ATTENTION THE BOILER IS SUPPLIED WITH METHANE. FOR CONVERTING TO LPG, CONTACT THE AUTHORIZED AREA SERVICE CENTER IN ADVANCE
Overview
BERETTA METEO GREEN HE 35ÿCSI AG LPG BOILER Cod. 20023984 - NEW ErP 2016 - COMPLETE WITH FUME EXHAUST KIT:ÿCondensing boilers designed to offer high energy efficiency.
Technical specifications
Code:ÿ20023984
Energy label specifications according to the European ErP directive
Class A heating energy efficiency
Sanitaryware energy efficiencyprofilXL Class A
Characteristics of heating/sanitary exercises:
Nominal heat input: 34.60 kW
Nominal thermal power: 33.74 kW
Classification European Directive EEC 92/42: ****
Efficiency at rated power: 97.3%
Reduced Load Return(30%): 108%
Total electric power: 116W
Quantity of hot water with t=25øC: 19.8 l/min
Dimensions (hxwxd) mm 890x553x275; 48kg
Standard antigelfin -15øC
StandardÿIncorporated antifreeze system (SAI)
LPG power supply
Legend:ÿ
HE (Hi Efficiency)
C (heating + sanitary water)
S (Sealed chamber)ÿ
I (electronic ignition, check ionization)
AG (antigel(-15øC).ÿ
Features list
MeteGreen HE (Hi Efficiency)
Beretta boilers offer reliability and excellent technology, such that they can be used in solar thermal systems in systems with the most recent and innovative technologies.
Beretta presents ÿMeteGreen he, the new range ofÿexternal to built-in condensing boilersdesignedÿto offer high energy efficiency.
In fact, the boiler is equipped with a wide modulation range (1:10),ÿwith range rated approval, with a low consumption circulator (class A)
with variable speed and all the advantages of the Meteo range.
Condensing exchanger:ÿ
Designed to provide high performance in compliance with the strictest European directives in terms of energy efficiency and low emissions.
The innovativeÿexchangerÿcondenser and the production processÿallowed Beretta toÿfiling a patentÿapplicationÿEurope(Patent Pending).ÿThe exchanger is made of seamlessÿaluminium tube without welding.ÿThe high thermal conductivityÿof aluminum allows
more uniform distribution of the temperature so as not to create overheating points benefit from a longer life over time
of the exchanger.ÿFurthermore, aluminumoffers highÿresistance to corrosion.ÿThe tubunic architecture (seriesÿcircuits) allows to obtain a largeÿsection for the passage of waterÿin the exchanger with the advantageÿof having low head losses ofÿpreventing both limescaleÿand impurity depositsÿ
The innovative aluminum condensing exchanger allows a good part of the heat from the fumes to be recovered, reducing losses to the chimney, and a good part of the latent heat from the condensation of the water vapor present in the fumes, reaching an energy yield value of four stars (according to the European Directive EEC 92/42). The exchanger is made of single aluminum tube without welding.
Modulation 1:10
The range offers a wide range of modulation to respond to real energy needs, while simultaneously offering a high reduction in consumption. Beretta implements this system using a totally pneumatic model, therefore safe and reliable. The electronics in fact act only on the
number of revolutions of the fan (incoming air flow rate) without intervening on the injection of the quantity of gas which is automatically sucked in. Beretta therefore introduces a new double distribution mixer: a mechanical damper with a catch that opens and closes a part of the venturi section in a way to divide the modulation range in two stages (smaller section with low airflows larger section with high airflows). Beretta has also developed a specific air intake silencer to reduce any resonances generated by the new mixer.
Low consumption modulating circulator (Class A)
It reduces electrical consumption by 60%, thanks also to self-adaptation in proportion to the power supplied in constant T operation.
Thanks to the new technology adopted, the electric motor of the circulator offers an Energy Efficiency Index EEI<0.23, which means
considerably reduced electricity consumption and already in line with the demands for energy savings. The new low-consumption modulating circulator (class A) offers a technologically advanced control that allows a high reduction in consumption thanks also to the modulation in a wide range of flow rates.
Comfort
Technological innovation combined with advanced electronicsÿmake it possible to obtain o Three starso in sanitary comfort:ÿthe unexpected standard from Pr EN 13203.
Smart management
The electronic panel is the boiler management brain. Simple and intuitive, it allows you to adjust the boiler parameters and activate the numerous functions. A large liquid crystal display shows all the important information. By turning the knobs, you can easily and intuitively set the temperature of the heating water and the domestic hot water. simply pressing a key allows you to choose the season. And when the boiler asks for it, pressing a key activates the Easy Filling function. The panel integrates the Climaÿ function
Easy: thermoregulation and external probe as standard.
Characteristics:
Modulation 1:10
Low consumption modulating circulator (Class A): self-adaptation in proportion to the power supplied constant DELTA T operation, (EEI<0.23)
RANGE RATED certification which allows you to adjust the thermal capacity of the boiler to the actual needs of the system
Performance 4 STARS according to European Directive EEC 92/42
Rendimental 100% Pn > 93+2 log Pn according to Legislative Decree 311/06
Low polluting emissions: class 5 according to UNI EN 483
Patented condensing exchanger (Patent Pending) in high flow rate aluminium
Sanitary comfort 3 STARS: the maximum unexpected by Pr EN 13203
Thermoregulation with standard external probe
Remote control panel REC 07 as standard
Standard gelfin protection -15øC (mod. AG)
IPX5D electrical protection degrees
For gas transformation, contact the Assistance Centres
Authorized Beretta technique
Beretta or ERP. The concrete commitment to a sustainable future
The acronym ÿErP, acronym of Energy related Products?ÿ (Products connected to the use of energy), identifies Directive 2009/125/EC aimed at reducing the energy consumption of products through eco-compatible design. Starting from 26 September 2015, the date of its effective entry into force in the European Union, it will mark an epochal turning point for heating products and the production of domestic hot water. On that date, other regulations simultaneously issued for the energy labeling of products will also become effective in addition to the corresponding Directive 2010/30/EU.
The regulation provides that all products intended for heating and the production of domestic hot water with a lower rated thermal power equal to 70 kW can be placed on the market with an ÿenergy labelÿthat highlights theÿefficiency class*. Different energy efficiency labels have been provided based on the different types of appliances/technologies, but all have the same graduated color scale that identifies the various levels of efficiency at a glance. The purpose of the labels is to give the consumer the possibility of identifying it facilitates the level of efficiency of a product by being able to carry out a homogeneous comparison between products that use different technologies. For products whose transformation efficiency is influenced by external conditions, such as heat pumps, the efficiency data reported for climatic bands.
In addition to the product labels, the European regulation has provided for the creation of a "system label" in the case of manufacturing plants with various appliances, components and related controls. This second type of labelling, thanks to the virtuous synergy between the various elements, will make it possible to create systems capable of achieving levels of efficiency even higher than those of the individual appliances. Also starting from the same date, new seasonal efficiency limits will be triggered for products intended for heating and combined. These for products with nominal thermal power equal to less than 400kW, will prevent inefficient products from being placed on the market. Also for DHW tanks there will be an obligation to comply with minimum heat loss limits. For primary water tanks, these will be subject to compliance with an energy classification based on heat loss. For sanitary accumulations, up to 500 liters there will be the obligation of labeling, from 500 to 2000 liters they will be bound to respect the energy classification. For heat pumps for heating and for mixed appliances, in addition to the seasonal efficiency limits, there will be specific noise emission limits for power sizes. In order to be placed on the market, gas-fired water heaters with solar heat pumps, in addition to energy labelling, will also have to comply with a series of requirements in terms of efficiency.
Warranty
All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.