Discover our exclusive selection of Baxi, perfect for enriching your home or workspace with style, comfort and functionality. Each piece is chosen to guarantee the best quality and satisfy your every need.
BAXI
BAXI Air-Water Heat Pump Monoblock Inverter Baxi Auriga 12t R-32 Three-Phase A7749310 With Remote Control Panel Included
ATTENTION ! OFFER VALID UNTIL STOCKS LAST FIRST START UP INCLUDED! Technical features Model : Auriga 12T Product code : A7749310 Remote Control Panel A7750381 Heating External air temperature 7°C - 87% RH Water temperature 30/35°C Nonimal Thermal Power: 12.30 kW Absorbed electrical power: 2.54 kW COP: 4.84 External air temperature 7°C - 87% RH Water temperature 45°C Nonimal Thermal Power: 12.10 kW Absorbed electrical power: 3.39 kW COP: 3.57 External air temperature 7°C - 87% RH Water temperature 47/55°C Nonimal thermal power: 11.90 kW Absorbed electrical power: 4.23 kW COP: 2.81 Cooling External air temperature 35°C - Water temperature 23/18°C Normal cooling capacity: 12.20 kW Absorbed electrical power: 2.60 kW EER: 4.78 External air temperature 35°C - Water temperature 12/7°C Normal cooling capacity: 10.90 kW Absorbed electrical power: 3.70 kW EER: 2.92 Energy efficiency Seasonal Energy Efficiency of low temperature space heating : 169% Seasonal Energy Efficiency of medium temperature space heating : 126% Seasonal Energy Efficiency Class at low temperature: A+++ Seasonal Energy Efficiency Class at medium temperature: A++ Performance Exchanger water flow rate: 2.13 m 3 /h Available pump head: 80 kPa Sound power level : 68 dB(A) Sound pressure level : 57.2 dB(A) Electrical data Power supply (V,Hz, Ø) : 380~415/50/3 Refrigerant gas : R32 Installation data Plumbing pipe diameter: 1" 1/4 Dimensions and weight Dimensions (HxWxD): 1414x1404x405 mm Empty weight: 172 Kg BAXI AURIGA Inverter Monobloc Air-Water Heat Pumps Baxi introduces Auriga , the range of inverter packaged air-to-water heat pumps with single-phase and three-phase power supply. The range is characterized by the ease and simplicity of installation . Furthermore, the increased head of the on-board circulator allows the unit to be installed in large-sized systems, to cover greater distances from the boiler room or to install the unit directly at the service of the fan coils. The range is wide and consists of 8 models from 4 to 16 kW, single-phase and three-phase versions Wide range of powers from 4 to 16 kW to satisfy all system requirements: heating, cooling and DHW production Easy to install in various living contexts, the increased head pump allows you to cope with greater pressure drops such as large systems or directly serving the fan coils STANDARD complete hydraulic equipment circulation pump, flow switch, expansion tank, safety valve, pressure gauge and “Y” filter Remote control panel control of system functions, programming and parameter verification. Furthermore, the connection via Modbus allows integration with BMS systems ErP Energy Labeling the labeling regulation (EU Regulation 2017/1369) requires the labeling of products according to a decreasing energy scale that goes from A+++ to D (in heating) and from A+ to F (in sanitary). The 5M/7M/9M models achieve an efficiency of A+++ in low temperature heating Components > Twin rotary DC inverter compressor : complete with internal thermal protection and crankcase heater, it is mounted on vibration dampers and wrapped around an insulating cap to reduce the transmission of noise and vibrations due to operation > Water-refrigerant exchanger : with brazed plates in AISI 316 steel with external anti-condensation insulation in expanded polypropylene and antifreeze resistance to prevent the formation of ice in the exchanger > Air-refrigerant exchanger : finned aluminum coil with hydrophilic treatment to facilitate the outflow of the condensate, mechanically expanded copper pipes with internal shaping to increase the heat exchange. Furthermore, the optimized circuitry allows to reduce the formation of ice in the coil during heat pump operation > Fan : axial fan directly coupled to the high efficiency brushless DC variable speed motor. The fan is installed on aerodynamic nozzles and safety grilles > Refrigerant circuit : made of pickled copper, it includes the electronic expansion valve, drier filters, high and low pressure switches, pressure transducer, cycle inversion valves, liquid receiver and separator, refrigerant injection valve on the suction side > Hydraulic circuit : in addition to the brazed plate heat exchanger, the unit includes the high head circulator, the expansion vessel, the safety valve, the flow switch, the pressure gauge and the air vent valve and the metal mesh Y-filter (assembly by the installer) > Electrical panel : includes fuse protection of the main internal components; the terminal block is divided into a power section for supplying the unit and a control terminal block for connecting auxiliary inputs and outputs and connection to the control panel Main Features BAXI AURIGA Maximum energy efficiency Monobloc system for the production of heating, cooling and DHW Wide operating range, with external air down to -25°C in heating, up to 46°C in cooling DHW system management: production up to 60°C, storage tank temperature management, DHW recirculation pump and solar thermal integration Suitable for integration with radiant terminals, fan coils and mixed systems Integrated management with various plant systems: boiler integration, solar integration, management of diverter valves and secondary circuit pump Single-phase and three-phase power supply Compressor with DC inverter technology with high modulation range Modbus network connection Low GWP R32 refrigerant Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€5.265,00