper, high circulation lamellar. Sanitary heat exchanger in stainless steel plates digital control panel:ÿInnovative digital control panel with graphical interface and buttons Ecodesign Directive: from 2015 on new condensing boilers In fact, after very long negotiations, the ÿEcodesign regulationÿ was approved, which introduces a new energy labeling on minimum efficiency standards for boilers.ÿIn particular, an energy classification from A+ to G is envisaged for space heating appliances and from A to G for appliances for the production of domestic hot water. ÿHence the obligation to installÿonly condensing boilers, heat generators capable of recovering a large part of the latent heat contained in the fumes which, otherwise, would be dispersed in the chimneyÿas occurs in traditional boilers. The recovered heat is transferred to the heating system, making it possible to achieve a yield of 106% with 92% of the traditional boiler and 84/85% of an oldÿÿtraditional generator.ÿThe installation obligation concerns manufacturers of boilers which will no longer be able to place on the market non-condensing starting from 26 September 2015. This means that starting from this date, anyone who wants to install a boiler in their own home will have to install only condensing models. Only one particular type of non-condensing boiler will continue to be produced which is technically called open room? to be installedÿ when it is not possible to replace an old boiler with a condensing boilerÿdue to problems related to the collective flueÿof some multi-family buildings. Products for heating water and the environment represent around 30% of the world's energy consumption in Europe.ÿ Designing eco-friendly products and promoting high performance technologies to end users in 2020 will lead to: An annual energy saving equivalent to 56 million tons of oil, quantifiable to the savings obtained if the water and environmental heating systems of two large nations like Italy were deactivated. As of 26 September 2015, the ErP regulation and ÿenergy labelingÿwill be applied in Europe to water and space heating products (boilers, heat pumps, micro-CHP devices, water heaters, and hot water storage tanks) u. How to read energy labels There are different labels, based on the type and function of the product (only room water heating of both, and in this case the label must bear both classifications). In addition to the energy class, the label provides other information that could be useful for understanding which product has the least environmental impact (for example power and consumption in different climatic zones, noise levels, etc.). It is possible to increase the energy efficiency of hot water production and space heating by connecting several products and accessories in one system. In this case it is necessary to prepare a system label in addition to that relating to the single product Warranty All products for sale on our site are new and packed. The guarantee on this article is 24 months from the date of purchase.
€1.245,00
Riello Riello Family Ar 35 Kis LPG Condensing Boiler Complete With Smoke Kit - New Erp
RIELLO FAMILY AR 35 KIS LPG CONDENSING BOILER COMPLETE WITH FUME KIT - NEW ErP Technical features Product code: 20100513 Energy label specifications according to the European ErP directive Class B heating energy efficiency Sanitary energy efficiency profile XL Class A Characteristics of heating/DHW operation: Furnace thermal power (heating) min-max: 9.9÷34.8 kW Useful heat output (sanitary) min-max: 9.9÷34.8 kW Energy efficiency (92/42/EEC) **** Useful efficiency at Pn* (50°C-30°C): 97.5% Profit return 30% (47th return): 96.5% Sealed chamber, forced draught Quantity of hot water with Δt 25°C: 20 l/min Minimum domestic water flow rate: 2 l/min Dimensions (hxlxp) mm 845 x 500 x 332 ; 48 kgs Electrical protection degree: IP X5D NOx class: 2 Power supply: METHANE FAMILY AR Yield **** Combined models for heating and domestic hot water production Family AR is the new generation condensing boiler specifically designed to operate with high temperatures (80°C delivery and 60°C return) and therefore in radiator systems. Family AR contains Altaresa condensing technology in the aesthetics and in the special Family functions. Family AR has an Air/Gas combustion (patented): thanks to the modulating fan, the mixture of air and gas is kept optimal and constant over the entire power range, always maintaining high efficiency. Thanks to the treated aluminum post-exchanger, very high yields up to 102.9% are obtained. The climatic regulation is managed directly by the boiler control unit, via the external probe (accessory), it allows the temperature of the heating system to be suitably adapted to the external climatic conditions. The equipment is completed by anti-freeze systems (down to -3°C), circulator anti-blocking systems, three-way valve, Wellness button and rapid button which reduces the waiting times for domestic hot water. Family AR is available with powers of 25, 29 and 35 kW. Characteristics: Technology, ease of control and management: • Memory key: activates machine intelligence. - sanitary: hot water always ready and without waste, according to the usage habits of the family. - in heating: reduction of home heating times. • Wellness key: maintains hot water delivery at the ideal temperature for the shower (40°C customizable +/- 5°C). • Touch&Go function: directly from the tap, it activates pre-heating for just one water draw. • Intelligent system filling: allows you to fill the system in complete autonomy. Air/gas combustion (patented): optimal mixture of gas and air to obtain high and constant efficiency over the entire power range with efficiency up to 102.9%. Condensing exchanger located downstream of the fan for further recovery of the heat contained in the exhaust fumes. Advantages for installation: Efficiency ★★★★ according to Dir. 92/42/EEC. Low consumption circulator (IEE≤0.20) Climatic regulation managed directly by the boiler control unit Special Family functions: Wellness key, Memory key, Touch&Go function Intelligent system filling Assembly template, hydraulic fittings, power supply cable supplied. Product Guarantee All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase
€1.615,00
Unical Unical Kon E C35 Low Nox Condensing Boiler Complete With Smoke Kit - New Erp
Unical KONe C35 Low NOx condensing boiler complete with flue kit - NEW ErP Model: KONe 35C Energy efficiency: Seasonal efficiency class for heating A Declared load profile: XL Sanitary seasonal efficiency class: A Technical data: Nominal useful power: 33.8kW Seasonal heating energy efficiency ambient ηs 93% Useful thermal power in high temperature regime. (Tr 60 °C / tm 80 °C): 18.2kW Efficiency at nominal thermal power in high temperature regime (Tr 60 °C / Tm 80 °C) η4: 87.5% Useful power at 30% of rated thermal power in low temperature regime (Tr 30 °C): 6.1 kW Efficiency at 30% of nominal thermal power in low temperature regime (Tr 30 °C) η1: 97.5% Annual electricity consumption QHE GJ: 56 Heating energy efficiency. of water ηWH: 85% Daily fuel consumption Qfuel : 23.13 kWh Sound power level indoors Lwa db(A) 55.2 Annual electricity consumption AEC: 402 kWh Specific sanitary water flow rate (Dt 30 °C): 16 l/min DHW production in cont. Dt 25 K (mixed): 18.3 l/min Expansion vessel capacity: 10 l Heating circuit pressure (min-max): 0.5-3.0 bar DHW circuit pressure (min-max): 0.5-6.0 bar IP X5D degree of protection NOx class: 6 Dimensions (HxWxD): 700x420x345 mm; 37kg KONe KONe is a wall-hung condensing boiler with very low polluting emissions, thus falling within the new Class 6, the most restrictive currently in force. It is available in instant combined version. KONe has all the "Quality Stars" to satisfy every need: Exceptional modulation ratio up to 1:8 Efficiency >107% (ex dir. CE 92/42) ηs 93% (EU regulation 813/2013 - dir. ERP 2009/125/CE) Energy class A Primary exchanger in ultra-flat Al/Si/Mg Electronics with HWS “Hot Water Speed” function (vers. C) Low NOx class 6 (according to EN 15502-1) thanks to the fully electronic modulating premix burner with constant combustion ratio (both gas valve and fan) Production of hot water up to 13.3 l/min Dt 25 with special 12-plate (mod. 24 C) and 16-plate (mod. 28/35 C) exchanger in AISI 316L stainless steel "Pit stop" maintenance for technical assistance interventions "Soft touch" control panel with "Upgradable" protective closure via USB connection for diagnostics/programming with computer or dedicated handheld tool High efficiency modulating circulator HWS "Hot Water Speed" is the special KONe electronics that switches from heating to DHW function with burner and pump always active, improving user comfort who does not have to wait for hot water Management of 2 zones with 2 thermostats (modulating/on -off) thanks to the electronics that allow you to manage 2 heating zones at different temperatures (high for radiators and fan-coils, low for radiant panel systems) Sliding temperature programmed to operate with the lowest possible delivery temperature to help save energy Anti-overheating post-circulation automatically after the burner goes out, the boiler keeps the pump running for 5 minutes, preserving the components Chimney sweep function allows maintenance technicians to carry out the checks required by current standards in terms of efficiency and emissions Pump anti-blocking the blocking of the pump following long stops is avoided thanks to an automatic impulse of 5 sec. Everything like in a “Sim Card” All the operating characteristics of the boiler are memorized inside a SIM. The Unical Assistance Center is equipped with a handheld instrument with a 3" touchscreen that can be connected directly to KONe to develop the monitoring activity by speeding up the intervention times for solving any problems: data acquisition for a computer analysis monitoring in real-time of the operating parameters even remotely (from the office or from the PDA) management of the "faults-history" “Pit stop” maintenance in less than 2 minutes KONe is the result of the experience of the Service and market suggestions, from which the Unical design staff has synthesized a technological complex that can be easily assembled and quickly disassembled. Product Guarantee All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.369,00
BERETTA Gas Boiler Beretta Exclusive 30c Methane Condensing Complete With Fume Exhaust Kit - Erp
Energy label specifications according to the European directive ErP: Heating energy efficiency: Class A XL profile DHW energy efficiency: Class A (EXCLUSIVE plus only the BeSMART Wi-Fi Comfort Control (optional) forms a class A+ system) Characteristics of operation in heating and DHW: Heating thermal capacity kW 24.00 Nominal DHW heat input kW 30.00 Nominal thermal power (80°/60°) kW 23.54 Nominal thermal power (50°/30°) kW 25.56 QHE Annual Power Consumption GJ: 42W Sound power level, within LWA dB 53 NOx emissions: mg/kWh 33 Max heating pressure-temperature: bar-°C 3-90 Diaphragm expansion vessel capacity: 8 l Hot water quantity at: ΔT 25 K / ΔT 30 K / ΔT 35 K l/min 17.2 / 14.3 / 12.3 Electrical protection degree: IP X5D NOx emission class: 6 Dimensions HxWxD:740x420x275 mm; 37kg Power supply: methane NEW EXCLUSIVE EXCLUSIVE, A NEW STORY BEGINS. Through the innovative ACC electronic injection combustion, HYBRID READY integration and the new project design, EXCLUSIVE offers exclusive advantages in every installation variation. From the new EXCLUSIVE, A NEW STORY BEGINS. construction, redevelopment; from hybrid application in a multi-energy system to simple single installation, EXCLUSIVE represents the current and winning choice for those who are not satisfied and want to look beyond. Characteristics: Electronic injection combustion via ACC system EXCLUSIVE plus only the BeSMART Wi-Fi Comfort Control (optional) forms a class A+ system 94% (ETAs) of energy efficiency in heating Universal installation : Indoor, outdoor and recessed installation. IPX5D electrical protection degree Tempozero installation: Removing the casing NO longer necessary for electrical connections and calibration Low consumption modulating circulator (EEI≤ 0.20) 6 m head, electronically modifiable up to 7 m Hydraulic connections and external probe available as options Frost protection down to -5 °C as standard HYBRID READY boiler , Can be integrated via BUS in a multi-energy system to make boiler operation more effective in relation to other energy sources (can be combined with a Beretta hybrid system using the REC 10H interface available as an accessory) Talking display: User interface for direct communication using TEXT and ICONS Self-adapting: The boiler automatically adapts to different types of gas and installation - ZERO calibrations CO alarm Boiler CO level constantly monitored and calibrated for maximum safety Small size: Thanks to its compactness, EXCLUSIVE can also be easily installed in a wall unit LPG version selectable from parameter Gas transformation kit not necessary Europe strategy With the opening towards the management of multi-energy plants, the reduction of emissions and the optimization of consumption, Beretta signs with EXCLUSIVE the highest contribution in terms of respect for the environment, in view of the 20-20-20 objectives of the Union countries expected by 2020, reconfirming their commitment to an increasingly eco-sustainable future. Exclusive: a milestone in the evolution of Beretta Combustion and electronics, i.e. the heart and brain of EXCLUSIVE, entirely designed in the Research and Development Laboratories of the historic Lecco headquarters, mark a turning point in Beretta's mural evolution and are the result of the spirit of innovation that has distinguished the brand since its origins. With EXCLUSIVE, the novelty of the project fits perfectly into the tradition of know-how and takes on a linear design, which reworks some aesthetic lines of the first boiler models in a modern key, in perfect continuity of style. Continuity that is also manifested in the re-proposition of the EXCLUSIVE name, which has always characterized the top of the Beretta range, with exclusive features and advantages. Class A+ system using only the BeSMART WiFi Comfort Control (optional) . "talking" interface The control panel is one of the distinctive elements of EXCLUSIVE which confirms its innovative profile. In fact, there are many EXCLUSIVE functions, all to be discovered, through a modern 3.5” backlit LCD display, which communicates with the user through texts and icons. By means of the intuitive silk-screened operating keys it is also possible to access the settings and parameterizations of the boiler and the system. GREEN GEM OF EXCLUSIVE: LED light bar that signals the current operating status of the boiler, reflecting on the casing even with the door closed. Exclusive Features: HOURLY PROGRAMMING : Programmable heating by hour and by single zone INTELLIGENT SYSTEM FILLING Autonomous filling activation and total safety SYSTEM PRESSURE Displayed DATE AND TIME Display as screensaver PREHEATING Domestic hot water preheating activation SCHEDULED MAINTENANCE Intelligent system that warns the user when boiler maintenance is due Everywhere Exclusive: Thanks to BeSMART, Beretta's WiFi Comfort Control, controlling and managing home comfort is now possible wherever you are, through a simple and intuitive App, via smartphone and tablet. EXCLUSIVE is compatible with all BeSMART functions, even the most advanced. From home heating professionals, easy management of home comfort. Even away from home Electronic injection combustion The ACC system, designed and developed by Beretta, allows in all circumstances to offer "first class" functionality, efficiency and low emissions. Using a sensor for detecting the flame ionisation current, which allows the electronics to continuously modulate the quantity of fuel injected, the system keeps the air/gas mixture constant at optimal values over the entire modulation range of the delivered power. Thanks to the ACC system, combustion adjusts itself, thus eliminating the need for any calibration and allowing the boiler to operate with different gas compositions. Particular attention is paid to CO emissions, through a self-diagnosis that intervenes on the burner before the emission threshold allowed by the legislation is exceeded. [A] Cylindrical burner in stainless steel [B] Integrated electronic board [C] Traditional ga valve with modulator [D] Modulating fan with Hall effect Hybrid Ready EXCLUSIVE is a HYBRID READY solution. The boiler was born as a fundamental element of the offer of HYBRID READY products, which constitute the new hybrid technology system conceived and developed in the Beretta Research Laboratories. This system, created to meet the current and future needs of integration and governance of the various energy sources (Gas/Electricity/Renewables), also includes the most innovative methods of energy accumulation and distribution. EXCLUSIVE, AS A HYBRID READY SOLUTION, IS THE IDEAL CHOICE FOR THOSE WHO WANT TO LOOK AHEAD AND INVEST IN A PRODUCT WHICH WILL MAINTAIN ITS ITS VALUE UNCHANGED OVER TIME. Thanks to the new communication BUS with which it is equipped, EXCLUSIVE is able to interact perfectly with the Energy Manager REC 10H, a real thinking brain that constantly monitors the hybrid system created, to always offer the best comfort in an efficient and effective way. The Beretta hybrid, distinguishing itself for its modular approach to the world of multi-energies, is therefore able to offer increasingly tailored comfort and to evolve over time, with the inclusion of new components that increase efficiency Beretta is “ERP”. The concrete commitment towards an eco-sustainable future The acronym ErP, acronym of "Energy related Products" (Products connected to the use of energy), identifies the Directive 2009/125/EC aimed at reducing the energy consumption of products through eco-compatible design. Starting from 26 September 2015 , the date of its effective entry into force in the European Union, it will mark an epochal turning point for heating products and the production of domestic hot water. On that date, other regulations simultaneously issued for the energy labeling of products will also become effective in addition to the corresponding Directive 2010/30/EU. The regulation provides that all products intended for heating and for the production of domestic hot water with a nominal thermal power lower than or equal to 70 kW can only be placed on the market with an energy label that highlights the efficiency class * . Different energy efficiency labels have been provided based on the different types of appliances/technologies, but all have the same graduated color scale that identifies the various levels of efficiency at a glance. The purpose of the labels is to give the consumer the possibility to easily identify the level of efficiency of a product and to be able to make a homogeneous comparison between products that use different technologies. For products whose transformation efficiency is influenced by external conditions, such as heat pumps, the efficiency data is reported by climatic bands. In addition to the product labels, the European regulation has provided for the creation of a system label in case systems are created with different appliances, components and related controls. This second type of labeling, thanks to the virtuous synergy between the different elements, will make it possible to create systems capable of reaching levels of efficiency even higher than those of the individual appliances. Also starting from the same date, new seasonal efficiency limits will be triggered for products intended for heating and combined. These for products with nominal thermal power equal to or less than 400kW, will prevent less efficient products from being placed on the market. The obligation to comply with minimum heat loss limits will also apply to DHW tanks. For primary water tanks, these will be subject to compliance with an energy classification based on heat dispersion. For sanitary accumulations, up to 500 liters there will be a labeling obligation, from 500 to 2000 liters will be bound to compliance with the energy classification. For heat pumps for heating and mixed appliances, in addition to the seasonal efficiency limits, there will be specific noise emission limits for power sizes. Even water heaters, whether gas, heat pump or solar, in order to be placed on the market, in addition to energy labelling, will have to comply with a series of requirements in terms of efficiency. Warranty All products for sale on our site are new and packed. The guarantee on this item is 24 months from the date of purchase.
€1.534,00
Savio Savio Inoxdens He 35s* Condensing Boiler Complete With LPG Fume Exhaust Kit - New Erp
SAVIO INOXDENS HE 35S* Condensing Boiler Complete With LPG Fume Exhaust Kit - NEW ErP Model: INOXdens HE 35S ErP specifications Class A heating energy efficiency Sanitary energy efficiency Class A Withdrawal profile: XXL Heating/DHW nominal heat input: 29/33.5 kW Heating/DHW maximum useful power 60°/80°C: 28.2/32.5 kW Heating/DHW maximum useful power 30°/50°C: 31/36kW Yield name 60°/80°C: 97.4% Yield at 30% load: 107.4% Energy yield n° **** NOx class 6 Weighted NOx: 47 mg/kWh Minimum/maximum heating temperature: 25/80°C Minimum/maximum heating pressure 3.0/0.3 bar Expansion vessel capacity 7.0 l (total) Minimum/maximum domestic hot water temperature 35/60°C Maximum flow rate (ΔT=25K)/(ΔT=35K): 18.6/13.3 l/min Specific sanitary flow rate (ΔT=30 K): 15.5 l/min Voltage / Power at nominal heat input V~/ W 230/118 Degree of protection IPX5D Dimensions HxWxD 700x400x290; 34.5 kgs Power supply: methane or LPG INOXDENS The perfect compact boiler for underfloor systems and radiator systems The adjustable maximum useful power parameter in heating meets the needs of modern construction without compromising the comfort required in the production of domestic hot water. In fact, this function makes it possible to limit the maximum useful power in heating, independently of the useful DHW power. INOXDENS HE is the new Savio range of wall-mounted condensing boilers: excellent performance thanks to the new heat exchanger and ease of use thanks to the digital control panel with large display. Available in the versions for heating and domestic hot water production and for heating only INOXDENS HE presents a complete range of powers, 20 and 30 kW combi models and 16 KW SV models, in the same extremely compact dimensions (700 x 400 x 290 mm). INOXDENS HE has its strong point in the innovative heat exchanger designed to provide long-lasting high yields digital control panel, designed to communicate with the user in an easy and comfortable way. Like the entire Savio condensing range, INOXDENS HE allows you to obtain maximum savings from climatic thermoregulation, based on the system in which the boiler is installed. High yields (★★★★ compliant with yield directive 92/42 EEC and Legislative Decree 311/06) Sanitary comfort (★★★ EN 13203) Primary condensing exchanger in stainless steel with steel lining to offer maximum resistance to corrosion Total premix burner, built in stainless steel (Class NOx 6) Modulation 1:5 CNG and also LPG Sanitary plate heat exchanger in stainless steel 7 liter expansion tank High efficiency pump with low energy consumption Maximum power adjustable according to the system Degree of protection IPX5D Can be installed in a partially protected place Integration with Savio solar systems, using a solar kit Digital control panel with backlit display Analog pressure reading Arrangement for remote control and external probe. High regulation single coil primary heat exchanger Savio introduces the new stainless steel heat exchanger for condensing boilers to the market: Round. Round is a compact monothermal heat exchanger based on a stainless steel coil with an oval section. The heat exchanger consists of a combustion chamber, condensing area and an insulated metal disc protected with silicone ceramic fiber which separates the two areas. By using a single strip of stainless steel to produce the coil, including inlet/outlet fittings, the following benefits are achieved: Accumulation of dirt and debris is avoided The water flow is uniformly distributed and guarantees a homogeneous heat exchange The water flow is constant for a longer life of the product Reduction of pressure drops with optimized circuit Product Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€996,00