Open flue wall mounted boilers offer a practical and reliable option for heating your home. Easy to install, efficient performance and versatile. Choose from our selection of open flue wall mounted boilers to ensure constant comfort in every room!
Open chamber wall-mounted boilers
Savio Open Chamber Gas Boiler Savio Acta Nox 28a Nox 6 Methane Or LPG - New Methane
Technical features Model: ACTA NOX 28A Heating energy efficiency Class: C Sanitary Energy Efficiency Class: B Withdrawal profile: XL Heating/DHW nominal heat input: 30.7 kW Heating/DHW maximum useful power: 27.6 kW Yield name 60°/80°C: 90% Yield at 30% load: 89.3% Energy efficiency stars: (dir 92/42/EEC) ** NOx class: 6 Weighted NOx: 28 mg/kWh Minimum/maximum heating temperature: 38/85 °C Minimum/maximum heating pressure: 0.3/3.0 bar Capacity of the expansion tank (total): 8lt DHW minimum/maximum temperature: 35/60°C Maximum flow rate (ΔT=25 K) / (ΔT=35 K): 15.8/ 11.3 l/min Specific sanitary flow rate (ΔT=30 K): 12.5 l/min Voltage / Power at nominal heat input V~/ W: 230~/56 Degree of protection: IPX4D Minimum/maximum flue gas temperature: 83 / 130°C Extremely compact dimensions hxwxd: mm 703x400x325 CNG or LPG power supply ACTA NOX ACTA NOX is the range of Savio boilers designed to meet modern housing needs that require reliable, compact and high performance products. The ACTA NOX range includes open chamber boilers with power ratings of 24 kW and 28 kW . The ACTA NOX series is suitable for heating and domestic hot water production. ACTA NOX has very compact dimensions which make it easy to place in any environment. Characteristics: High yields Primary heat exchanger in copper, high circulation lamellar Sanitary plate heat exchanger in stainless steel Water cooled low NOx burner High efficiency pump with low energy consumption Integration with SAVIO solar systems using a solar kit Digital control panel with display. The electronic card allows you to: Adjust the ignition pressure Adjust the restart frequency Manage the post-circulation of the high efficiency pump View fault diagnostics and lockout status. Also available : Boiler antifreeze safety Primary circuit thermal inertia disposal. Primary exchanger ACTA NOX features a water-cooled burner which allows to achieve high efficiency combustion and to limit the emissions of polluting substances. The burner is therefore characterized by a flame at a lower temperature than traditional boilers, which reduces the production of nitrogen oxides. Even the shape of the flame is specific to the water-cooled burner, in fact, it presents the flame in a uniform manner and with a reduced height. This makes ACTA NOx the SAVIO product that satisfies the needs of maximum domestic comfort and respect for polluting emissions. Secondary exchanger ACTA NOX is available in a mixed version for heating, domestic hot water production: the hot water is supplied at an adjustable and constant temperature thanks to the electronic modulation of the boiler. The DHW exchanger is made of stainless steel and has a low inertia which guarantees excellent performance. Control panel Summer/winter/off selector Heating temperature regulator DHW temperature regulator Digital and analog pressure reading DHW and heating temperature visualization from the display Display of fault diagnostics, block status and fault history Recommended fill display Display annual periodic maintenance expiry Thermo-hydrometer for reading the water pressure on the primary side. Integration with solar ACTA NOX can be easily combined with a solar system using the Biasi solar kit. Simple and immediate to install, it does not require electrical parts and allows optimizing the integration of the solar system with the boiler which intervenes only when necessary to guarantee the required comfort temperature. Thermoregulation Hydraulic groups of innovative conception: Motorized 3-way valve Integrated automatic by-pass: allows the boiler to adapt to the needs of modern heating systems Absolute heating pressure switch: guarantees protection of the boiler in the event of a lack of water or circulation Sanitary flowmeter Easily accessible filling tap Drain tap Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.024,00
Savio Open Chamber Gas Boiler Savio Acta Nox 24a Nox 6 Methane Or LPG - New Methane
Technical features Model: ACTA NOX 24A Heating energy efficiency Class: C Sanitary Energy Efficiency Class: B Withdrawal profile: XL Heating/DHW nominal heat input: 26.0 kW Heating/DHW maximum useful power: 23.7 kW Yield name 60°/80°C: 91.3% Yield at 30% load: 92.6% Energy efficiency stars: (dir 92/42/EEC) ** NOx class: 6 Weighted NOx: 39 mg/kWh Minimum/maximum heating temperature: 38/85 °C Minimum/maximum heating pressure: 0.3/3.0 bar Capacity of the expansion tank (total): 8lt DHW minimum/maximum temperature: 35/60°C Maximum flow rate (ΔT=25 K) / (ΔT=35 K): 13.6 / 9.7 l/min Specific sanitary flow rate (ΔT=30 K): 11.2 l/min Voltage / Power at nominal heat input V~/ W: 230~/56 Degree of protection: IPX4D Minimum/maximum smoke temperature: 71 / 106°C Extremely compact dimensions hxwxd: mm 703x400x325 CNG or LPG power supply ACTA NOX ACTA NOX is the range of Savio boilers designed to meet modern housing needs that require reliable, compact and high performance products. The ACTA NOX range includes open chamber boilers with power ratings of 24 kW and 28 kW . The ACTA NOX series is suitable for heating and domestic hot water production. ACTA NOX has very compact dimensions which make it easy to place in any environment. Characteristics: High yields Primary heat exchanger in copper, high circulation lamellar Sanitary plate heat exchanger in stainless steel Water cooled low NOx burner High efficiency pump with low energy consumption Integration with SAVIO solar systems using a solar kit Digital control panel with display. The electronic card allows you to: Adjust the ignition pressure Adjust the restart frequency Manage the post-circulation of the high efficiency pump View fault diagnostics and lockout status. Also available : Boiler antifreeze safety Primary circuit thermal inertia disposal. Primary exchanger ACTA NOX features a water-cooled burner which allows to achieve high efficiency combustion and to limit the emissions of polluting substances. The burner is therefore characterized by a flame at a lower temperature than traditional boilers, which reduces the production of nitrogen oxides. Even the shape of the flame is specific to the water-cooled burner, in fact, it presents the flame in a uniform manner and with a reduced height. This makes ACTA NOx the SAVIO product that satisfies the needs of maximum domestic comfort and respect for polluting emissions. Secondary exchanger ACTA NOX is available in a mixed version for heating, domestic hot water production: the hot water is supplied at an adjustable and constant temperature thanks to the electronic modulation of the boiler. The DHW exchanger is made of stainless steel and has a low inertia which guarantees excellent performance. Control panel Summer/winter/off selector Heating temperature regulator DHW temperature regulator Digital and analog pressure reading DHW and heating temperature visualization from the display Display of fault diagnostics, block status and fault history Recommended fill display Display annual periodic maintenance expiry Thermo-hydrometer for reading the water pressure on the primary side. Integration with solar ACTA NOX can be easily combined with a solar system using the Biasi solar kit. Simple and immediate to install, it does not require electrical parts and allows optimizing the integration of the solar system with the boiler which intervenes only when necessary to guarantee the required comfort temperature. Thermoregulation Hydraulic groups of innovative conception: Motorized 3-way valve Integrated automatic by-pass: allows the boiler to adapt to the needs of modern heating systems Absolute heating pressure switch: guarantees protection of the boiler in the event of a lack of water or circulation Sanitary flowmeter Easily accessible filling tap Drain tap Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€826,00
Savio Gas Boiler Savio Acta E 24 A * LPG Open Chamber
SAVIO ACTA GAS BOILER AND 24 A* METHANE OPEN CHAMBER Model: ACTA 24A Energy label specifications according to the European ErP directive Class C heating energy efficiency Sanitary Energy Efficiency Class B Withdrawal profile: XL Characteristics of heating/DHW operation: Heating/DHW nominal heat input: 26.6 kW Heating/DHW maximum useful power: 24.1 kW Yield name 60°/80°C: 90.6% Yield at 30% load: 89.6% Energy efficiency stars: (dir 92/42/EEC) ** NOx class n° 3 Weighted NOx: 135 mg/kWh Minimum/maximum heating temperature: 38/85 °C Minimum/maximum heating pressure: 0.3/3.0 bar Capacity of the expansion tank (total): 8lt DHW minimum/maximum temperature: 35/60°C Maximum flow rate (ΔT=25K) / (ΔT=35K): 13.8/9.9 l/min Specific sanitary flow rate (ΔT=30 K): 11.5 l/min Voltage / Power at nominal heat input V~/ W 230~/56 Degree of protection n° IPX4D Minimum/maximum smoke temperature: 83/108°C Extremely compact dimensions hxwxd: mm 703x400x325 ; 28.7kg CNG or LPG power supply ACTA ACTA is the range of Savio boilers designed to meet modern housing needs that require reliable, compact and high performance products. The ACTA NEW range includes open chamber boilers with powers of 24 kW and 28 kW. The ACTA series is suitable for heating and domestic hot water production. ACTA has very compact dimensions which make it easy to place in any environment. Characteristics: High yields Primary heat exchanger in copper, high circulation lamellar Sanitary plate heat exchanger in stainless steel High efficiency pump with low energy consumption Integration with SAVIO solar systems using a solar kit Digital control panel with display. The electronic card allows you to: - Adjust the ignition pressure - Adjust the restart frequency - Manage the post-circulation of the high efficiency pump - View fault diagnostics and lockout status. Also available: - Boiler antifreeze safety - Disposal of primary circuit thermal inertia. Primary exchanger ACTA is a high efficiency boiler: the most compact exchanger, with reduced fin pitch to increase their number and ensure maximum efficiency. The large heat exchange surface is guaranteed by the helical section of the passage pipes and by the lamellar structure. The high exchange efficiency is guaranteed by the double circulation in counter flow. The exchanger is made of copper with a protective coating resistant to high temperatures. Secondary exchanger ACTA is available in a mixed version for heating and domestic hot water production: the hot water is supplied at an adjustable and constant temperature thanks to the electronic modulation of the boiler. The DHW exchanger is made of stainless steel and has a low inertia which guarantees excellent performance. Control panel Summer/winter/off selector Heating temperature regulator DHW temperature regulator Digital and analog pressure reading DHW and heating temperature visualization from the display Display of fault diagnostics, block status and fault history Recommended fill display Display annual periodic maintenance expiry Thermo-hydrometer for reading the water pressure on the primary side. Integration with solar ACTA can be easily combined with a solar system using the Biasi solar kit. Simple and immediate to install, it does not require electrical parts and allows optimizing the integration of the solar system with the boiler which intervenes only when necessary to guarantee the required comfort temperature. Reliability and security Hydraulic groups of innovative conception: Motorized 3-way valve Integrated automatic by-pass: allows the boiler to adapt to the needs of modern heating systems Absolute heating pressure switch: guarantees protection of the boiler in the event of a lack of water or circulation Sanitary flowmeter Easily accessible filling tap Drain tap Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€659,00
Savio Gas Boiler Savio Acta E 28 A* Methane Open Chamber
SAVIO ACTA GAS BOILER AND 28 A* METHANE OPEN CHAMBER Model: ACTA 28A Energy label specifications according to the European ErP directive Class C heating energy efficiency Sanitary Energy Efficiency Class B Withdrawal profile: XL Characteristics of heating/DHW operation: Heating/DHW nominal heat input: 30.6 kW Heating/DHW maximum useful power: 27.6 kW Yield name 60°/80°C: 90% Yield at 30% load: 89.3% Energy efficiency stars: (dir 92/42/EEC) ** NOx class n° 3 Weighted NOx: 148 mg/kWh Minimum/maximum heating temperature: 38/85 °C Minimum/maximum heating pressure: 0.3/3.0 bar Capacity of the expansion tank (total): 8lt DHW minimum/maximum temperature: 35/60°C Maximum flow rate (ΔT=25K) / (ΔT=35K): 15.8/11.3 l/min Specific sanitary flow rate (ΔT=30 K): 12.5 l/min Voltage / Power at nominal heat input V~/ W 230~/56 Degree of protection n° IPX4D Minimum/maximum smoke temperature: 83/108°C Extremely compact dimensions hxwxd: mm 703x400x325 ; 29.4kg CNG or LPG power supply ACTA ACTA is the range of Savio boilers designed to meet modern housing needs that require reliable, compact and high performance products. The ACTA range includes open chamber boilers with powers of 24 kW and 28 kW. The ACTA series is suitable for heating and domestic hot water production. ACTA NEW has very compact dimensions which make it easy to place in any environment. Characteristics: High yields Primary heat exchanger in copper, high circulation lamellar Sanitary plate heat exchanger in stainless steel High efficiency pump with low energy consumption Integration with SAVIO solar systems using a solar kit Digital control panel with display. The electronic card allows you to: Adjust the ignition pressure Adjust the restart frequency Manage the post-circulation of the high efficiency pump View fault diagnostics and lockout status. Also available: Boiler antifreeze safety Primary circuit thermal inertia disposal. Primary exchanger ACTA is a high efficiency boiler: the most compact exchanger, with reduced fin pitch to increase their number and ensure maximum efficiency. The large heat exchange surface is guaranteed by the helical section of the passage pipes and by the lamellar structure. The high exchange efficiency is guaranteed by the double circulation in counter flow. The exchanger is made of copper with a protective coating resistant to high temperatures. Secondary exchanger ACTA is available in a mixed version for heating and domestic hot water production: the hot water is supplied at an adjustable and constant temperature thanks to the electronic modulation of the boiler. The DHW exchanger is made of stainless steel and has a low inertia which guarantees excellent performance. Control panel Summer/winter/off selector Heating temperature regulator DHW temperature regulator Digital and analog pressure reading DHW and heating temperature visualization from the display Display of fault diagnostics, block status and fault history Recommended fill display Display annual periodic maintenance expiry Thermo-hydrometer for reading the water pressure on the primary side. Integration with solar ACTA can be easily combined with a solar system using the Biasi solar kit. Simple and immediate to install, it does not require electrical parts and allows optimizing the integration of the solar system with the boiler which intervenes only when necessary to guarantee the required comfort temperature. Reliability and security Hydraulic groups of innovative conception: Motorized 3-way valve Integrated automatic by-pass: allows the boiler to adapt to the needs of modern heating systems Absolute heating pressure switch: guarantees protection of the boiler in the event of a lack of water or circulation Sanitary flowmeter Easily accessible filling tap Drain tap Warranty The warranty on this item is 24 months from the date of purchase.
€613,00
Savio Gas Boiler Savio Acta E 28 A * LPG Open Chamber
SAVIO ACTA GAS BOILER AND 28 A* LPG OPEN CHAMBER Model: ACTA 28A Energy label specifications according to the European ErP directive Class C heating energy efficiency Sanitary Energy Efficiency Class B Withdrawal profile: XL Characteristics of heating/DHW operation: Heating/DHW nominal heat input: 30.6 kW Heating/DHW maximum useful power: 27.6 kW Yield name 60°/80°C: 90% Yield at 30% load: 89.3% Energy efficiency stars: (dir 92/42/EEC) ** NOx class n° 3 Weighted NOx: 148 mg/kWh Minimum/maximum heating temperature: 38/85 °C Minimum/maximum heating pressure: 0.3/3.0 bar Capacity of the expansion tank (total): 8lt DHW minimum/maximum temperature: 35/60°C Maximum flow rate (ΔT=25K) / (ΔT=35K): 15.8/11.3 l/min Specific sanitary flow rate (ΔT=30 K): 12.5 l/min Voltage / Power at nominal heat input V~/ W 230~/56 Degree of protection n° IPX4D Minimum/maximum smoke temperature: 83/108°C Extremely compact dimensions hxwxd: mm 703x400x325 ; 29.4kg CNG or LPG power supply ACTA NEW ACTA is the range of Savio boilers designed to meet modern housing needs that require reliable, compact and high performance products. The ACTA range includes open chamber boilers with powers of 24 kW and 28 kW. The ACTA series is suitable for heating and domestic hot water production. ACTA has very compact dimensions which make it easy to place in any environment. Characteristics: High yields Primary heat exchanger in copper, high circulation lamellar Sanitary plate heat exchanger in stainless steel High efficiency pump with low energy consumption Integration with SAVIO solar systems using a solar kit Digital control panel with display. The electronic card allows you to: Adjust the ignition pressure Adjust the restart frequency Manage the post-circulation of the high efficiency pump View fault diagnostics and lockout status. Also available: Boiler antifreeze safety Primary circuit thermal inertia disposal. Primary exchanger ACTA is a high efficiency boiler: the most compact exchanger, with reduced fin pitch to increase their number and ensure maximum efficiency. The large heat exchange surface is guaranteed by the helical section of the passage pipes and by the lamellar structure. The high exchange efficiency is guaranteed by the double circulation in counter flow. The exchanger is made of copper with a protective coating resistant to high temperatures. Secondary exchanger ACTA is available in a mixed version for heating and domestic hot water production: the hot water is supplied at an adjustable and constant temperature thanks to the electronic modulation of the boiler. The DHW exchanger is made of stainless steel and has a low inertia which guarantees excellent performance. Control panel Summer/winter/off selector Heating temperature regulator DHW temperature regulator Digital and analog pressure reading DHW and heating temperature visualization from the display Display of fault diagnostics, block status and fault history Recommended fill display Display annual periodic maintenance expiry Thermo-hydrometer for reading the water pressure on the primary side. Integration with solar ACTA can be easily combined with a solar system using the Biasi solar kit. Simple and immediate to install, it does not require electrical parts and allows optimizing the integration of the solar system with the boiler which intervenes only when necessary to guarantee the required comfort temperature. Reliability and security Hydraulic groups of innovative conception: Motorized 3-way valve Integrated automatic by-pass: allows the boiler to adapt to the needs of modern heating systems Absolute heating pressure switch: guarantees protection of the boiler in the event of a lack of water or circulation Sanitary flowmeter Easily accessible filling tap Drain tap Warranty The warranty on this item is 24 months from the date of purchase.
€613,00
Savio Gas Boiler Savio Acta E 24 A* Methane Open Chamber
SAVIO ACTA GAS BOILER AND 24 A* METHANE OPEN CHAMBER Model: ACTA 24A Energy label specifications according to the European ErP directive Class C heating energy efficiency Sanitary Energy Efficiency Class B Withdrawal profile: XL Characteristics of heating/DHW operation: Heating/DHW nominal heat input: 26.6 kW Heating/DHW maximum useful power: 24.1 kW Yield name 60°/80°C: 90.6% Yield at 30% load: 89.6% Energy efficiency stars: (dir 92/42/EEC) ** NOx class n° 3 Weighted NOx: 135 mg/kWh Minimum/maximum heating temperature: 38/85 °C Minimum/maximum heating pressure: 0.3/3.0 bar Capacity of the expansion tank (total): 8lt DHW minimum/maximum temperature: 35/60°C Maximum flow rate (ΔT=25K) / (ΔT=35K): 13.8/9.9 l/min Specific sanitary flow rate (ΔT=30 K): 11.5 l/min Voltage / Power at nominal heat input V~/ W 230~/56 Degree of protection n° IPX4D Minimum/maximum smoke temperature: 83/108°C Extremely compact dimensions hxwxd: mm 703x400x325 ; 28.7kg CNG or LPG power supply ACTA ACTA is the range of Savio boilers designed to meet modern housing needs that require reliable, compact and high performance products. The ACTA range includes open chamber boilers with powers of 24 kW and 28 kW. The ACTA series is suitable for heating and domestic hot water production. ACTA has very compact dimensions which make it easy to place in any environment. Characteristics: High yields Primary heat exchanger in copper, high circulation lamellar Sanitary plate heat exchanger in stainless steel High efficiency pump with low energy consumption Integration with SAVIO solar systems using a solar kit Digital control panel with display. The electronic card allows you to: - Adjust the ignition pressure - Adjust the restart frequency - Manage the post-circulation of the high efficiency pump - View fault diagnostics and lockout status. Also available: - Boiler antifreeze safety - Disposal of primary circuit thermal inertia. Primary exchanger ACTA is a high efficiency boiler: the most compact exchanger, with reduced fin pitch to increase their number and ensure maximum efficiency. The large heat exchange surface is guaranteed by the helical section of the passage pipes and by the lamellar structure. The high exchange efficiency is guaranteed by the double circulation in counter flow. The exchanger is made of copper with a protective coating resistant to high temperatures. Secondary exchanger ACTA is available in a mixed version for heating and domestic hot water production: the hot water is supplied at an adjustable and constant temperature thanks to the electronic modulation of the boiler. The DHW exchanger is made of stainless steel and has a low inertia which guarantees excellent performance. Control panel Summer/winter/off selector Heating temperature regulator DHW temperature regulator Digital and analog pressure reading DHW and heating temperature visualization from the display Display of fault diagnostics, block status and fault history Recommended fill display Display annual periodic maintenance expiry Thermo-hydrometer for reading the water pressure on the primary side. Integration with solar ACTA can be easily combined with a solar system using the Biasi solar kit. Simple and immediate to install, it does not require electrical parts and allows optimizing the integration of the solar system with the boiler which intervenes only when necessary to guarantee the required comfort temperature. Reliability and security Hydraulic groups of innovative conception: Motorized 3-way valve Integrated automatic by-pass: allows the boiler to adapt to the needs of modern heating systems Absolute heating pressure switch: guarantees protection of the boiler in the event of a lack of water or circulation Sanitary flowmeter Easily accessible filling tap Drain tap Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€659,00