icon Ferroli | CaldaieMurali

Ferroli

Ferroli

Discover our exclusive selection of Atlas Filters, perfect for enriching your home or workspace with style, comfort and functionality. Each piece is chosen to guarantee the best quality and satisfy your every need.

184 products


  • immagine-1-ferroli-pompa-di-calore-splittata-reversibile-aria-acqua-inverter-ferroli-omnia-st-3.2-08-sistema-con-integrazione-elettrica-r-32-con-comando-incluso

    Ferroli Air-Water Reversible Split Heat Pump Inverter Ferroli Omnia St 3.2 08 System With R-32 Electrical Integration With Control Included

    ATTENTION! IN CASE OF UNAVAILABILITY IMMEDIATELY, THE PRODUCT WILL BE ORDERED AND SHIPPED WITHIN 10 WORKING DAYS   FIRST START-UP FREE Technical Features Model : OMNIA S 3.2 08 Product Code : 0XHT8SWA Command included Optional accessories CONNECT CRP remote control Performance Heating Useful power in heating with water set at 35° C: 8.40 kW Useful power in heating with water set at 45° C: 8.30 kW Useful power in heating with water set at 55° C: 7.50 kW Power absorbed with water set at 35°C: 1.63 kW Power absorbed with water set at 45°C: 2.16 kW Power absorbed with water set at 55°C: 2.36 kW Water flow rate with water set at 35°C: 1445 l/h Water flow rate with water set at 45°C: 1428 /h Water flow rate with water set at 55°C: 806 l/h Cooling Useful power in cooling with water set at 7 °C: 7.45 kW Useful power in cooling with water set at 18 °C: 8.30 kW Power absorbed with water set at 7° C: 2.22 kW Power absorbed with water set at 18°C: 1.64 kW Water flow rate with water set at 7°C: 1281 l/h Water flow rate with water set at 18°C: 1428 l/h Technical data of external unit Compressor type : Twin Rotary DC Number of compressors : 1 Number of refrigeration circuits: 1 Fan type : DC Axial Number of fans: 1 Sound power level in heating : 55 ~ 61 dB(A) Sound power level in cooling : 54 ~ 61 dB(A) Liquid pipe diameter: 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Maximum pipe length: 30 m Maximum pipe height difference: 20 m Technical data of the internal unit Exchanger type: Brazed stainless steel plates Expansion vessel volume: 10 litres Water safety valve calibration: 3 bar Minimum system water content: 40 litres System pipe diameter: 1" gas F Diameter of ACS pipes: 3/4" gas F Liquid pipe diameter: 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Electrical Data Power supply (V,Hz,Ø) : 220~240/50/1 Refrigerant gas: R32 Dimensions and Weight External unit dimensions (WxHxD): 1118x865x523 mm External unit weight: 77.0 Kg Internal unit dimensions (WxHxD): 595x1860x700 mm 5 years without worries Ferroli OMNIA ST 3.2 Reversible air-water heat pumps for split installation, with integrated DHW storage Efficiency meets comfort for integrated storage OMNIA ST 3.2 is the evolution of OMNIA S 3.2 and is part of the new range of Full Inverter R32 split heat pumps by Ferroli. When we talk about “split” we mean that the refrigeration circuit is divided between the two units, the external one and the internal one. The external unit contains the heart of the refrigeration circuit, from the compressor to the fan with the air side exchanger, which is connected with the refrigerant gas pipes to the internal unit. The internal unit contains the heart of the generator's hydraulic circuit with all the main pre-installed components, such as the high-efficiency circulator and the expansion vessel, to allow for safe, practical and fast installation. The OMNIA ST 3.2 differs from the OMNIA S 3.2 in having an accumulation tank for Domestic Hot Water integrated directly into the internal unit. This accumulation is 190L for sizes 4 to 10, while it is 240L for the larger ones, from 12 to 16T. But not only that, OMNIA ST 3.2 can be customized according to your needs, with an 18L inertial kit, a kit for solar integration on the accumulation or with a kit for the management of 2 different zones, classic direct and mixed, in case we need 2 different temperatures on the terminals in the house Thanks to its wide operating range , among the widest on the market, OMNIA ST 3.2 works down to -25°C external and produces hot water up to 65°C in nominal conditions. The new Full Inverter concept by Ferroli uses DC inverter modulations on the 3 main energy-intensive components of the machine, namely compressor, fan and pump. This allows the power supplied to be modulated by finely tracking the thermal load and allowing the user very high efficiencies and significant energy savings . Furthermore, the Full Inverter concept by Ferroli allows the inrush currents to be reduced, avoiding surges in the network and guaranteeing a longer useful life for the components. With noise levels among the lowest on the market , OMNIA ST 3.2 is able to satisfy all system requirements, but can easily be integrated with a Ferroli boiler . The internal unit, the heart of the hydraulic distribution If the external unit contains the heart of the refrigeration circuit, the Internal Unit contains the heart of the hydraulic circuit. OMNIA ST 3.2 is much more than an exchanger with a pump. The hydronic module includes all the main components of the system and can be customized according to the user's needs. Stainless steel plate exchanger, pressure gauge and pressure sensors, expansion vessel, safety valve, automatic vent and brushless DC circulator are just some of the components you will find inside. The control system The User Interface has been equipped with Capsense technology with 2.8” graphic display, which allows the user to interact with the product in an easy and extremely simple way Modbus protocol It can be interfaced with BMS/BACS automation and management systems Heating and cooling Full Inverter modulation finely follows the desired setpoints, with the possibility of setting climatic curves in heating and cooling, further optimising the user's consumption Domestic hot water production When the DHW Temperature probe calls the machine it automatically diverts to the domestic hot water boiler with a dedicated DHW Setpoint. 3-way diverter valve supplied as standard Smart Grid Inputs from photovoltaic and grid Digital Smart Grid inputs for managing an input from a photovoltaic system and from the electricity grid. These allow you to optimise consumption and costs on your bill Electric heating element for ACS boiler The ACS electric integration serves as an integration, anti-legionella or reserve source in the event of an anomaly Fast ACS Priority to DHW production to bring the boiler to the setpoint in the shortest possible time Anti-legionella function Allows you to set weekly anti-legionella cycles Silent mode Reduces the compressor frequency and fan speed, thus significantly reducing noise. Programmable on time slots ON/OFF From external contact. Activation and deactivation via an external contact, for example from a zone thermostat Hot / cold From external contacts. Summer/winter switching signal from outside, e.g. from the zone thermostat ECO function Dedicated setpoint for “ Eco ” operation. Can be set with daily time slot Antifreeze protection Heat pump operation in heating mode with circulator ON and possible electric booster The brand new Connect CRP and Connect CRP Zone The on-board interface communicates easily with the new intelligent Connect CRP systems, which can manage up to 8 thermostats divided into 2 zones, one direct and one mixed . Connect CRP is the brand new remote controller accessible via APP , available for both iOS and Android . The Connect CRP Zone is a zone thermostat that communicates via RF with the Connect CRP. It can be inserted into a classic 502 box, or left stand-alone on its practical table feet. Product Warranty: All products for sale on our site are new and packaged. The warranty on this item is 24 months from the date of purchase.

    €5.200,00

  • immagine-1-ferroli-pompa-di-calore-splittata-reversibile-aria-acqua-inverter-ferroli-omnia-st-3.2-06-sistema-con-integrazione-elettrica-r-32-con-comando-incluso

    Ferroli Air-Water Reversible Split Heat Pump Inverter Ferroli Omnia St 3.2 06 System With R-32 Electrical Integration With Control Included

    ATTENTION! IN CASE OF UNAVAILABILITY IMMEDIATELY, THE PRODUCT WILL BE ORDERED AND SHIPPED WITHIN 10 WORKING DAYS   FIRST START-UP FREE Technical Features Model : OMNIA S 3.2 06 Product Code : 0XHT6SWA Command included Optional accessories CONNECT CRP remote control Performance Heating Useful power in heating with water set at 35° C: 6.35 kW Useful power in heating with water set at 45° C: 6.30 kW Useful power in heating with water set at 55° C: 6.00 kW Power absorbed with water set at 35° C: 1.28 kW Power absorbed with water set at 45°C: 1.70 kW Power absorbed with water set at 55°C: 2.03 kW Water flow rate with water set at 35°C: 1092 l/h Water flow rate with water set at 45°C: 1074 /h Water flow rate with water set at 55°C: 645 l/h Cooling Useful power in cooling with water set at 7 °C: 6.50 kW Useful power in cooling with water set at 18 °C: 6.50 kW Power absorbed with water set at 7° C: 2.17 kW Power absorbed with water set at 18°C: 1.35 kW Water flow rate with water set at 7°C: 1118 l/h Water flow rate with water set at 18°C: 1118 l/h Technical data of external unit Compressor type : Twin Rotary DC Number of compressors : 1 Number of refrigeration circuits: 1 Fan type : DC Axial Number of fans: 1 Sound power level in heating mode : 53 ~ 61 dB(A) Sound power level in cooling : 54 ~ 61 dB(A) Liquid pipe diameter: 6.35 mm (1/4") Gas pipe diameter: 15.88 (5/8") Maximum pipe length: 30 m Maximum pipe height difference: 20 m Technical data of the internal unit Exchanger type: Brazed stainless steel plates Expansion vessel volume: 10 litres Water safety valve calibration: 3 bar Minimum system water content: 40 litres System pipe diameter: 1" gas F Diameter of ACS pipes: 3/4" gas F Liquid pipe diameter: 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Electrical Data Power supply (V,Hz,Ø) : 220~240/50/1 Refrigerant gas: R32 Dimensions and Weight External unit dimensions (WxHxD): 1008x712x426 mm External unit weight: 58.0 Kg Internal unit dimensions (WxHxD): 595x1860x700 mm 5 years without worries Ferroli OMNIA ST 3.2 Reversible air-water heat pumps for split installation, with integrated DHW storage Efficiency meets comfort for integrated storage OMNIA ST 3.2 is the evolution of OMNIA S 3.2 and is part of the new range of Full Inverter R32 split heat pumps by Ferroli. When we talk about “split” we mean that the refrigeration circuit is divided between the two units, the external one and the internal one. The external unit contains the heart of the refrigeration circuit, from the compressor to the fan with the air side exchanger, which is connected with the refrigerant gas pipes to the internal unit. The internal unit contains the heart of the generator's hydraulic circuit with all the main pre-installed components, such as the high-efficiency circulator and the expansion vessel, to allow for safe, practical and fast installation. The OMNIA ST 3.2 differs from the OMNIA S 3.2 in having an accumulation tank for Domestic Hot Water integrated directly into the internal unit. This accumulation is 190L for sizes 4 to 10, while it is 240L for the larger ones, from 12 to 16T. But not only that, OMNIA ST 3.2 can be customized according to your needs, with an 18L inertial kit, a kit for solar integration on the accumulation or with a kit for the management of 2 different zones, classic direct and mixed, in case we need 2 different temperatures on the terminals in the house Thanks to its wide operating range , among the widest on the market, OMNIA ST 3.2 works down to -25°C external and produces hot water up to 65°C in nominal conditions. The new Full Inverter concept by Ferroli uses DC inverter modulations on the 3 main energy-consuming components of the machine, i.e. compressor, fan and pump. This allows the power supplied to be modulated by finely tracking the thermal load and allowing the user very high efficiencies and significant energy savings . Furthermore, the Full Inverter concept by Ferroli allows the inrush currents to be reduced, avoiding surges in the network and guaranteeing a longer useful life for the components. With noise levels among the lowest on the market , OMNIA ST 3.2 is able to satisfy all system requirements, but can easily be integrated with a Ferroli boiler . The internal unit, the heart of the hydraulic distribution If the external unit contains the heart of the refrigeration circuit, the Internal Unit contains the heart of the hydraulic circuit. OMNIA ST 3.2 is much more than an exchanger with a pump. The hydronic module includes all the main components of the system and can be customized according to the user's needs. Stainless steel plate exchanger, pressure gauge and pressure sensors, expansion vessel, safety valve, automatic vent and brushless DC circulator are just some of the components you will find inside. The control system The User Interface has been equipped with Capsense technology with 2.8” graphic display, which allows the user to interact with the product in an easy and extremely simple way Modbus protocol It can be interfaced with BMS/BACS automation and management systems Heating and cooling Full Inverter modulation finely follows the desired setpoints, with the possibility of setting climatic curves in heating and cooling, further optimising the user's consumption Domestic hot water production When the DHW Temperature probe calls the machine it automatically diverts to the domestic hot water boiler with a dedicated DHW Setpoint. 3-way diverter valve supplied as standard Smart Grid Inputs from photovoltaic and grid Digital Smart Grid inputs for managing an input from a photovoltaic system and from the electricity grid. These allow you to optimise consumption and costs on your bill Electric heating element for ACS boiler The ACS electric integration serves as an integration, anti-legionella or reserve source in the event of an anomaly Fast ACS Priority to DHW production to bring the boiler to the setpoint in the shortest possible time Anti-legionella function Allows you to set weekly anti-legionella cycles Silent mode Reduces the compressor frequency and fan speed, thus significantly reducing noise. Programmable on time slots ON/OFF From external contact. Activation and deactivation via an external contact, for example from a zone thermostat Hot / cold From external contacts. Summer/winter switching signal from outside, e.g. from the zone thermostat ECO function Dedicated setpoint for “ Eco ” operation. Can be set with daily time slot Antifreeze protection Heat pump operation in heating mode with circulator ON and possible electric booster The brand new Connect CRP and Connect CRP Zone The on-board interface communicates easily with the new intelligent Connect CRP systems, which can manage up to 8 thermostats divided into 2 zones, one direct and one mixed . Connect CRP is the brand new remote controller accessible via APP , available for both iOS and Android . The Connect CRP Zone is a zone thermostat that communicates via RF with the Connect CRP. It can be inserted into a classic 502 box, or left stand-alone on its practical table feet. Product Warranty: All products for sale on our site are new and packaged. The warranty on this item is 24 months from the date of purchase.

    €5.000,00

  • immagine-1-ferroli-pompa-di-calore-reversibile-aria-acqua-inverter-ferroli-omnia-s-3.2-16-monofase-r-32-con-comando-incluso

    Ferroli Reversible Air-Water Inverter Heat Pump Ferroli OMNIA S 3.2 16 Single Phase R-32 with Control Included

    ATTENTION! IN CASE OF UNAVAILABILITY IMMEDIATELY, THE PRODUCT WILL BE ORDERED AND SHIPPED WITHIN 10 WORKING DAYS   FIRST START-UP FREE Technical Features Model : OMNIA S 3.2 16 Product Code : 0XHKGSWA Command included Optional accessories Unpainted built-in cabinet 016092X0 Painted built-in wardrobe 016093X0 Optional accessories Unpainted built-in cabinet 016092X0 Painted built-in wardrobe 016093X0 Energy Efficiency Energy class in heating at 35° C: A+++ Energy class in heating at 55° C: A++ SCOP heating with water set to 35 °C: 4.62 SEER cooling with water set at 7 °C: 4.69 Performance   Heating Useful power in heating with water set at 35° C: 15.9 kW Useful power in heating with water set at 45° C: 16.0 kW Useful power in heating with water set at 55° C: 16.0 kW Power absorbed with water set at 35°C: 3.53 kW Power absorbed with water set at 45°C: 4.57 kW Power absorbed with water set at 55°C: 5.61 kW Water flow rate with water set at 35°C: 2735 l/h Water flow rate with water set at 45°C: 2752 /h Water flow rate with water set at 55°C: 1720 l/h Cooling Useful power in cooling with water set at 7 °C: 14.0 kW Useful power in cooling with water set at 18 °C: 13.6 kW Power absorbed with water set at 7° C: 5.60 kW Power absorbed with water set at 18°C: 3.77 kW Water flow rate with water set at 7°C: 2408 l/h Water flow rate with water set at 18°C: 2563 l/h Technical data of external unit Compressor type : Twin Rotary DC Number of compressors : 1 Number of refrigeration circuits: 1 Fan type : DC Axial Number of fans: 1 Sound power level in heating mode : 56 ~ 69 dB(A) Sound power level in cooling : 56 ~ 69 dB(A) Liquid pipe diameter: 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Maximum pipe length: 30 m Maximum pipe height difference: 20 m Technical data of the internal unit Exchanger type: Brazed stainless steel plates Expansion vessel volume: 10 litres Water safety valve calibration: 3 bar Minimum system water content: 40 litres System pipe diameter: 1" gas F Diameter of ACS pipes: 3/4" gas F Liquid pipe diameter: 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Electrical Data Power supply (V,Hz,Ø) : 220~240/50/1 Refrigerant gas: R32 Dimensions and Weight External unit dimensions (WxHxD): 1118x865x523 mm External unit weight: 96.0 Kg Internal unit dimensions (WxHxD): 422x702x320 mm 5 years without worries Ferroli OMNIA S 3.2 Reversible heat pumps for split installation with DC inverter compressor Silence, efficiency and design OMNIA S 3.2 is the new range of split heat pumps Full Inverter R32 by Ferroli. The range includes an External Unit with the heart of the refrigeration circuit, from the compressor to the fan with the air-side exchanger, which is connected to the refrigerant gas pipes towards the Internal Unit. The Internal Unit instead contains the heart of the generator's hydraulic circuit with all the main pre-installed components, such as the high-efficiency circulator and the expansion vessel, to allow safe, practical and fast installation The split installation of OMNIA S 3.2 , with only gas pipes between the external and internal unit, is synonymous with safety with respect to any freezing problem, even at the most rigid temperatures (up to -25°C) and in the absence of electricity. All the units satisfy the most extreme winter and summer air conditioning needs, in fact they can produce hot water up to 65°C , which makes them suitable for practically all heating systems, whether radiant, fan coil or radiator, including the production of domestic hot water (DHW), via an external boiler The new concept Ferroli Full Inverter uses DC inverter modulations on the 3 main energy-consuming components of the machine, namely compressor, fan and pump. This allows the power supplied to be modulated by finely tracking the thermal load and allowing the user extremely high efficiencies and significant energy savings . Furthermore, the concept Ferroli Full Inverter guarantees noise levels among the lowest on the market, avoiding power surges and guaranteeing a longer useful life for the components. Internal and external unit of OMNIA 3.2 The External Unit contains the heart of the refrigeration circuit, while the Internal Unit the heart of the hydraulic circuit. They are connected to each other by pipes ecological refrigerant gas R32 , which has allowed us to combine high efficiency with a reduced environmental impact. Thanks to its GWP of 675 , about a third of the GWP of R410a, helps reduce CO2 equivalent emissions, the main cause of global warming The heat pumps they use the External Unit to extract heat from the air outside the home and convey it to the water in your system, via an exchanger in the Internal Unit. This is precisely why they are able to obtain such high efficiencies , exploiting in a way renewable the energy already present in the air outside the home The new concept Ferroli Full Inverter then does the rest, tracking the thermal loads precisely and without waste (modulating the compressor, pump and fan), managing to achieve even greater efficiencies, guaranteeing significant savings on your bill , without stressing your components and with very low noise levels OMNIA S 3.2 it can be used either as the only generator in the system or integrated with other sources such as a Ferroli boiler The control system The User Interface has been equipped with Capsense technology with 2.8” graphic display, which allows the user to interact with the product in an easy and extremely simple way Modbus protocol It can be interfaced with BMS/BACS automation and management systems Heating and cooling Full Inverter modulation finely follows the desired setpoints, with the possibility of setting climatic curves in heating and cooling, further optimising the user's consumption Domestic hot water production When the DHW Temperature probe calls the machine it automatically diverts to the domestic hot water boiler with a dedicated DHW Setpoint. 3-way diverter valve supplied as standard Smart Grid Inputs from photovoltaic and grid Digital Smart Grid inputs for managing an input from a photovoltaic system and from the electricity grid. These allow you to optimise consumption and costs on your bill Electric heating element for ACS boiler The ACS electric integration serves as an integration, anti-legionella or reserve source in the event of an anomaly Fast ACS Priority to DHW production to bring the boiler to the setpoint in the shortest possible time Anti-legionella function Allows you to set weekly anti-legionella cycles Silent mode Reduces the compressor frequency and fan speed, thus significantly reducing noise. Programmable on time slots ON/OFF From external contact. Activation and deactivation via an external contact, for example from a zone thermostat Hot / cold From external contacts. Summer/winter switching signal from outside, e.g. from the zone thermostat ECO function Dedicated setpoint for “ Eco ” operation. Can be set with daily time slot Antifreeze protection Heat pump operation in heating mode with circulator ON and possible electric booster Product Warranty: All products for sale on our site are new and packaged. The warranty on this item is 24 months from the date of purchase.

    €5.540,00

  • immagine-1-ferroli-pompa-di-calore-reversibile-aria-acqua-inverter-ferroli-omnia-s-3.2-12-trifase-r-32-con-comando-incluso

    Ferroli Air-Water Reversible Heat Pump Inverter Ferroli Omnia S 3.2 12 Three-Phase R-32 With Control Included

    ATTENTION! IN CASE OF UNAVAILABILITY IMMEDIATELY, THE PRODUCT WILL BE ORDERED AND SHIPPED WITHIN 10 WORKING DAYS   FIRST START-UP FREE Technical Features Model : OMNIA S 3.2 12-T Product Code : 0XHLCSWA Command included Optional accessories Unpainted built-in cabinet 016092X0 Painted built-in wardrobe 016093X0 Optional accessories Unpainted built-in cabinet 016092X0 Painted built-in wardrobe 016093X0 Energy Efficiency Energy class in heating at 35° C: A+++ Energy class in heating at 55° C: A++ SCOP heating with water set to 35 °C: 4.81 SEER cooling with water set at 7 °C: 4.86 Performance   Heating Useful power in heating with water set at 35° C: 12.1 kW Useful power in heating with water set at 45° C: 12.3 kW Useful power in heating with water set at 55° C: 11.9 kW Power absorbed with water set at 35°C: 2.44 kW Power absorbed with water set at 45°C: 3.32 kW Power absorbed with water set at 55°C: 3.90 kW Water flow rate with water set at 35°C: 2081 l/h Water flow rate with water set at 45°C: 2116 /h Water flow rate with water set at 55°C: 1279 l/h Cooling Useful power in cooling with water set at 7 °C: 11.5 kW Useful power in cooling with water set at 18 °C: 12.0 kW Power absorbed with water set at 7° C: 4.18 kW Power absorbed with water set at 18°C: 3.04 kW Water flow rate with water set at 7°C: 1978 l/h Water flow rate with water set at 18°C: 2064 l/h Technical data of external unit Compressor type : Twin Rotary DC Number of compressors : 1 Number of refrigeration circuits: 1 Fan type : DC Axial Number of fans: 1 Sound power level in heating : 56 ~ 65 dB(A) Sound power level in cooling : 56 ~ 69 dB(A) Liquid pipe diameter: 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Maximum pipe length: 30 m Maximum pipe height difference: 20 m Technical data of the internal unit Exchanger type: Brazed stainless steel plates Expansion vessel volume: 10 litres Water safety valve calibration: 3 bar Minimum system water content: 40 litres System pipe diameter: 1" gas F Diameter of ACS pipes: 3/4" gas F Liquid pipe diameter: 9.52 mm (3/8") Gas pipe diameter: 15.88 (5/8") Electrical Data Power supply (V,Hz,Ø) : 380~415/50/3 Refrigerant gas: R32 Dimensions and Weight External unit dimensions (WxHxD): 1118x865x523 mm External unit weight: 112.0 Kg Internal unit dimensions (WxHxD): 422x702x320 mm 5 years without worries Ferroli OMNIA S 3.2 Reversible heat pumps for split installation with DC inverter compressor Silence, efficiency and design OMNIA S 3.2 is the new range of split heat pumps Full Inverter R32 by Ferroli. The range includes an External Unit with the heart of the refrigeration circuit, from the compressor to the fan with the air-side exchanger, which is connected to the refrigerant gas pipes towards the Internal Unit. The Internal Unit instead contains the heart of the generator's hydraulic circuit with all the main pre-installed components, such as the high-efficiency circulator and the expansion vessel, to allow safe, practical and fast installation The split installation of OMNIA S 3.2 , with only gas pipes between the external and internal unit, is synonymous with safety with respect to any freezing problem, even at the most rigid temperatures (up to -25°C) and in the absence of electricity. All the units satisfy the most extreme winter and summer air conditioning needs, in fact they can produce hot water up to 65°C , which makes them suitable for practically all heating systems, whether radiant, fan coil or radiator, including the production of domestic hot water (DHW), via an external boiler The new concept Ferroli Full Inverter uses DC inverter modulations on the 3 main energy-consuming components of the machine, namely compressor, fan and pump. This allows the power supplied to be modulated by finely tracking the thermal load and allowing the user extremely high efficiencies and significant energy savings . Furthermore, the concept Ferroli Full Inverter guarantees noise levels among the lowest on the market, avoiding power surges and guaranteeing a longer useful life for the components. Internal and external unit of OMNIA 3.2 The External Unit contains the heart of the refrigeration circuit, while the Internal Unit the heart of the hydraulic circuit. They are connected to each other by pipes ecological refrigerant gas R32 , which has allowed us to combine high efficiency with a reduced environmental impact. Thanks to its GWP of 675 , about a third of the GWP of R410a, helps reduce CO2 equivalent emissions, the main cause of global warming The heat pumps they use the External Unit to extract heat from the air outside the home and convey it to the water in your system, via an exchanger in the Internal Unit. This is precisely why they are able to obtain such high efficiencies , exploiting in a way renewable the energy already present in the air outside the home The new concept Ferroli Full Inverter then does the rest, tracking the thermal loads precisely and without waste (modulating the compressor, pump and fan), managing to achieve even greater efficiencies, guaranteeing significant savings on your bill , without stressing your components and with very low noise levels OMNIA S 3.2 it can be used either as the only generator in the system or integrated with other sources such as a Ferroli boiler The control system The User Interface has been equipped with Capsense technology with 2.8” graphic display, which allows the user to interact with the product in an easy and extremely simple way Modbus protocol It can be interfaced with BMS/BACS automation and management systems Heating and cooling Full Inverter modulation finely follows the desired setpoints, with the possibility of setting climatic curves in heating and cooling, further optimising the user's consumption Domestic hot water production When the DHW Temperature probe calls the machine it automatically diverts to the domestic hot water boiler with a dedicated DHW Setpoint. 3-way diverter valve supplied as standard Smart Grid Inputs from photovoltaic and grid Digital Smart Grid inputs for managing an input from a photovoltaic system and from the electricity grid. These allow you to optimise consumption and costs on your bill Electric heating element for ACS boiler The ACS electric integration serves as an integration, anti-legionella or reserve source in the event of an anomaly Fast ACS Priority to DHW production to bring the boiler to the setpoint in the shortest possible time Anti-legionella function Allows you to set weekly anti-legionella cycles Silent mode Reduces the compressor frequency and fan speed, thus significantly reducing noise. Programmable on time slots ON/OFF From external contact. Activation and deactivation via an external contact, for example from a zone thermostat Hot / cold From external contacts. Summer/winter switching signal from outside, e.g. from the zone thermostat ECO function Dedicated setpoint for “ Eco ” operation. Can be set with daily time slot Antifreeze protection Heat pump operation in heating mode with circulator ON and possible electric booster Product Warranty: All products for sale on our site are new and packaged. The warranty on this item is 24 months from the date of purchase.

    €5.345,00

Recently viewed products

Login

Forgot your password?

Don't have an account yet?
Create account