Wall mounted condensing boilers
Ferroli Ferroli Bluehelix Pro 32c LPG Condensing Gas Boiler Complete With Fume Exhaust Kit -Erp
FERROLI BLUEHELIX PRO 32C LPG CONDENSING GAS BOILER COMPLETE WITH FUME EXHAUST KIT -ErP Technical features Energy label specifications according to the European ErP directive Class A heating energy efficiency Sanitary energy efficiency profile XL Class A Characteristics of heating/DHW operation: Thermal input (PCI) Max Heating: 29,5 kW Thermal capacity (PCI) Max Sanitary: 32 kW Thermal power 80°C-60°C Max Heating: 28.9 kW Thermal power 80°C-60°C Max Sanitary: 32 kW Useful thermal efficiency 80°C-60°C: 98% Useful thermal efficiency 50°C-30°C: 106% Domestic hot water production Δt 30°C: 15.3 l/min Domestic hot water production Δt 25°C: 18.3 l/min Energy certification (92/42 EEC): **** Degree of protection: IP X5D Extremely compact dimensions (hxlxp): 600 x 400 x 320 mm; 31kg Power supply: CNG or LPG BLUEHELIX PRO Wall-mounted condensing boilers, premixed sealed chamber with instantaneous sanitary production New series of compact wall-mounted condensing boilers with instantaneous domestic hot water production. Designed to guarantee maximum energy efficiency in heating and in the supply of domestic hot water, thanks to the new patented bivalent exchanger in AISI 316 TI stainless steel. This new exchanger integrates the heating circuit and the production of domestic hot water in a single element, pushing the phenomenon of condensation to the maximum. Built to be installed outdoors in partially protected places and equipped with electronics capable of integrating with a solar panel system. The range: Bluehelix Pro is available in 2 models, both running on methane and LPG. Both the 25C model and the larger size, 32C, offer large volumes of domestic hot water, quickly, which can be further reduced by activating the "Comfort" function Strengths: Primary heat exchanger in thick AISI 316 TI stainless steel with integrated DHW production (dual stainless steel heat exchanger). Patented High yields both in heating and in sanitary production Total premix burner in stainless steel Digital control panel Electronic flame modulation both in heating and DHW Can be combined with the modulating remote timer control Large backlit multifunction graphic display for easy and correct parameter setting Standard by-pass Refined design and compact size Casing painted white by anaphoresis with epoxy powders Advantages : Exchanger with "SELF-CLEANING" function which reduces limescale deposits inside the DHW circuit High yields both in heating and in sanitary production Ease of access to internal components for any maintenance ECO function in DHW for greater savings in the period of low use of hot water Maximum comfort certified 3-star in sanitary manufacturing according to EN 13203 Sliding temperature operation via optional external probe High efficiency modulating heating pump (Erp Ready - Class A) Digital flame control with three re-ignition attempts in the event of malfunction due to lack of flame detection (methane model) Predisposition for solar systems: prepared for the production of domestic hot water combined with solar panel systems Place of installation: also for outdoors in a partially protected place up to -5°C as standard and up to -15°C with the aid of the optional antifreeze heater kit Protection index IPX5D, equivalent to excellent electrical protection of the boiler from liquids and foreign bodies Certified operation also with propane air (50% air - 50% G31) by means of a specific transformation to be requested from the Authorized Assistance Center Appliance belonging to class 5, the most ecological required by European standards (UNI EN 297 NOX and 483) Products that fall under the tax breaks provided for by the Finance Law in force Functions: ECO-COMFORT function: In COMFORT mode, thanks to the particular system for maintaining the temperature of the heat exchanger, the dispensing of domestic hot water becomes even faster and more comfortable. In ECO mode, the production of domestic hot water takes place according to traditional standards. Sliding temperature operation: By installing the “External probe” kit it is possible to operate the boiler in sliding temperature. This means that without using the system temperature adjustment keys, the boiler will self-regulate according to the variations in external temperatures. All this translates into energy savings while ensuring maximum comfort for the user. Antifreeze function: In the event that the temperature in the boiler drops to 5°C, the burner automatically turns on and the circulator is activated in order to protect the appliance from damage caused by freezing. This function is active with the boiler powered by the gas circuit and under electrical voltage. Sun Easy function: BLUEHELIX TECH has been designed to be easily inserted in systems made with the latest technologies. The SUN EASY system, standard on the boiler, makes use of electronics that simplify the combination with both natural and forced circulation solar panels. Through a sensor placed on the DHW circuit, it continuously monitors the temperature of the water coming from the solar panels, foreseeing the ignition of the burner only if the latter drops below the level necessary to guarantee optimal comfort for the user. "SELF-CLEANING" function: Thanks to the "spiral" shape, the passage of domestic water inside the exchanger produces a "centrifugal" self-cleaning effect on the internal walls which tends to remove any limescale deposits. Product Guarantee All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€724,00
CHAFFOTEAUX Gas Boiler Chaffoteaux Alixia Green 25 SA Condensing Eu LPG Complete Kit For Fume Exhaust - New Erp
Overview CHAFFOTEAUX ALIXIA GREEN 25 S LPG EU CONDENSING CONDENSING BOILER COMPLETE WITH FUME EXHAUST KIT -NEW ErP Technical specifications Class A heating energy efficiency Sanitary energy efficiency Class A Withdrawal profiles: XL Features of exercisesHEATING: Energy Category: Condensation Nominal Thermal Output mx/min (Hi): 22 / 5.5 kW Outlet temperature range min/max temp High: 35/85 Cø Outlet temperature ranges min/max temp High: 20/45 Cø Capacity of the expansion vessel: 8 litres Maximum water capacity of the system Features of exercises DOMESTIC HOT WATER: LevelComfort DHW (EN 13203): *** Hot water flow rate at T 25ø: 14.5 l/min Hot water flow rate at T 35ø: 10.4 l/min DHW temperature range: 40/65 Cø EMISSIONS: Minimum suction: 137 Pa Excess air: 27% Nox class (Nox PonderatMg/kWh) G20: 5 ELECTRICAL DATA: Supply Voltage/Frequency V/Hz: 230/50 Max Supply/Gas Pressure: 20 mbar DIMENSIONS AND WEIGHT: Height x Width x Depth mm: 745 x 400 x 307 ; 32 kgs Main features ÿALIXIA GREEN 25 YES The new compact condensing boiler with stainless steel condensing exchanger and prepared for connection to a heating system via the Ebus communication protocol. Can be installed in partially protected places. OperationsolGPL. Sanitary comforts Sanitary heat exchanger in stainless steel. Domestic hot water performance ***, maximum level not foreseen by the EN 13203 standard Flow rate from 14.5 to 19.3 l/min with T = 25 Cø Heating comfort Efficiencyfinal 109% with energy savingsfinal 35%. 4-star combustion efficiency according to the EN 92/42 standard. Modulation wide range, from 25% to 100% of the maximum power. Reduced polluting emissions, NOx class 5. High efficiency circulator with continuous modulation to improve acoustic comfort and reduce energy consumption Differentiated climatic thermoregulation of 2 circuits, according to the room and/or outside temperatureÿ Arrangement for integration into a heating system via the Ebus communication protocol Backlit LCD display with display: history, self-diagnosis, operating temperatures Convenience of installation use Compatible with Expert Control:ÿintuitive system manager for the management of 3 circuits, depending on the ambient and/or outside temperature for greater comfort and greater energy savings Intuitive electrical connections Easier starting: the automatic purge function and directly accessible combustion adjustment Can be installed in partially protected places ENERGY SAVING AND RESPECT FOR THE ENVIRONMENT Final 25% energy savings in combination with Expert Control and the SRA function Final 35% energy savingscombinandExpert Control, SRA function, external probe and radiant floor 40% reduction in CO2 emissions Warranty All products for sale on our site are new and packed. The guarantee on this article is 24 months from the date of purchase.
€715,00
Biasi Gas Boiler Biasi Parva Recover E 28s Condensing Complete With Methane Fume Kit -New Erp
Overview BIASI PARVA RECUPERA E 28S METHANE CONDENSING BOILER - NEW ErP 2015, SEALED CHAMBER COMPLETE WITH FUME EXHAUST KIT: PARVA Recupera E the ErP condensing boiler with heat recovery unit Technical specifications Model:ÿPARVA Recover E 28S Product number:ÿ10313.2027.3 Energy label specifications according to the European ErPÿ directive Class B heating energy efficiency Sanitary energy efficiency Class A Withdrawal profiles: XL Characteristics of heating/sanitary exercises: Thermal input:ÿ29ÿkW Rated useful power: 28.4 kW Nominal load efficiency:ÿ98% Efficiency minimum load:ÿ95.8% Energy efficiency stars: (dir 92/42/EEC) **** Min/max heating temperature: 38/85ÿøC Capacity of the expansion vessel: 6 lt Sanitary flow rate t =25øK l/min: 16.3 l/min Degrees of protection for the electrical system:ÿIPX4D Extremely compact dimensions hxwxd: mmÿ803x400x350ÿ; 49kg METHANE power supply Features list ErP wall-mounted boilers with recuperator Redeveloping an old thermal systemÿ Biasi has designed the ÿPARVA Recupera NOx EÿandÿPARVA Recupera Eÿboilers to replace traditional boilers in old systems. The PARVA Recupera boilers by Biasi are equipped with a corrosion-resistant aluminum alloy fume recovery unit which makes these boilers particularly solid. The recovery unit is made of aluminium, has a finned coil which determines a large exchange surface and is equipped with a device to ensure that the boiler discharges the condensate correctly. The recuperator is treated with a Teflon coating process to ensure maximum durability over time. Thanks to the large exchange surface, the recuperator allows the recovery of thermal energy which would otherwise be dispersed outside through the hot fumes produced by combustion. PARVA Recover E PARVA Recupera E is the condensing boiler designed for traditional systems and easily adaptable to new floor-based systems using MULTIZONE, a hot water distribution system for heating. PARVA It recovers the traditional boiler in the regulations but it has clearly higher efficiency than the traditional boilers at the same operating temperature. As a condensing boiler, PARVA Recupera allows you to take advantage of the tax deduction according to current legislation. Characteristics: High yields (in compliance with yield directive 92/42 EEC and Legislative Decree 311/06ÿ Primary laminated copper heat exchanger with large double circulation exchange surfaceÿ Aluminum heat recovery unit to exploit the heat of the fumes and transfer it to the waterÿ Sanitary plate heat exchanger in INOXÿ steel High efficiency pump with low energy consumptionÿ retractable control panel, with ergonomic knobs and backlit displayÿ Electronic board for:ÿ - Re-ignition frequency adjustmentÿ - Adjustable primary circuit thermal inertia disposalsÿ - Selection of circulator modeÿ - Circulator anti-seizeÿ - Antifreeze safetyÿ - Chimney sweep functionÿ Integrated automatic by-passÿ Immunity to radio interferenceÿ Sanitary flowstat magneticÿ Absolute heating pressure switchÿ Degrees of protection IPX4Dÿ Possibility of integrating PARVA Recupera E with Biasi solar systems using the optional solar kit. Fiscal detraction As a condensing boiler, PARVA Recupera E allows you to take advantage of the tax deduction according to current legislation.ÿÿ Heat recoveryÿ The heat recovery recovers the heat from the fumes before they are expelled and preheats the water directed to the primary exchanger. The recuperator made of aluminum has a finned coil which determines a large exchange surface and has a device to ensure that the boiler discharges the condensate correctly.ÿÿ Thermoregulation By connecting the external probe (optional) directly to the boiler, you can access the climatic adjustment function. The boiler is equipped with a complete set of curves which can be accessed by entering programming. By simply turning a knob you choose the curve, PARVA recovers and will automatically adapt its operation to the external climatic conditions.ÿÿ High circulation primary heat exchangerÿ It is the element that distinguishes the whole PARVA E Biasi range. It favors the flow of water into the heating system and, thanks to its reduced hydraulic resistance, adapts the boiler to the system, facilitating the transmission of heat to the radiators.ÿ Save simplicity of use Parva Recupera retains the simplicity of management, programming and regulation of the traditional boiler and imports the savings of the condensing boiler resulting from the recovery of heat from the fumes. The heat recovery unit preheats the system water with the heat released by the fumes, heat which in traditional boilers is dispersed into the environment. This recovery of energy from the fumes, at operating temperatures typical of radiator systems, leads Parva Recupera to have higher yields than traditional boilers. Low complexity, high comfort Parva Recupera boilers, despite the high technical content, are still very easy to use. Theÿcontrol panelÿhas two knobs dedicated to regulating the temperature of the domestic hot water and the heating water, the key to reset the boiler after the lockout status, the new display to view the boiler operating status and make it easier for the user to understand and installer settings . Fault diagnostics allow immediate verification of correct operation. The manometer allows you to check the system pressure while the temperature is shown on the display. Everything is hidden under a door that defines the sober and linear aesthetics of Parva Recupera. Included in delivery Boiler support bracket and paper templateÿ Condensate collection trapÿ Quick instruction to the user.ÿ All ready for Energy Labeling What is it about From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy intensive sectors: construction For placing on the European market, the directive on ÿeco-designÿ(ErP notcome®ÿEnergy Related Productsÿ¯) imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres As in the household appliances sector, the energy labelingÿof products, with a capacity of less than 70 kW, will give consumers simple, recognizable information which allows them to make comparisonsÿon the performance and energy consumption of the product they wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. It's about me too YES, it affects everyone: professionals and end users The information indicated on the energy labelÿwill allow professionals to recommend the right productÿÿindividuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015, the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. Supplier's liability The company that supplies the product on the market is required to equip its system devices with the following documentation: product energy label;ÿ product data sheet;ÿ system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices;ÿ technical data sheet of the system with the parts relating to the products and the system already completed. Responsibilities of Resellersÿ First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device/system to the public. Therefore, even professionals such as plumbers, installers, designers can fall into this category. All bound to ensure that: all appliances and/systems having their respective labels and making sure they are clearly visible;ÿ all appliances and/systems must always be accompanied by the obligatory technical data sheets;ÿ every type of advertising material, technical promotional material which shows energy data and price indications, contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and the production of hot water will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP): The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL There are different labels depending on the type of appliance. Those with efficiency classes A, A+ and A++ certify products with the highest performance. Furthermore, two different classifications are foreseen for domestic heating and for hot water production services, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the end customer can make his choice in the most aware way possible. SYSTEM LABEL In addition to the product label, the system label is also providedÿin cases where a series of appliances combined with each other is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label so as to inform the end user in the best possible way. Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.019,00
Biasi Gas Boiler Biasi Inovia Cond Plus 30s Condensing Complete With Methane Fume Exhaust Kit - New Erp
NB: PRODUCT TO ORDER FROM DECEMBER Overview BIASI INOVIA COND PLUS 30S CONDENSING METHANE LPG BOILER - NEW ErP, SEALED CHAMBER COMPLETE WITH FUME EXHAUST KIT: Inovia Cond Plus is the new BIASI range of wall-hung condensing boilers with primary and condensing exchanger in stainless steel. Technical specifications Model: Inovia Cond Plus 30S Energy label specifications according to the European ErPÿ directive Class A heating energy efficiency Sanitary energy efficiency Class A Withdrawal profiles: XL Characteristics of heating/sanitary exercises: Heating/DHW maximum useful power: 24.3/29.1ÿkWÿ Heating/DHW nominal heat input: 25/30 kW Yield name 60ø/80øC:ÿ97% Yield at 30% load: 107.1% High yields (in compliance with yield directive 92/42 CEE and Legislative Decree 311/06) Sanitary comfort( EN 13203)ÿ 8 liter expansion tankÿ Degrees of protection IPX5Dÿ Maximum flow rate (T=25 K) / (T=35 K): 16.7/11.9 l/minÿ Specific sanitary flow rate (T=30 K): 13.9 l/minÿ Dimensions hxwxd: mmÿ700 x 400 x 290; 32kg NOx class : 6 ÿMETHANEÿorÿLPG power supply Main features Inovia Cond Plus Wall mounted condensing boilersÿ Inovia Cond Plus is the new BIASI range of wall-mounted condensing boilers: excellent performance thanks to the new heat exchanger and ease of use thanks to the digital control panel with large displays. Available in the versions for heating and domestic hot water production and for heating only, Inovia Cond Plus presents a complete range of powers, 25 and 35 kW combi models and 25 and 35 SV models, in the same extremely compact dimensions (700 x 400 x 290mm). Inovia Cond Plusÿhas its strength in the innovative heat exchangerÿdesigned to provide high yields that last in the digital control panel, designed to communicate with the user in an easy and comfortable way. Like the entire BIASI condensing range, Inovia Cond Plus allows you to obtain maximum savings from climatic thermoregulation, based on the system in which the boiler is installed. High yields (complies with 92/42 EEC yield directive and Legislative Decree 311/06) Sanitary comfort (EN 13203)ÿ Primary and condensing heat exchanger in stainless steel withÿaluminium coatings to offer maximum resistance to corrosionÿ Total premix burner, built in stainless steel (Class NOx5) Sanitary plate heat exchanger in INOXÿ steel High efficiency pump with low energy consumption 8 liter expansion tankÿ Maximum power adjustable according to the systemÿ Degrees of protection IPX5Dÿ Can be installed in a partially protected placeÿ Integration with BIASI solar systems, using a solar kitÿ Innovative digital control panelÿ Digital pressure readoutÿ Arrangement for external probe remote controlÿ Possibility of managing a zone valve by remote control in multi-zone systems. High circulation primary heat exchanger Biasi produces the new Steelcoil compound exchanger with a stainless steel spiral enclosed in an aluminum shell. Thanks to the large exchange surface of the coil, greater thermal efficiency is guaranteed with a lower loss of charge and easier cleaning. The ease of cleaning and the sturdiness of this exchanger are one of the main strengths of the product which can be used on new systems but also on old systems in case of renovations. Steelcoil integrates the round flow function in which the water produces a centrifugal cleaning effect on the internal walls of the monspira. Does the absence of parallel circuits guarantee an easy cleaning operation? of the exchanger and the elimination of any air present in the system circuit. Thermoregulationÿ By connecting the external probe and the remote control (optional) directly to the boiler, climatic regulation can be used. Inovia Cond Plus will adapt the water temperature of the system to the external climatic conditions, guaranteeing the achievement of the desired room temperature without waste and optimizing consumption. By using climatic regulation, the regulation efficiency is also increased, giving greater value to your home. All ready for Energy Labeling What is it about From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy intensive sectors: construction For placing on the European market, the directive on ÿeco-designÿ(ErP notcome®ÿEnergy Related Productsÿ¯) imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres or As in the household appliances sector, the energy labelingÿof products, with a capacity of less than 70 kW, will give consumers simple, recognizable information which allows them to make comparisonsÿon the performance and energy consumption of the product they wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. It's about me tooÿ YES, it affects everyone: professionals and end users The information indicated on the energy labelÿwill allow professionals to recommend the right productÿÿindividuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015, the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. Supplier's responsibility The company that supplies the product on the market is required to equip its system devices with the following documentation: product energy label;ÿ product data sheet;ÿ system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices;ÿ technical data sheet of the system with the parts relating to the products and the system already completed. Responsibilities of Resellersÿ First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device/system to the public. Therefore, even professionals such as plumbers, installers, designers can fall into this category. All bound to ensure that: all appliances and/systems having their respective labels and making sure they are clearly visible;ÿ all appliances and/systems must always be accompanied by the obligatory technical data sheets;ÿ every type of advertising material, technical promotional material which shows energy data and price indications, contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and the production of hot water will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP): The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL There are different labels depending on the type of appliance. Those with efficiency classes A, A+ and A++ certify products with the highest performance. Furthermore, two different classifications are foreseen for domestic heating and for hot water production services, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the end customer can make his choice in the most aware way possible. SYSTEM LABEL In addition to the product label, the system label is also providedÿin cases where a series of appliances combined with each other is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label so as to inform the end user in the best possible way. Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.315,00
Biasi Gas Boiler Biasi Inovia Cond Plus 30s Condensing Complete With LPG Fume Exhaust Kit - New Erp
Overview BIASI INOVIA COND PLUS 30S CONDENSING LPG LPG BOILER - NEW ErP, SEALED CHAMBER COMPLETE WITH FUME EXHAUST KIT: Inovia Cond Plus is the new BIASI range of wall-mounted condensing boilers with primary and condensing exchanger in stainless steel. Technical specifications Model: Inovia Cond Plus 30S Energy label specifications according to the European ErPÿ directive Class A heating energy efficiency Sanitary energy efficiency Class A Withdrawal profiles: XL Characteristics of heating/sanitary exercises: Heating/DHW maximum useful power: 24.3/29.1ÿkWÿ Heating/DHW nominal heat input: 25/30 kW Yield name 60ø/80øC:ÿ97% Yield at 30% load: 107.1% High yields (in compliance with yield directive 92/42 CEE and Legislative Decree 311/06) Sanitary comfort( EN 13203)ÿ 8 liter expansion tankÿ Degrees of protection IPX5Dÿ Maximum flow rate (T=25 K) / (T=35 K): 16.7/11.9 l/minÿ Specific sanitary flow rate (T=30 K): 13.9 l/minÿ Dimensions hxwxd: mmÿ700 x 400 x 290; 32kg NOx class : 6 LPG or LPG fuel supply Main features Inovia Cond Plus Wall mounted condensing boilersÿ Inovia Cond Plus is the new BIASI range of wall-mounted condensing boilers: excellent performance thanks to the new heat exchanger and ease of use thanks to the digital control panel with large displays. Available in the versions for heating and domestic hot water production and for heating only, Inovia Cond Plus presents a complete range of powers, 25 and 35 kW combi models and 25 and 35 SV models, in the same extremely compact dimensions (700 x 400 x 290mm). Inovia Cond Plusÿhas its strength in the innovative heat exchangerÿdesigned to provide high yields that last in the digital control panel, designed to communicate with the user in an easy and comfortable way. Like the entire BIASI condensing range, Inovia Cond Plus allows you to obtain maximum savings from climatic thermoregulation, based on the system in which the boiler is installed. High yields (complies with 92/42 EEC yield directive and Legislative Decree 311/06) Sanitary comfort (EN 13203)ÿ Primary and condensing heat exchanger in stainless steel withÿaluminium coatings to offer maximum resistance to corrosionÿ Total premix burner, built in stainless steel (Class NOx5) Sanitary plate heat exchanger in INOXÿ steel High efficiency pump with low energy consumption 8 liter expansion tankÿ Maximum power adjustable according to the systemÿ Degrees of protection IPX5Dÿ Can be installed in a partially protected placeÿ Integration with BIASI solar systems, using a solar kitÿ Innovative digital control panelÿ Digital pressure readoutÿ Arrangement for external probe remote controlÿ Possibility of managing a zone valve by remote control in multi-zone systems. High circulation primary heat exchanger Biasi produces the new Steelcoil compound exchanger with a stainless steel spiral enclosed in an aluminum shell. Thanks to the large exchange surface of the coil, greater thermal efficiency is guaranteed with a lower loss of charge and easier cleaning. The ease of cleaning and the sturdiness of this exchanger are one of the main strengths of the product which can be used on new systems but also on old systems in case of renovations. Steelcoil integrates the round flow function in which the water produces a centrifugal cleaning effect on the internal walls of the monspira. Does the absence of parallel circuits guarantee an easy cleaning operation? of the exchanger and the elimination of any air present in the system circuit. Thermoregulationÿ By connecting the external probe and the remote control (optional) directly to the boiler, climatic regulation can be used. Inovia Cond Plus will adapt the water temperature of the system to the external climatic conditions, guaranteeing the achievement of the desired room temperature without waste and optimizing consumption. By using climatic regulation, the regulation efficiency is also increased, giving greater value to your home. All ready for Energy Labeling What is it about From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy intensive sectors: construction For placing on the European market, the directive on ÿeco-designÿ(ErP notcome®ÿEnergy Related Productsÿ¯) imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres or As in the household appliances sector, the energy labelingÿof products, with a capacity of less than 70 kW, will give consumers simple, recognizable information which allows them to make comparisonsÿon the performance and energy consumption of the product they wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. It's about me tooÿ YES, it affects everyone: professionals and end users The information indicated on the energy labelÿwill allow professionals to recommend the right productÿÿindividuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015, the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. Supplier's responsibility The company that supplies the product on the market is required to equip its system devices with the following documentation: product energy label;ÿ product data sheet;ÿ system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices;ÿ technical data sheet of the system with the parts relating to the products and the system already completed. Responsibilities of Resellersÿ First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device/system to the public. Therefore, even professionals such as plumbers, installers, designers can fall into this category. All bound to ensure that: all appliances and/systems have their respective labels and make sure they are clearly visible;ÿ all appliances and/systems must always be accompanied by the obligatory technical data sheets;ÿ all types of advertising, promotional and technical materials which show energy data and price indications contain an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and the production of hot water will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP): The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL There are different labels depending on the type of appliance. Those with efficiency classes A, A+ and A++ certify products with the highest performance. Furthermore, two different classifications are foreseen for domestic heating and for hot water production services, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the end customer can make his choice in the most aware way possible. SYSTEM LABEL In addition to the product label, the system label is also providedÿin cases where a series of appliances combined with each other is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label so as to inform the end user in the best possible way. Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.315,00
BERETTA Gas Boiler Beretta Mynute Sinthesi 25 Csi Methane Condensing Complete With Smoke Exhaust Kit New Erp
Energy label specifications according to the European ErP directive Class B heating energy efficiency Sanitary energy efficiency profile XL Class A Characteristics of heating/DHW operation: Nominal heat input: 25 kW Classification European Directive EEC 92/42: **** Quantity of hot water with Δt=25°C: 14 l/min Dimensions (hxlxp) mm 780 x 400 x 336 METHANE power supply Legend: C (heating + sanitary water) S (sealed chamber) I (electronic ignition, ionisation control) Exclusive services: Mynute Sinthesi - ErP Mynute Sinthesi by Beretta is a wall-mounted condensing boiler for high temperature single-family systems. Continuous electronic modulation of the gas antifreeze device as standard (up to 0°C). Environmental Self-Regulation System (SARA). Mynute Sinthesi keeps all the peculiarities of the Mynute range unchanged but evolves towards new needs. The boiler is equipped with a heat recovery unit on the fumes and combustion in a sealed chamber; this makes it possible to obtain very high performance in terms of efficiency and therefore significant energy savings. Mynute Sinthesi therefore represents the ideal solution both in the first installation and in the replacement. Characteristics: ErP boilers with 6 m low consumption circulator (EEI≤0.20) Specific for high temperature systems Condensing post exchanger in aluminum alloy IPX5D electrical protection degree Environmental Self-Regulation System (SARA) Hydraulic connections cover (optional) Template, plumbing fittings, gas and sanitary taps supplied For gas conversion, contact authorized Beretta Technical Assistance Centres Beretta is “ERP”. The concrete commitment towards an eco-sustainable future The acronym ErP, acronym of "Energy related Products" (Products connected to the use of energy), identifies the Directive 2009/125/EC aimed at reducing the energy consumption of products through eco-compatible design. Starting from 26 September 2015 , the date of its effective entry into force in the European Union, it will mark an epochal turning point for heating products and the production of domestic hot water. On that date, other regulations issued at the same time for the energy labeling of products to supplement the corresponding Directive 2010/30/EU will also become effective. The regulation provides that all products intended for heating and for the production of domestic hot water with a nominal thermal power lower than or equal to 70 kW can only be placed on the market with an energy label that highlights the efficiency class * . Different energy efficiency labels have been provided based on the different types of appliances/technologies, but all have the same graduated color scale that identifies the various levels of efficiency at a glance. The purpose of the labels is to give the consumer the possibility to easily identify the level of efficiency of a product and to be able to make a homogeneous comparison between products that use different technologies. For products whose transformation efficiency is influenced by external conditions, such as heat pumps, the efficiency data is reported by climatic bands. In addition to the product labels, the European regulation has provided for the creation of a system label in case systems are created with different appliances, components and related controls. This second type of labeling, thanks to the virtuous synergy between the different elements, will make it possible to create systems capable of reaching levels of efficiency even higher than those of the individual appliances. Also starting from the same date, new seasonal efficiency limits will be triggered for products intended for heating and combined. These for products with nominal thermal power equal to or less than 400kW, will prevent less efficient products from being placed on the market. The obligation to comply with minimum heat loss limits will also apply to DHW tanks. For primary water tanks, these will be subject to compliance with an energy classification based on heat dispersion. For sanitary accumulations, up to 500 liters there will be a labeling obligation, from 500 to 2000 liters will be bound to compliance with the energy classification. For heat pumps for heating and mixed appliances, in addition to the seasonal efficiency limits, there will be specific noise emission limits for power sizes. Even water heaters, whether gas, heat pump or solar, in order to be placed on the market, in addition to energy labelling, will have to comply with a series of requirements in terms of efficiency. Warranty All products for sale on our site are new and packed. The guarantee on this article is 24 months from the date of purchase.
€927,00
Riello Riello Replexa 32 Kis Condensing Boiler Complete With Low Nox Methane Fume Exhaust Kit - New
Riello Replexa 32 kis condensing boiler complete with methane low NOx fume exhaust kit - NEW Energy class in heating A Energy class in sanitary A XL load profile Heating nominal heat input kW 29.00 DHW nominal heat input kW 31.60 Useful efficiency (80°-60°) pn max. - pn min. % 96.9 - 97.4 Supply voltage V - Hz 230-50 IP X5D degree of protection Maximum heating pressure bar 3 Expansion vessel l 8 Maximum pressure bar 8 Hot water production with t+25 °cl/min 18.1 Dimensions (H×W×D) mm 740X420X275 Replexa Compact, reliable and versatile, REPLEXA is the ideal boiler for carefree replacement. Specially designed by Riello for quick and easy installation, REPLEXA comes with a wide range of accessories that allow it to be placed both inside the home, outside (in partially protected places) and recessed (KIS models). . Equipped with DIN standard hydraulic connections, REPLEXA is the right answer for those who want to replace their old boiler with a Riello model. The new range, thanks to the modern and essential aesthetics, in line with the new generation Riello products, integrates easily into any living environment, even in new buildings. So many features and pluses of Replexa, all to be discovered, which will soon be appreciated by both the user and the installer. TECHNOLOGICAL AND RELIABLE RIELLO REPLEXA IS CANDIDATE TO REPRESENT A NEW REFERENCE IN THE REPLACEMENT SEGMENT The new range guarantees low consumption and good energy efficiency, reaching class A, both in heating and DHW. A vast range of accessories makes REPLEXA the ideal choice in case of replacement, responding to the various installation needs. Ease of use and installation, together with the reliability that has always characterized the Riello offer, complete the profile of REPLEXA, which will soon be appreciated on the market by both users and installers. LOW NOX EMISSIONS: CLASS 6 (UNI EN 15502) MODULATION RANGE 1 : 5 ALUMINUM CONDENSING EXCHANGER 8 LT EXPANSION TANK, SIDE INCREASED PLATE EXCHANGER, FOR EXCELLENT SANITARY COMFORT MODELS 25 KIS - 25 IS C10 APPROVED. FUME CLAP (NON-RETURN VALVE) AVAILABLE AS AN ACCESSORY ELECTRICAL PROTECTION DEGREE IPX5D COMPATIBLE WITH AIR-PROPANE GAS (25 KIS AND 25 IS MODELS) AND LPG, THROUGH OPTIONAL KITS Product Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase
€1.035,00
Riello Riello Family Externa Condens 3.0 Kis LPG Condensing Boiler Complete With Smoke Kit - New Erp
RIELLO FAMILY EXTERNA CONDENS 3.0 KIS LPG CONDENSING BOILER COMPLETE WITH FUME KIT - NEW ErP Technical features Product code: 20102940 Energy label specifications according to the European ErP directive Class A heating energy efficiency Sanitary energy efficiency profile XL Class A Characteristics of heating/DHW operation: Furnace thermal power (heating) min-max: 3.2÷25 kW Useful thermal power (sanitary) min-max: 3.2÷30 kW Energy efficiency (92/42/EEC) **** Useful efficiency at Pn* (50°C-30°C): 106.8% Profit return 30% (47th return): 107.9% Sealed chamber, forced draught Quantity of hot water with Δt 25°C: 17.2 l/min Minimum domestic water flow rate: 2 l/min Dimensions (hxlxp) mm 1002 x 475 x 311 ; 50 Kgs Electrical protection degree: IP X5D NOx class: 5 Power supply: METHANE Family Remote Control, supplied as standard FAMILY EXTERNAL CONDENS Yield **** Low polluting emissions Aluminum condenser, with premix burner Models for combined instantaneous and storage heating For outdoor installations in the open Family Externa Condens is an outdoor wall-mounted boiler that can be installed totally in the open. The new primary heat exchanger completely made of aluminum with front access to the combustion chamber ensures better efficiency and durability. It is available with powers from 3.2 to 30 kW. Characteristics: Modulation ratio 1:10 (minimum power 3.2 kW) which allows the boiler to respond to all heat requests Modulating circulator, low consumption (IEE≤0.20) 3 Stars in sanitary comfort according to EN 13203 Family Remote Control, supplied as standard, allows management of all boiler functions directly from inside the home Antifreeze up to -15°C Remote alarm system that allows remote signaling of the boiler lockout status Special Family functions: Wellness key, Memory key, Touch&Go function, Intelligent system filling Standard external probe. The FAMILY Remote Control kit (remote control panel) is the tool that allows you to manage the boiler remotely. The panel monitors the boiler, storage tank and room temperatures, monitors and supervises the operating regimes, the activation times and signals any anomalies. The remote control panel can be configured as: Chronothermostat (factory confi guration): it will work according to the standard heating program or according to the personalized one. In this configuration the control panel tries to keep the room at two temperature levels (comfort and reduced), passing from one to the other at times established by the user. Thermostat: heating is activated when the temperature detected by the room probe (contained in the control panel) is lower than the one set, regardless of the memorized heating program. Product Guarantee All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.659,00
Riello Riello Family Condens 3.0 Kis Methane Condensing Boiler Complete With Smoke Kit - New Erp
Overview RIELLO FAMILY CONDENS 3.0 KIS METHANE CONDENSING BOILER COMPLETE WITH FUME KIT - NEW ErP 2015: Family Condens is a technologically advanced wall-mounted boiler that combines the best comfort, energy savings and respect for the environment. Technical specifications Product code:ÿ20102936 Energy label specifications according to the European ErP directive Class A heating energy efficiency Sanitaryware energy efficiencyprofilXL Class A Characteristics of heating/sanitary exercises: Fireplace thermal power (heating)ÿmin-max: 3.2ú25.0ÿkW Useful thermal power (sanitary) min-max: 3.2ú30.0ÿkW Energy efficiency(92/42/CEE)ÿ**** Efficiency at Pn* (50øC-30øC): 106.8% Profitability 30% (47ø return): 109.9% Sealed chamber, forced draft Quantity of hot water at t 25°C: 17.2 l/min Minimum domestic water flow rate: 2ÿl/min Dimensions (hxwxd) mmÿ845 x 453 x 358ÿ; 43 kgs Electrical protection degrees: IP X5D NOx class: 5 Power supply: METHANEÿ Features list FAMILY CONDENS Efficiency****ÿ Low polluting emissionsÿ Aluminum condenser, with premix burnerÿ Models for combined instantaneous and storage heating For indoor and outdoor recessed installations Family Condens a wall-mounted boiler that combines comfort, energy saving and respect for the environment with the best. The new primary heat exchanger completely made of aluminum with front access to the combustion chamber (models 2.5 and 3.0) guarantees better efficiency and duration. Family Condens available with powers from 2.8 to 35 kW. Features:ÿ Modulation ratio 1:10 (minimum power 2.8 kW) which allows the boiler to respond to all heat requestsÿ Modulating circulator, low consumption(IEE0,20)ÿ 3 Stars in sanitary comfort according to EN 13203ÿ Remote alarm system which allows remote signaling of the boiler lockout statusÿ Special Family functions: Wellness Tast, Memory Tast, Touch&Go function, Intelligent system fillsÿ Assembly template, hydraulic fittings and electric power cable suppliedÿ LPG conversion kit (G31) supplied for 3.5ÿ models Standard external probe ÿInstallation Benefits Performance secondDir. 92/42/EEC. Circulator lowconsum(IEE0,20) Climatic adjustment managed directly by the boiler control unitÿ Special Family functions: TastBenessere, TastMemory, Touch&Go function Smart Fillsÿ Assembly template, hydraulic fittings, power supply cable supplied ErP: Energy related Products ErP the acronym for Energy related Products? (products connected to the use of energy) and the abbreviation that identifies the European Directive ErP 2009/125/EC, defined by the EEC with the intention of reducing the energy consumption of products through eco-compatible design (or eco-design?). The scope of action of this European Directive is extremely broad since up to now it has affected products such as light bulbs, air conditioners, washing machines, fans, etc. Following the publication in September 2013 of a series of implementing regulations, starting from 26 September 2015 they will also apply to heating products and the production of domestic hot water. Also from the same date, other regulations will also become effective which will implement the energy labeling of the same product families. The transitional period between the publication of the regulations and their activation throughout the territory of the European Community is necessary to allow the full transposition of the contents by companies and market players. The regulations issued require that all products intended for heating and/for the production of domestic hot water, with a nominal thermal power lower than or equal to 70 kW, are placed on the market with an ÿenergy labelÿ that highlights their efficiency class. Note: the regulation provides for the mandatory presence of the energy label for the introduction of the product from the factories to the market. All the products previously introduced, for example present near distribution warehouses, can be regularly marketed even if they do not have an energy label. Various energy labels have been provided based on the use of the generator used: for heating from A++ to G; for the production of domestic hot water from A to G. The purpose of energy labels is to allow the consumer to easily identify the level of efficiency of a product, to be able to make a homogeneous comparison between products that use different technologies. For products whose transformation efficiency is influenced by external conditions, such as heat pump products, as well as those on air conditioners, the efficiency data reported for the average climatic zone. In addition to product energy labels, European regulations have also provided for the creation of a "system label" in the case of building a plant in which various appliances, components and controls operate. This labelling, thanks to the combinations of the data of the various elements used in the plant, will allow the creation of systems capable of reaching levels of efficiency even higher than those of the individual generators. The European regulation states that the system label must be made available by whoever supplies and/operates the system (sellers-installers); but this faculty is also granted to builders. Warranty All products for sale on our site are new and packed. The guarantee on this article is 24 months from the date of purchase.
€1.424,00
Riello Riello Family Condens 2.5 Kis Methane Condensing Boiler Complete With Smoke Kit - New Erp
RIELLO FAMILY CONDENS 2.5 KIS METHANE CONDENSING BOILER COMPLETE WITH SMOKE KIT - NEW ErP 2015: Family Condens is a technologically advanced wall-mounted boiler that combines the best comfort, energy savings and respect for the environment. Technical Features Product Code: 20102932 Energy label specifications according to European ErP directive Heating energy efficiency Class A Energy efficiency of sanitary equipment XL profile Class A Heating/sanitary operation features: Fireplace thermal power (heating) min-max: 2.8÷20.0 kW Useful thermal power (domestic hot water) min-max: 2.8÷25.0 kW Energy efficiency (92/42/EEC) **** Useful efficiency at Pn* (50°C-30°C): 107.2% Profitability 30% (47th return): 109.6% Airtight chamber, forced draft Amount of hot water at Δt 25°C: 14.3 l/min Minimum flow rate of sanitary water: 2 l/min Dimensions (hxwxd) 845 x 453 x 358 mm; 42 kg Electrical protection degree: IP X5D NOx class: 5 Power supply: METHANE General Features FAMILY CONDENS Performance **** Low polluting emissions Condensation in aluminum, with premixed burner Combined instantaneous and storage heating models For indoor, outdoor and built-in installations Family Condens is a wall-mounted boiler that best combines comfort, energy saving and respect for the environment. The new primary heat exchanger made entirely of aluminum with frontal accessibility to the combustion chamber (models 2.5 and 3.0) guarantees better efficiency and durability. Family Condens is available with powers from 2.8 to 35 kW. Characteristics: Modulation ratio 1:10 (minimum power 2.8 kW) which allows the boiler to respond to all heat requests Modulating circulator, low consumption (IEE≤0.20) 3 Stars in health comfort according to EN 13203 Alarm remote control system that allows remote reporting of boiler block status Special Family functions: Wellness button, Memory button, Touch&Go function, Intelligent system filling Assembly template, hydraulic fittings and power cable included LPG conversion kit (G31) supplied with 3.5 models External probe as standard. ErP: Energy related Products The new European regulations for heat generators ErP is the acronym for “ Energy related Products ” (energy-related products) and is the abbreviation that identifies the European ErP Directive 2009/125/CE, defined by the EEC with the aim of reducing the energy consumption of products through eco-compatible design (“eco-design”). The scope of this European Directive is extremely broad as it has so far affected products such as light bulbs, air conditioners, washing machines, fans, etc. Following the publication in September 2013 of a series of implementing regulations, from 26 September 2015 it will also apply to heating and domestic hot water production products. Also from the same date, other regulations that will implement the energy labeling of the same product families will become effective. The transitional period between the publication of the regulations and their activation throughout the European Community was necessary to allow the full reception of the contents by companies and market players. Energy labelling of heating and domestic hot water products The regulations issued require that all products intended for heating and/or the production of sanitary water, with a nominal thermal power lower than or equal to 70 kW, be placed on the market with an energy label that highlights their efficiency class. Note: the regulation requires the presence of the energy label for the release of the product from factories to the market. All products previously released, for example present in distribution warehouses, can be regularly marketed even if they do not have an energy label. Different energy labels have been provided based on the use of the generator used: for heating from A++ to G; for the production of sanitary water from A to G. A new way to guide the consumer The purpose of energy labels is to allow the consumer to easily identify the efficiency level of a product and to be able to make a homogeneous comparison between products that use different technologies. For products whose transformation efficiency is influenced by external conditions, such as heat pump products, as has been done for air conditioners, the efficiency data is reported for the average climate range. In addition to product energy labels, European regulations have also provided for the creation of a system label in the case of a system in which several devices, components and controls operate. This labeling, thanks to the combinations of data from the different elements used in the system, will allow the creation of systems capable of reaching efficiency levels even higher than those of individual generators. The European regulation requires that the system label must be made available by those who supply and/or operate the system (sellers-installers); however, this option is also granted to manufacturers. Product Warranty All products for sale on our site are new and packaged. The warranty on this item is 24 months from the date of purchase.
€1.401,00
Ferroli Ferroli Condensing Boiler Heating Only Bluehelix Tech 25 Natural Gas Or LPG Complete With Fumes Kit - New Erp
FERROLI CONDENSING BOILER FOR HEATING ONLY BLUEHELIX TECH 25 METHANE OR LPG COMPLETE WITH FUME KIT - NEW ERP Product name: FERROLI CONDENSING BOILER FOR HEATING ONLY BLUEHELIX TECH 25 A - NEW ErP Technical features Seasonal space heating energy efficiency class A Space heating energy efficiency ηs % 94 Heat input (PCI) Min / Max Heating: 5.8 - 25 kW Thermal power 80°C-60°C: 5.7/24.5 kW Useful thermal efficiency 80°C-60°C Pmax % / Pmin %: 98.0/97.8 Heating working pressure Max bar 3 Empty weight kg 28 Dimensions HxWxD: 600 x 400 x 320mm Power supply: METHANE Certified operation also with LPG using a special kit to be requested from the Authorized Assistance Centre Heating only model (A) equipped with diverter valve and set up for combination with a boiler (except 45 H) Appliance suitable for operation in a partially protected place down to -5°C as standard and down to -15°C with the aid of the optional antifreeze heater kit (excluding mod. 45 H) Remote control of boiler parameters via ROMEO remote control (optional) Appliance operating in climatic regulation with sliding system temperature (optional external temperature probe) Products that fall under the tax breaks provided for by the Finance Law in force BLUEHELIX TECH A The range of generators is equipped with the new AISI 316 TI stainless steel exchanger. Designed and built according to the new ErP directives for eco-compatible design and labelling, Bluehelix Tech is at the top of its category. Bluehelix Tech achieves one of the highest energy efficiency of the space heating in its category: ηs 94%. Furthermore, when combined with the external probe and the Romeo remote timer control, it reaches system energy class A+ (mod.18A/45H excluded). Strengths: It achieves one of the highest seasonal space heating efficiency in its category: ηs 94% (mod. 25/35 only) System energy class A+: in combination with the Romeo modulating remote timer control and the external probe (mod.25/35 only) Boiler body with primary heat exchanger in thick stainless steel AISI 316 Ti Domestic hot water production in combination with boiler (optional), standard 3-way valve in the boiler (excluding mod. 45 H) Total premix burner in stainless steel Digital control panel Electronic flame modulation both in heating and DHW Can be combined with the modulating remote timer control Large backlit multifunction graphic display for easy and correct parameter setting Standard by-pass Refined design and compact size Casing painted white by anaphoresis with epoxy powders Advantages: Sliding temperature operation in combination with the optional external probe ECO function in DHW for greater savings in the period of low use of hot water Low consumption modulating heating pump (Erp Ready - Class A) Digital flame control with three re-ignition attempts in the event of malfunction due to lack of flame detection (only in methane operation) Place of installation: also for outdoors in a partially protected place down to -5°C as standard and down to -15°C with the aid of the optional antifreeze heater kit (excluding mod. 45 H) Certified operation also with propane air (50% air - 50% G31) by means of a specific transformation to be requested from the Authorized Assistance Center (max total price of 30 euros + VAT) Also works on LPG with the use of a special conversion kit to be requested from the Authorized Assistance Centre. Free transformation during product verification and activation of the guarantee only if the specific code running on LPG is not available. Tangible Facts: max consumption standard non-modulating circulator: 0.085 kW max consumption new high efficiency circulator: 0.04 kW Degree days 2500 (average climate zone E) Energy cost: €0.19/kWh Hypothetical annual expenditure at max standard circulator speed: €40.375 Hypothetical annual expenditure max speed high efficiency circulator: 19 € Therefore, with the replacement of standard boilers with Bluehelix, in line with the new ERP regulations, electricity savings of around 30% can be estimated. In reality, the savings will be even greater, since these are modulating circulators, which at minimum power can reach consumption of up to just 3 W. ..SELF ADAPTIVE The low-consumption circulator installed in the Bluehelix K 50 has a variable flow rate, with ΔT control. The advantages o ered are many, including: System start-up from cold: faster start-up with full control of the thermal load on the components Long-lasting maintenance of the temperature equilibrium conditions, once the set point has been reached Better operation in extreme conditions (e.g. at minimum power), reduction of on-OFF states Reactivity to variations in the thermal load, an appreciable quality in multi-zone systems ..ROBUST Others are the merits attributable to the circulator chosen for Bluehelix: The PWM signal (pulse width modulation) to the circulator allows extremely rapid intervention times to complete an advanced and complete electronic platform. This results in a drastic reduction of the ON-OFF events of the burner and the circulator. Electronic control of the drive torque at start up with consequent reduction of the risk of blocking. The routine anti-seize cycle is in any case carried out every 24 hours of inactivity. Self-protection function in case of overheating Less noise All this translates into greater longevity not only of the circulator, but also of the components subject to wear and tear from frequent on-off cycles. Product Guarantee All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€711,00
BERETTA Beretta Exclusive Green E 25 Csi Condensing Boiler Complete With Fume Exhaust Kit Cod. 20104060 Methane
Beretta EXCLUSIVE GREEN E 25 CSI condensing boiler complete with flue kit cod. 20104060 Class A heating energy efficiency Sanitary energy efficiency profile XL Class A Characteristics of heating/DHW operation: Heating nominal heat input: 20 kW Heating nominal heat output: 21.44 kW Classification European Directive EEC 92/42: ★ ★ ★ ★ Sanitary comfort ★ ★ ★ (EN 13203) NOx emission class: 5 (UNI EN 677) Efficiency at rated power: 98.7% Efficiency at reduced load (30%): 109.6% Total electric power: 93W Electrical protection degree: iP X5D Expansion tank capacity: 9 lt Quantity of hot water with Δt=25°C: 14.3 l/min Minimum domestic water flow rate: 2 l/min Sanitary water temperature selection range: 35 - 60°C Dimensions (hxlxp) mm 845x453x358 ; 44kg METHANE power supply Legend: C (heating + sanitary water) S (sealed chamber) I (electronic ignition, ionization control). EXCLUSIVE GREEN E HI-EFFICIENCY ECOLOGICAL CONDENSING WALL-MOUNTS The new Exclusive Green E condensing boilers , equipped with the innovative Beretta front exchanger, in addition to implementing the requests of the ErP standards, improve all the peculiarities confirming themselves as top of the range. Seasonal efficiency up to 94%, very wide modulation range (up to 1:10), low consumption modulating circulator with the possibility of increasing the head up to 7m and reduced consumption are some of the main features. The new Exclusive Green E boilers also offer excellent reliability and technology and, thanks to their high performance, are an excellent solution in hybrid systems with solar thermal and heat pumps. The external probe that allows you to activate the climatic thermoregulation is standard as standard. Furthermore, by adding the optional BeSMART WiFi Comfort Control kit and the LINK MODE interface board kit, Exclusive Green E constitutes a class A+ system and home comfort can be governed by remotely via APP for smartphones and tablets. The boilers are equipped with a special high-head fan designed to be able to pipe flues with Ø 60 mm or Ø 50 mm flues. Front access condensing heat exchanger ( New ! ) The Exclusive Green E boiler is equipped with the new Beretta condensing exchanger with front access . An innovative system of guides allows it to move like a drawer, making disassembly for cleaning required by current regulations much faster. Continuous research has allowed Beretta to obtain an exchanger characterized by a considerable increase in performance: 94% average seasonal efficiency calculated according to the European ErP Directive. The exchanger comes from a single aluminum tube, without welding thanks to an innovative production process. The high thermal conductivity of aluminium, much higher than that of steel, allows for greater uniformity in temperature distribution. The single pipe architecture (series circuit) allows for a large section for the passage of water with the advantage of reducing pressure drops and preventing the deposit of impurities, keeping the exchanger performing over time. Modulation 1:10 The range offers a wide range of modulation to respond to real energy needs, while simultaneously offering a high reduction in consumption. Beretta realizes this system through a totally pneumatic and therefore safe and reliable model. The electronics in fact act only on the number of fan revolutions (inlet air flow rate) without intervening on the injection of the gas quantity which is automatically sucked in. Beretta therefore introduces a new double distribution mixer: a mechanical damper with a calibrated weight which opens or closes a part of the section of the venturi so as to divide the modulation range into two stages (smaller section with low air flow rates or larger section with high air flow rates). Beretta has also developed a specific silencer in the air intake to reduce any resonances generated by the new mixer. Up to 19 m of ducting with Exclusive Green E 25 With Exclusive Green E it is possible to duct even the most "difficult" flues with ease thanks to the approval for Ø 50mm flues which is added to the traditional Ø 80 mm and Ø 60 mm ducting flues. The main 50mm flue ducts are available in the Beretta price list catalogue, while the boiler manuals provide indications of the maximum length, which differ according to the boiler power. Flex modulating circulator, optimized performance, low consumption ( New ! ) Exclusive Green E uses a low energy consumption synchronous modulating circulator with an Energy Efficiency Index of less than 0.20, which means significantly reduced electricity consumption. The new circulator is set as standard to modulate proportionally to the power supplied by the boiler, thus contributing to a further reduction in electricity consumption. Alternatively, it can modulate with a constant ΔT logic in order to maximize the phenomenon of condensation in the exchanger. If necessary on the heating system, it is also possible to modify the maximum head which is normally set on the 6 m curve, opting for the 4 m, 5 m or 6 m curve without having to replace the circulator, from this characteristic comes the name "Flex". Smart management The control panel is the boiler management device. Simple and intuitive, it allows you to adjust the parameters and activate the numerous functions. A large liquid crystal display shows all important information. By turning the knobs, the heating water and domestic hot water temperature can be set easily and intuitively. The simple pressure of a key allows you to choose the season and, when the boiler asks for it, the Easy Filling function is activated by pressing a key. The panel integrates the Clima Facile function: thermoregulation and external probe as standard. Compatible with BE Smart ( New ! ) The BeSMART WiFi Comfort Control Panel, optional compatible with Exclusive Green E, is the remote boiler management device with modulating chronothermostat functions. With the WiFi Box accessory, included in the BeSMART WiFi Comfort Control, it is also possible to manage comfort remotely using Smartphones and Tablets. The BeSMART WiFi control is very simple to install and intuitive to use and allows you to adjust the parameters and activate the many functions on the boiler. A large liquid crystal display shows all important information. Using the buttons on the control, the temperature of the heating water and domestic hot water is set easily and intuitively and the heating time programming is carried out. Exclusive Green E and the optional BeSMART WiFi Comfort Control Kits and LINK MODE interface card form a class A+ system. Characteristics: Exclusive Green E* with the BeSMART WiFi Comfort Control (optional) or with the REC 07 Remote Control (optional) forms a class A+ system Compatible with the BeSMART WiFi Comfort Control for remote control via iOS or Android APP from Smartphone or Tablet Very high modulation (up to 1:10) New high-flow aluminum condensing exchanger with front access Low polluting emissions: class 5 (UNI EN 483) Low consumption modulating circulator (EEI≤0.20) 6 m head adjustable up to 7 m Thermoregulation with standard external probe Standard hydraulic fitting cover Possibility of intubating flues with the special flue in PP ø 60 (up to 23m) and ø 50 (up to 19m)** Template, plumbing fittings, gas and sanitary taps supplied For gas conversion, contact authorized Beretta Technical Assistance Centres *except model 35E **model 25E Warranty All products for sale on our site are new and packed. The guarantee on this item is 24 months from the date of purchase.
€1.624,00