icon Chiller heat pumps | CaldaieMurali

Chiller heat pumps

Our chiller heat pumps are the innovative energy solution for efficient heating and cooling of spaces. Take a look and discover the benefits today!

11 products


  • Sale -38%Last stock! immagine-1-baxi-offerta-pompa-di-calore-aria-acqua-monoblocco-inverter-baxi-auriga-5m-r-32-monofase-a7794318-completo-di-comando-novita

    BAXI Offer Baxi Auriga 5m R-32 Single-Phase Air-Water Monobloc Inverter A7794318 Complete With Control - New

    ATTENTION ! OFFER VALID UNTIL STOCKS LAST FIRST START UP INCLUDED! Technical features Thermal power (air +7°C (bs) / +6°C (bu) and delivery temperature of +35°C - EN 14511): 4.65 kW COP: 5.00 Cooling capacity (air +35°C (bs) and delivery temperature +7°C - EN 14511): 4.60 kW EER: 2.98 SEER: 4.71 R32 refrigerant charge: 2.00 kg Number/type of compressors: 1/rotary DC inverter Number of fans: 1 Nominal water flow (winter operation): 0.80 m³/h Circulation pump useful head: 55 kPa Inlet/outlet hydraulic connections: 1” male / 1” male Power supply voltage: 230V 1P+N+T Power supply frequency: 50Hz Overall dimensions H x W x D: 945mm x 1210mm x 402mm Weight: 92kg Sound power: 61dB(A) Sound pressure at 1 meter in free field on a reflective surface: 48.8 dB(A) BAXI AURIGA Inverter Monobloc Air-Water Heat Pumps Baxi introduces Auriga , the range of inverter packaged air-to-water heat pumps with single-phase and three-phase power supply. The range is characterized by the ease and simplicity of installation . Furthermore, the increased head of the on-board circulator allows the unit to be installed in large-scale systems, to cover greater distances from the heating plant or to install the unit directly to serve the fan coils. The range is wide and consists of 8 models from 4 to 16 kW, single-phase and three-phase versions Wide range of powers from 4 to 16 kW to satisfy all system requirements: heating, cooling and DHW production Easy to install in various living contexts, the increased head pump allows you to cope with greater pressure drops such as large systems or directly serving the fan coils STANDARD complete hydraulic equipment circulation pump, flow switch, expansion tank, safety valve, pressure gauge and “Y” filter Remote control panel control of system functions, programming and parameter verification. Furthermore, the connection via Modbus allows integration with BMS systems ErP Energy Labeling the labeling regulation (EU Regulation 2017/1369) requires the labeling of products according to a decreasing energy scale that goes from A+++ to D (in heating) and from A+ to F (in sanitary). The 5M/7M/9M models achieve an efficiency of A+++ in low temperature heating Components > Twin rotary DC inverter compressor : complete with internal thermal protection and crankcase heater, it is mounted on vibration dampers and wrapped around an insulating cap to reduce the transmission of noise and vibrations due to operation > Water-refrigerant exchanger : with brazed plates in AISI 316 steel with external anti-condensation insulation in expanded polypropylene and antifreeze resistance to prevent the formation of ice in the exchanger > Air-refrigerant exchanger : finned aluminum coil with hydrophilic treatment to facilitate the outflow of the condensate, mechanically expanded copper pipes with internal shaping to increase the heat exchange Furthermore, the optimized circuitry reduces the formation of ice in the coil during heat pump operation > Fan : axial fan directly coupled to the high efficiency brushless DC variable speed motor. The fan is installed on aerodynamic nozzles and safety grilles > Refrigerant circuit : made of pickled copper, it includes the electronic expansion valve, drier filters, high and low pressure switches, pressure transducer, cycle inversion valves, liquid receiver and separator, refrigerant injection valve on the suction side > Hydraulic circuit : in addition to the brazed plate heat exchanger, the unit includes the high head circulator, the expansion vessel, the safety valve, the flow switch, the pressure gauge and the air vent valve and the metal mesh Y-filter (assembly by the installer) > Electrical panel : includes fuse protection of the main internal components; the terminal block is divided into a power section for supplying the unit and a control terminal block for connecting auxiliary inputs and outputs and connection to the control panel Main Features BAXI AURIGA Maximum energy efficiency Monobloc system for the production of heating, cooling and DHW Wide operating range, with external air down to -25°C in heating, up to 46°C in cooling DHW system management: production up to 60°C, storage tank temperature management, DHW recirculation pump and solar thermal integration Suitable for integration with radiant terminals, fan coils and mixed systems Integrated management with various plant systems: boiler integration, solar integration, management of diverter valves and secondary circuit pump Single-phase and three-phase power supply Compressor with DC inverter technology with high modulation range Modbus network connection Low GWP R32 refrigerant Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €3.900,00€2.399,00

  • immagine-1-baxi-pompa-di-calore-aria-acqua-monoblocco-inverter-baxi-auriga-12t-a-r-32-trifase-a7794578-con-pannello-di-comando-remoto-incluso-novita

    BAXI Air-Water Heat Pump Monoblock Inverter Baxi Auriga 12t-A R-32 Three-Phase A7794578 With Remote Control Panel Included - New

    ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS FIRST START UP INCLUDED! Technical features Model : Auriga 12T-A Product code : A7794578 Remote Control Panel A7799122 Heating with low temperature application External air temperature 7°C - 87% RH Water temperature 30/35°C Nonimal thermal power: 12.10 kW Absorbed electrical power: 2.44 kW COP: 4.95 External air temperature 7°C - 87% RH Water temperature 35°C Normal thermal power: 10.00 kW Absorbed electrical power: 3.33 kW COP : 3.00 Heating with medium temperature application External air temperature 7°C - 87% RH Water temperature 45°C Nonimal thermal power: 12.30 kW Absorbed electrical power: 3.32 kW COP: 3.70 External air temperature 7°C - 87% RH Water temperature 55°C Nonimal thermal power: 11.90 kW Absorbed electrical power: 3.90 kW COP: 3.05 Cooling External air temperature 35°C - Water temperature 18°C Nonimal cooling capacity: 12.00 kW Absorbed electrical power: 3.04 kW EER: 3.95 External air temperature 35°C - Water temperature 7°C Nonimal cooling capacity: 11.50 kW Absorbed electrical power: 4.18 kW EER: 2.75 Energy efficiency Seasonal low-temperature space heating energy efficiency : 189% Seasonal space heating energy efficiency at medium temperature : 135% Low temperature seasonal energy efficiency class: A+++ Seasonal energy efficiency class at medium temperature: A++ Performance Exchanger water flow rate: 2.09 m 3 /h Available pump head: 60 kPa Sound power level : 65 dB(A) Sound pressure level : 53 dB(A) Electrical data Power supply (V,Hz, Ø) : 380~415/50/3 Refrigerant gas : R32 Operating limits Heating External air temperature : -25°C ~ 35°C Introduced water temperature : 12°C~ 65°C Cooling down External air temperature : -5°C ~ 43°C Introduced water temperature : 5°C ~ 25°C Installation data Plumbing pipe diameter: 1'' 1/4 Dimensions and weight Dimensions (HxWxD): 865x1385x488 mm Empty weight: 160 Kg BAXI AURIGA Inverter Monobloc Air-Water Heat Pumps introducing the new Auriga . The range is characterized by the ease and simplicity of installation, as well as for reliability and excellent performance . Furthermore, the high head of the circulator, fitted as STANDARD inside the unit, allows installation in large-sized systems, to cover greater distances from the boiler room or to install the unit directly at the service of the fan coils. The range expands and consists of well 8 models from 4 to 16 kW, single-phase and three-phase versions Wide range of powers from 4 to 16 kW to satisfy all system requirements: heating, cooling and DHW production. The power range is made up of the following sizes: 4, 6, 8, 10, 12 and 16 kW. Cascade Thanks to the new operating logics it is possible to install up to 6 units in cascade. By exploiting the modularity and redundancy of the generators, the system efficiently satisfies the requests of all plants. Complete hydraulic equipment as standard High head circulation pump, flow switch, expansion vessel (8L), safety valve, pressure gauge and "Y" strainer Remote control panel Control of system functions, programming and parameter verification. Furthermore, the possibility of connection via Modbus allows integration with BM systems Operating range Wide operating range, with operating temperatures in heating up to 65 °C ErP Energy Labeling The labeling regulation (EU Regulation 2017/1369) requires the labeling of products according to a decreasing energy scale that goes from A+++ to D (in heating) and from A+ to F (in sanitary). All models of the range (4M-A / 6M-A / 8M-A / 10M-A / 12M-A / 12T-A / 16M-A / 16T-A) reach an efficiency equal to A+++ in low temperature heating Components Twin rotary DC inverter compressor Complete with internal thermal protection and crankcase heater, mounted on anti-vibration rubbers and wound on an insulating hood to reduce the transmission of noise and vibrations due to operation Water-refrigerant exchanger With brazed plates in AISI 316 steel with external anti-condensation insulation in expanded polypropylene and anti-freeze resistance to prevent the formation of ice in the exchanger Air-refrigerant exchanger Aluminum finned coil with hydrophilic treatment to facilitate the flow of condensate, mechanically expanded copper pipes with internal shaping to increase heat exchange. Furthermore, the optimized circuitry reduces the formation of ice in the coil during heat pump operation Fan directly coupled to the high efficiency brushless DC variable speed motor. The fan is installed on aerodynamic nozzles and safety grilles Refrigerant circuit Made of pickled copper, it includes the electronic expansion valve, drier filters, high and low pressure switches, pressure transducer, cycle inversion valves, liquid receiver and separator, refrigerant injection valve on the suction side Hydraulic circuit In addition to the brazed plate heat exchanger, the unit includes the high head circulator, the expansion tank, the safety valve, the flow switch, the pressure gauge, the air vent valve and the metal mesh Y strainer (assembly by the installer) Electrical panel Includes fuse protection of the main internal components; the terminal board is divided into a power section for unit power supply and a control terminal board for connecting auxiliary inputs and outputs and connection to the control panel Main features Baxi Auriga Maximum energy efficiency Monobloc system for the production of heating, cooling and DHW Wide operating range, with external air down to -25°C in heating, up to 43°C in cooling DHW system management: production up to 65°C, storage tank temperature management, DHW recirculation pump and solar thermal integration Suitable for integration with radiant terminals, fan coils and mixed systems Integrated management with various plant systems: boiler integration, solar integration, management of diverter valves and secondary circuit pump Intelligent defrosting thanks to simultaneous monitoring of room temperature, coolant temperature, product water temperature and operating regime Compressor with DC inverter technology with high modulation range Modbus network connection low GWP refrigerant R32 Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €4.399,00

  • immagine-1-baxi-pompa-di-calore-aria-acqua-monoblocco-inverter-baxi-auriga-10m-a-r-32-monofase-a7794573-con-pannello-di-comando-remoto-incluso-novita

    BAXI Air-Water Heat Pump Monoblock Inverter Baxi Auriga 10m-A R-32 Single-Phase A7794573 With Remote Control Panel Included - New

    ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS FIRST START UP INCLUDED! Technical features Model : Auriga 10M-A Product code : A7794573 Remote Control Panel A7799122 Heating with low temperature application External air temperature 7°C - 87% RH Water temperature 30/35°C Nonimal thermal power: 10.00 kW Absorbed electrical power: 2.02 kW COP: 4.95 External air temperature 7°C - 87% RH Water temperature 35°C Thermal power: 8.00 kW Absorbed electrical power: 2.62 kW COP: 3.05 Heating with medium temperature application External air temperature 7°C - 87% RH Water temperature 45°C Nonimal thermal power: 10.00 kW Absorbed electrical power: 2.67 kW COP: 3.75 External air temperature 7°C - 87% RH Water temperature 55°C Nonimal thermal power: 9.50 kW Absorbed electrical power: 3.06 kW COP: 3.10 Cooling External air temperature 35°C - Water temperature 18°C Normal cooling capacity: 9.90 kW Absorbed electrical power: 2.18 kW EER: 4.55 External air temperature 35°C - Water temperature 7°C Normal cooling capacity: 8.20 kW Absorbed electrical power: 2.52 kW EER: 3.25 Energy efficiency Seasonal low-temperature space heating energy efficiency : 205% Seasonal space heating energy efficiency at medium temperature : 137% Low temperature seasonal energy efficiency class: A+++ Seasonal energy efficiency class at medium temperature: A++ Performance Exchanger water flow rate: 1.73 m 3 /h Available pump head: 70 kPa Sound power level : 60 dB(A) Sound pressure level : 50.5 dB(A) Electrical data Power supply (V,Hz, Ø) : 220~240/50/1 Refrigerant gas : R32 Operating limits Heating External air temperature : -25°C ~ 35°C Introduced water temperature : 12°C~ 65°C Cooling down External air temperature : -5°C ~ 43°C Introduced water temperature : 5°C ~ 25°C Installation data Plumbing pipe diameter: 1'' 1/4 Dimensions and weight Dimensions (HxWxD): 865x1385x488 mm Empty weight: 121 Kg BAXI AURIGA Inverter Monobloc Air-Water Heat Pumps introducing the new Auriga . The range is characterized by the ease and simplicity of installation, as well as for reliability and excellent performance . Furthermore, the high head of the circulator, fitted as STANDARD inside the unit, allows installation in large-sized systems, to cover greater distances from the boiler room or to install the unit directly at the service of the fan coils. The range expands and consists of well 8 models from 4 to 16 kW, single-phase and three-phase versions Wide range of powers from 4 to 16 kW to satisfy all system requirements: heating, cooling and DHW production. The power range is made up of the following sizes: 4, 6, 8, 10, 12 and 16 kW. Cascade Thanks to the new operating logics it is possible to install up to 6 units in cascade. By exploiting the modularity and redundancy of the generators, the system efficiently satisfies the requests of all plants. Complete hydraulic equipment as standard High head circulation pump, flow switch, expansion vessel (8L), safety valve, pressure gauge and "Y" strainer Remote control panel Control of system functions, programming and parameter verification. Furthermore, the possibility of connection via Modbus allows integration with BM systems Operating range Wide operating range, with operating temperatures in heating up to 65 °C ErP Energy Labeling The labeling regulation (EU Regulation 2017/1369) requires the labeling of products according to a decreasing energy scale that goes from A+++ to D (in heating) and from A+ to F (in sanitary). All models of the range (4M-A / 6M-A / 8M-A / 10M-A / 12M-A / 12T-A / 16M-A / 16T-A) reach an efficiency equal to A+++ in low temperature heating Components Twin rotary DC inverter compressor Complete with internal thermal protection and crankcase heater, mounted on anti-vibration rubbers and wound on an insulating hood to reduce the transmission of noise and vibrations due to operation Water-refrigerant exchanger With brazed plates in AISI 316 steel with external anti-condensation insulation in expanded polypropylene and anti-freeze resistance to prevent the formation of ice in the exchanger Air-refrigerant exchanger Aluminum finned coil with hydrophilic treatment to facilitate the flow of condensate, mechanically expanded copper pipes with internal shaping to increase heat exchange. Furthermore, the optimized circuitry reduces the formation of ice in the coil during heat pump operation Fan directly coupled to the high efficiency brushless DC variable speed motor. The fan is installed on aerodynamic nozzles and safety grilles Refrigerant circuit Made of pickled copper, it includes the electronic expansion valve, drier filters, high and low pressure switches, pressure transducer, cycle inversion valves, liquid receiver and separator, refrigerant injection valve on the suction side Hydraulic circuit In addition to the brazed plate heat exchanger, the unit includes the high head circulator, the expansion tank, the safety valve, the flow switch, the pressure gauge, the air vent valve and the metal mesh Y strainer (assembly by the installer) Electrical panel Includes fuse protection of the main internal components; the terminal board is divided into a power section for unit power supply and a control terminal board for connecting auxiliary inputs and outputs and connection to the control panel Main features Baxi Auriga Maximum energy efficiency Monobloc system for the production of heating, cooling and DHW Wide operating range, with external air down to -25°C in heating, up to 43°C in cooling DHW system management: production up to 65°C, storage tank temperature management, DHW recirculation pump and solar thermal integration Suitable for integration with radiant terminals, fan coils and mixed systems Integrated management with various plant systems: boiler integration, solar integration, management of diverter valves and secondary circuit pump Intelligent defrosting thanks to simultaneous monitoring of room temperature, coolant temperature, product water temperature and operating regime Compressor with DC inverter technology with high modulation range Modbus network connection low GWP refrigerant R32 Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €4.100,00

  • immagine-1-baxi-pompa-di-calore-aria-acqua-monoblocco-inverter-baxi-auriga-6m-a-r-32-monofase-a7794571-con-pannello-di-comando-remoto-incluso-novita

    BAXI Air-Water Heat Pump Monoblock Inverter Baxi Auriga 6m-A R-32 Single-Phase A7794571 With Remote Control Panel Included - New

    ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS FIRST START UP INCLUDED! Technical features Model : Auriga 6M-A Product code : A7794571 Remote Control Panel A7799122 Heating with low temperature application External air temperature 7°C - 87% RH Water temperature 30/35°C Nonimal thermal power: 6.35 kW Absorbed electrical power: 1.28 kW COP: 4.95 External air temperature 7°C - 87% RH Water temperature 35°C Normal thermal power: 6.00 kW Absorbed electrical power: 2.00 kW COP : 3.00 Heating with medium temperature application External air temperature 7°C - 87% RH Water temperature 45°C Nonimal thermal power: 6.30 kW Absorbed electrical power: 1.70 kW COP: 3.70 External air temperature 7°C - 87% RH Water temperature 55°C Nonimal thermal power: 6.00 kW Absorbed electrical power: 2.03 kW COP : 2.95 Cooling External air temperature 35°C - Water temperature 18°C Nonimal cooling capacity: 6.50 kW Absorbed electrical power: 1.35 kW EER: 4.80 External air temperature 35°C - Water temperature 7°C Nonimal cooling capacity: 7.00 kW Absorbed electrical power: 2.33 kW EER: 3.00 Energy efficiency Seasonal low-temperature space heating energy efficiency : 195% Seasonal space heating energy efficiency at medium temperature : 138% Low temperature seasonal energy efficiency class: A+++ Seasonal energy efficiency class at medium temperature: A++ Performance Exchanger water flow rate: 1.10 m 3 /h Available pump head: 83 kPa Sound power level : 58 dB(A) Sound pressure level : 47.5 dB(A) Electrical data Power supply (V,Hz, Ø) : 220~240/50/1 Refrigerant gas : R32 Operating limits Heating External air temperature : -25°C ~ 35°C Introduced water temperature : 12°C~ 65°C Cooling down External air temperature : -5°C ~ 43°C Introduced water temperature : 5°C ~ 25°C Installation data Hydraulic Pipe Diameter: 1" Dimensions and weight Dimensions (HxWxD): 718x1295x401 mm Empty weight : 98 Kg BAXI AURIGA Inverter Monobloc Air-Water Heat Pumps introducing the new Auriga . The range is characterized by the ease and simplicity of installation, as well as for reliability and excellent performance . Furthermore, the high head of the circulator, fitted as STANDARD inside the unit, allows installation in large-sized systems, to cover greater distances from the boiler room or to install the unit directly at the service of the fan coils. The range expands and consists of well 8 models from 4 to 16 kW, single-phase and three-phase versions Wide range of powers from 4 to 16 kW to satisfy all system requirements: heating, cooling and DHW production. The power range is made up of the following sizes: 4, 6, 8, 10, 12 and 16 kW. Cascade Thanks to the new operating logics it is possible to install up to 6 units in cascade. By exploiting the modularity and redundancy of the generators, the system efficiently satisfies the requests of all plants. Complete hydraulic equipment as standard High head circulation pump, flow switch, expansion vessel (8L), safety valve, pressure gauge and "Y" strainer Remote control panel Control of system functions, programming and parameter verification. Furthermore, the possibility of connection via Modbus allows integration with BM systems Operating range Wide operating range, with operating temperatures in heating up to 65 °C ErP Energy Labeling The labeling regulation (EU Regulation 2017/1369) requires the labeling of products according to a decreasing energy scale that goes from A+++ to D (in heating) and from A+ to F (in sanitary). All models of the range (4M-A / 6M-A / 8M-A / 10M-A / 12M-A / 12T-A / 16M-A / 16T-A) reach an efficiency equal to A+++ in low temperature heating Components Twin rotary DC inverter compressor Complete with internal thermal protection and crankcase heater, mounted on anti-vibration rubbers and wound on an insulating hood to reduce the transmission of noise and vibrations due to operation Water-refrigerant exchanger With brazed plates in AISI 316 steel with external anti-condensation insulation in expanded polypropylene and anti-freeze resistance to prevent the formation of ice in the exchanger Air-refrigerant exchanger Aluminum finned coil with hydrophilic treatment to facilitate the flow of condensate, mechanically expanded copper pipes with internal shaping to increase heat exchange. Furthermore, the optimized circuitry reduces the formation of ice in the coil during heat pump operation Fan directly coupled to the high efficiency brushless DC variable speed motor. The fan is installed on aerodynamic nozzles and safety grilles Refrigerant circuit Made of pickled copper, it includes the electronic expansion valve, drier filters, high and low pressure switches, pressure transducer, cycle inversion valves, liquid receiver and separator, refrigerant injection valve on the suction side Hydraulic circuit In addition to the brazed plate heat exchanger, the unit includes the high head circulator, the expansion tank, the safety valve, the flow switch, the pressure gauge, the air vent valve and the metal mesh Y strainer (assembly by the installer) Electrical panel Includes fuse protection of the main internal components; the terminal board is divided into a power section for unit power supply and a control terminal board for connecting auxiliary inputs and outputs and connection to the control panel Main features Baxi Auriga Maximum energy efficiency Monobloc system for the production of heating, cooling and DHW Wide operating range, with external air down to -25°C in heating, up to 43°C in cooling DHW system management: production up to 65°C, storage tank temperature management, DHW recirculation pump and solar thermal integration Suitable for integration with radiant terminals, fan coils and mixed systems Integrated management with various plant systems: boiler integration, solar integration, management of diverter valves and secondary circuit pump Intelligent defrosting thanks to simultaneous monitoring of room temperature, coolant temperature, product water temperature and operating regime Compressor with DC inverter technology with high modulation range Modbus network connection low GWP refrigerant R32 Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €3.000,00

  • immagine-1-baxi-pompa-di-calore-aria-acqua-monoblocco-inverter-baxi-auriga-16t-a-r-32-trifase-a7794581-con-pannello-di-comando-remoto-incluso-novita

    BAXI Air-Water Heat Pump Monoblock Inverter Baxi Auriga 16t-A R-32 Three-Phase A7794581 With Remote Control Panel Included - New

    ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS FIRST START UP INCLUDED! Technical features Model : Auriga 16T-A Product code : A7794581 Remote Control Panel A7799122 Heating with low temperature application External air temperature 7°C - 87% RH Water temperature 30/35°C Nonimal thermal power: 15.90 kW Absorbed electrical power: 3.53 kW COP: 4.50 External air temperature 7°C - 87% RH Water temperature 35°C Thermal power: 13.10 kW Absorbed electrical power: 4.85 kW COP : 2.70 Heating with medium temperature application External air temperature 7°C - 87% RH Water temperature 45°C Nonimal thermal power: 16.00 kW Absorbed electrical power: 4.57 kW COP : 3.50 External air temperature 7°C - 87% RH Water temperature 55°C Nonimal thermal power: 16.00 kW Absorbed electrical power: 5.61 kW COP: 2.85 Cooling External air temperature 35°C - Water temperature 18°C Normal cooling capacity: 14.20 kW Absorbed electrical power: 3.93 kW EER: 3.61 External air temperature 35°C - Water temperature 7°C Nonimal cooling capacity: 14.00 kW Absorbed electrical power: 5.60 kW EER: 2.50 Energy efficiency Seasonal low-temperature space heating energy efficiency : 189% Seasonal space heating energy efficiency at medium temperature : 133% Low temperature seasonal energy efficiency class: A+++ Seasonal energy efficiency class at medium temperature: A++ Performance Exchanger water flow rate: 2.75 m 3 /h Available pump head: 40 kPa Sound power level : 68 dB(A) Sound pressure level : 58 dB(A) Electrical data Power supply (V,Hz, Ø) : 380~415/50/3 Refrigerant gas : R32 Operating limits Heating External air temperature : -25°C ~ 35°C Introduced water temperature : 12°C~ 65°C Cooling down External air temperature : -5°C ~ 43°C Introduced water temperature : 5°C ~ 25°C Installation data Plumbing pipe diameter: 1'' 1/4 Dimensions and weight Dimensions (HxWxD): 865x1385x488 mm Empty weight: 160 Kg BAXI AURIGA Inverter Monobloc Air-Water Heat Pumps introducing the new Auriga . The range is characterized by the ease and simplicity of installation, as well as for reliability and excellent performance . Furthermore, the high head of the circulator, fitted as STANDARD inside the unit, allows installation in large-sized systems, to cover greater distances from the boiler room or to install the unit directly at the service of the fan coils. The range expands and consists of well 8 models from 4 to 16 kW, single-phase and three-phase versions Wide range of powers from 4 to 16 kW to satisfy all system requirements: heating, cooling and DHW production. The power range is made up of the following sizes: 4, 6, 8, 10, 12 and 16 kW. Cascade Thanks to the new operating logics it is possible to install up to 6 units in cascade. By exploiting the modularity and redundancy of the generators, the system efficiently satisfies the requests of all plants. Complete hydraulic equipment as standard High head circulation pump, flow switch, expansion vessel (8L), safety valve, pressure gauge and "Y" strainer Remote control panel Control of system functions, programming and parameter verification. Furthermore, the possibility of connection via Modbus allows integration with BM systems Operating range Wide operating range, with operating temperatures in heating up to 65 °C ErP Energy Labeling The labeling regulation (EU Regulation 2017/1369) requires the labeling of products according to a decreasing energy scale that goes from A+++ to D (in heating) and from A+ to F (in sanitary). All models of the range (4M-A / 6M-A / 8M-A / 10M-A / 12M-A / 12T-A / 16M-A / 16T-A) reach an efficiency equal to A+++ in low temperature heating Components Twin rotary DC inverter compressor Complete with internal thermal protection and crankcase heater, mounted on anti-vibration rubbers and wound on an insulating hood to reduce the transmission of noise and vibrations due to operation Water-refrigerant exchanger With brazed plates in AISI 316 steel with external anti-condensation insulation in expanded polypropylene and anti-freeze resistance to prevent the formation of ice in the exchanger Air-refrigerant exchanger Aluminum finned coil with hydrophilic treatment to facilitate the flow of condensate, mechanically expanded copper pipes with internal shaping to increase heat exchange. Furthermore, the optimized circuitry reduces the formation of ice in the coil during heat pump operation Fan directly coupled to the high efficiency brushless DC variable speed motor. The fan is installed on aerodynamic nozzles and safety grilles Refrigerant circuit Made of pickled copper, it includes the electronic expansion valve, drier filters, high and low pressure switches, pressure transducer, cycle inversion valves, liquid receiver and separator, refrigerant injection valve on the suction side Hydraulic circuit In addition to the brazed plate heat exchanger, the unit includes the high head circulator, the expansion tank, the safety valve, the flow switch, the pressure gauge, the air vent valve and the metal mesh Y strainer (assembly by the installer) Electrical panel Includes fuse protection of the main internal components; the terminal board is divided into a power section for unit power supply and a control terminal board for connecting auxiliary inputs and outputs and connection to the control panel Main features Baxi Auriga Maximum energy efficiency Monobloc system for the production of heating, cooling and DHW Wide operating range, with external air down to -25°C in heating, up to 43°C in cooling DHW system management: production up to 65°C, storage tank temperature management, DHW recirculation pump and solar thermal integration Suitable for integration with radiant terminals, fan coils and mixed systems Integrated management with various plant systems: boiler integration, solar integration, management of diverter valves and secondary circuit pump Intelligent defrosting thanks to simultaneous monitoring of room temperature, coolant temperature, product water temperature and operating regime Compressor with DC inverter technology with high modulation range Modbus network connection low GWP refrigerant R32 Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €5.860,00

  • immagine-1-baxi-pompa-di-calore-aria-acqua-monoblocco-inverter-baxi-auriga-12m-a-r-32-monofase-a7794574-con-pannello-di-comando-remoto-incluso-novita

    BAXI Air-Water Heat Pump Monoblock Inverter Baxi Auriga 12m-A R-32 Single-Phase A7794574 With Remote Control Panel Included - New

    ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS FIRST START UP INCLUDED! Technical features Model : Auriga 12M-A Product code : A7794574 Remote Control Panel A7799122 Heating with low temperature application External air temperature 7°C - 87% RH Water temperature 30/35°C Nonimal thermal power: 12.10 kW Absorbed electrical power: 2.44 kW COP: 4.95 External air temperature 7°C - 87% RH Water temperature 35°C Normal thermal power: 10.00 kW Absorbed electrical power: 3.33 kW COP : 3.00 Heating with medium temperature application External air temperature 7°C - 87% RH Water temperature 45°C Nonimal thermal power: 12.30 kW Absorbed electrical power: 3.32 kW COP: 3.70 External air temperature 7°C - 87% RH Water temperature 55°C Nonimal thermal power: 11.90 kW Absorbed electrical power: 3.90 kW COP: 3.05 Cooling External air temperature 35°C - Water temperature 18°C Nonimal cooling capacity: 12.00 kW Absorbed electrical power: 3.04 kW EER: 3.95 External air temperature 35°C - Water temperature 7°C Nonimal cooling capacity: 11.50 kW Absorbed electrical power: 4.18 kW EER: 2.75 Energy efficiency Seasonal low-temperature space heating energy efficiency : 189% Seasonal space heating energy efficiency at medium temperature : 135% Low temperature seasonal energy efficiency class: A+++ Seasonal energy efficiency class at medium temperature: A++ Performance Exchanger water flow rate: 2.09 m 3 /h Available pump head: 60 kPa Sound power level : 65 dB(A) Sound pressure level : 53 dB(A) Electrical data Power supply (V,Hz, Ø) : 220~240/50/1 Refrigerant gas : R32 Operating limits Heating External air temperature : -25°C ~ 35°C Introduced water temperature : 12°C~ 65°C Cooling down External air temperature : -5°C ~ 43°C Introduced water temperature : 5°C ~ 25°C Installation data Plumbing pipe diameter: 1'' 1/4 Dimensions and weight Dimensions (HxWxD): 865x1385x488 mm Empty weight: 144 Kg BAXI AURIGA Inverter Monobloc Air-Water Heat Pumps introducing the new Auriga . The range is characterized by the ease and simplicity of installation, as well as for reliability and excellent performance . Furthermore, the high head of the circulator, fitted as STANDARD inside the unit, allows installation in large-sized systems, to cover greater distances from the boiler room or to install the unit directly at the service of the fan coils. The range expands and consists of well 8 models from 4 to 16 kW, single-phase and three-phase versions Wide range of powers from 4 to 16 kW to satisfy all system requirements: heating, cooling and DHW production. The power range is made up of the following sizes: 4, 6, 8, 10, 12 and 16 kW. Cascade Thanks to the new operating logics it is possible to install up to 6 units in cascade. By exploiting the modularity and redundancy of the generators, the system efficiently satisfies the requests of all plants. Complete hydraulic equipment as standard High head circulation pump, flow switch, expansion vessel (8L), safety valve, pressure gauge and "Y" strainer Remote control panel Control of system functions, programming and parameter verification. Furthermore, the possibility of connection via Modbus allows integration with BM systems Operating range Wide operating range, with operating temperatures in heating up to 65 °C ErP Energy Labeling The labeling regulation (EU Regulation 2017/1369) requires the labeling of products according to a decreasing energy scale that goes from A+++ to D (in heating) and from A+ to F (in sanitary). All models of the range (4M-A / 6M-A / 8M-A / 10M-A / 12M-A / 12T-A / 16M-A / 16T-A) reach an efficiency equal to A+++ in low temperature heating Components Twin rotary DC inverter compressor Complete with internal thermal protection and crankcase resistance, mounted on anti-vibration rubbers and wound on an insulating hood to reduce the transmission of noise and vibrations due to operation Water-refrigerant exchanger With brazed plates in AISI 316 steel with external anti-condensation insulation in expanded polypropylene and anti-freeze resistance to prevent the formation of ice in the exchanger Air-refrigerant exchanger Aluminum finned coil with hydrophilic treatment to facilitate the flow of condensate, mechanically expanded copper pipes with internal shaping to increase heat exchange. Furthermore, the optimized circuitry reduces the formation of ice in the coil during heat pump operation Fan directly coupled to the high efficiency brushless DC variable speed motor. The fan is installed on aerodynamic nozzles and safety grilles Refrigerant circuit Made of pickled copper, it includes the electronic expansion valve, drier filters, high and low pressure switches, pressure transducer, cycle inversion valves, liquid receiver and separator, refrigerant injection valve on the suction side Hydraulic circuit In addition to the brazed plate heat exchanger, the unit includes the high head circulator, the expansion tank, the safety valve, the flow switch, the pressure gauge, the air vent valve and the metal mesh Y strainer (assembly by the installer) Electrical panel Includes fuse protection of the main internal components; the terminal board is divided into a power section for unit power supply and a control terminal board for connecting auxiliary inputs and outputs and connection to the control panel Main features Baxi Auriga Maximum energy efficiency Monobloc system for the production of heating, cooling and DHW Wide operating range, with external air down to -25°C in heating, up to 43°C in cooling DHW system management: production up to 65°C, storage tank temperature management, DHW recirculation pump and solar thermal integration Suitable for integration with radiant terminals, fan coils and mixed systems Integrated management with various plant systems: boiler integration, solar integration, management of diverter valves and secondary circuit pump Intelligent defrosting thanks to simultaneous monitoring of room temperature, coolant temperature, product water temperature and operating regime Compressor with DC inverter technology with high modulation range Modbus network connection low GWP refrigerant R32 Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €4.238,00

  • immagine-1-baxi-pompa-di-calore-aria-acqua-monoblocco-inverter-baxi-auriga-8m-a-r-32-monofase-a7794572-con-pannello-di-comando-remoto-incluso-novita

    BAXI Air-Water Heat Pump Monoblock Inverter Baxi Auriga 8m-A R-32 Single-Phase A7794572 With Remote Control Panel Included - New

    ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS FIRST START UP INCLUDED! Technical features Model : Auriga 8M-A Product code : A7794572 Remote Control Panel A7799122 Heating with low temperature application External air temperature 7°C - 87% RH Water temperature 30/35°C Nonimal thermal power: 8.40 kW Absorbed electrical power: 1.63 kW COP: 5.15 External air temperature 7°C - 87% RH Water temperature 35°C Normal thermal power: 7.00 kW Absorbed electrical power: 2.19 kW COP: 3.20 Heating with medium temperature application External air temperature 7°C - 87% RH Water temperature 45°C Nonimal thermal power: 8.10 kW Absorbed electrical power: 2.10 kW COP: 3.85 External air temperature 7°C - 87% RH Water temperature 55°C Nonimal thermal power: 7.50 kW Absorbed electrical power: 2.36 kW COP: 3.18 Cooling External air temperature 35°C - Water temperature 18°C Normal cooling capacity: 8.30 kW Absorbed electrical power: 1.64 kW EER: 5.05 External air temperature 35°C - Water temperature 7°C Nonimal cooling capacity: 7.45 kW Absorbed electrical power: 2.22 kW EER: 3.35 Energy efficiency Seasonal low-temperature space heating energy efficiency : 206% Seasonal space heating energy efficiency at medium temperature : 132% Low temperature seasonal energy efficiency class: A+++ Seasonal energy efficiency class at medium temperature: A++ Performance Exchanger water flow rate: 1.45 m 3 /h Available pump head: 78 kPa Sound power level : 59 dB(A) Sound pressure level : 48.5 dB(A) Electrical data Power supply (V,Hz, Ø) : 220~240/50/1 Refrigerant gas : R32 Operating limits Heating External air temperature : -25°C ~ 35°C Introduced water temperature : 12°C~ 65°C Cooling down External air temperature : -5°C ~ 43°C Introduced water temperature : 5°C ~ 25°C Installation data Plumbing pipe diameter: 1'' 1/4 Dimensions and weight Dimensions (HxWxD): 865x1385x488 mm Empty weight: 121 Kg BAXI AURIGA Inverter Monobloc Air-Water Heat Pumps introducing the new Auriga . The range is characterized by the ease and simplicity of installation, as well as for reliability and excellent performance . Furthermore, the high head of the circulator, fitted as STANDARD inside the unit, allows installation in large-sized systems, to cover greater distances from the boiler room or to install the unit directly at the service of the fan coils. The range expands and consists of well 8 models from 4 to 16 kW, single-phase and three-phase versions Wide range of powers from 4 to 16 kW to satisfy all system requirements: heating, cooling and DHW production. The power range is made up of the following sizes: 4, 6, 8, 10, 12 and 16 kW. Cascade Thanks to the new operating logics it is possible to install up to 6 units in cascade. By exploiting the modularity and redundancy of the generators, the system efficiently satisfies the requests of all plants. Complete hydraulic equipment as standard High head circulation pump, flow switch, expansion vessel (8L), safety valve, pressure gauge and "Y" strainer Remote control panel Control of system functions, programming and parameter verification. Furthermore, the possibility of connection via Modbus allows integration with BM systems Operating range Wide operating range, with operating temperatures in heating up to 65 °C ErP Energy Labeling The labeling regulation (EU Regulation 2017/1369) requires the labeling of products according to a decreasing energy scale that goes from A+++ to D (in heating) and from A+ to F (in sanitary). All models of the range (4M-A / 6M-A / 8M-A / 10M-A / 12M-A / 12T-A / 16M-A / 16T-A) reach an efficiency equal to A+++ in low temperature heating Components Twin rotary DC inverter compressor Complete with internal thermal protection and crankcase heater, mounted on anti-vibration rubbers and wound on an insulating hood to reduce the transmission of noise and vibrations due to operation Water-refrigerant exchanger With brazed plates in AISI 316 steel with external anti-condensation insulation in expanded polypropylene and anti-freeze resistance to prevent the formation of ice in the exchanger Air-refrigerant exchanger Aluminum finned coil with hydrophilic treatment to facilitate the flow of condensate, mechanically expanded copper pipes with internal shaping to increase heat exchange. Furthermore, the optimized circuitry reduces the formation of ice in the coil during heat pump operation Fan directly coupled to the high efficiency brushless DC variable speed motor. The fan is installed on aerodynamic nozzles and safety grilles Refrigerant circuit Made of pickled copper, it includes the electronic expansion valve, drier filters, high and low pressure switches, pressure transducer, cycle inversion valves, liquid receiver and separator, refrigerant injection valve on the suction side Hydraulic circuit In addition to the brazed plate heat exchanger, the unit includes the high head circulator, the expansion tank, the safety valve, the flow switch, the pressure gauge, the air vent valve and the metal mesh Y strainer (assembly by the installer) Electrical panel Includes fuse protection of the main internal components; the terminal board is divided into a power section for unit power supply and a control terminal board for connecting auxiliary inputs and outputs and connection to the control panel Main features Baxi Auriga Maximum energy efficiency Monobloc system for the production of heating, cooling and DHW Wide operating range, with external air down to -25°C in heating, up to 43°C in cooling DHW system management: production up to 65°C, storage tank temperature management, DHW recirculation pump and solar thermal integration Suitable for integration with radiant terminals, fan coils and mixed systems Integrated management with various plant systems: boiler integration, solar integration, management of diverter valves and secondary circuit pump Intelligent defrosting thanks to simultaneous monitoring of room temperature, coolant temperature, product water temperature and operating regime Compressor with DC inverter technology with high modulation range Modbus network connection low GWP refrigerant R32 Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €3.400,00

  • immagine-1-baxi-pompa-di-calore-aria-acqua-monoblocco-inverter-baxi-auriga-4m-a-r-32-monofase-a7794318-con-pannello-di-comando-remoto-incluso-novita

    BAXI Air-Water Heat Pump Monoblock Inverter Baxi Auriga 4m-A R-32 Single-Phase A7794318 With Remote Control Panel Included - New

    ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS FIRST START UP INCLUDED! Technical features Model : Auriga 4M-A Product code : A7794318 Remote Control Panel A7799122 Heating with low temperature application External air temperature 7°C - 87% RH Water temperature 30/35°C Nonimal thermal power: 4.20 kW Absorbed electrical power: 0.82 kW COP: 5.10 External air temperature 7°C - 87% RH Water temperature 35°C Thermal power: 4.70 kW Absorbed electrical power: 1.52 kW COP: 3.10 Heating with medium temperature application External air temperature 7°C - 87% RH Water temperature 45°C Nonimal thermal power: 4.30 kW Absorbed electrical power: 1.13 kW COP: 3.80 External air temperature 7°C - 87% RH Water temperature 55°C Nonimal thermal power: 4.40 kW Absorbed electrical power: 1.49 kW COP : 2.95 Cooling External air temperature 35°C - Water temperature 18°C Nonimal cooling capacity: 4.50 kW Absorbed electrical power: 0.82 kW EER: 5.50 External air temperature 35°C - Water temperature 7°C Normal cooling capacity: 4.70 kW Absorbed electrical power: 1.36 kW EER: 3.45 Energy efficiency Seasonal low-temperature space heating energy efficiency : 191% Seasonal space heating energy efficiency at medium temperature : 130% Low temperature seasonal energy efficiency class: A+++ Seasonal energy efficiency class at medium temperature: A++ Performance Exchanger water flow rate: 0.73 m 3 /h Available pump head: 85 kPa Sound power level : 55 dB(A) Sound pressure level : 45 dB(A) Electrical data Power supply (V,Hz, Ø) : 220~240/50/1 Refrigerant gas : R32 Operating limits Heating External air temperature : -25°C ~ 35°C Introduced water temperature : 12°C~ 65°C Cooling down External air temperature : -5°C ~ 43°C Introduced water temperature : 5°C ~ 25°C Installation data Hydraulic Pipe Diameter: 1" Dimensions and weight Dimensions (HxWxD): 718x1295x401 mm Empty weight : 98 Kg BAXI AURIGA Inverter Monobloc Air-Water Heat Pumps introducing the new Auriga . The range is characterized by the ease and simplicity of installation, as well as for reliability and excellent performance . Furthermore, the high head of the circulator, fitted as STANDARD inside the unit, allows installation in large-sized systems, to cover greater distances from the boiler room or to install the unit directly at the service of the fan coils. The range expands and consists of well 8 models from 4 to 16 kW, single-phase and three-phase versions Wide range of powers from 4 to 16 kW to satisfy all system requirements: heating, cooling and DHW production. The power range is made up of the following sizes: 4, 6, 8, 10, 12 and 16 kW. Cascade Thanks to the new operating logics it is possible to install up to 6 units in cascade. By exploiting the modularity and redundancy of the generators, the system efficiently satisfies the requests of all plants. Complete hydraulic equipment as standard High head circulation pump, flow switch, expansion vessel (8L), safety valve, pressure gauge and "Y" strainer Remote control panel Control of system functions, programming and parameter verification. Furthermore, the possibility of connection via Modbus allows integration with BM systems Operating range Wide operating range, with operating temperatures in heating up to 65 °C ErP Energy Labeling The labeling regulation (EU Regulation 2017/1369) requires the labeling of products according to a decreasing energy scale that goes from A+++ to D (in heating) and from A+ to F (in sanitary). All models of the range (4M-A / 6M-A / 8M-A / 10M-A / 12M-A / 12T-A / 16M-A / 16T-A) reach an efficiency equal to A+++ in low temperature heating Components Twin rotary DC inverter compressor Complete with internal thermal protection and crankcase heater, mounted on anti-vibration rubbers and wound on an insulating hood to reduce the transmission of noise and vibrations due to operation Water-refrigerant exchanger With brazed plates in AISI 316 steel with external anti-condensation insulation in expanded polypropylene and anti-freeze resistance to prevent the formation of ice in the exchanger Air-refrigerant exchanger Aluminum finned coil with hydrophilic treatment to facilitate the flow of condensate, mechanically expanded copper pipes with internal shaping to increase heat exchange. Furthermore, the optimized circuitry reduces the formation of ice in the coil during heat pump operation Fan directly coupled to the high efficiency brushless DC variable speed motor. The fan is installed on aerodynamic nozzles and safety grilles Refrigerant circuit Made of pickled copper, it includes the electronic expansion valve, drier filters, high and low pressure switches, pressure transducer, cycle inversion valves, liquid receiver and separator, refrigerant injection valve on the suction side Hydraulic circuit In addition to the brazed plate heat exchanger, the unit includes the high head circulator, the expansion tank, the safety valve, the flow switch, the pressure gauge, the air vent valve and the metal mesh Y strainer (assembly by the installer) Electrical panel Includes fuse protection of the main internal components; the terminal board is divided into a power section for unit power supply and a control terminal board for connecting auxiliary inputs and outputs and connection to the control panel Main features Baxi Auriga Maximum energy efficiency Monobloc system for the production of heating, cooling and DHW Wide operating range, with external air down to -25°C in heating, up to 43°C in cooling DHW system management: production up to 65°C, storage tank temperature management, DHW recirculation pump and solar thermal integration Suitable for integration with radiant terminals, fan coils and mixed systems Integrated management with various plant systems: boiler integration, solar integration, management of diverter valves and secondary circuit pump Intelligent defrosting thanks to simultaneous monitoring of room temperature, coolant temperature, product water temperature and operating regime Compressor with DC inverter technology with high modulation range Modbus network connection low GWP refrigerant R32 Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €2.700,00

  • immagine-1-baxi-pompa-di-calore-aria-acqua-monoblocco-inverter-baxi-auriga-16m-a-r32-monofase-a7794577-con-pannello-di-comando-remoto-incluso-novita

    BAXI Air-Water Heat Pump Monoblock Inverter Baxi Auriga 16m-A R32 Single-Phase A7794577 With Remote Control Panel Included - New

    ATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED IN 10 WORKING DAYS FIRST START UP INCLUDED! Technical features Model : Auriga 16T-A Product code : A7794577 Remote Control Panel A7799122 Heating with low temperature application External air temperature 7°C - 87% RH Water temperature 30/35°C Nonimal thermal power: 15.90 kW Absorbed electrical power: 3.53 kW COP: 4.50 External air temperature 7°C - 87% RH Water temperature 35°C Thermal power: 13.10 kW Absorbed electrical power: 4.85 kW COP : 2.70 Heating with medium temperature application External air temperature 7°C - 87% RH Water temperature 45°C Nonimal thermal power: 16.00 kW Absorbed electrical power: 4.57 kW COP : 3.50 External air temperature 7°C - 87% RH Water temperature 55°C Nonimal thermal power: 16.00 kW Absorbed electrical power: 5.61 kW COP: 2.85 Cooling External air temperature 35°C - Water temperature 18°C Nonimal cooling capacity: 14.20 kW Absorbed electrical power: 3.93 kW EER: 3.61 External air temperature 35°C - Water temperature 7°C Nonimal cooling capacity: 14.00 kW Absorbed electrical power: 5.60 kW EER: 2.50 Energy efficiency Seasonal low-temperature space heating energy efficiency : 189% Seasonal space heating energy efficiency at medium temperature : 133% Low temperature seasonal energy efficiency class: A+++ Seasonal energy efficiency class at medium temperature: A++ Performance Exchanger water flow rate: 2.75 m 3 /h Available pump head: 40 kPa Sound power level : 68 dB(A) Sound pressure level : 58 dB(A) Electrical data Power supply (V,Hz, Ø) : 220~240/50/1 Refrigerant gas : R32 Operating limits Heating External air temperature : -25°C ~ 35°C Introduced water temperature : 12°C~ 65°C Cooling down External air temperature : -5°C ~ 43°C Introduced water temperature : 5°C ~ 25°C Installation data Plumbing pipe diameter: 1'' 1/4 Dimensions and weight Dimensions (HxWxD): 865x1385x488 mm Empty weight: 144 Kg BAXI AURIGA Inverter Monobloc Air-Water Heat Pumps introducing the new Auriga . The range is characterized by the ease and simplicity of installation, as well as for reliability and excellent performance . Furthermore, the high head of the circulator, fitted as STANDARD inside the unit, allows installation in large-sized systems, to cover greater distances from the boiler room or to install the unit directly at the service of the fan coils. The range expands and consists of well 8 models from 4 to 16 kW, single-phase and three-phase versions Wide range of powers from 4 to 16 kW to satisfy all system requirements: heating, cooling and DHW production. The power range is made up of the following sizes: 4, 6, 8, 10, 12 and 16 kW. Cascade Thanks to the new operating logics it is possible to install up to 6 units in cascade. By exploiting the modularity and redundancy of the generators, the system efficiently satisfies the requests of all plants. Complete hydraulic equipment as standard High head circulation pump, flow switch, expansion vessel (8L), safety valve, pressure gauge and "Y" strainer Remote control panel Control of system functions, programming and parameter verification. Furthermore, the possibility of connection via Modbus allows integration with BM systems Operating range Wide operating range, with operating temperatures in heating up to 65 °C ErP Energy Labeling The labeling regulation (EU Regulation 2017/1369) requires the labeling of products according to a decreasing energy scale that goes from A+++ to D (in heating) and from A+ to F (in sanitary). All models of the range (4M-A / 6M-A / 8M-A / 10M-A / 12M-A / 12T-A / 16M-A / 16T-A) reach an efficiency equal to A+++ in low temperature heating Components Twin rotary DC inverter compressor Complete with internal thermal protection and crankcase heater, mounted on anti-vibration rubbers and wound on an insulating hood to reduce the transmission of noise and vibrations due to operation Water-refrigerant exchanger With brazed plates in AISI 316 steel with external anti-condensation insulation in expanded polypropylene and anti-freeze resistance to prevent the formation of ice in the exchanger Air-refrigerant exchanger Aluminum finned coil with hydrophilic treatment to facilitate the flow of condensate, mechanically expanded copper pipes with internal shaping to increase heat exchange. Furthermore, the optimized circuitry reduces the formation of ice in the coil during heat pump operation Fan directly coupled to the high efficiency brushless DC variable speed motor. The fan is installed on aerodynamic nozzles and safety grilles Refrigerant circuit Made of pickled copper, it includes the electronic expansion valve, drier filters, high and low pressure switches, pressure transducer, cycle inversion valves, liquid receiver and separator, refrigerant injection valve on the suction side Hydraulic circuit In addition to the brazed plate heat exchanger, the unit includes the high head circulator, the expansion tank, the safety valve, the flow switch, the pressure gauge, the air vent valve and the metal mesh Y strainer (assembly by the installer) Electrical panel Includes fuse protection of the main internal components; the terminal board is divided into a power section for unit power supply and a control terminal board for connecting auxiliary inputs and outputs and connection to the control panel Main features Baxi Auriga Maximum energy efficiency Monobloc system for the production of heating, cooling and DHW Wide operating range, with external air down to -25°C in heating, up to 43°C in cooling DHW system management: production up to 65°C, storage tank temperature management, DHW recirculation pump and solar thermal integration Suitable for integration with radiant terminals, fan coils and mixed systems Integrated management with various plant systems: boiler integration, solar integration, management of diverter valves and secondary circuit pump Intelligent defrosting thanks to simultaneous monitoring of room temperature, coolant temperature, product water temperature and operating regime Compressor with DC inverter technology with high modulation range Modbus network connection low GWP refrigerant R32 Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €5.621,00

  • immagine-1-baxi-offerta-pompa-di-calore-aria-acqua-monoblocco-inverter-baxi-auriga-16m-r32-monofase-con-pannello-di-comando-remoto-incluso

    BAXI Baxi AURIGA 16M R32 Inverter Monobloc Air-Water Heat Pump Single Phase with Remote Control Panel Included

    VALID WHILE STOCKS LAST FIRST START-UP INCLUDED! Technical features Model : Auriga 16M Remote control panel A7750381 Heating with low temperature application Outside air temperature 7°C87% RH Water temperature 30/35°C Nominal thermal power: 16.30 kW COP : 4.45 Outside air temperature 7°C87% RH Water temperature 40/45°C Nominal thermal power: 16.20 kW COP : 3.43 Heating with medium temperature application Outside air temperature 7°C87% RH Water temperature 47/55°C Nominal thermal power: 16.10 kW COP : 2.73 Cooling Outside air temperature 35°CWater temperature 23/18°C Nominal cooling capacity: 15.50 kW EER : 4.26 Outside air temperature 35°CWater temperature 7°C Nominal cooling capacity: 13.80 kW EER : 2.65 Energy efficiency Seasonal low temperature space heating energy efficiency: 169% Seasonal energy efficiency of medium temperature space heating: 128% Seasonal low temperature energy efficiency class: A+++ Seasonal energy efficiency class at medium temperature: A++ Performance Exchanger water flow rate: 2.82 m3 /h Pump useful head: 62 kPa Sound power level: 71 dB(A) Sound pressure level: 58.1 dB(A) Electrical data Power supply (V,Hz,Ø) : 220~240/50/1 Refrigerant gas: R32 Installation data Hydraulic pipe diameter: 1'' 1/4 Dimensions and weight Dimensions (HxWxD): 1414x1404x373 mm Empty weight: 158.0 Kg Monobloc Inverter Air-Water Heat Pumps BAXI AURIGA Baxi introduces Auriga , the new range of monobloc inverter air-water heat pumps with single-phase and three-phase power supply. The range is characterised by ease and simplicity of installation . Furthermore, the increased prevalence of the on-board circulator allows the unit to be installed in large systems, covering greater distances from the heating plant or installing the unit directly to serve the fan coils. The range is wide and consists of 7 models from 5 to 16 kW, single-phase and three-phase versions . Wide range of power from 5 to 16 kW to satisfy all system needs: heating, cooling and DHW production Easy to install in various living contexts The increased head pump allows you to deal with greater pressure drops such as large systems or directly serving fan coils. Remote control panel Allows control of system functions, programming and parameter verification. Furthermore, the Modbus connection allows integration with BMS systems. Components Twin rotary DC inverter compressor complete with internal thermal protection and crankcase resistance, it is mounted on anti-vibration rubbers and wrapped on an insulating casing to reduce the transmission of noise and vibrations due to operation Brazed plate water-coolant exchanger in AISI 316 steel with external anti-condensation insulation in expanded polypropylene and anti-freeze resistance to prevent ice formation in the exchanger Air-refrigerant exchanger finned aluminium battery with hydrophilic treatment to facilitate the flow of condensation, mechanically expanded copper tubes with internal shaping to increase heat exchange. Furthermore, the optimised circuitry allows for a reduction in ice formation in the battery during heat pump operation. Axial fan fan directly coupled to the variable speed brushless DC motor with high efficiency. The fan is installed on aerodynamic nozzles and safety grilles Refrigeration circuit made of pickled copper, includes the electronic expansion valve, dehydrating filters, high and low pressure switches, pressure transducer, cycle reversal valves, liquid receiver and separator, refrigerant injection valve in suction Hydraulic circuit in addition to the brazed plate exchanger, the unit includes the high-head circulator, the expansion vessel, the safety valve, the flow switch, the pressure gauge and the air vent valve and the metal mesh Y-filter, assembly by the installer Electrical panel includes fuse protection of the main internal components; the terminal block is divided into a power section for powering the unit and a control terminal block for connecting auxiliary inputs and outputs and connection to the control panel Baxi Auriga Maximum energy efficiency Monoblock system for the production of heating, cooling and DHW Wide operating range, with external air up to -25°C in heating, up to 46°C in cooling ACS system management: production up to 60°C, boiler temperature management, ACS recirculation pump and solar thermal integration Suitable for integration with radiant terminals, fan coils and mixed systems Integrated management with different system systems: boiler integration, solar integration, diverter valve management and secondary circuit pump Intelligent defrosting thanks to the simultaneous monitoring of ambient temperature, refrigerant temperature, produced water temperature and operating mode Compressor with DC inverter technology with high modulation range Modbus network connection Low GWP R-32 refrigerant Standard control functions Control panel to manage different system configurations directly from the unit Heating and cooling management with 16 different climate curves per mode ACS boiler management, solar integration, boiler and ACS recirculation pump management Boiler integration management and backup electric resistance Anti-legionella function Eco mode with double adjustable setpoint Silent mode with 2 adjustable silence levels Holiday mode: antifreeze and DHW management with dedicated setpoints and anti-legionella treatment on DHW at the end of the set mode Product Warranty: All products for sale on our site are new and packaged. The warranty on this item is 24 months from the date of purchase.

    €4.300,00

  • immagine-1-baxi-pompa-di-calore-aria-acqua-monoblocco-inverter-baxi-auriga-12t-r-32-trifase-a7749310-con-pannello-di-comando-remoto-incluso

    BAXI Air-Water Heat Pump Monoblock Inverter Baxi Auriga 12t R-32 Three-Phase A7749310 With Remote Control Panel Included

    ATTENTION ! OFFER VALID UNTIL STOCKS LAST FIRST START UP INCLUDED! Technical features Model : Auriga 12T Product code : A7749310 Remote Control Panel A7750381 Heating External air temperature 7°C - 87% RH Water temperature 30/35°C Nonimal Thermal Power: 12.30 kW Absorbed electrical power: 2.54 kW COP: 4.84 External air temperature 7°C - 87% RH Water temperature 45°C Nonimal Thermal Power: 12.10 kW Absorbed electrical power: 3.39 kW COP: 3.57 External air temperature 7°C - 87% RH Water temperature 47/55°C Nonimal thermal power: 11.90 kW Absorbed electrical power: 4.23 kW COP: 2.81 Cooling External air temperature 35°C - Water temperature 23/18°C Normal cooling capacity: 12.20 kW Absorbed electrical power: 2.60 kW EER: 4.78 External air temperature 35°C - Water temperature 12/7°C Normal cooling capacity: 10.90 kW Absorbed electrical power: 3.70 kW EER: 2.92 Energy efficiency Seasonal Energy Efficiency of low temperature space heating : 169% Seasonal Energy Efficiency of medium temperature space heating : 126% Seasonal Energy Efficiency Class at low temperature: A+++ Seasonal Energy Efficiency Class at medium temperature: A++ Performance Exchanger water flow rate: 2.13 m 3 /h Available pump head: 80 kPa Sound power level : 68 dB(A) Sound pressure level : 57.2 dB(A) Electrical data Power supply (V,Hz, Ø) : 380~415/50/3 Refrigerant gas : R32 Installation data Plumbing pipe diameter: 1" 1/4 Dimensions and weight Dimensions (HxWxD): 1414x1404x405 mm Empty weight: 172 Kg BAXI AURIGA Inverter Monobloc Air-Water Heat Pumps Baxi introduces Auriga , the range of inverter packaged air-to-water heat pumps with single-phase and three-phase power supply. The range is characterized by the ease and simplicity of installation . Furthermore, the increased head of the on-board circulator allows the unit to be installed in large-sized systems, to cover greater distances from the boiler room or to install the unit directly at the service of the fan coils. The range is wide and consists of 8 models from 4 to 16 kW, single-phase and three-phase versions Wide range of powers from 4 to 16 kW to satisfy all system requirements: heating, cooling and DHW production Easy to install in various living contexts, the increased head pump allows you to cope with greater pressure drops such as large systems or directly serving the fan coils STANDARD complete hydraulic equipment circulation pump, flow switch, expansion tank, safety valve, pressure gauge and “Y” filter Remote control panel control of system functions, programming and parameter verification. Furthermore, the connection via Modbus allows integration with BMS systems ErP Energy Labeling the labeling regulation (EU Regulation 2017/1369) requires the labeling of products according to a decreasing energy scale that goes from A+++ to D (in heating) and from A+ to F (in sanitary). The 5M/7M/9M models achieve an efficiency of A+++ in low temperature heating Components > Twin rotary DC inverter compressor : complete with internal thermal protection and crankcase heater, it is mounted on vibration dampers and wrapped around an insulating cap to reduce the transmission of noise and vibrations due to operation > Water-refrigerant exchanger : with brazed plates in AISI 316 steel with external anti-condensation insulation in expanded polypropylene and antifreeze resistance to prevent the formation of ice in the exchanger > Air-refrigerant exchanger : finned aluminum coil with hydrophilic treatment to facilitate the outflow of the condensate, mechanically expanded copper pipes with internal shaping to increase the heat exchange. Furthermore, the optimized circuitry allows to reduce the formation of ice in the coil during heat pump operation > Fan : axial fan directly coupled to the high efficiency brushless DC variable speed motor. The fan is installed on aerodynamic nozzles and safety grilles > Refrigerant circuit : made of pickled copper, it includes the electronic expansion valve, drier filters, high and low pressure switches, pressure transducer, cycle inversion valves, liquid receiver and separator, refrigerant injection valve on the suction side > Hydraulic circuit : in addition to the brazed plate heat exchanger, the unit includes the high head circulator, the expansion vessel, the safety valve, the flow switch, the pressure gauge and the air vent valve and the metal mesh Y-filter (assembly by the installer) > Electrical panel : includes fuse protection of the main internal components; the terminal block is divided into a power section for supplying the unit and a control terminal block for connecting auxiliary inputs and outputs and connection to the control panel Main Features BAXI AURIGA Maximum energy efficiency Monobloc system for the production of heating, cooling and DHW Wide operating range, with external air down to -25°C in heating, up to 46°C in cooling DHW system management: production up to 60°C, storage tank temperature management, DHW recirculation pump and solar thermal integration Suitable for integration with radiant terminals, fan coils and mixed systems Integrated management with various plant systems: boiler integration, solar integration, management of diverter valves and secondary circuit pump Single-phase and three-phase power supply Compressor with DC inverter technology with high modulation range Modbus network connection Low GWP R32 refrigerant Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.

    €5.265,00

Recently viewed products

Login

Forgot your password?

Don't have an account yet?
Create account