icon Wall mounted condensing boilers | CaldaieMurali

Wall mounted condensing boilers

Buy wall mounted condensing boilers for maximum energy savings. Reliable performance, optimum efficiency and compact design. Choose from our selection of condensing boilers to heat your home efficiently and sustainably. Find out more today!

1 product


  • Caldaia Argo A Condensazione Mod. Condensy Smart Plus 24 Kw Completa Di Kit Fumi - CaldaieMurali

    Argo Argo Condensing Boiler Mod. Condensy Smart Plus 24 Kw Complete With Smoke Kit

    ARGO condensing BOILER mod. CONDENSY SMART PLUS 24 kW complete with smoke kit Heating/DHW energy efficiency class: Class A Load profile: XL DHW/heating nominal heat input: 24./20.6 kW Sanitary nominal thermal power: 24 kW Expansion vessel water capacity: 8 litres Sanitary water production ΔT 25°C: 13.8 l/min Minimum water flow rate of the DHW circuit: 2.0 l/min Rated Electric Power: 85W Degree of protection: IPX5D Power supply: methane ARGON The new range of Condensy Plus 24-33 boilers consists of 2 models with instantaneous domestic hot water production. It was especially designed to be used when replacing with an older generation boiler. Everyone is aware of the advantages of condensing technology, i.e. high combustion efficiency and consequently energy savings and above all very low polluting emissions. 1:7 Very high modulation Greater efficiency given by a reduced number of switching on and off, the high modulation ratio in fact allows a significant reduction in consumption up to 10% and consequently an equal reduction in polluting emissions. The adjustment of the thermal power with respect to the dissipated power also prevents the generation of excessive overheating/cooling of the rooms. GAC system Condensy boilers are equipped with an innovative electronic management system which, thanks to the new electronics and the new electronic gas valve, guarantees automatic combustion control to maximize consumption reduction during all operating periods. The advantages are: • No manual intervention • Reduced measurement, calibration or nozzle changes • Self-adaptation to the gas quality and the length of the flue gas pipes to keep the efficiency constant • The boiler regulates itself to reduce gas consumption and pollution thanks to the constant control of emissions Digital control panel In the new Condensy Plus, there is a digital control panel with a backlit LCD display, very intuitive and simple to use thanks to the symbols silk-screened on the keys. The display shows all the information and settings of the operating parameters in a clear and direct way. 2-speed modulating pump with de-aeration The circulation pump of the Condensy Plus can operate at maximum or minimum speed or in "automatic": in the latter case, the speed (min./max) will be determined by the electronics which will have the task of maintaining a constant °C the delivery/return ΔT in heating, ensuring a significant reduction in pump consumption and also in maintenance costs, due to the lower mechanical stresses of a "normal pump" which always runs at maximum speed. When the boiler is switched on for the first time, it is possible to use the semi-automatic de-aeration function: by pressing the 2 keys for a few seconds, the function is activated which allows the elimination of the air present in the heating circuit. This avoids possible blockages of the boiler, overheating of the system and mechanical breakdowns. The electronic card will activate a 10 minute on/off cycle of the pump. The function will stop automatically at the end of the cycle. Condensy Smart Plus Wall-mounted condensing boiler with instant domestic hot water production Digital control panel with backlit LCD display Wide 1:7 modulation range; greater efficiency for fewer turns on and off Automatic combustion control for constant maintenance of maximum efficiency values ​​- GAC (Gas Adaptive Control) Complete soundproofing of the generator Standard climate control (with external probe available as an option) Arrangement for connection to a zone system Arrangement for integration with solar system Premix burner in AISI 316L stainless steel Water/fume exchanger in AISI 316L stainless steel, with integrated condensate collection tray Modulating fan with electronic speed variation Electric three-way diverter valve Increased DHW heat exchanger in stainless steel which facilitates condensation even in DHW operation Automatic by-pass Low consumption circulation pump and built-in deaerator Heating circuit safety valve at 3 bar Turbine flowmeter for greater comfort for the production of domestic hot water Safety thermostat against overheating of the water/fumes exchanger Safety thermostat against overheating of the water/fumes exchanger Water circulation safety hydraulic pressure switch NTC safety probe against fume overheating Temperature control with NTC probes Total antifreeze device Pump anti-blocking system and three-way valve which intervenes every 24 hours Pump post-circulation lasting 3 minutes which is activated in the heating function and after the main burner has switched off due to the intervention of the room thermostat. Heating circuit digital pressure gauge (system pressure indication on the display) Electronic thermometer

    €579,50

Recently viewed products

Login

Forgot your password?

Don't have an account yet?
Create account