Technical features
Indoor units
1) Model
- Indoor Unit Catalog Code : 1x AS25TAEHRA(M)
- Commercial code: 2501321CN
- Power: 9000 Btu/h
- Integrated Wi-Fi
2) Model
- Indoor Unit Catalog Code : 1x AS35TAEHRA(M)
- Commercial code: 2501322CN
- Power: 12000 Btu/h
- Integrated Wi-Fi
Outdoor unit
Model
- Outdoor unit catalog code: 2U50MEFFRA
- Commercial code: 2502325BN
- Number of connectable indoor units: 2
Energy efficiency
- SEER: 6.5
- SCOP : 4.0
- Energy efficiency class in cooling: A++
- Energy efficiency class in heating: A+
- Annual energy consumption in cooling : 269 kWh/a
- Annual energy consumption in heating : 1645 kWh/a
Performance
- Cooling capacity : 5.0 kW
- Heating capacity: 5.2 kW
- Cooling absorption: 1.43 kW
- Heating absorption: 1.4 kW
- Sound power level : 63 dB(A)
- Sound pressure level : 53 dB(A)
Characteristics
- Power (V/Hz/Φ) : 220~240/50/1
- Refrigerant gas : R-32
- Guaranteed temperature range:
- - Cooling: -10° ~ 43°C
- - Heating: -15° ~ 24° C
Installation data
- Liquid pipe diameter : 6.35 mm (1/4") x2
- Gas pipe diameter : 9.52 mm (3/8") x2
- Maximum piping length: 30 m
- Maximum difference in height indoor unit / outdoor unit: 15 m
Dimensions
- External unit dimensions (LxPxH): 800x275x553 mm
- Outdoor unit weight: 36.0 Kg
R-32 Multisplit Haier
The earth, everyone's home. Let's protect it!
Compared to 100 years ago, the global temperature has increased by almost 0.5°C (from 1981 to 1990 +0.48°C). Global warming has attracted the attention of all countries, the main cause of the temperature increase is the release of greenhouse gases into the atmosphere. To remedy the situation, the Montreal Protocol was signed in 1987 and the Kyoto Protocol in 1997. In 2009, the European Union introduced the F-Gas regulation and it was approved in December 2013. The new rules came into force in May 2014 and January 2015. Without the rules indicated by the F-Gas regulation, we would produce 150,000 tons of CO2 per year.
Very low environmental impact refrigerant
Haier offers products that comply with the requirements of the European Union's environmental protection standards. To avoid dangerous damage to the environment, Europe is working to reduce greenhouse gas emissions and improve energy efficiency. Units with R32 refrigerant contain less gas and having a lower GWP than R410A units have a lower impact on global warming.
GWP = Global Warming Potential
The global warming potential (GWP, in Italian global warming potential) is the measure of how much a molecule of a certain greenhouse gas impacts on the greenhouse effect; the index is based on a relative scale which compares each gas with carbon dioxide, whose GWP has the value 1 by definition. Each GWP value is calculated for a specific time interval.
In terms of comparison, the GWP of the R32 refrigerant is equivalent to a value of 675, while the GWP of the R410A refrigerant corresponds to a value of 2088.
Haier Geos Plus built-in Wi-Fi
Self Clean
The Self-Clean technology freezes the humidity present in the air on the exchanger. The ice formed retains all the impurities, dust and bacteria that had settled on the surfaces. The subsequent defrosting phase causes the ice, as it melts, to drag the impurities with it towards the drain, leaving the exchanger clean and guaranteeing excellent quality of the outgoing air. If the evaporator is not cleaned regularly, the accumulated dirt reduces the heat exchange by 15/30% and also favors the proliferation of bacteria and mold
New WiFi
With the "hOn" application by Haier you can control all the Haier appliances in your Smart Home from your smartphone or tablet from a single app. Furthermore, through hOn, all the basic functions, purification functions and much more can be managed. The app allows the use of voice commands because it is compatible with Google Assistant and Alexa
Sleep function
Haier has designed a program for the night function of the air conditioner to ensure maximum comfort without wasting energy.
-
In heating mode, the temperature will be set 2°C lower during the first hour and another 2°C lower during the second hour than the set temperature. After 2 hours it will increase by 1°C and the temperature will remain constant for 6 hours before turning off the unit.
-
In cooling mode , the temperature will be set 1°C higher during the first hour and then again 1°C higher during the second hour than the set temperature. After that, the temperature will remain constant for 6 hours before the unit is turned off
intelligent air
This function automatically directs the deflectors in order to best distribute the flow according to the set mode.
-
In cooling mode, the deflectors direct the air flow upwards. Cold air tending downwards will decrease the room temperature evenly and rapidly.
-
In heating, the deflectors direct the air flow downwards. The hot air tending upwards will cause the room temperature to rise evenly and quickly.