Discover our exclusive selection of Sime, perfect for enriching your home or workspace with style, comfort and functionality. Each piece is chosen to guarantee the best quality and satisfy your every need.
Sime
Sime Sime Praktica 25 He Low Nox Condensing Boiler Kit Fumes Free Methane - New Erp
Sime Praktica 25 HE condensing boiler Low NOx flue gas kit methane - New ErP Nominal thermal power (80-60°C) kW 19.8 Nominal thermal power (50-30°C) kW 21.2 Reduced heat output G20 (80-60°C) kW 3.8 Reduced heat output G20 (50-30°C) kW 4.2 Reduced thermal power G31 (80-60°C) kW 4.3 Reduced thermal power G31 (50-30°C) kW 4.7 Nominal heat input in heating kW 20 DHW nominal heat input kW 24 Reduced heat input G20/G31 kW 4.0/4.5 Useful efficiency min/max (80-60°C) % 95.4/98.8 Useful efficiency min/max (50-30°C) % 105.0/106.1 Useful efficiency 30% of the load (40-30°C) % 108.4 Yield min. of combustion in situ (Presidential Decree 311) % 92.59 ELECTRICAL DATA Power supply voltage/frequency V/Hz 230/50 Electric absorbed power max W 67 Electric power absorbed min W 53 Electrical power absorbed by the system pump W 41 Shutdown losses at 50°C (EN 15502) W 120 Electrical protection degree IP X5D ENERGY PERFORMANCE Seasonal heating energy efficiency class. TO Seasonal heating energy efficiency % ninety two Heating sound power dB (A) 54 Sanitary energy efficiency class A Sanitary energy efficiency % 89 Declared load sanitary profile HEATING PERFORMANCE Heating adjustment range °C 20/80 Boiler water content 5.10 l Max working pressure bar 3 Max operating temperature °C 85 Expansion vessel capacity l 9 HEALTHCARE PERFORMANCE Nominal heat input kW 24 Reduced heat input G20/G31 kW 4/4.5 DHW adjustment range °C 10/60 Specific sanitary flow rate (EN 13203) l/min 11.5 Continuous DHW flow (∆t 25/35°C) l/min 13.8/9.8 DHW flow rate min l/min 2 Sanitary pressure min/max bar 0.5/7.0 Dimensions HxWxD mm 702x400x250 PRAKTICA Premixed condensing gas wall mounted boiler for heating only and instantaneous hot water production Installation type: B23P-B33P-B53P-C13-C33-C43-C53-C63-C83-C93 NOx emission class 6 (EN 15502-1:2015) Microprocessor electronic card with automatic adjustment of ignition power and maximum heating Automatic ignition with flame ionization control Degree of electrical protection to water IP X5D Primary water/fume coil exchanger in AISI 316L stainless steel Sanitary plate heat exchanger in stainless steel Heating system expansion tank Motorized diverter valve Retroactive combustion control with electronic gas valve Fume evacuation fan with electronic speed variation High efficiency system pump with low energy consumption (ErP) By-pass which ensures the circulation of water in the boiler when taps and thermostatic valves are used in the system Safety thermostat against overheating of the primary exchanger Smoke overheating probe 3 bar system safety valve Anti-blocking function of the pump and the diverter valve which activates automatically every 24 hours if there have been no requests for heat Antifreeze function which activates automatically if the water temperature in the boiler falls below the value set at parameter “tS 1.0” and, in the presence of an external probe, if the external temperature drops below the value set in parameter “tS 1.1” Chimney sweep function which lasts 15 minutes and facilitates the task of qualified personnel for measuring parameters and combustion efficiency Control panel equipped with display with numerical code self-diagnosis Knobs for adjusting the heating and domestic hot water temperatures Arrangement for SIME HOME remote control connection (optional) Protection of hydraulic fittings to be placed under the boiler cod. 8094530 (optional) Suitable for operation in a partially protected place according to EN 15502, with a maximum ambient temperature of 60°C and a minimum of -5°C Integrated climatic regulation Manual system loading device and water pressure control manometer Pressure transducer which blocks the boiler in case of water shortage Connections to the system in brass (DIN) Product Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€789,00
Sime Sime Vera 25 He LPG Low Nox Condensing Boiler Complete With Fume Exhaust Kit
Sime VERA 25 HE condensing boiler Low NOx flue gas kit for LPG - New ErP Vera 25 HE model Heating energy efficiency class A Sanitary energy efficiency class A XL load profile Performance Nominal / minimum heat output (80-60°C) kW 19.8 / 3.8 Nominal heat input in heating kW 20 DHW nominal heat input kW 24 Useful efficiency 30% of the load (40-30°C) % 108.4 Heating sound power dB (A) 54 Electrical protection degree IP X5D Heating expansion vessel capacity l 9 Dimensions HxWxD 700x400x250 VERA HE THE BOILER FOR EVERY TYPE OF SYSTEM Vera HE is the range of premixed wall-mounted condensing boilers that adapt to different system solutions. Thanks to the high head of the circulator, it is perfect for managing radiant floor systems without the use of booster pumps. The compact dimensions make it suitable for replacing existing fixtures and for outdoor or recessed installation using simple accessories. Vera HE features a new single-tube primary exchanger in stainless steel which boasts larger water passage sections compared to market standards, thus offering low pressure drops to the hydraulic system. The single-tube geometry guarantees higher water speeds, preventing deposits and encrustations and furthermore facilitating the cleaning of the exchanger. ACTIVE COMBUSTION CONTROL Vera HE is the range of premixed wall-mounted condensing boilers that adapt to different system solutions. Thanks to the high head of the circulator, it is perfect for managing radiant floor systems without the use of booster pumps. The compact dimensions make it suitable for replacing existing fixtures and for outdoor or recessed installation using simple accessories. Vera HE features a new single-tube primary exchanger in stainless steel which boasts larger water passage sections compared to market standards, thus offering low pressure drops to the hydraulic system. The single-tube geometry guarantees higher water speeds, preventing deposits and encrustations and furthermore facilitating the cleaning of the exchanger. The advanced control electronics check the combustion parameters at all times thanks to the flame sensor electrode and adjust the gas valve accordingly so as to always obtain the right air-gas ratio. The main advantages are: Simple commissioning, high reliability and low maintenance over time Compensation of combustion drifts caused by ageing, oxidation and insulation losses Ease of methane/LPG gas change using a simple parameter Guarantee of minimum polluting emissions guaranteed over time. Characteristics: Exchanger with oversized sections New heat exchanger with oversized water passage sections High head circulator Also suitable for radiant systems Active combustion control With electronic gas valve Three-piece shell For easier maintenance Can be installed externally or recessed Using special accessories or kits Product Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€960,00
Sime Boiler Sime Praktica 30 He Condensing Low Nox Smoke Kit Free Methane - New Erp
Sime Praktica 30 HE condensing boiler Low NOx flue gas kit methane - New ErP Nominal thermal power (80-60°C) kW 23.7 Nominal thermal power (50-30°C) kW 25.7 Reduced thermal power G20 (80-60°C) kW 4.5 Reduced thermal power G20 (50-30°C) kW 5.1 Reduced thermal power G31 (80-60°C) kW 4.5 Reduced thermal power G31 (50-30°C) kW 5.1 Nominal heat input in heating kW 24 DHW nominal heat input kW 30 Reduced heat input G20/G31 kW 4.8 Useful efficiency min/max (80-60°C) %94.3/98.7 Useful efficiency min/max (50-30°C) % 105.5/107.1 Useful efficiency 30% of the load (40-30°C) % 108.5 Yield min. of combustion in situ (Presidential Decree 311) % 92.74 ELECTRICAL DATA Power supply voltage/frequency V/Hz 230/50 Electric absorbed power max W 73 Electric power absorbed min W 54 Electrical power absorbed by the system pump W 41 Shutdown losses at 50°C (EN 15502) W 120 Electrical protection degree IP X5D ENERGY PERFORMANCE Seasonal heating energy efficiency class. TO Seasonal heating energy efficiency %93 Heating sound power dB (A) 58 Sanitary energy efficiency class A Sanitary energy efficiency % 84 Declared load health profile XL HEATING PERFORMANCE Heating adjustment range °C 20/80 Boiler water content 5.10 l Max working pressure bar 3 Max operating temperature °C 85 Expansion vessel capacity l 9 HEALTHCARE PERFORMANCE Nominal heat input kW 30 Reduced heat input G20/G31 kW 4.8 DHW adjustment range °C 10/60 Specific sanitary flow rate (EN 13203) l/min 13.5 Continuous DHW flow (∆t 25/35°C) l/min 16.7/11.9 DHW flow rate min l/min 2 Sanitary pressure min/max bar 0.5/7.0 Dimensions HxWxD mm 702x400x250 PRAKTICA Premixed condensing gas wall mounted boiler for heating only and instantaneous hot water production Installation type: B23P-B33P-B53P-C13-C33-C43-C53-C63-C83-C93 NOx emission class 6 (EN 15502-1:2015) Microprocessor electronic card with automatic adjustment of ignition power and maximum heating Automatic ignition with flame ionization control Degree of electrical protection to water IP X5D Primary water/fume coil exchanger in AISI 316L stainless steel Sanitary plate heat exchanger in stainless steel Heating system expansion tank Motorized diverter valve Retroactive combustion control with electronic gas valve Fume evacuation fan with electronic speed variation High efficiency system pump with low energy consumption (ErP) By-pass which ensures the circulation of water in the boiler when taps and thermostatic valves are used in the system Safety thermostat against overheating of the primary exchanger Smoke overheating probe 3 bar system safety valve Anti-blocking function of the pump and the diverter valve which activates automatically every 24 hours if there have been no requests for heat Antifreeze function which activates automatically if the water temperature in the boiler falls below the value set at parameter “tS 1.0” and, in the presence of an external probe, if the external temperature drops below the value set in parameter “tS 1.1” Chimney sweep function which lasts 15 minutes and facilitates the task of qualified personnel for measuring parameters and combustion efficiency Control panel equipped with display with numerical code self-diagnosis Knobs for adjusting the heating and domestic hot water temperatures Arrangement for SIME HOME remote control connection (optional) Protection of hydraulic fittings to be placed under the boiler cod. 8094530 (optional) Suitable for operation in a partially protected place according to EN 15502, with a maximum ambient temperature of 60°C and a minimum of -5°C Integrated climatic regulation Manual system loading device and water pressure control manometer Pressure transducer which blocks the boiler in case of water shortage Connections to the system in brass (DIN) Product Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€915,00
Sime Sime Vera 25 He Methane Low Nox Condensing Boiler Complete With Fume Exhaust Kit
Sime VERA 25 HE condensing boiler Low NOx flue gas kit Methane - New ErP Vera 25 HE model Heating energy efficiency class A Sanitary energy efficiency class A XL load profile Performance Nominal / minimum heat output (80-60°C) kW 19.8 / 3.8 Nominal heat input in heating kW 20 DHW nominal heat input kW 24 Useful efficiency 30% of the load (40-30°C) % 108.4 Heating sound power dB (A) 54 Electrical protection degree IP X5D Heating expansion vessel capacity l 9 Dimensions HxWxD 700x400x250 VERA HE THE BOILER FOR EVERY TYPE OF SYSTEM Vera HE is the range of premixed wall-mounted condensing boilers that adapt to different system solutions. Thanks to the high head of the circulator, it is perfect for managing radiant floor systems without the use of booster pumps. The compact dimensions make it suitable for replacing existing fixtures and for outdoor or recessed installation using simple accessories. Vera HE features a new single-tube primary exchanger in stainless steel which boasts larger water passage sections compared to market standards, thus offering low pressure drops to the hydraulic system. The single-tube geometry guarantees higher water speeds, preventing deposits and encrustations and furthermore facilitating the cleaning of the exchanger. ACTIVE COMBUSTION CONTROL Vera HE is the range of premixed wall-mounted condensing boilers that adapt to different system solutions. Thanks to the high head of the circulator, it is perfect for managing radiant floor systems without the use of booster pumps. The compact dimensions make it suitable for replacing existing fixtures and for outdoor or recessed installation using simple accessories. Vera HE features a new single-tube primary exchanger in stainless steel which boasts larger water passage sections compared to market standards, thus offering low pressure drops to the hydraulic system. The single-tube geometry guarantees higher water speeds, preventing deposits and encrustations and furthermore facilitating the cleaning of the exchanger. The advanced control electronics check the combustion parameters at all times thanks to the flame sensor electrode and adjust the gas valve accordingly so as to always obtain the right air-gas ratio. The main advantages are: Simple commissioning, high reliability and low maintenance over time Compensation of combustion drifts caused by ageing, oxidation and insulation losses Ease of methane/LPG gas change using a simple parameter Guarantee of minimum polluting emissions guaranteed over time. Characteristics: Exchanger with oversized sections New heat exchanger with oversized water passage sections High head circulator Also suitable for radiant systems Active combustion control With electronic gas valve Three-piece shell For easier maintenance Can be installed externally or recessed Using special accessories or kits Product Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€960,00
Sime Sime Open Chamber Boiler Vera 25 Of Methane Low Nox - Erp
ATTENTION THE BOILER WILL BE SUPPLIED WITH METHANE. FOR LPG OPERATION, CONTACT THE AUTHORIZED AREA SERVICE CENTER IN ADVANCE SIME open chamber boiler VERA 25 OF Methane Low NOx - ErP Technical features. ENERGY PERFORMANCE Seasonal heating energy efficiency class C Seasonal heating energy efficiency % 78.4 Heating sound power dB (A) 59 Sanitary energy efficiency class A Sanitary energy efficiency % 80.3 Declared load health profile XL HEATING PERFORMANCE Heating adjustment range °C 20/80 Water content in the boiler l 3.15 Max working pressure bar 3 Max operating temperature °C 85 Expansion vessel capacity l 8 HEALTHCARE PERFORMANCE Nominal heat input kW 23.0 Reduced heat input kW 10.0 DHW adjustment range °C 10/60 Specific sanitary flow rate (EN 13203) l/min 10.0 Continuous DHW flow (∆t 25/35°C) l/min 12.3/8.8 DHW flow rate min l/min 2.2 Sanitary pressure min/max bar 0.4/7.0 DIMENSIONS Dimensions HxWxD mm 700x400x250 VERA OF Latest generation low NOx boiler for open chamber heating and domestic hot water production. The retroactive combustion control with electronic gas valve guarantees higher overall efficiency and lower running costs. Low NOx wall mounted boiler for heating and instantaneous hot water production Installation type: B11BS NOx emission class 6 Natural draft smoke outlet Microprocessor electronic card with automatic adjustment of ignition power and maximum heating Automatic ignition with flame ionization control Degree of electrical protection to water IP X4D Low NOx atmospheric burner Sanitary plate heat exchanger in stainless steel Heating system expansion tank Motorized diverter valve Retroactive combustion control with electronic gas valve High efficiency system pump with low energy consumption (ErP) Double element heating probe with safety thermostat functions Fume safety device which interrupts the gas flow to the burner in the event of an obstructed flue and/or lack of draught 3 bar system safety valve Anti-blocking function of the pump and the diverter valve which activates automatically every 24 hours if there have been no requests for heat Antifreeze function which activates automatically if the water temperature in the boiler drops below the value set for the parameter "tS 1.0" and, in the presence of an external probe, if the outside temperature drops below the value set for the parameter "tS 1.1” Chimney sweep function which lasts 15 minutes and facilitates the task of qualified personnel for measuring the parameters and combustion efficiency and for checking the gas pressures at the nozzles Control panel equipped with display with numerical code self-diagnosis Knobs for adjusting the heating and domestic hot water temperatures Arrangement for SIME HOME remote control connection (optional) Protection of hydraulic fittings to be placed under the boiler cod. 8094531(optional) Integrated climatic regulation Hydraulic pressure switch which blocks the boiler in the event of a water shortage Manual device for filling the system Water pressure control hydrometer Suitable for operation in a partially protected place according to EN 15502, with a maximum ambient temperature of 60 °C and a minimum of - 5°C Connections to the system in brass (DIN) Product Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€564,00
Sime Sime Brava One 25 He Methane Condensing Boiler Complete With Fume Exhaust Kit
SIME BRAVA ONE 25 HE METHANE condensing BOILER COMPLETE WITH FUME EXHAUST KIT For heating and domestic hot water production DHW thermal power kW 4.0÷24.0 Heating thermal power (50-30°C) kW 4.3÷21.4 Efficiency class (EEC 92/42): **** Continuous DHW flow rate Δt 30°c: 11.2 l/min Heating energy efficiency class: A Dimensions (h x w x d): 700 x 400 x 250 mm; 28.3kg METHANE version GOOD ONE Premixed condensing boiler Wide modulation range Stainless steel coil exchanger Extremely compact dimensions Three-piece cloak DHW management with dedicated probe Retroactive combustion control with electronic gas valve Can be installed outdoors and recessed using accessories (see page 78) 2 versions with 24.0 and 28.0 kW domestic hot water production Integrated climatic regulation Incredible dimensions for its potential The particularly compact dimensions are the most evident feature of the new Brava Slim and Brava One: 70 cm x 40 cm x 25 cm for almost all models, up to 35 kW of power. A unique result on the market! For example, comparing the condensing versions with previous models, there is an average decrease in volume of over 30% You will sleep soundly With Brava Slim and Brava One, Sime adopts the brass hydraulic group on all the boilers in the range. Brass, synonymous with quality, reliability and long life, guarantees peaceful sleep. The new hydraulic group also introduces the order of connections according to the DIN standard, adopted by the majority of European manufacturers, a further guarantee of maximum installation flexibility of Brava Slim and Brava one. For every action the perfect reaction Boiler manufacturers have always been concerned with developing the most efficient and ecological combustion. The passage of time often nullifies these efforts, lowering the quality of the combustion due to uncontrollable physical drifts. An active control of the combustion allows maintain the system within predefined efficiency, safety and emissions limits. The system is based on two fundamental components: the ignition electrode and the control electronics. The electrode, immersed in the flame, acts as a combustion control sensor providing feedback to the electronics that regulates combustion continuously. Advantages: Simple commissioning, high reliability and low maintenance over time Maximum safety in the event of poor exhaust gas evacuation or recirculation of unburnt gases (not detectable by traditional systems) Better control of combustion drifts caused by machining tolerances, oxidation and insulation losses No mechanical settings: electronic calibration of the gas valve Increased reliability by eliminating the air pressure switch in traditional combustion boilers Easier natural gas/LPG changeover via a simple parameter in condensing boilers and safe operation in the event of using the wrong gas Versatile and adaptable to any environment The extremely compact dimensions of Brava Slim and Brava One offer maximum assembly flexibility: all condensing and sealed chamber models from 25 to 35 kW are suitable for outdoor or recessed installation using simple accessories. Product Guarantee All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€731,00