Wall Boilers
Ariston Ariston Condensing Boiler Genus One Net 24 Kw Methane/LPG Complete With Fume Exhaust Kit Split Fume Kit, LPG
Technical features Product code: 3301113 Energy class in heating: A; Energy class in sanitary: A; Profile: XL; Forced draft sealed chamber; Dimensions (HxWxD) 745x400x315 mm; Weight: 32.7kg; Energy data: Nominal heat flow in heating (max/min): 22.0/2.5 kw; Nominal heat input in DHW (max/min): 26.0/2.5 kw; Thermal power (max/min) from 80° C- 60° C: 21,5/2,3 kw; Thermal power (max/min) from 50° C- 30° C: 23.6/2.6 kW; DHW thermal power (max/min): 24.9/2.4 kW Combustion efficiency (flue gas) 97.4% Efficiency at nominal heat input from 60/80° C: 97.7% Efficiency at nominal heat input from 30/50° C: 107.4% Performance Stars: 4**** Expansion tank pressure: 1 bar; Max pressure: 3 bar; Expansion tank capacity 8 l; High temperature range (min.max): 35/82 °C; Low temperature range (min/max): 20/45 °C; Exercise performance in healthcare: Min/max domestic hot water temperature: 36/60 °C Specific flow rate (10 min. with ?T=30°C): 12.8 litres/min; Quantity of hot water ?T=25°C: 15.4 litres/min; Quantity of hot water ?T=35°C: 11.0 litres/min; Comfort performance stars (EN13203) ??? Supply voltage/frequency V/Hz 230 / 50 Minimum ambient temperature of use: >0°C; Absorption: 80W; Electrical protection: IP X5D; Drain: 80, 60, 50 mm; Power supply: LPG/METHANE (G20, NG); General characteristics New generation Ariston condensing boiler, it is the perfect mix of innovation and maximum comfort at your fingertips, in fact by connecting the appliance (also thanks to the Cube S NET, the room thermostat with integrated connectivity) to your smartphone or tablet via the appropriate downloadable app for both IOS or Android, the efficiency of the boiler connected to your smartphone give the maximum desired comfort. Installation in partially protected places or with suitable boiler covers is recommended due to the need for outdoor installation to better protect the appliance. Equipped with a large Dsplay with backlit touch interface to view correct operation and regulation or in the event of boiler malfunction for rapid intervention by authorized personnel. To always have domestic hot water ready, the Genus One Net boiler works with a high-efficiency circulator with continuous modulation (ratio 1:10) so as to respond quickly to the user's needs. Finally, the boiler is extremely silent, guaranteeing minimum acoustic disturbance, guaranteeing fewer cycles on and off the boiler and a new silencer and sound-absorbing panels that allow minimum noise. Advantages: Prepared for integration into system configuration Through the new Bus Bridgenet® communication protocol; Arrangement for multi-zone and multi-temperature thermoregulation; Arrangement for solar system management; Functions: Car and comfort function; Isothermal primary heat exchanger in stainless steel; Increased DHW exchanger; Ignition system; electronic combustion control; Gas transformation from the technical menu; Cold water inlet and heating return filters;
€1.300,00
BERETTA Beretta Boiler Open Chamber Meteo 24 Cai Lx Low Nox With Standard Besmart Cod. 20152461 Methane - New
ATTENTION THIS PRODUCT IS MADE TO ORDER. WILL BE SHIPPED WITHIN 10 DAYS OF PURCHASE DATE Cadaia Beretta Open Chamber Meteo 24 cai LX Low NOx with Standard BeSmart cod. 20152461 Methane - New Heating/sanitary nominal heat input Kw 26.7 Heating/DHW nominal heat output kW 24.06 Heating reduced heat input kW 10.7 Heating reduced thermal power kW 9.33 DHW reduced heat input kW 9 DHW reduced thermal power kW 7.85 Useful efficiency Pn max - Pn min (80°-60°) % 90.1 - 87.2 Profitability 30% (50th return) % 89.5 Combustion efficiency % 91.6 Total electric power W 87 Circulator electric power (1,000 l/h) W 39 Category II2H3P Destination country IT Supply voltage V - Hz 230 - 50 IP X5D degree of protection Chimney losses with burner off - on % 0.37 - 8.40 Warm-up exercise Maximum pressure bar 3 Minimum pressure for operation 0.25 - 0.45 bar Maximum temperature 90 °C Heating water temperature selection range °C 40 - 80 Membrane expansion vessel l 8 Expansion vessel preload bar 1 Sanitary exercise Maximum pressure 6 bar Minimum pressure bar 0.15 Quantity of hot water at ?t 25° C l/min 13.8 Minimum domestic water flow rate l/min 2 Domestic hot water temperature selection range °C 37 - 60 Flow regulator l/min 10 Gas pressure Natural gas nominal pressure (G20) mbar 20 LPG (G31) liquid gas nominal pressure mbar 37 Hydraulic connections Heating inlet - outlet Ø 3/4” DHW inlet - outlet Ø 1/2” Gas inlet Ø 3/4” Boiler dimensions Height mm 760 Height with coverage 886 Width 494mm Depth 243mm Weight kg 34 LX WEATHER New boilers with Low NOx emissions Low consumption circulator (EEI≤0.20) modifiable up to 7 m head Built with specific materials for outdoor use BeSMART remote control panel as standard Standard antifreeze up to -15 °C IPX4D electrical protection degree Arrangement for climatic thermoregulation Plumbing fittings, gas and sanitary taps supplied For gas conversion, contact authorized Beretta Technical Assistance Centres Product Warranty The warranty on this item is 24 months from the date of purchase.
€1.289,00
Ferroli Open Chamber Boiler Ferroli Divaproject C24 LPG
Also works on LPG with the use of a special conversion kit to be requested from the Authorized Assistance Centre. Free transformation during product verification and activation of the guarantee only if the specific code running on LPG is not available In case of unavailability, the new DIVATECH D LNC 24 model will be supplied Technical features Model : Divaproject C24 Power supply: LPG Performance Energy efficiency class in heating: C DHW energy efficiency class: A Heating nominal heat output : 7.0 ~ 23.5 kW Heat output : 8.3 ~ 25.8 kW Domestic useful thermal power: 23.5 kW Efficiency : 91 % Maximum production of domestic hot water Δt 25°C : 13.4 l/min Maximum production of domestic hot water Δt 30°C : 11.2 l/min Dimensions and weight Dimensions (HxWxD): 700x400x330 mm Empty weight: 27.0 kg Ferroli Divaproject Boiler Wall mounted boilers with instantaneous DHW production with double exchanger, open chamber, natural draft The Divaproject c24 by Ferroli is the cheapest solution for replacing open chamber boilers. Built to be installed outdoors in partially protected places and prepared for integration with a solar panel system. It has an excellent value for money and is entirely Made in Italy with a 2-year guarantee . The cheapest in its category Arrangement for solar systems Eco-comfort system for rapid domestic hot water production High efficiency low consumption circulator (class A) Ideal for residential homes up to 120 m2 2 Year Warranty Divaproject is a heat generator for heating and instant domestic hot water production. The series has been designed in each of its components to have top performance in its category while maintaining characteristics of simplicity and compactness. The control electronics allow for easy and functional combination with solar collector systems. The series includes two models: C24 and C30 The boiler is designed to operate on natural gas and LPG or even on propane air by means of a special transformation. The efficiency of Divaproject is the maximum for its category, certified at 3 stars according to the 92/42 EEC Directive for energy classification Components Expansion tank Combustion chamber Copper primary exchanger Atmospheric burner Sanitary exchanger Modulating gas valve Motorized 3-way valve Boiler control Control panel and functions Divaproject's control and management electronics allow the user to customize the operation of the appliance in order to manage environmental comfort according to one's needs. The control panel with the adjustment knobs makes the programming operations for the production of hot water, both for domestic hot water and for heating, extremely easy and intuitive Remote control "ROMEO" timer Divaproject boilers can be combined with a wide range of remote timer controls which allow the appliance to be adjusted and operated remotely. The ROMEO series consists of 4 models, respectively with weekly or daily comfort programming and with the possibility of choosing between wired or wireless connection for both With ROMEO you can: Adjust the heating and DHW temperatures Know the operating status of the boiler View the temperatures inside and outside the house Restart the boiler in case of temporary lockout Program the daily or weekly environmental comfort Activate/deactivate the heating function via the telephone The ROMEO modulating function allows boiler output to be modulated as the set room temperature value is reached. This improves the quality of comfort by eliminating heat peaks with consequent energy savings. With solar systems Sun Easy function Divaproject boilers have been designed to be easily inserted in systems made with the most recent technologies. The SUN EASY system, standard on the boiler, makes use of electronics that simplify the combination with both natural and forced circulation solar panels. Through a sensor placed on the DHW circuit, it continuously controls the temperature of the water coming from the solar panels, foreseeing the ignition of the burner only if the latter drops below the level necessary to guarantee optimal comfort for the user Comfort and Safety Functions Eco-Comfort function In COMFORT mode, thanks to the particular heat exchanger temperature maintenance system, the delivery of domestic hot water becomes even faster and more comfortable. In ECO mode, the production of domestic hot water takes place according to traditional standards. Antifreeze function Even in stand-by mode, i.e. in the absence of a heat request, if a water temperature of 5°C is detected, it activates the anti-freeze protection by igniting the burner at minimum power, in order to avoid damage due to freezing. Post-circulation device All models are equipped with this particular timed device which allows, after the burner has been switched off in heating mode, to recover all the heat accumulated due to thermal inertia from the exchanger, transferring it to the radiators and therefore to the rooms to be heated Circulation anti-blocking device After 24 hours of inactivity, the boiler circulator is automatically started for about 5 seconds to prevent it from blocking after a long period of inactivity. Strengths > Compact geometry primary heat exchanger entirely in copper > Instant production of domestic hot water with dedicated plate exchanger > Simple and complete control panel, LED user interface > High efficiency low consumption circulator (ErP - Class A) with anti-blocking system > Combustion chamber in anti-corrosion aluminized sheet, internally insulated with ecological fiber and burner in AISI 304 stainless steel > Can be combined with the modulating remote timer control > Casing painted white by anaphoresis with epoxy powders > Compact dimensions and low weight > Modulating heat input both in heating and in DHW production, managed by an electronic microprocessor board > Adjustable post-circulation after the heating phase > ECO/COMFORT system for rapid production of domestic hot water > Predisposition for solar systems : prearranged for the production of domestic hot water combined with solar panel systems > Standard by-pass Product Warranty : The warranty on this item is 24 months from the date of purchase.
€529,00
Ferroli Ferroli Condensing Boiler Bluehelix Tech Rrt 24 H Only Natural Gas Or LPG Heating Complete With Fume Exhaust Kit - New
Ferroli condensing boiler Bluehelix Tech RRT 24 H Heating only METHANE OR LPG Complete with Smoke Exhaust Kit - New Technical features: ERP Class (Class G - A++) A Heating max / min heat input (Hs) kW 24.5 / 5.0 Max / min heat output heating (80/60°C) kW 24 / 4.9 Max / min heat output heating (50/30°C) kW 26.0 / 5.4 Efficiency Pmax / Pmin (80-60°C) (Hi) % 98.1 / 98.0 Efficiency Pmax / Pmin (50-30°C) (Hi) % 106.1 / 107.5 Efficiency 30% 109/0.7 Max / min heating pressure bar 3 / 0.8 Empty weight kg 28 No. of pieces/pallet no. 12 CNG/LPG CODE 0T3D2BWA STRENGTHS: With attention to aesthetics and silence, it continues the tradition of appreciation of the previous "Bluehelix" series Boiler with thick stainless steel primary exchanger, with increased passages (at the top of the category) to guarantee durability and reduced maintenance, it maintains high efficiency even on old systems with oxidation and dirt. A+ System: in combination with the modulating remote control and the external probe (optional) it reaches the upper efficiency class A+ (scale from G to A+++) MC2: Multi Combustion Control, new combustion system with patented gas-adaptive technology of industrial origin for better adaptability of use to varying conditions of the gas network (e.g. fluctuations or reduced pressures) MGR: Natural gas, LPG, Propane air Ready through a simple configuration the boiler is able to operate on natural gas, LPG and propane air without the use of additional conversion kits MGR: Methane: LPG, Propane air Ready through a simple configuration the boiler is able to operate on methane, LPG and propane air without the use of additional conversion kits Exclusive exchanger-burner system with self-cooled door: simplifies maintenance and reduces its cost thanks to fewer parts to replace Sanitary production in combination with storage tank (optional), standard 3-way valve in the boiler Hydraulic connections covered by the boiler casing Large backlit multifunction graphic display for easy and correct parameter setting Standard by-pass BENEFITS OF BLUEHELIX TECH RRT H: Particularly suitable for operation in flues that require "heavy" ducting thanks to the approval for operation with 50mm diameter flue pipes FPS: Smoke Protection System. The flue clapet valve inserted as standard on the boiler allows easy connection to pressurized collective flue systems (e.g. in renovations), in accordance with the UNI 7129 standard Designed to simplify and facilitate normal maintenance and cleaning operations Minimum polluting emissions (class 6 according to EN 15502-1) Sliding temperature operation via optional external probe Low consumption modulating heating pump (ErP Ready - Class A) Digital flame control with three re-ignition attempts in the event of malfunction due to lack of flame detection (methane model) Place of installation: also for outdoors in a partially protected place up to -5°C as standard and up to -15°C with the help of the optional antifreeze heater kit Free methane/LPG/propaneted air transformation when checking the product and activating the warranty, to be requested from the Authorized Assistance Center The warranty on this item is 24 months from the date of purchase.
€759,00
Ferroli Ferroli Bluehelix Top Rrt 28c Methane Or LPG Condensing Boiler Complete With Fume Exhaust Kit Remote Control Dirt Remover And Standard Dosing Pump 0t3f2xwa - New
Ferroli Bluehelix TOP RRT 28C methane or LPG condensing boiler Complete with Fume Exhaust Kit Remote Control Dirt Separator and Doser STANDARD - NEW Energy label specifications according to the European ErP directive Class A heating energy efficiency Sanitary energy efficiency profile XL Class A Characteristics of heating/DHW operation: Thermal power 80°C-60°C Max Heating: kW 24 / 2,8 Heating max / min heat input (Hs) kW 27.2 / 3.2 Thermal power 50°C-30°C Max Sanitary: 26 / 3,1 kw Useful thermal efficiency 30%: 109.7 Max working pressure heating bar 3 NOx class 6 Sanitary flow rate ∆t 25°C 13.8 Supply voltage V/Hz 230V / 50Hz Dimensions HxWxD mm 700x420x250 Free methane/LPG/propaneted air transformation when checking the product and activating the warranty, to be requested from the Authorized Assistance Center - MGR: Natural gas, LPG, Propane air Ready through a simple configuration the boiler is able to operate on natural gas, LPG and propane air without the use of additional conversion kits BLUEHELIX TOP RRT STRENGTHS: - Boiler with thick stainless steel primary exchanger, with increased passages (at the top of the category) to guarantee durability and reduced maintenance, it maintains high efficiency even on old systems with oxidation and dirt - Boiler particularly robust and suitable for replacement even in particularly critical and resistant systems - Wide range of accessories supplied as standard with the product: CONNECT, latest generation wifi remote control with management via app / Magnetic dirt separator filter with corrosion inhibitor / Polyphosphate dosing filter for domestic hot water inlet - Boosted modulating heating circulator with high head on all models able to adapt even to particularly resistant systems (Erp Ready - Class A) - Enhanced domestic hot water exchanger with a high number of plates particularly immune to blockages and capable of maintaining the domestic hot water production capacity constant over time - A+ System : thanks to the combination with the CONNECT modulating remote control supplied as standard and reading the outside temperature directly from the internet, it reaches maximum energy efficiency A+ (scale from G to A+++) - Easily adapts to load conditions thanks to the wide modulation range which can reach up to 1:12 (mod. 34C, 1:10 mod. 28C) - MC2 : Multi Combustion Control, new combustion system with patented gas-adaptive technology of industrial origin for better adaptability of use to varying conditions of the gas network (e.g. fluctuations or reduced pressures) - MGR: Natural gas, LPG, Propane air Ready through a simple configuration the boiler is able to operate on natural gas, LPG and propane air without the use of additional conversion kits - Exclusive exchanger-burner system with self-cooled door: simplifies maintenance and reduces its cost thanks to fewer parts to replace - Hydraulic connections covered by the boiler shell, standard by-pass > BENEFITS OF BLUEHELIX TOP RRT C: - Particularly suitable for operation in flues that require "heavy" ducting thanks to the approval for operation with 50mm diameter flue pipes - FPS: Smoke Protection System. The flue clapet valve inserted as standard on the boiler allows easy connection to pressurized collective flue systems (e.g. in renovations), in accordance with the UNI 7129 standard - Designed to simplify and facilitate normal maintenance and cleaning operations - STOP AND GO: It is possible to delay the ignition of the burner by activating it only in the face of real withdrawals of domestic hot water - Minimum polluting emissions (class 6 according to EN 15502-1) - Digital flame control with three re-ignition attempts in the event of malfunction due to lack of flame detection (methane model) - Place of installation: also for outdoors in a partially protected place up to -5°C as standard and up to -15°C with the help of the optional antifreeze heater kit - Transformation of methane/LPG/Free propane air Product Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase
€1.173,00
IMMERGAS Immergas Boiler Open Chamber Nike Star 24 G20 LPG - New
Immergas Open Chamber boiler NIKE STAR 24 G20 LPG - NEW Nominal useful power kW 23.6 Dimensions (HxWxD) mm 781 x 440 x 240 Instant type Modulation range 40 - 100% Hot water production (∆t 30°C) l/min 11.1 NIKE STAR G20 New design. User interface with buttons and display. Internal installation. IPX4D degree of protection. Optional connection group (with positions and gas/water center distances on the wall unchanged compared to previous versions). Standard lower casing (to cover the connection pipes). Modulating circulator with low electricity consumption, with settings directly on the pump (no PWM). Conventional, instantaneous wall-mounted boiler. Extremely compact, it is ideal for replacing old boilers in the presence of branched collective flues. Low consumption Quick delivery of hot water Maximum compactness: only 24 cm deep. Ideal for replacement: in the presence of existing branched collective rods. IPX4D electrical protection. Standard antifreeze down to -5 °C. Product Warranty The warranty on this item is 24 months from the date of purchase.
€529,00
Unical Unical Kon E C24 Low Nox Condensing Boiler Complete With Smoke Kit - New Erp Kon E
Unical KONe C24 Low NOx condensing boiler complete with flue kit - NEW ErP Model: KONe 24C Energy efficiency: Seasonal efficiency class for heating A Declared load profile: XL Sanitary seasonal efficiency class: A Technical data: Nominal useful power: 23.6kW Seasonal heating energy efficiency ambient ηs 92% Useful thermal power in high temperature regime. (Tr 60 °C / tm 80 °C): 12.7kW Efficiency at nominal thermal power in high temperature regime (Tr 60 °C / Tm 80 °C) η4: 87% Useful power at 30% of nominal thermal power in low temperature regime (Tr 30 °C): 4.2 kW Efficiency at 30% of nominal thermal power in low temperature regime (Tr 30 °C) η1: 96.7% Annual electricity consumption QHE GJ: 40 Heating energy efficiency. of water ηWH: 86% Daily fuel consumption Qfuel : 22.07 kWh Sound power level indoors Lwa dB(A) 51 Annual electricity consumption AEC: 400 kWh Domestic hot water specific flow rate (Dt 30 °C): 11.2 l/min DHW production in cont. Dt 25 K (mixed): 13.3 l/min Expansion tank capacity: 8 lt Heating circuit pressure (min-max): 0.5-3.0 bar DHW circuit pressure (min-max): 0.5-6.0 bar IP X5D degree of protection NOx class: 6 Dimensions (HxWxD): 700x420x345mm; 34kg KONe KONe is a wall-hung condensing boiler with very low polluting emissions, thus falling within the new Class 6, the most restrictive currently in force. It is available in instant combined version. KONe has all the "Quality Stars" to satisfy every need: Exceptional modulation ratio up to 1:8 Efficiency >107% (ex dir. CE 92/42) ηs 93% (EU regulation 813/2013 - dir. ERP 2009/125/CE) Energy class A Primary exchanger in ultra-flat Al/Si/Mg Electronics with HWS “Hot Water Speed” function (vers. C) Low NOx class 6 (according to EN 15502-1) thanks to the fully electronic modulating premix burner with constant combustion ratio (both gas valve and fan) Production of hot water up to 13.3 l/min Dt 25 with special 12-plate (mod. 24 C) and 16-plate (mod. 28/35 C) exchanger in AISI 316L stainless steel "Pit stop" maintenance for technical assistance interventions "Soft touch" control panel with "Upgradable" protective closure via USB connection for diagnostics/programming with computer or dedicated handheld tool High efficiency modulating circulator HWS "Hot Water Speed" is the special KONe electronics that switches from heating to DHW function with burner and pump always active, improving user comfort who does not have to wait for hot water Management of 2 zones with 2 thermostats (modulating/on -off) thanks to the electronics that allow you to manage 2 heating zones at different temperatures (high for radiators and fan-coils, low for radiant panel systems) Sliding temperature programmed to operate with the lowest possible delivery temperature to help save energy Anti-overheating post-circulation automatically after the burner goes out, the boiler keeps the pump running for 5 minutes, preserving the components Chimney sweep function allows maintenance technicians to carry out the checks required by current standards in terms of efficiency and emissions Pump anti-blocking the blocking of the pump following long stops is avoided thanks to an automatic impulse of 5 sec. Everything like in a “Sim Card” All the operating characteristics of the boiler are memorized inside a SIM. The Unical Assistance Center is equipped with a handheld instrument with a 3" touchscreen that can be connected directly to KONe to develop the monitoring activity by speeding up the intervention times for solving any problems: data acquisition for a computer analysis monitoring in real-time operating parameters even remotely (from the office or PDA) management of "faults-history" “Pit stop” maintenance in less than 2 minutes KONe is the result of the experience of the Service and market suggestions, from which the Unical design staff has synthesized a technological complex that can be easily assembled and quickly disassembled. Product Guarantee All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.007,00
Ferroli Ferroli Condensing Boiler Bluehelix Prima 24 C Complete With Methane Or LPG Fume Exhaust Kit Including Boiler Save Kit - New
Ferroli condensing boiler Bluehelix Prima 24 C complete with methane fume exhaust kit - New Characteristics: Seasonal space heating energy efficiency class A Water heating energy efficiency class A Declared load profile XL Heating max / min heat input (Hs) kW 20.6 / 4.2 Max DHW heat input (Hi) kW 25 Efficiency 30% % 108.8 NOx emission class (EN 15502-1) - 6 Max working pressure heating bar 3 Min. heating operating pressure bar 0.8 Heating expansion vessel capacity 8 litres Max DHW working pressure bar 9 Sanitary flow rate ∆t 25°C l/min 14 Protection degree (IEC 60529) IP IPX4D Dimensions HxWxD 700x400x330 MGR: Natural gas, LPG, Propane air Ready through a simple configuration the boiler is able to operate on natural gas, LPG and propane air without the use of additional conversion kits Bluehelix Prima The range of generators is equipped with the tested heat exchanger in stainless steel. Designed and built according to the new ErP directives for eco-compatible design and labelling, BLUEHELIX PRIMA is at the top of its category. Top efficiency even on old systems (Replacements) The exchanger of the BLUEHELIX PRIMA thermal group compared to the more classic and widespread steel exchanger. The geometry of the exchanger to operate almost at maximum design efficiency even in conditions of partial blockage, while with the same amount of deposits and sediments (e.g. due to installation on old systems) the classic exchanger tends to block up much faster in the part in contact with the flame due to the reduced passage area of the fluid, in which a real barrier of deposits * is created which hinder the heat exchange and reduce the efficiency below the nominal values. Boiler with single circuit stainless steel primary exchanger without joints and/or welding, it maintains high efficiency even on old systems. MC2: Multi Combustion Control, new combustion system with patented gas-adaptive technology of industrial origin for better adaptability of use to varying conditions of the gas network (e.g. fluctuations or reduced pressures) MGR: Natural gas, LPG, Propane air Ready through a simple configuration the boiler is able to operate on natural gas, LPG and propane air without the use of additional conversion kits Instantaneous production of domestic hot water with dedicated plate domestic heat exchanger User interface with display and multifunction keys for adjusting and setting the parameters Standard by-pass Predisposition for solar systems: prepared for the production of domestic hot water combined with solar panel systems Minimum polluting emissions (class 6 according to EN 15502-1) Sliding temperature operation via optional external probe Low consumption modulating heating pump (ErP Ready - Class A) Digital flame control with three re-ignition attempts in the event of malfunction due to lack of flame detection (methane model) Place of installation: also for outdoors in a partially protected place up to -5°C as standard and up to -15°C with the help of the optional antifreeze heater kit The engine The pipe that makes up the BLUEHELIX PRIMA exchanger is made of AISI 304 stainless steel, a material that allows for the creation of an extremely smooth surface, therefore less susceptible to encrusting agents and deposits. Boiler control The control unit of BLUEHELIX PRIMA consists of an easy to use interface with backlit display. Using the buttons, it is possible to easily adjust the heating flow temperature, the domestic hot water setpoint, switch the generator on/off or activate the comfort function, monitoring the status of the boiler. The control panel is completed by a traditional pressure gauge which can check the system pressure at any time. MC2 (Multi Combustion Control) The electronics control the flame ionization current in order to ensure optimal combustion as the air density or gas quality varies. The relationship between the air/gas ratio (λ) and the flame ionization signal is used to control the air-gas ratio itself and therefore the combustion. MC2 : Multi Combustion Control, the new combustion system with patented Gas-adaptive technology improves the adaptability of use as the conditions of the gas network vary (e.g. fluctuations or reduced pressures). MGR Methane, LPG, Propane Ready Air Thanks to the new electronics supplied, the gas change operation is extremely simple. The MC2 combustion control performs constant monitoring of the quality of the combustion and by simply modifying a parameter on the electronic card (operation to be carried out only by qualified personnel) it is possible to operate the boiler on Natural Gas or LPG or Propane Air. It is therefore not necessary to purchase additional accessory kits. Easy Maintenance At the time of the first maintenance, the technician can appreciate the care with which every detail has been designed to facilitate his work. Thanks to the maximum accessibility of the main components, the BLUEHELIX PRIMA thermal unit allows maintenance to be carried out with maximum precision and speed. Some examples: The electrical box of the electronic card can be easily extracted from the chassis leaving free access to the internal parts. Easy access to the burner unit by removing 4 screws and the quick coupling (clip) of the fan. The exchanger with extra-large passages is designed to challenge the hardest waters and is easy to clean thanks to the non-collectorised single-pipe circuit. The domestic hot water inlet filter can be extracted very easily directly from the inside without having to remove the boiler hydraulic connections. Any disassembly and replacement of the plate heat exchanger takes place simply by removing the two Allen bolts accessible from the front Sun Easy function BLUEHELIX PRIMA has been designed to be easily inserted into systems made with the latest technologies. The SUN EASY system makes use of electronics that simplify the combination with solar panels with both natural and forced circulation. By means of a sensor located on the DHW circuit, it continuously controls the temperature of the water preheated by the solar panels, foreseeing the ignition of the burner only if the latter drops below the level necessary to guarantee optimal comfort for the user. Stop and Go function BLUEHELIX PRIMA has been designed to be easily inserted into systems made with the latest technologies. The SUN EASY system makes use of electronics that simplify the combination with solar panels with both natural and forced circulation. By means of a sensor located on the DHW circuit, it continuously controls the temperature of the water preheated by the solar panels, foreseeing the ignition of the burner only if the latter drops below the level necessary to guarantee optimal comfort for the user. External installation Antifreeze function To make the most of the available space, the new BLUEHELIX PRIMA 24C boiler can be installed recessed into the wall thanks to the special kit; for more critical installations, in completely uncovered places not protected from atmospheric agents, the "painted cabinet" kit is also available. In the event that the temperature in the boiler drops to 5°C, the burner automatically lights up and the circulator is activated in order to protect the appliance from damage caused by frost. This function is active with the boiler powered by the gas circuit and under electrical voltage. ECO-COMFORT Sanitary function In ECO operation, the production of domestic hot water takes place according to traditional standards, allowing for energy savings during periods of non-use. In COMFORT mode, thanks to the particular heat exchanger temperature maintenance system, the delivery of domestic hot water becomes even faster and more comfortable. The efficiency and the load profiles according to the ErP directive are at the top of the category: mod. 24 C / A - XL Product Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€636,00
IMMERGAS Offer - Immergas Open Chamber Gas Boiler Mini Nike 24 Kw LPG 3.025589
Technical features Model : Mini Nike 24 Product code : 3.025589 Maximum nominal heat input: 26.2 kW Minimum nominal heat input in DHW: 8.3 kW Minimum nominal heat input in heating mode: 10.9 kW Maximum useful thermal power: 23.8 kW Minimum useful thermal power in DHW: 8.1 kW Minimum useful thermal power in heating: 9.4 kW Useful thermal efficiency at 100% Pn (80/60 °C) : 91% Useful thermal efficiency at 30% of the nominal load. (80/60°C) : 88% Minimum gas flow rate to the burner: 0.88 m 3 /h Maximum gas flow rate to the burner: 2.77 m 3 /h Weighted CO : 27 mg/kWh Weighted NO X : 150 mg/kWh Specific flow rate in continuous domestic hot water service (∆t 30 °C): 11.4 l/min DHW circuit minimum dynamic pressure: 0.3 bar Nominal heating expansion vessel capacity: 6.0 litres Electrical protection degree : IPX4D Dimensions and weight Dimensions (HxWxD): 785x440x240 mm Empty weight: 26.1 kg Immergas Mini Nike Instant compact mural with natural draft Practicality and flexibility of installation A key feature of the range are the attachments which are unchanged from the previous MINI series. This peculiarity guarantees maximum ease of installation even during replacement. In addition, the compact size and low weight ensure convenience and ease of installation Solar function The boiler is designed to receive pre-heated water from a solar storage tank. By activating this function in the boiler parameters, the burner switches on only if it is necessary to integrate the heating of the water coming from the solar tank Ease of adjustment The newly designed dashboard, with backlit display, allows easy and intuitive use of the boiler. The self-diagnosis system displays the operating status of the boiler, further simplifying maintenance of the appliance by qualified technicians Ideal for connection to existing branched collective smoking pipes MINI NIKE 24 ErP complies with the thermal efficiency value (at 30% of the load) provided for by Article 4, paragraph 7 of Presidential Decree 59/09 for cases of mere replacement of the boiler, with connection to branched collective flues (ccr) Reduced electricity consumption In compliance with the new ErP directive, the boiler is equipped with a low energy consumption circulator Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€706,00
Savio Savio Aldens 24* Gas Condensing Boiler Complete With LPG Fume Kit
Overview SAVIO alDENS 24* CONDENSING BOILER COMPLETE WITH LPG FUME KIT LPG ideal for radiator systems - NEW ErP Technical specifications Model:ÿALDENS HE Product codeÿLPG: 103021021000 Product codeÿLPG: 103121029000 Technical data according to ErP directives Energy efficiency class in heating: A Sanitary energy efficiency class: A Load profiles: XLÿ Technical features: Minimum/Nominal useful power kW 2.9 ú 23.0 Minimum heat input with Methane/ Propan3.0 / 4.4 Efficiency class:ÿ Efficiency at nominal load in CONDENSATION % 100.9 Profitability at 30% of load% 98.6 NOx class 5 Operating temperature in heating min./maxøC 30 - 85 Adjustable temperature in sanitarywareøC 38 ú 60 DHW production mixed with t 25 l/min 13.2 Capacity of expansion vessel l 8 Supply voltageÿV-Hz 230/50 Degrees of protection IP X5D Dimensions HxWxD mm 700x420x345; 34 kgs Main features ALDENS ALDENS the new SAVIO range of condensing wall mounted boilers: excellent performance thanks to the aluminum heat exchanger and ease of use thanks to the control panel with knobs and display. Available in the combi version which combines the heating function and the production of domestic hot water. ALDENS presents a complete range of powers, 24 and 35 kW combi in the same extremely compact dimensions (700 x 420 x 345 mm). ALDENS has the strong point in the innovative primary heat exchanger in Al/Si/Mg with low water content designed to provide high yields that last over time. The digital display communicates the boiler operating parameters to the user in an easy and convenient way. Like the entire condensing range, SAVIO ALDENS allows you to make the most of savings from climatic thermoregulation, based on the system in which the boiler is installed. Main features: Outstanding fine 1:8 modulation ratio Efficiency>107% (ex dir. CE 92/42) Primary heat exchanger in ultra-flat Al/Si/Mg Electronics with HWS or Hot Water Speed function? Low NOx (class 5 according to EN 297 and EN 483) thanks to the modulating premix burner Production of fine hot water 13.3 l/min t 25 with special 12-plate (mod. 24 kW) and 16-plate (mod. 35 kW) exchanger in stainless steel Maintenance or Pit Stop? simple and intuitive control panel High efficiency modulating circulator (in line with ErP Dir. 2015) Sanitary exchanger Sanitary comfort ensured by the suitably sized plate exchanger to guarantee the best performance in terms of domestic hot water, reducing the waiting time and guaranteeing temperature stability. Modulating circulator with deaerator It represents the state of the art in the standard of high efficiency. In line with the ErP directive of 2015, with less than 1 W of consumption in stand-by and only 45 W in maximum operation, thanks to the wide modulation capacity, based on the request of the room thermostat and the temperatures detected by the sensors placed on the delivery/return automatically doses the boiler power to the needs of the system. Particularly silent and compact, it integrates with the safety valve, the by-pass and the drain cock. Exclusive Ai/Si/Mg heat exchanger It is made in a special Aluminum/Silicon/Magnesium alloy which ensures its efficiency and resistance over time. Thanks to the configuration of internal heat exchangers, efficiencies higher than 107% are achieved in the condensing regime, which means great economic savings and very low environmental impact for the user. The 35 kW version suitably increased. Plus Manage 2 zones with 2 thermostats:ÿALDENS versatile. Ideal for all systems, thanks to the electronics that allow you to manage 2 different temperature heating zones (high for radiators and fan-coils, low for radiant panel systems) by controlling them with dedicated modulating and on-off thermostats.ÿ Anti-overheating post-circulation:ÿFor 15 seconds, it maintains the thermal balance between delivery and return, even after intense DHW withdrawals, while in heating, with a duration of 5 minutes, it allows all residual thermal inertia to be disposed of.ÿ Sliding temperature operations:ÿFor maximum running economy.ÿ Antifreeze protection:ÿIt intervenes at 5°C and is activated in both domestic hot water and heating, bringing the temperature in the boiler to 15°C. The risk is avoided that ALDENS may freeze if low temperatures persist in the room where it is installed. If there is a lack of gas, the block signal will appear on the display.ÿ Pump anti-blocking: blocking of the pump following long stops is avoided thanks to an automatic 5-second pulse that the electronics sends to the motor every 24 hours of stop The multifunction LCD display, with timed backlighting, allows: Reading of the heating and sanitary temperatures Display of lockout due to lack of flame Error code display Malfunction signaling Operating/stand-by status Burner operating status Diagnostics with signaling of 11 anomalies Ecodesign directive: from 2015 on new condensing boilers In fact, after very long negotiations, the ÿEcodesign regulationÿ was approved, which introduces a new energy labeling on minimum efficiency standards for boilers.ÿIn particular, an energy classification from A+ to G is envisaged for space heating appliances and from A to G for appliances for the production of domestic hot water. ÿHence the obligation to installÿonly condensing boilers, heat generators capable of recovering a large part of the latent heat contained in the fumes which, otherwise, would be dispersed in the chimneyÿas occurs in traditional boilers. The recovered heat is transferred to the heating system, making it possible to achieve a yield of 106% with 92% of the traditional boiler and 84/85% of an oldÿÿtraditional generator.ÿThe installation obligation concerns manufacturers of boilers which will no longer be able to place on the market non-condensing starting from 26 September 2015. This means that starting from this date, anyone who wants to install a boiler in their own home will have to install only condensing models. Only one particular type of non-condensing boiler will continue to be produced which is technically called open room? to be installedÿ when it is not possible to replace an old boiler with a condensing boilerÿdue to problems related to the collective flueÿof some multi-family buildings. Products for heating water and the environment represent around 30% of the world's energy consumption in Europe.ÿ Designing eco-friendly products and promoting high performance technologies to end users in 2020 will lead to: An annual energy saving equivalent to 56 million tons of oil, quantifiable to the savings obtained if the water and environmental heating systems of two large nations like Italy were deactivated. As of 26 September 2015, the ErP regulation and ÿenergy labelingÿwill be applied in Europe to water and space heating products (boilers, heat pumps, micro-CHP devices, water heaters, and hot water storage tanks) u. How to read energy labels There are different labels, based on the type and function of the product (only room water heating of both, and in this case the label must bear both classifications). In addition to the energy class, the label provides other information that could be useful for understanding which product has the least environmental impact (for example power and consumption in different climatic zones, noise levels, etc.). It is possible to increase the energy efficiency of hot water production and space heating by connecting several products and accessories in one system. In this case it is necessary to prepare a system label in addition to that relating to the single product Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase. Shipping From the day payment is received, the product will be shipped within 3 working days. Free insured shipping for Italy. Shipping will take place via one of the national carriers
€1.074,00
Unical Unical Kon C24 Condensing Gas Boiler + Smoke Kit - Erp
Technical features Seasonal efficiency class for heating: Class A Sanitary seasonal efficiency class: Class A Declared load profile: M Nominal useful power: kW 22.6 Minimum useful power: 2.9 kW Combustion efficiency at nominal load 97.2% Combustion efficiency at reduced load 98.6% Minimum pressure of the heating circuit bar 0.5 Maximum pressure of the heating circuit bar 3 Minimum flow rate of the heating circuit. (∆t 20 °C) 1.2 l/min Specific sanitary water flow rate (∆t 30 °C) 11.2 l/min Total capacity of expansion tank 8 l IP X5D degree of protection Power supply: methane Characteristics Exchanger/Condenser in Aluminium/Silicon/Magnesium Ignition and electronic flame control with single electrode Modulation ratio 1:8 Fully electronic total premix burner with constant combustion ratio (both the gas valve and the fan) HWS “Hot Water Speed”: to eliminate the delay in DHW production Secondary exchanger in stainless steel with 12 "thermal length" plates, optimized for condensation, 14 plates (mod. 28-35) Operation down to -15° Modulating circulator according to the power request managed by the high-efficiency on-board electronics
€785,00 - €985,00
Ariston Ariston Condensing Boiler Genus One 24 Kw LPG Complete With Fume Exhaust Kit
Technical features Product code: 3301113 Energy label specifications according to the European ErP directive Class A heating energy efficiency Sanitary energy efficiency profile XL Class A Characteristics of heating/DHW operation: Nominal heat input max heating kW 22.0 Max DHW nominal heat input kW 26.0 Nominal thermal power kW 21.5 Efficiency at nominal heat input (60/80°C) 97.7% Efficiency at 30% (30°C) 109.8% DHW max/min temperature °C 60 / 36 DHW flow ∆T 25 °C (l/min) 15.4 Power supply voltage/frequency V/Hz 230/50 Total absorbed electric power W 80 Degree of protection of the electrical system IP X5D, Dimensions 24 kW mm (HxWxD) 745 x 400 x 315 Indoor installation and partially protected places Power supply: LPG Functionality: Room thermostat CUBE S NET 3319126 (optional) Operation CNG, LPG and propane air without the need for kits. The transformation takes place thanks to the combustion control by selecting the type of gas from the technical menu General characteristics ONE Series, the new generation of condensing boilers Serie ONE is the new generation of Ariston condensing boilers, studied down to the smallest detail to guarantee maximum performance for a long time. New XTRATECH™ exchanger: Maximum quality. XtraTech™ is the new exclusive* Ariston stainless steel heat exchanger , the heart of the ONE condensing boilers, developed to guarantee reliability and performance over time. Increased passage sections: +142% compared to the previous exchanger. Higher prevalence, lower risk of clogging, better performance. Every day, as if it were the first. Every single component has been designed to guarantee performance and durability over time: Ariston guarantee, shown in each component. Every single component has been rigorously tested and controlled on the production line. 100% of the boilers are tested again before being shipped to our customers. The best materials have been selected, to work for a long time even in the most critical situations. Excellent results, over time. Always connected with Ariston NET (optional) Wherever you are, always within reach of your Smartphone. Managing the comfort of your home has never been easier! Wherever you are, you can control the climate in your home using your smartphone. Use only the energy it needs. Easy to manage weekly time programming, directly from the app. Also, choose the savings "leaflet" for a real reduction in bill costs! Technical support always ON. Thanks to the innovative remote control system, the app warns your customer in case of malfunctions. By signing a maintenance contract, the Assistance Center will be able to intervene in the event of breakdowns, even remotely. Customer serenity is at the heart of Ariston NET. Total Comfort: Innovative functions to meet your needs ONE is equipped with an innovative set of smart functions to guarantee comfort every day with minimum waste of energy. Auto function: Patented function that allows you to automatically optimize the operation of the boiler, eliminating continuous switching on and off, reducing the stress on the components to a minimum. Comfort function: Hot water without any waiting! Lots of water with minimum energy consumption. Integrated Programming: Weekly hourly programming integrated into Alteas and Genus ONE products. Care function: Automatic reminder of routine maintenance. GEN ONE Characteristics: New XtraTech™ exchanger in exclusive* Ariston stainless steel, with high head Exchanger passage sections +142% compared to the previous version Large display, touch interface Ignition system, electronic combustion control Gas transformation from the technical menu Class A+ in heating reachable with thermoregulation Modulation ratio 1:10 Ariston NET connectivity in the boiler thanks to the Cube S NET thermostat (optional) BusBridgeNet® communication protocol AUTO function, Comfort New CARE function, automatic reminder of ordinary maintenance Internal sound absorbing panels Installation in partially protected places Fumes discharge 80, 60, 50 m Ecodesign directive: from 2015 only new condensing boilers After very long negotiations, the Ecodesign regulation was approved which introduces a new energy labeling on the minimum efficiency standards for boilers. In particular, an energy classification from A+ to G is envisaged for space heating appliances and from A to G for domestic hot water production appliances. Hence the obligation to install only condensing boilers, heat generators capable of recovering a large part of the latent heat contained in the fumes which, otherwise, would be dispersed in the chimney as occurs in traditional boilers. The recovered heat is transferred to the heating system, allowing to reach an efficiency of 106% against 92% of the traditional boiler and 84/85% of an old traditional generator. The installation obligation concerns boiler manufacturers who will no longer be able to place non-condensing boilers on the market starting from 26 September 2015. This means that starting from this date, anyone who wants to install a boiler in their own home will only have to install models condensing. Only a particular type of non-condensing boiler will continue to be produced which is technically called "open chamber" to be installed when it is not possible to replace an old boiler with a condensing boiler due to problems related to the collective flue of some multi-family buildings . What is Energy Labeling? Products for heating water and the environment represent around 30% of internal energy consumption in Europe. Designing eco-friendly products and promoting high performance technologies to end users in 2020 will lead to: An annual energy saving equivalent to 56 million tons of oil, quantifiable to the savings obtained if the water and environmental heating systems of two large nations such as Italy were deactivated. As of 26 September 2015, ErP regulation and energy labeling will be applied in Europe to water and space heating products (boilers, heat pumps, micro-CHP devices, water heaters, and water storage tanks hot)¹. How to read energy labels There are different labels, based on the type and functions of the product (water heating or space heating only or both, and in this case the label must show both classifications). In addition to the energy class, the label provides other information that could be useful for understanding which product has the least environmental impact (for example power and consumption in different climatic zones, noise, etc.). It is possible to increase the energy efficiency of hot water production and space heating by connecting several products and accessories in one system. In this case it is necessary to prepare a system label in addition to that relating to the single product Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.273,00