Discover our exclusive selection of Biasi, perfect for enriching your home or workspace with style, comfort and functionality. Each piece is chosen to guarantee the best quality and satisfy your every need.
Biasi
Biasi Biasi Renew Adaptive 25s Low Nox Condensing Boiler Complete With Methane Or LPG / LPG Fume Exhaust Kit
Biasi rinNova adaptive 25s low NOx condensing boiler complete with methane or LPG fume exhaust kit Heating/DHW nominal heat input kW 21.0 / 26.0 Heating/DHW minimum heat input kW 3.0 / 3.0 Heating/DHW maximum useful power 60°/80°C * kW 20.7 / 25.6 Heating/DHW minimum useful power 60°/80°C * kW 2.8 / 2.8 Heating/DHW maximum useful power 30°/50°C ** kW 22.8 / 28.2 Heating/DHW minimum useful power 30°/50°C ** kW 3.2 / 3.2 Yield name 60°/80°C * % 98.4 Yield min. 60°/80°C * % 94.0 Yield name 30°/50°C ** % 108.6 Yield min. 30°/50°C ** % 105.2 NOx class 6 Minimum/maximum heating pressure bar 0.3 / 3 Expansion tank capacity (total/useful) l 7 Maximum flow rate (ΔT=25 K) / (ΔT=35 K) l/min 15.4 / 10.7 Specific sanitary flow rate (ΔT=30 K) ***** l/min 12.8 Voltage/Power at nominal heat input V~/ W 230 / 100 Power at minimum thermal capacity W 52 Degree of protection IPX5D Height x Width x Depth mm 700 x 400 x 300 Weight kg 31.5 Boiler water content 2.0 l Code 20312.0221.0 RinNova adaptive The RinNova Adaptive condensing boiler , unlike traditional boilers, allows you to recover energy by condensing the water vapor contained in the exhaust fumes; that is, for the same amount of heat produced, it consumes less gas and furthermore the exhaust fumes contain fewer substances which are harmful to the environment. The materials that compose it and the regulation systems with which it is equipped offer safety, high comfort and energy savings, so as to be able to fully appreciate the advantages of autonomous heating. RinNova Adaptive is the new BIASI model of wall-mounted condensing boiler . It offers excellent performance and high yields that last over time, thanks to the innovative heat exchanger . Simple to use thanks to the digital control panel, with a display designed to communicate with the user easily and comfortably. Technical features Boiler with single circuit primary exchanger in stainless steel, without joints and/or welds, which maintains high efficiency even on older systems New combustion system with patented gas-adaptive technology (Advanced Adaptive Gas Combustion Control – A²GC²) The electronics continuously analyze the combustion (CO2) through the flame signal and intervene by acting on the gas valve and fan, to allow correct combustion in all terms of use. The electronics allow the boiler to be easily adapted to the various types of gas without having to intervene with a mechanical transformation kit Instant production of domestic hot water with dedicated plate exchanger Domestic hot water pre-heating function: faster delivery of domestic hot water User interface with display and multifunction keys for adjusting and setting the parameters Easy to inspect standard by-pass Chimney Protection System: electronic management of fume overheating, guaranteeing maximum protection of the chimney Ducting on flues: particularly suitable for operation in flues that require ducting with high pressure drops Minimum polluting emissions (class VI - EN 15502-1) Sliding temperature operation via optional external probe Low consumption modulating heating pump (ErP Ready - Class A) Digital flame control with three re-ignition attempts in the event of blocking due to lack of flame detection (methane configuration) Removable casing in three pieces for easier maintenance or inspection For SV versions: possibility of setting the maximum power that can be supplied to the external boiler Gas-adaptive technology Less consumption, more efficiency, fewer emissions The innovative Adaptive Gas technology, which all models in the Rinnova line are equipped with, allows the boilers to be adapted in complete autonomy to the different types and qualities of gas. The electrode, in addition to detecting the flame, also detects the characteristics of the gas and automatically adapts the combustion parameters to maintain the maximum level of efficiency, with a consequent reduction in consumption and emissions compared to traditional control systems. The Adaptive gas system makes the boiler ready to operate with any type of gas without transformations. Automatic gas regulation Adaptation to changing gas quality Clean combustion The only model suitable for methane and LPG which allows you to optimize the warehouse In traditional boilers, the combustion values are detected and adjusted only during maintenance, furthermore the composition of the gas network is not always constant and can create operating inefficiencies on boilers without combustion control devices, compromising reliability, savings and the quality of emissions. Thanks to the Gas-Adaptive system, the new condensing boilers electronically control combustion by managing the gas and air supply at best and at all times, automatically adapting the CO2. A "Plastic-FREE" production For a more sustainable environment A fundamental element that guided the entire design phase of the new Rinnova Adaptive boiler is the strong focus on the circular economy. For this we have used components with a higher rate of recyclability, eliminating the use of plastic as much as possible. The plastic group, for example, has been replaced with the brass group, a completely recyclable material. The protective shells of the boiler were made of cardboard and no longer of polystyrene. Furthermore, the front is no longer in plastic but in pressed steel. Thermoregulation Climatic regulation (with optional external probe) and ambient regulation (remote) to allow correct management of the water temperature in order to reduce consumption and consequently a reduction in emissions. By using the climatic regulation, the regulation efficiency also rises, giving greater value to the home. High circulation single coil primary heat exchanger Biasi, introduces the Round heat exchanger in 2017. The great reliability has been demonstrated by adopting it in the Renew Adaptive range. Round is a compact monothermal heat exchanger based on a stainless steel coil with an oval section. The heat exchanger consists of a combustion chamber, condensing area and an insulated metal disc protected with silicone ceramic fiber which separates the two areas. By using a single stainless steel strip to produce the coil, including inlet/outlet fittings, the following benefits are achieved: Accumulation of dirt and debris is avoided The water flow is uniformly distributed and guarantees a homogeneous heat exchange The water flow is constant for a longer life of the product Reduction of pressure drops with optimized circuit The ease of cleaning and the robustness of this exchanger are one of the main strengths of the product since it can be used on new systems but also on old systems in the event of renovations. Round integrates the round flow function in which the water produces a centrifugal cleaning effect on the internal walls of the single coil. The absence of circuits in parallel guarantees an easy "washing" operation of the exchanger and the elimination of any air present in the system circuit. Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.417,00
Biasi Caldaia Biasi rinNova adaptive 35s a condensazione low NOx completa di kit scarico fumi Metano o Gpl
Caldaia Biasi rinNova adaptive 35s a condensazione low NOx completa di kit scarico fumi Metano o Gpl Portata termica nominale riscaldamento/sanitario kW 31,0 / 34,7 Portata termica minima riscaldamento/sanitario kW 3,8 / 3,8 Potenza utile massima riscaldamento/sanitario 60°/80°C * kW 30,6 / 34,1 Potenza utile minima riscaldamento/sanitario 60°/80°C * kW 3,6 / 3,6 Potenza utile massima riscaldamento/sanitario 30°/50°C ** kW 28,3 / 33,7 Potenza utile minima riscaldamento/sanitario 30°/50°C ** kW 4,0 / 4,0 Rendim. nom. 60°/80°C * % 98,8 Rendim. min. 60°/80°C * % 94,5 Classe NOx 6 Temperatura minima/massima riscaldamento **** °C 25 / 80 Pressione minima/massima riscaldamento bar 0,3 / 3 Capacità del vaso espansione (totale/utile) l 7 Temperatura minima/massima sanitario °C 35 / 55 Pressione minima/massima sanitario bar 0,3 / 10 Portata massima (ΔT=25 K) / (ΔT=35 K) l/min 20,5 / 14,3 Tensione/Potenza alla portata termica nominale V~/ W 230 / 116 Potenza alla portata termica minima W 55 Grado di protezione IPX5D Temperatura dei fumi minima/massima # °C 41 / 80 Altezza x Larghezza x Profondità mm 700 x 400 x 300 Peso kg 36 Contenuto d’acqua della caldaia l2,5 Codice 10314.2076.0 RinNova adaptive La caldaia a condensazione RinNova Adaptive, a differenza delle caldaie tradizionali, consente di recuperare energia condensando il vapore acqueo contenuto nei fumi di scarico; cioè, a parità di calore prodotto, consuma meno gas ed inoltre i fumi di scarico contengono meno sostanze dannose per l’ambiente. I materiali che la compongono e i sistemi di regolazione di cui è dotata offrono sicurezza, comfort elevato e risparmio energetico, così da poter apprezzare al massimo i vantaggi del riscaldamento autonomo.RinNova Adaptive è il nuovo modello BIASI di caldaia murale a condensazione.Offre ottime prestazioni e alti rendimenti che durano nel tempo, grazie all’innovativo scambiatore di calore. Semplice da utilizzare grazie al pannello di controllo digitale, con display progettato per comunicare con l’utente in maniera facile e comoda. Caratteristiche tecniche Caldaia con scambiatore primario in acciaio inox mono circuito, privo di giunzioni e/o saldature, che mantiene un’alta efficienza anche su impianti non recenti Nuovo sistema di combustione con tecnologia brevettata gas-adaptive (Advanced Adaptive Gas Combustion Control – A²GC²) L’elettronica analizza continuamente la combustione (CO2) attraverso il segnale di fiamma e interviene agendo sulla valvola gas e sul ventilatore, per permettere una corretta combustione in tutte le condizioni d’utilizzo. L’elettronica permette di adattare facilmente la caldaia ai vari tipi di gas senza dover intervenire con kit di trasformazione meccanica Produzione istantanea di acqua calda sanitaria con scambiatore a piastre dedicato Funzione Prerirscaldo Sanitario: maggior rapidità nell’erogazione di acqua calda sanitaria Interfaccia utente con display e tasti multifunzione per la regolazione e l’impostazione dei parametri By-pass di serie facilmente ispezionabile Sistema Protezione camino: gestione elettronica delle sovratemperature fumi, garantendo la massima protezione del camino Intubamento su canne fumarie: particolarmente adatta al funzionamento in canne fumarie che necessitano di intubamenti che presentano alte perdite di carico Minime emissioni inquinanti (classe VI - EN 15502-1) Funzionamento a temperatura scorrevole tramite sonda esterna opzionale Circolatore riscaldamento modulante a basso consumo (ErP Ready - Classe A) Controllo fiamma digitale a tre tentativi di riaccensione in caso di blocco funzionamento per mancanza di rilevazione fiamma (configurazione a metano) Mantellatura smontabile in tre pezzi per una più semplice manutenzione o ispezione Per versioni SV: possibilità di impostare la potenza massima erogabile al bollitore esterno Tecnologia Gas AdaptiveMeno consumi, più efficienza, meno emissioniL’innovativa tecnologia Adaptive Gas, di cui sono dotati tutti i modelli della linea Rinnova, consente l’adattamento in completa autonomia delle caldaie alle diverse tipologie e qualità di gas. L’elettrodo, oltre a rilevare la fiamma, rileva anche le caratteristiche del gas e adatta automaticamente i parametri di combustione per mantenere il massimo livello di efficenza, con conseguente riduzione dei consumi e delle emissioni rispetto ai sistemi di controllo tradizionale. ll sistema Adaptive gas rende la caldaia predisposta a funzionare con qualsiasi tipo di gas senza trasformazioni. Regolazione automatica del gas Adattamento al cambio della qualità del gas Combustione pulita Unico modello adatto a metano e GPL che consente di ottimizzare il magazzinio Nelle caldaie tradizionali i valori della combustione vengono rilevati e regolati solo in fase di manutenzione, inoltre la composizione dei gas di rete non è sempre costante e può creare sulle caldaie prive di dispositivi di controllo della combustione inefficenze del funzionamento compromettendo l’affidabilità, i risparmi e la qualità delle emissioni. Grazie al sistema Gas-Adaptive, le nuove caldaie a condensazione controllano elettronicamente la combustione gestendo al meglio ed in ogni momento l’apporto di gas e aria, adattando automaticamente la CO2. Una produzione "Plastic-FREE"Per un ambiente più sostenibileUn elemento fondamentale che ha guidato tutta la fase di progettazione della nuova caldaia Rinnova Adaptive è la forte attenzione nei confronti dell’economia circolare. Per questo abbiamo impiegato componenti con un maggiore tasso di riciclabilità, eliminando il più possibile l’utilizzo della plastica. Il gruppo in plastica, ad esempio, è stato sostituito con il gruppo in ottone, materiale completamente riciclabile. I gusci di protezione della caldaia sono stati realizzati in cartone e non più in polistirolo. Il frontale, inoltre, non è più in plastica ma in acciaio stampato. TermoregolazioneRegolazione climatica (con sonda esterna opzionale) e regolazione ambiente (remoto) per permettere una corretta gestione della temperatura dell’acqua allo scopo di ridurre i consumi e conseguentemente una riduzione delle emissioni.Utilizzando la regolazione climatica anche il rendimento di regolazione si innalza, conferendo maggior valore all’abitazione. Scambiatore primario monospira ad alta circolazioneBiasi, introduce nel 2017 lo scambiatore Round. Dimostrata la grandissima affidabilità lo addotta nella gamma Rinnova Adaptive. Round è uno scambiatore di calore monotermico compatto basato su una serpentina di acciaio inox con una sezione ovale. Lo scambiatore di calore è costituito da una camera di combustione, zona di condensazione e un disco metallico coibentato protetto con fibra ceramica siliconica che separa le due aree.Utilizzando un singolo nastro di acciaio inossidabile per produrre la serpentina, compresi attacchi ingresso/uscita, si ottengono i seguenti vantaggi: Si evita l’accumulo di sporco e detriti La portata acqua è distribuita uniformemente e garantisce uno scambio termico omogeneo La portata acqua è costante per una più lunga vita del prodotto Riduzione delle perdite di carico con circuito ottimizzato La facilita di pulizia e la robustezza di tale scambiatore sono uno dei principali punti di forza del prodotto dato che può essere utilizzato su impianti nuovi ma anche su impianti vecchi in caso di ristrutturazioni. Round integra la funzione round flow nella quale l’acqua produce un effetto centrifugo di pulizia delle pareti interne della mono spira. L’assenza di circuiti in parallelo garantisce una agevole operazione di “lavaggio” dello scambiatore e l’eliminazione di eventuale aria presente nel circuito dell’impianto. Garanzia Tutti i prodotti in vendita sul nostro sito sono nuovi ed imballati. La garanzia su questo articolo è 24 mesi dalla data dell'acquisto.
€1.396,00
Biasi Biasi Gas Boiler Renew Cond XE 35s Condensing Complete With Methane Fume Exhaust Kit -New Erp
Overview BIASI rinNOVA COND XE 35S CONDENSING BOILER COMPLETE WITH LPG METHANE FUME EXHAUST KIT - NEW ErP Technical specifications Model: rinNOVA COND XE 35S Energy label specifications according to the European ErPÿ directive Class A heating energy efficiency Sanitary energy efficiency Class A Withdrawal profiles: XXL Characteristics of heating/sanitary exercises: Thermal powerÿuseful sanitaryÿ(80/60ø C)ÿkW (kcal/h)ÿ33.4 (28,724) Heating capacityÿuseful heatingÿ(80/60ø C)ÿkW (kcal/h)ÿ32.1 (27,606) Heat input(*)ÿnominalÿkW (kcal/h)ÿ34.0 (29,240) Heat inputÿminimumÿkW (kcal/h)ÿ8.5 (7,309) Sanitary flowÿt =25øKÿl/minÿ21.6 Dimensions (HxWxD) 700x400x290 mm Main features renew COND Xÿ RinNova Cond X The BIASI premixed condensing range completes: perfectÿfor underfloor systems for radiator systems, the compact condensing boiler that ensures high yields, low consumption and respect for the environment. Availableÿfor heating and domestic hot water production, in powers of 25 and 35 kW and forÿheating only in powers of 16, 25 and 35 kW. Characteristics: High yields (in compliance with yield directive 92/42 EEC and Legislative Decree 311/06) Sanitary comfortÿÿ(EN 13203) Primary and condensing exchanger in stainless steel with plastic linings to offer maximum resistance to corrosion Total premix burner, built in stainless steel (class NOx 5) Sanitary plate heat exchanger in stainless steel High efficiency pump with low energy consumption Maximum power adjustable according to the needs of the system Degrees of protection IPX5D Installability in a partially protected place Integration with BIASI solar systems using a solar kit digital control panel with backlit display Digital pressure reading by pressure transducer Arrangement for external probe remote control Four-controllers Summer/winter/off selector Heating temperature regulator DHW temperature regulator Digital pressure reading DHW and heating temperature visualization from display Display of fault diagnostics, fault history block status View recommended fill View annual maintenance expiry The display operates according to the modes: 1. INFO. Inf mode displays the following information: External temperature (in case of connected external probe) K value (in case of connected external probe) Sanitary / heating temperatures chosen by the user Smoke temperatures. 2. PROGRAMMING. The programming mode allows you to modify the boiler parameters. In chimney sweep mode it is possible to test the boiler and make adjustments to the gas valve. RinNova Cond XE: Adjustable maximum power The adjustable maximum useful heating power parameter meets the needs of modern construction without compromising comfort required in the production of domestic hot water. In fact, this function makes it possible to limit the maximum useful power in heating, independently of the useful domestic power. Hot water even with the sun RinNova Cond XE for heating and hot water production: the sanitary exchangerÿin stainless steel combined with the electronic management and low inertia of the primary exchangerÿdetermine excellent performance even in the production of domestic hot water.ÿFor the production of domestic hot water RinNova Cond XE can be combined with BIASI solar systems using specific solar kit (optional). The boiler cuts in only when necessary, making the most of solar energy and guaranteeing the comfort required by the user. Included in delivery: Boiler support bracket and paper template Boiler power cable Condensate collection siphon Quick instruction to the user. All ready for Energy Labeling What is it about From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy intensive sectors: construction For placing on the European market, the directive on ÿeco-designÿ(ErP notcome®ÿEnergy Related Productsÿ¯) imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres or As in the household appliances sector, the energy labelingÿof products, with a capacity of less than 70 kW, will give consumers simple, recognizable information which allows them to make comparisonsÿon the performance and energy consumption of the product they wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. It's about me tooÿ YES, it affects everyone: professionals and end users The information indicated on the energy labelÿwill allow professionals to recommend the right productÿÿindividuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015, the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. Supplier's responsibility The company that supplies the product on the market is required to equip its system devices with the following documentation: product energy label;ÿ product data sheet;ÿ system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices;ÿ technical data sheet of the system with the parts relating to the products and the system already completed. Responsibilities of Resellersÿ First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device/system to the public. Therefore, even professionals such as plumbers, installers, designers can fall into this category. All bound to ensure that: all appliances and/systems having their respective labels and making sure they are clearly visible;ÿ all appliances and/systems must always be accompanied by the obligatory technical data sheets;ÿ every type of advertising material, technical promotional material which shows energy data and price indications, contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and the production of hot water will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP): The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL There are different labels depending on the type of appliance. Those with efficiency classes A, A+ and A++ certify products with the highest performance. Furthermore, two different classifications are foreseen for domestic heating and for hot water production services, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the end customer can make his choice in the most aware way possible. SYSTEM LABEL In addition to the product label, the system label is also providedÿin cases where a series of appliances combined with each other is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label so as to inform the end user in the best possible way. Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€997,00
Biasi Biasi Gas Boiler Renew Cond Plus 35 S Methane Complete With Fume Exhaust Kit
Technical features Model: rinNOVA COND PLUS E 35S Energy label specifications according to the European ErP directive Class A heating energy efficiency Sanitary energy efficiency Class A Withdrawal profile: XL Characteristics of heating/DHW operation: Heating / DHW nominal heat input kW 29.0 / 33.5 Heating / DHW maximum useful output 60°/80°C * 28.2 / 32.5 Energy yield n° **** NOx class 6 Expansion vessel capacity 7.0 l (total) Maximum range (ΔT=25K) / (ΔT=35K) 18.6 / 13.3 Degree of protection IPX5D Dimensions HxWxD 700x400x290; 34.5Kg General characteristics renew COND PLUS RinNova Cond Plus is the new BIASI range of wall-mounted condensing boilers: excellent performance thanks to the new heat exchanger and ease of use thanks to the digital control panel with display. Available in versions for heating and domestic hot water production and for heating only RinNova Cond Plus presents a complete range of powers, 20 and 30 kW combi models and 16 KW SV models, in the same extremely compact dimensions (700 x 400 x 290 mm) . RinNova Cond Plus has its strong point in the innovative heat exchanger designed to provide high yields that last over time digital control panel, designed to communicate with the user in an easy and comfortable way. Like the entire BIASI condensing range, RinNova Cond Plus allows you to obtain maximum savings from climatic thermoregulation, based on the system in which the boiler is installed Characteristics: High yields (★★★★ compliant with yield directive 92/42 EEC and Legislative Decree 311/06) Sanitary comfort (★★★ EN 13203) Primary condensing exchanger in stainless steel with steel lining to offer maximum resistance to corrosion Total premix burner, built in stainless steel (Class NOx 6) Modulation 1:5 CNG and also LPG Sanitary plate heat exchanger in stainless steel 7 liter expansion tank High efficiency pump with low energy consumption Maximum power adjustable according to the system • IPX5D degree of protection Can be installed in a partially protected place Integration with BIASI solar systems, using a solar kit Digital control panel with backlit display Analog pressure reading Arrangement for remote control and external probe. Control panel Summer/winter/off selector Heating temperature regulator DHW temperature regulator Analog pressure reading DHW and heating temperature visualization from the display Display of fault diagnostics, block status and fault history Recommended fill display and fill guide View annual maintenance expiry The display operates according to the modes: 1. INFO. Info mode displays the following information: External temperature (in case of external probe connected) K value (in case of external probe connected) Sanitary / heating temperatures chosen by the user Smoke temperatures. 2. PROGRAMMING. The programming mode allows you to change the boiler parameters. - In chimney sweep mode it is possible to test the boiler and adjust the gas valve. Thermoregulation By connecting the external probe and the remote control (optional) directly to the boiler, climatic regulation can be used. RinNova Cond Plus will adapt the system water temperature to the external climatic conditions, ensuring that the desired room temperature is reached without waste and optimizing consumption. By using the climatic regulation, the regulation efficiency is also raised, giving greater value to your home. High regulation single coil primary heat exchanger Biasi introduces on the market the new stainless steel heat exchanger for condensing boilers: Round. Round is a compact monothermal heat exchanger based on a stainless steel coil with an oval section. The heat exchanger consists of a combustion chamber, condensing area and an insulated metal disc protected with silicone ceramic fiber which separates the two areas. By using a single strip of stainless steel to produce the coil, including inlet/outlet fittings, the following benefits are achieved: Accumulation of dirt and debris is avoided The water flow is uniformly distributed and guarantees a homogeneous heat exchange The water flow is constant for a longer life of the product Reduction of pressure drops with optimized circuit. The ease of cleaning and the robustness of this exchanger are one of the main strengths of the product since it can be used on new systems but also on old systems in the event of renovations. Round integrates the round flow function in which the water produces a centrifugal cleaning effect on the internal walls of the single coil. The absence of circuits in parallel guarantees an easy "washing" operation of the exchanger and the elimination of any air present in the system circuit. All ready for Energy Labeling What is it about? From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy-intensive sectors: construction For placing on the European market, the eco-design directive ( ErP known as « Energy Related Products ») imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres As in the household appliances sector, the energy labeling of products with a capacity of less than 70 kW will give consumers simple, recognizable information which allows for comparisons on the performance and energy consumption of the product you wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. Is it about me too? YES, it affects everyone: professionals and end users The information indicated on the energy label will allow professionals to recommend the right product and individuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015 , the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. Supplier responsibility The company that supplies the product on the market is required to equip its devices or systems with the following documentation: product energy label; technical product sheet; system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices; technical data sheet of the system with the parts relating to the product or system already completed. Dealer Responsibility First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device and/or system to the public. Therefore even professionals such as plumbers, installers or planners can fall into this category. Everyone is required to ensure that: all appliances and/or systems have their respective labels and make sure that they are clearly visible; all devices and/or systems are always accompanied by the mandatory technical data sheets; any type of advertising, promotional or technical material showing energy data or price indications contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and hot water production will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP) : The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL Depending on the type of device, there are different labels. Those with efficiency classes A, A+ and A++ certify the products with the highest performance. Furthermore, two different classifications are envisaged for domestic heating and for the hot water production service, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the final customer can make his choice in the most informed way possible. SYSTEM LABEL In addition to the product label, the system label is also provided if a series of matched appliances is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label in order to inform the end user in the best possible way. Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.024,00
Biasi Biasi Renew Adaptive 30s Low Nox Condensing Boiler Complete With Methane Or LPG / LPG Fume Exhaust Kit
Biasi rinNova adaptive 30s low NOx condensing boiler complete with methane or LPG fume exhaust kit Heating/DHW nominal heat input kW 26.0 / 31.0 Heating/DHW minimum heat input kW 3.8 / 3.8 Heating/DHW maximum useful power 60°/80°C *kW 25.6 / 30.6 Heating/DHW minimum useful power 60°/80°C * kW 3.6 / 3.6 Heating/DHW maximum useful power 30°/50°C ** kW 28.3 / 33.7 Heating/DHW minimum useful power 30°/50°C ** kW 4.0 / 4.0 Yield at 30% load ** % 109.7 NOx class 6 Minimum/maximum heating pressure bar 0.3 / 3 Expansion tank capacity (total/useful) l 7 Maximum flow rate (ΔT=25 K) / (ΔT=35 K) l/min 18.3 / 12.8 Voltage/Power at nominal heat input V~/ W 230 / 96 Power at minimum thermal capacity W 55 Degree of protection IPX5D Height x Width x Depth mm 700 x 400 x 300 Weight kg 36 Boiler water content 2.5 l RinNova adaptive The RinNova Adaptive condensing boiler , unlike traditional boilers, allows you to recover energy by condensing the water vapor contained in the exhaust fumes; that is, for the same amount of heat produced, it consumes less gas and furthermore the exhaust fumes contain fewer substances which are harmful to the environment. The materials that compose it and the regulation systems with which it is equipped offer safety, high comfort and energy savings, so as to be able to fully appreciate the advantages of independent heating. RinNova Adaptive is the new BIASI model of wall-mounted condensing boiler . It offers excellent performance and high yields that last over time, thanks to the innovative heat exchanger . Simple to use thanks to the digital control panel, with a display designed to communicate with the user easily and comfortably. Technical features Boiler with single circuit primary exchanger in stainless steel, without joints and/or welds, which maintains high efficiency even on older systems New combustion system with patented gas-adaptive technology (Advanced Adaptive Gas Combustion Control – A²GC²) The electronics continuously analyze the combustion (CO2) through the flame signal and intervene by acting on the gas valve and fan, to allow correct combustion in all terms of use. The electronics allow the boiler to be easily adapted to the various types of gas without having to intervene with a mechanical transformation kit Instant production of domestic hot water with dedicated plate exchanger Domestic hot water pre-heating function: faster delivery of domestic hot water User interface with display and multifunction keys for adjusting and setting the parameters Easy to inspect standard by-pass Chimney Protection System: electronic management of fume overheating, guaranteeing maximum protection of the chimney Ducting on flues: particularly suitable for operation in flues that require ducting with high pressure drops Minimum polluting emissions (class VI - EN 15502-1) Sliding temperature operation via optional external probe Low consumption modulating heating pump (ErP Ready - Class A) Digital flame control with three re-ignition attempts in the event of blocking due to lack of flame detection (methane configuration) Removable casing in three pieces for easier maintenance or inspection For SV versions: possibility of setting the maximum power that can be supplied to the external boiler Gas-adaptive technology Less consumption, more efficiency, fewer emissions The innovative Adaptive Gas technology, which all models in the Rinnova line are equipped with, allows the boilers to be adapted in complete autonomy to the different types and qualities of gas. The electrode, in addition to detecting the flame, also detects the characteristics of the gas and automatically adapts the combustion parameters to maintain the maximum level of efficiency, with a consequent reduction in consumption and emissions compared to traditional control systems. The Adaptive gas system makes the boiler ready to operate with any type of gas without transformations. Automatic gas regulation Adaptation to changing gas quality Clean combustion The only model suitable for methane and LPG which allows you to optimize the warehouse In traditional boilers, the combustion values are detected and adjusted only during maintenance, furthermore the composition of the gas network is not always constant and can create operating inefficiencies on boilers without combustion control devices, compromising reliability, savings and the quality of emissions. Thanks to the Gas-Adaptive system, the new condensing boilers electronically control combustion by managing the gas and air supply at best and at all times, automatically adapting the CO2. A "Plastic-FREE" production For a more sustainable environment A fundamental element that guided the entire design phase of the new Rinnova Adaptive boiler is the strong focus on the circular economy. For this we have used components with a higher rate of recyclability, eliminating the use of plastic as much as possible. The plastic group, for example, has been replaced with the brass group, a completely recyclable material. The protective shells of the boiler were made of cardboard and no longer of polystyrene. Furthermore, the front is no longer in plastic but in pressed steel. Thermoregulation Climatic regulation (with optional external probe) and ambient regulation (remote) to allow correct management of the water temperature in order to reduce consumption and consequently a reduction in emissions. By using the climatic regulation, the regulation efficiency also rises, giving greater value to the home. High circulation single coil primary heat exchanger Biasi, introduces the Round heat exchanger in 2017. The great reliability has been demonstrated by adopting it in the Renew Adaptive range. Round is a compact monothermal heat exchanger based on a stainless steel coil with an oval section. The heat exchanger consists of a combustion chamber, condensing area and an insulated metal disc protected with silicone ceramic fiber which separates the two areas. By using a single stainless steel strip to produce the coil, including inlet/outlet fittings, the following benefits are achieved: Accumulation of dirt and debris is avoided The water flow is uniformly distributed and guarantees a homogeneous heat exchange The water flow is constant for a longer life of the product Reduction of pressure drops with optimized circuit The ease of cleaning and the robustness of this exchanger are one of the main strengths of the product since it can be used on new systems but also on old systems in the event of renovations. Round integrates the round flow function in which the water produces a centrifugal cleaning effect on the internal walls of the single coil. The absence of circuits in parallel guarantees an easy "washing" operation of the exchanger and the elimination of any air present in the system circuit. Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.284,00
Biasi Gas Boiler Biasi Inovia Cond E 35s Condensing Complete With Methane Fume Exhaust Kit - New Erp
Overview BIASI INOVIA COND E 35S METHANE CONDENSING BOILER - NEW ErP, SEALED CHAMBER COMPLETE WITH FUME EXHAUST KIT: Wall mounted condensing boilers. The premixed range is simple on the outside and technological on the inside. The sites displaying the Biasi web sales authorized brand have been authorized by BSG Caldaie a Gas SpA for the sale of Biasi products. These companies therefore release the conventional guarantee. Technical specifications o Model: Inovia Cond E 35S Energy label specifications according to the European ErP directive o Class A heating energy efficiency o Sanitary energy efficiency Class A o Withdrawal profile: XXL Characteristics of heating/DHW operation: o DHW useful thermal power: 33.4 kW o Useful thermal power for heating: 29.5 kW o Nominal kW heat input(*): 34 kW o Efficiency at 100% load: 107.1% o Sanitary flow rate t =25°K l/min: 21.6 l/min o High yields (in compliance with yield directive 92/42 CEE and Legislative Decree 311/06) o Sanitary comfort (EN 13203) o Total premix burner, built in stainless steel (Class NOx 5) o Sanitary plate heat exchanger in stainless steel o High efficiency pump with low energy consumption o IPX5D degree of protection o Dimensions hxwxd: mm 700 x 400 x 290; 32kg o METHANE power supply Main features Inovia Cond E Premixed condensing boilers Inovia Cond E represents the new premixed BIASI condensing boiler. Inovia Cond E is equipped with innovative aesthetics and a new interface that is immediate and easy to use, it is equipped with new functions that make it an integral part of a system and which facilitate its installation and maintenance. Inovia Cond E offers all the advantages of condensing technology: great performance, high efficiency, energy saving and respect for the environment thanks to reduced polluting emissions such as NOx and CO. Installed in low temperature systems, they allow savings of up to 30%. Characteristics: o • High yields (in compliance with yield directive 92/42 EEC and Legislative Decree 311/06) or • Sanitary comfort (EN 13203) o • Primary condensing exchanger in stainless steel with plastic coating to offer maximum resistance to corrosion o • Total premix burner, built in stainless steel (Class NOx 5) or • Sanitary plate heat exchanger in stainless steel or • High efficiency pump with low energy consumption or • IPX5D degree of protection or • Can be installed in a partially protected place or • Integration with BIASI solar systems, using a solar kit o • Innovative digital control panel with graphic interface and keys or • Digital pressure reading by pressure transducer or • Arrangement for remote control and external probe or • Possibility? to manage a zone valve via remote control in the case of multi-zone systems. Control panel: o Summer/winter/off selector o Heating temperature regulator o DHW temperature regulator o Digital pressure reading o Domestic hot water and heating temperature visualization from the display o Visualization of fault diagnostics, block status and fault history o Recommended filling view and filling guide o View months left until annual maintenance is due o External temperature display (with external probe connected) and signaling of external probe connected and K value set o Display of flame modulation o Visualization of the BIASI SOLCONTROL solar control unit connected to Inovia Cond E, active solar pump and solar integration o DHW comfort function selectable by means of a dedicated and programmable key o Direct access to the INFO menu dedicated to the user. Fiscal detraction As a condensing boiler, Inovia Cond E allows you to take advantage of the tax deduction according to current legislation. d Thermoregulation By connecting the external probe (optional) directly to the boiler, climatic regulation can be used. Inovia Cond E will adapt the system water temperature to the external climatic conditions, ensuring that the desired room temperature is reached without waste and optimizing consumption. The boiler is equipped with a complete set of curves which can be accessed by entering programming. The curve is simply chosen from the control panel. Solar management Inovia Cond E integrates solar management directly within the product. Thanks to the integrated solar management it is possible to connect the SOLCONTROL control unit and view the status of the pump and the relative solar integration. Zone management Inovia Cond E features the zone management card as standard which allows you to manage a zone valve using the BIASI remote control. In the case of a system with several high temperature zones, one zone can be managed by remote control and the other zones can be managed by chronothermostats. This allows you to select two thermoregulation curves, one in the boiler and the other in the remote control. All the zones controlled by chronothermostats will be managed by the thermoregulation curve set in the boiler, the zone controlled by the remote control will be managed by the thermoregulation curve set therein. In the case of multi-zone systems at high and low temperatures, it is recommended to use the BIASI MULTIzone system manager. All ready for Energy Labeling What is it about? From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy-intensive sectors: construction For placing on the European market, the Eco-Design Directive (ErP known as « Energy Related Products ») imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: or generators with a capacity of less than 400 kW or water heaters with a capacity of less than 400 kW, or kettles with a capacity of less than 2000 litres As in the household appliances sector, the energy labeling of products with a capacity of less than 70 kW will give consumers simple, recognizable information which allows them to compare the performance and energy consumption of the product they wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. Is it about me too? YES, it affects everyone: professionals and end users The information indicated on the energy label will allow professionals to recommend the right product and individuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015, the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. Supplier responsibility The company that supplies the product on the market is required to equip its devices or systems with the following documentation: o product energy label; o product data sheet; o system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices; o technical data sheet of the system with the parts relating to the product or the system already completed. Dealer Responsibility First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device and/or system to the public. Therefore even professionals such as plumbers, installers or planners can fall into this category. Everyone is required to ensure that: o all appliances and/or systems are equipped with the respective labels and make sure that they are clearly visible; o all devices and/or systems are always accompanied by the mandatory technical data sheets; o any type of advertising, promotional or technical material in which energy data or price indications are shown, contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and hot water production will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP): The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL Depending on the type of device, there are different labels. Those with efficiency classes A, A+ and A++ certify the products with the highest performance. Furthermore, two different classifications are envisaged for domestic heating and for the hot water production service, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the final customer can make his choice in the most informed way possible. SYSTEM LABEL In addition to the product label, the system label is also provided if a series of matched appliances is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label in order to inform the end user in the best possible way. Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.231,00
Biasi Gas Boiler Biasi Inovia Cond E 35s Condensing Complete With LPG Fume Exhaust Kit - New Erp
Overview BIASI INOVIA COND E 35S LPG CONDENSING BOILER - NEW ErP, SEALED CHAMBER COMPLETE WITH FUME EXHAUST KIT: Wall mounted condensing boilers. The premixed range is simple on the outside and technological on the inside. The sites displaying the Biasi web sales authorized brand have been authorized by BSG Caldaie a Gas SpA for the sale of Biasi products. These companies therefore release the conventional guarantee. Technical specifications o Model: Inovia Cond E 35S Energy label specifications according to the European ErP directive o Class A heating energy efficiency o Sanitary energy efficiency Class A o Withdrawal profile: XXL Characteristics of heating/DHW operation: o DHW useful thermal power: 33.4 kW o Useful thermal power for heating: 29.5 kW o Nominal kW heat input(*): 34 kW o Efficiency at 100% load: 107.1% o Sanitary flow rate t =25°K l/min: 21.6 l/min o High yields (in compliance with yield directive 92/42 CEE and Legislative Decree 311/06) o Sanitary comfort (EN 13203) o Total premix burner, built in stainless steel (Class NOx 5) o Sanitary plate heat exchanger in stainless steel o High efficiency pump with low energy consumption o IPX5D degree of protection o Dimensions hxwxd: mm 700 x 400 x 290; 32kg o LPG power supply Main features Inovia Cond E Premixed condensing boilers Inovia Cond E represents the new premixed BIASI condensing boiler. Inovia Cond E is equipped with innovative aesthetics and a new interface that is immediate and easy to use, it is equipped with new functions that make it an integral part of a system and which facilitate its installation and maintenance. Inovia Cond E offers all the advantages of condensing technology: great performance, high efficiency, energy saving and respect for the environment thanks to reduced polluting emissions such as NOx and CO. Installed in low temperature systems, they allow savings of up to 30%. Characteristics: o • High yields (in compliance with yield directive 92/42 EEC and Legislative Decree 311/06) or • Sanitary comfort (EN 13203) o • Primary condensing exchanger in stainless steel with plastic coating to offer maximum resistance to corrosion o • Total premix burner, built in stainless steel (Class NOx 5) or • Sanitary plate heat exchanger in stainless steel or • High efficiency pump with low energy consumption or • IPX5D degree of protection or • Can be installed in a partially protected place or • Integration with BIASI solar systems, using a solar kit o • Innovative digital control panel with graphic interface and keys or • Digital pressure reading by pressure transducer or • Arrangement for remote control and external probe or • Possibility? to manage a zone valve via remote control in the case of multi-zone systems. Control panel: o Summer/winter/off selector o Heating temperature regulator o DHW temperature regulator o Digital pressure reading o Domestic hot water and heating temperature visualization from the display o Visualization of fault diagnostics, block status and fault history o Recommended filling view and filling guide o View months left until annual maintenance is due o External temperature display (with external probe connected) and signaling of external probe connected and K value set o Display of flame modulation o Visualization of the BIASI SOLCONTROL solar control unit connected to Inovia Cond E, active solar pump and solar integration o DHW comfort function selectable by means of a dedicated and programmable key o Direct access to the INFO menu dedicated to the user. Fiscal detraction As a condensing boiler, Inovia Cond E allows you to take advantage of the tax deduction according to current legislation. d Thermoregulation By connecting the external probe (optional) directly to the boiler, climatic regulation can be used. Inovia Cond E will adapt the system water temperature to the external climatic conditions, ensuring that the desired room temperature is reached without waste and optimizing consumption. The boiler is equipped with a complete set of curves which can be accessed by entering programming. The curve is simply chosen from the control panel. Solar management Inovia Cond E integrates solar management directly within the product. Thanks to the integrated solar management it is possible to connect the SOLCONTROL control unit and view the status of the pump and the relative solar integration. Zone management Inovia Cond E features the zone management card as standard which allows you to manage a zone valve using the BIASI remote control. In the case of a system with several high temperature zones, one zone can be managed by remote control and the other zones can be managed by chronothermostats. This allows you to select two thermoregulation curves, one in the boiler and the other in the remote control. All the zones controlled by chronothermostats will be managed by the thermoregulation curve set in the boiler, the zone controlled by the remote control will be managed by the thermoregulation curve set therein. In the case of multi-zone systems at high and low temperatures, it is recommended to use the BIASI MULTIzone system manager. All ready for Energy Labeling What is it about? From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy-intensive sectors: construction For placing on the European market, the Eco-Design Directive (ErP known as « Energy Related Products ») imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: or generators with a capacity of less than 400 kW or water heaters with a capacity of less than 400 kW, or kettles with a capacity of less than 2000 litres As in the household appliances sector, the energy labeling of products with a capacity of less than 70 kW will give consumers simple, recognizable information which allows them to compare the performance and energy consumption of the product they wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. Is it about me too? YES, it affects everyone: professionals and end users The information indicated on the energy label will allow professionals to recommend the right product and individuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015, the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. Supplier responsibility The company that supplies the product on the market is required to equip its devices or systems with the following documentation: o product energy label; o product data sheet; o system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices; o technical data sheet of the system with the parts relating to the product or the system already completed. Dealer Responsibility First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device and/or system to the public. Therefore even professionals such as plumbers, installers or planners can fall into this category. Everyone is required to ensure that: o all appliances and/or systems are equipped with the respective labels and make sure that they are clearly visible; o all devices and/or systems are always accompanied by the mandatory technical data sheets; o any type of advertising, promotional or technical material in which energy data or price indications are shown, contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and hot water production will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP): The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL Depending on the type of device, there are different labels. Those with efficiency classes A, A+ and A++ certify the products with the highest performance. Furthermore, two different classifications are envisaged for domestic heating and for the hot water production service, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the final customer can make his choice in the most informed way possible. SYSTEM LABEL In addition to the product label, the system label is also provided if a series of matched appliances is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label in order to inform the end user in the best possible way. Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.231,00
Biasi Biasi Gas Boiler Renew Cond Plus 35 S LPG Complete With Fume Exhaust Kit
Technical features Model: rinNOVA COND PLUS E 35S Energy label specifications according to the European ErP directive Class A heating energy efficiency Sanitary energy efficiency Class A Withdrawal profile: XL Characteristics of heating/DHW operation: Heating / DHW nominal heat input kW 29.0 / 33.5 Heating / DHW maximum useful output 60°/80°C * 28.2 / 32.5 Energy yield n° **** NOx class 6 Expansion vessel capacity 7.0 l (total) Maximum range (ΔT=25K) / (ΔT=35K) 18.6 / 13.3 Degree of protection IPX5D Dimensions HxWxD 700x400x290; 34.5Kg General characteristics renew COND PLUS RinNova Cond Plus is the new BIASI range of wall-mounted condensing boilers: excellent performance thanks to the new heat exchanger and ease of use thanks to the digital control panel with display. Available in versions for heating and domestic hot water production and for heating only RinNova Cond Plus presents a complete range of powers, 20 and 30 kW combi models and 16 KW SV models, in the same extremely compact dimensions (700 x 400 x 290 mm) . RinNova Cond Plus has its strong point in the innovative heat exchanger designed to provide high yields that last over time digital control panel, designed to communicate with the user in an easy and comfortable way. Like the entire BIASI condensing range, RinNova Cond Plus allows you to obtain maximum savings from climatic thermoregulation, based on the system in which the boiler is installed Characteristics: High yields (★★★★ compliant with yield directive 92/42 EEC and Legislative Decree 311/06) Sanitary comfort (★★★ EN 13203) Primary condensing exchanger in stainless steel with steel lining to offer maximum resistance to corrosion Total premix burner, built in stainless steel (Class NOx 6) Modulation 1:5 CNG and also LPG Sanitary plate heat exchanger in stainless steel 7 liter expansion tank High efficiency pump with low energy consumption Maximum power adjustable according to the system • IPX5D degree of protection Can be installed in a partially protected place Integration with BIASI solar systems, using a solar kit Digital control panel with backlit display Analog pressure reading Arrangement for remote control and external probe. Control panel Summer/winter/off selector Heating temperature regulator DHW temperature regulator Analog pressure reading DHW and heating temperature visualization from the display Display of fault diagnostics, block status and fault history Recommended fill display and fill guide View annual maintenance expiry The display operates according to the modes: 1. INFO. Info mode displays the following information: External temperature (in case of external probe connected) K value (in case of external probe connected) Sanitary / heating temperatures chosen by the user Smoke temperatures. 2. PROGRAMMING. The programming mode allows you to change the boiler parameters. - In chimney sweep mode it is possible to test the boiler and adjust the gas valve. Thermoregulation By connecting the external probe and the remote control (optional) directly to the boiler, climatic regulation can be used. RinNova Cond Plus will adapt the system water temperature to the external climatic conditions, ensuring that the desired room temperature is reached without waste and optimizing consumption. By using the climatic regulation, the regulation efficiency is also raised, giving greater value to your home. High regulation single coil primary heat exchanger Biasi introduces on the market the new stainless steel heat exchanger for condensing boilers: Round. Round is a compact monothermal heat exchanger based on a stainless steel coil with an oval section. The heat exchanger consists of a combustion chamber, condensing area and an insulated metal disc protected with silicone ceramic fiber which separates the two areas. By using a single strip of stainless steel to produce the coil, including inlet/outlet fittings, the following benefits are achieved: Accumulation of dirt and debris is avoided The water flow is uniformly distributed and guarantees a homogeneous heat exchange The water flow is constant for a longer life of the product Reduction of pressure drops with optimized circuit. The ease of cleaning and the robustness of this exchanger are one of the main strengths of the product since it can be used on new systems but also on old systems in the event of renovations. Round integrates the round flow function in which the water produces a centrifugal cleaning effect on the internal walls of the single coil. The absence of circuits in parallel guarantees an easy "washing" operation of the exchanger and the elimination of any air present in the system circuit. All ready for Energy Labeling What is it about? From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy-intensive sectors: construction For placing on the European market, the eco-design directive ( ErP known as « Energy Related Products ») imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres As in the household appliances sector, the energy labeling of products with a capacity of less than 70 kW will give consumers simple, recognizable information which allows for comparisons on the performance and energy consumption of the product you wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. Is it about me too? YES, it affects everyone: professionals and end users The information indicated on the energy label will allow professionals to recommend the right product and individuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015 , the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. Supplier responsibility The company that supplies the product on the market is required to equip its devices or systems with the following documentation: product energy label; technical product sheet; system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices; technical data sheet of the system with the parts relating to the product or system already completed. Dealer Responsibility First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device and/or system to the public. Therefore even professionals such as plumbers, installers or planners can fall into this category. Everyone is required to ensure that: all appliances and/or systems have their respective labels and make sure that they are clearly visible; all devices and/or systems are always accompanied by the mandatory technical data sheets; any type of advertising, promotional or technical material showing energy data or price indications contains an indication of the energy efficiency class. The new ErP regulations ENERGY LABELLING: Appliances for space heating and hot water production will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP) : The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL Depending on the type of device, there are different labels. Those with efficiency classes A, A+ and A++ certify the products with the highest performance. Furthermore, two different classifications are envisaged for domestic heating and for the hot water production service, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the final customer can make his choice in the most informed way possible. SYSTEM LABEL In addition to the product label, the system label is also provided if a series of matched appliances is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label in order to inform the end user in the best possible way. Product Guarantee: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.024,00
Biasi Gas Boiler Biasi Renew Cond XE 35s Condensing Complete With LPG Fume Exhaust Kit -New Erp
BIASI rinNOVA COND XE 35S CONDENSING BOILER COMPLETE WITH LPG LPG FUME EXHAUST KIT - NEW ErP Technical specifications: Energy label specifications according to the European ErPÿ directive Class A heating energy efficiency Sanitary energy efficiency Class A Withdrawal profiles: XXL Characteristics of heating/sanitary exercises: Thermal powerÿuseful sanitaryÿ(80/60ø C)ÿkW (kcal/h)ÿ33.4 (28,724) Heating capacityÿuseful heatingÿ(80/60ø C)ÿkW (kcal/h)ÿ32.1 (27,606) Heat input(*)ÿnominalÿkW (kcal/h)ÿ34.0 (29,240) Heat inputÿminimumÿkW (kcal/h)ÿ8.5 (7,309) Sanitary flowÿt =25øKÿl/minÿ21.6 Dimensions (HxWxD) 700x400x290 mm Main features renew COND Xÿ RinNova Cond X The BIASI premixed condensing range completes: perfectÿfor underfloor systems for radiator systems, the compact condensing boiler that ensures high yields, low consumption and respect for the environment. Availableÿfor heating and domestic hot water production, in powers of 25 and 35 kW and forÿheating only in powers of 16, 25 and 35 kW. Characteristics: High yields (in compliance with yield directive 92/42 EEC and Legislative Decree 311/06) Sanitary comfortÿÿ(EN 13203) Primary and condensing exchanger in stainless steel with plastic linings to offer maximum resistance to corrosion Total premix burner, built in stainless steel (class NOx 5) Sanitary plate heat exchanger in stainless steel High efficiency pump with low energy consumption Maximum power adjustable according to the needs of the system Degrees of protection IPX5D Installability in a partially protected place Integration with BIASI solar systems using a solar kit digital control panel with backlit display Digital pressure reading by pressure transducer Arrangement for external probe remote control Four-controllers Summer/winter/off selector Heating temperature regulator DHW temperature regulator Digital pressure reading DHW and heating temperature visualization from display Display of fault diagnostics, fault history block status View recommended fill View annual maintenance expiry The display operates according to the modes: INFO. Inf mode displays the following information: External temperature (in case of connected external probe) K value (in case of connected external probe) Sanitary / heating temperatures chosen by the user Smoke temperatures. 2. PROGRAMMING. The programming mode allows you to modify the boiler parameters. In chimney sweep mode it is possible to test the boiler and make adjustments to the gas valve. RinNova Cond XE: Adjustable maximum power The adjustable maximum useful heating power parameter meets the needs of modern construction without compromising comfort required in the production of domestic hot water. In fact, this function makes it possible to limit the maximum useful power in heating, independently of the useful domestic power. Hot water even with the sun RinNova Cond XE for heating and hot water production: the sanitary exchangerÿin stainless steel combined with the electronic management and low inertia of the primary exchangerÿdetermine excellent performance even in the production of domestic hot water.ÿFor the production of domestic hot water RinNova Cond XE can be combined with BIASI solar systems using specific solar kit (optional). The boiler cuts in only when necessary, making the most of solar energy and guaranteeing the comfort required by the user. Included in delivery: Boiler support bracket and paper template Boiler power cable Condensate collection siphon Quick instruction to the user. All ready for Energy Labeling What it is about: From 26 September 2015 the directives of the European Commission concerning eco-design and energy labeling will apply. These two directives aim to achieve savings in one of the most polluting and most energy intensive sectors: construction For placing on the European market, the directive on ÿeco-designÿ(ErP notcome®ÿEnergy Related Productsÿ¯) imposes a minimum energy efficiency for heating devices and hot water production in domestic premises. The directive applies to: generators with a capacity of less than 400 kW water heaters with a capacity of less than 400 kW, kettles with a capacity of less than 2000 litres As in the household appliances sector, the energy labelingÿof products, with a capacity of less than 70 kW, will give consumers simple, recognizable information which allows them to make comparisonsÿon the performance and energy consumption of the product they wish to purchase. The energy label will be included in all boilers, water heaters and storage tanks placed on the market from 26 September 2015. It's about me tooÿ YES, it affects everyone: professionals and end users The information indicated on the energy labelÿwill allow professionals to recommend the right productÿÿindividuals to benefit from the information available. The user will be able to easily compare the performance of the products. From 26 September 2015, the label will be present on the following products: boilers, electric water heaters, thermodynamic water heaters, solar water heaters, storage tanks, heat pumps, solar systems and control systems. Supplier's responsibility The company that supplies the product on the market is required to equip its system devices with the following documentation: energy label ; system energy label in addition to that of the product, both if it sells a system that includes the product in question, and if this, in the future, can be sold combined with other additional devices product datasheet ; technical data sheet of the system with the parts relating to the products and the system already completed. Responsibilities of Resellersÿ First of all, it should be clarified that the reseller can be anyone who sells, rents, offers for rent/sale and exhibits a device/system to the public. Therefore, even professionals such as plumbers, installers, designers can fall into this category. All bound to ensure that: all appliances and/systems having their respective labels and making sure they are clearly visible;ÿ all appliances and/systems must always be accompanied by the obligatory technical data sheets;ÿ every type of advertising material, technical promotional material which shows energy data and price indications, contains an indication of the energy efficiency class. The new ErP regulations: ENERGY LABELLING: Appliances for space heating and the production of hot water will have to be equipped with the new energy label which will report the energy class and the main performance data. The energy class must also be mentioned in the technical, commercial and advertising documentation of the appliances. ECODESIGN (ErP): The new ErP regulations impose the minimum energy efficiency that space heating and hot water production appliances must achieve in order to obtain the CE mark and be marketed in Europe. These new limits will exclude obsolete technologies from the market, significantly raising the level of energy efficiency of products. PRODUCT LABEL There are different labels depending on the type of appliance. Those with efficiency classes A, A+ and A++ certify products with the highest performance. Furthermore, two different classifications are foreseen for domestic heating and for hot water production services, so much so that mixed products must show both classifications. In addition to the energy class, the labels contain other information, so that the end customer can make his choice in the most aware way possible. SYSTEM LABEL In addition to the product label, the system label is also providedÿin cases where a series of appliances combined with each other is offered. This label must also be included in the technical and commercial documentation of the system. Those proposing such systems will have to calculate the performance using a predefined calculation algorithm and display the label so as to inform the end user in the best possible way. Warranty: All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€997,00
Biasi Biasi Renew In 35s Condensing Built-in Boiler Complete With Methane Or LPG / LPG Fume Exhaust Kit
Biasi rinNova boiler in 25S built-in condensing complete with methane fume exhaust kit * Model: RENEW IN E 35S Energy label specifications according to the European ErP directive * Class A heating energy efficiency * Sanitary Energy Efficiency Class A * Withdrawal profile: XL Characteristics of heating/DHW operation: * DHW useful thermal power: 33.4 kW * Useful heating thermal power: 32.1 kW * Nominal kW heat input(*): 34 kW * Efficiency at 100% load: 107.1% * Sanitary flow rate â??t =25°K l/min: 21.6l/min * IPX5D degree of protection * Dimensions hxwxd: mm 1200 x 600 x 240 * CNG or LPG powered Included in delivery * External probe * Siphon * Analog pressure gauge * Quick user instruction. RinNova RinNova IN E is the basic model of Biasi built-in condensing boilers. is available in the versions: Combi, in powers 25 and 35 kW Heating only, in the 16 and 25 kW powers in order to allow ample flexibility in the choice of systems and respond to the various residential needs. RinNova IN E therefore combines the high efficiency and low polluting emissions typical of premixed boilers with the space-saving feature typical of built-in boilers. Characteristics: High performance Primary condensing exchanger in stainless steel with plastic coating to offer maximum resistance to corrosion Total premix burner, built in AISI 316L stainless steel (Class NOx 5) Sanitary plate heat exchanger in stainless steel High efficiency pump with low energy consumption Maximum power adjustable according to system requirements Degree of protection IPX5D Integration with BIASI solar systems through Unified box The RinNova IN E range (16SV, 25SV and S) can be installed in the universal box of dimensions 1200 x 600 x 240 mm. The RinNova IN E 35S model can be installed in the same box and requires a specific embossed central door to house the oversized exchanger of this model. Therefore RinNova IN E 35S is installed in a box with overall dimensions of 1200 x 600 x 255 mm: the embossed door causes an increase in depth towards the outside of only 1.5 cm. The box has been redesigned to facilitate the installation of BIASI products: Three front doors to allow easy access from the bottom door and front ejection. Hydraulic template of the box shown on the sheet metal itself to speed up the operation of connecting the boiler to the system. Simple assembly to reduce overall dimensions and wasted time on site! Class 5 NOx (EN297) The total premix burner optimizes the mixture of air and gas, maximizing yields and minimizing polluting emissions. Rinnova IN E belongs to the most restrictive class in terms of emissions with only 17 ppm of NOx produced, a quantity 5 times lower than the quantity of NOx produced by standard boilers. Sanitary (EN 13203) The domestic hot water comfort function ensures the best performance in terms of domestic hot water, reducing the waiting time for the availability of hot water and guaranteeing temperature stability. Boiler controls Rinnova IN E is equipped with a digital control panel to facilitate the selection of the desired temperature and the boiler parameters. The system pressure can be viewed on the display and on the pressure gauge, fitted as standard on the Rinnova IN E. Warranty All products for sale on our site are new and packed. The warranty on this item is 24 months from the date of purchase.
€1.105,00